• Title/Summary/Keyword: 안정성 평가

Search Result 5,519, Processing Time 0.038 seconds

Results of the Reconstruction of Anterior Cruciate Ligament with Freshfrozen Achilles Allograft and of the Second-look Arthroscopy (신선 동결 동종 아킬레스건을 이용한 전방 십자인대 재건술 후 2차 관절경소견)

  • Yoo, Jae-Doo;Kim, Sung-Il
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.111-116
    • /
    • 2007
  • Purpose: To assess the clinical results of ACL reconstruction with a fresh frozen Achilles allograft, retrospectively and the findings of the graft in second look arthroscopy. Materials and Methods: Twenty-eight ACL reconstructions using fresh frozen Achilles tendon allograft were included in this study between March 1999 and February 2003. The average age was 31.2 years old and the average follow-up was 16.6 months(range: 12-26 months). The clinical evaluation was done by KT-1000 arthrometer, Lysholm knee score, range of motion, Lachman and pivot-shift test. Results: In the last follow-up of Lachman test, 21 cases showed normal, 5 cases grade 1, 2 cases grade 2 and 1 case grade1. The results of pivot-shift test data, 23 cases(82.1%) were normal, 4 cases(14.3%) grade 1, 1 case(3.6%) grade 2. The mean maximum side-to-side difference was improved from 6.75mm preoperatively to 2.46mm in the last follow-up. Lysholm knee score was improved from 73.5 preoperatively to 91.6 in last follow-up. Re-rupture of the ACL graft was found in one case and one case of wound infection in the tibial incision was found. The 6 cases showed the good synovialization of the ACL graft. Conclusion: The anterior stability was restored with ACL reconstruction using fresh frozen Achilles allografts and the good synovialization was found in the second-look arthroscopy

  • PDF

A Dynamic Behavior Evaluation of the Curved Rail according to Lateral Spring Stiffness of Track System (궤도시스템의 횡탄성에 따른 곡선부 레일의 동적거동평가)

  • Kim, Bag-Jin;Choi, Jung-Youl;Chun, Dae-Sung;Eom, Mac;Kang, Yun-Suk;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.517-528
    • /
    • 2007
  • Domestic or international existing researches regarding rail damage factors are focused on laying, vehicle conditions, driving speed and driving habits and overlook characteristics of track structure (elasticity, maintenance etc). Also in ballast track, as there is no special lateral spring stiffness of track also called as ballast lateral resistance in concrete track, generally, existing study shows concrete track has 2 time shorter life cycle for rail replacement than ballast track due to abrasion. As a result of domestic concrete track design and operation performance review, concrete track elasticity is lower than track elasticity of ballast track resulting higher damage on rail and tracks. Generally, concrete track has advantage in track elasticity adjustment than ballast track and in case of Europe, in concrete track design, it is recommended to have same or higher performance range of vertical elastic stiffness of ballast track but domestically or internationally review on lateral spring stiffness of track is very minimal. Therefore, through analysis of service line track on site measurement and analysis on performance of maintenance, in this research, dynamic characteristic behaviors of commonly used ballast and concrete track are studied to infer elasticity of service line track and experimentally prove effects of track lateral spring stiffness that influence curved rail damage as well as correlation between track elasticity by track system and rail damage to propose importance of appropriate elastic stiffness level for concrete and ballast track.

  • PDF

Evaluation of Removal Efficiency of Pollutants in Constructed Wetlands for Treating Greenhouse Wastewater Under Different Filter Media, Configuration Methods and Agricultural Water Loading (시설하우스 농업배수 처리를 위한 인공습지에서 여재종류, 조합방법 및 부하량에 따른 오염물질 정화효율 평가)

  • Lee, Dong-Jin;Park, Jong-Hwan;Kim, Seong-Heon;Yoon, Chan-Woong;Cho, Ju-Sik;Lee, Seong-Tae;Heo, Jong-Soo;Seo, Dong-Cheol
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.1
    • /
    • pp.13-23
    • /
    • 2014
  • To obtain optimum filter media, configuration method and greenhouse wastewater loading in small-scale constructed wetlands (CWs) for treating greenhouse wastewater, the apparatuses were constructed with 4 kinds of combined systems such as vertical flow (VH)-Horizontal flow (HF), HF-VH, HF-VF-HF, VF-HF-HF CWs. The efficiencies of pollutants in greenhouse wastewater were investigated in various CWs under different filter media, configuration methods and agricultural water loading. Removal rates of pollutants under different filter media were in the other of coarse sand>broken stone${\fallingdotseq}$calcite${\fallingdotseq}$mixed filter media for COD, broken stone>mixed filter media>coarse sand>calcite for T-N, and calcite>mixed filter media>broken stone>coarse sand for T-P. The removal rates of pollutants in HF-VH-HF CWs at different configuration methods were higher than those in other configuration methods. The removal rates of pollutants were higher in the order of $150L\;m^{-2}day^{-1}{\fallingdotseq}300L\;m^{-2}day^{-1}$ > $600L\;m^{-2}day^{-1}$ under different greenhouse wastewater loading. Therefore, optimum configuration method was HF-VH-HF CWs, the optimum filter media was mixed filter media (coarse sand : broken stone : calcite=1 : 1 : 1), and the optimum greenhouse wastewater loading was $300L\;m^{-2}day^{-1}$ in HF-VH-HF CWs.

Development of Quality Assurance Program for the On-board Imager Isocenter Accuracy with Gantry Rotation (갠트리 회전에 의한 온-보드 영상장치 회전중심점의 정도관리 프로그램 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.212-223
    • /
    • 2006
  • Positional accuracy of the on-board imager (OBI) isocenter with gantry rotation was presented in this paper. Three different type of automatic evaluation methods of discrepancies between therapeutic and OBI isocenter using digital image processing techniques as well as a procedure stated in the customer acceptance procedure (CAP) were applied to check OBI isocenter migration trends. Two kinds of kV x-ray image set obtained at OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ},\;270^{\circ}$ and every $10^{\circ}$ and raw projection data for cone-beam CT reconstruction were used for each evaluation method. Efficiencies of the methods were also estimated. If a user needs to obtain an isocenter variation map with full gantry rotation, a method taking OBI image for every $10^{\circ}$ and fitting with 5th order polynomial was appropriate. However for a mere quality assurance (QA) purpose of OBI isocenter accuracy, it was adequate to use only four OBI Images taken at the OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ}\;and\;270^{\circ}$. Maximal discrepancy was 0.44 mm which was observed between the OBI source angle of $90^{\circ}\;and\;180^{\circ}$ OBI isocenter accuracy was maintained below 0.5 mm for a year. Proposed QA program may be helpful to Implement a reasonable routine QA of the OBI isocenter accuracy without great efforts.

  • PDF

Preliminary Study on the Standardization of Korean Version of Type D Personality Scale 14 : Internal Consistency and Construct Validity (D형 인격 척도의 표준화 예비연구 : 내적일치도 및 구성타당도)

  • Lee, Moon-Soo;Park, Young-Min;Lim, Hong-Euy;Song, Woo-Hyuk;Ahn, Jung-Chun;Kim, Seong-Hwan;Lee, Bun-Hee;Han, Chang-Su;Kim, Yong-Ku;Joe, Sook-Haeng;Ko, Young-Hoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.15 no.2
    • /
    • pp.81-87
    • /
    • 2007
  • Objectives : The distressed personality (type-D) pattern, consisting of negative affectivity and social inhibition, has been shown by Denollet et al. For measuring the Type D characteristics, Denollet has devised the 14 item Type D scale (DS14). In the present study, this instrument was translated into Korean. The reliability and validity of the Korean DS14 was pilot tested. Methods : Preliminary version of the total 17-item DS14 scale was translated into Korean. 372 controls that did not have any coronary heart diseases (CHD) were randomly sampled in Seoul and Gyeonggi province. Preliminary Korean version was applied to controls and 14 items were finally selected to maximize reliability of the scale. We compared the distribution of type-D personality among the normal controls, hypertensive patients, and the CHD patients. Results : 7 of 10 items in social inhibition were selected and final 14-item version was made. The internal consistency of negative affectivity (0.817) and social inhibition (0.797) were high. In addition, the prevalence of type-D personality in the CHD patients group was significantly higher than normal controls. Conclusion : These findings suggest that Korean version of DS14 is a valid tool for measuring the type D characteristics. Type-D characteristics can be suggested to predict adverse prognosis in patients with CHD.

  • PDF

Evaluation of Future Water Deficit for Anseong River Basin Under Climate Change (기후변화를 고려한 안성천 유역의 미래 물 부족량 평가)

  • Lee, Dae Wung;Jung, Jaewon;Hong, Seung Jin;Han, Daegun;Joo, Hong Jun;Kim, Hung Soo
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.345-352
    • /
    • 2017
  • The average global temperature on Earth has increased by about $0.85^{\circ}C$ since 1880 due to the global warming. The temperature increase affects hydrologic phenomenon and so the world has been suffered from natural disasters such as floods and droughts. Therefore, especially, in the aspect of water deficit, we may require the accurate prediction of water demand considering the uncertainty of climate in order to establish water resources planning and to ensure safe water supply for the future. To do this, the study evaluated future water balance and water deficit under the climate change for Anseong river basin in Korea. The future rainfall was simulated using RCP 8.5 climate change scenario and the runoff was estimated through the SLURP model which is a semi-distributed rainfall-runoff model for the basin. Scenario and network for the water balance analysis in sub-basins of Anseong river basin were established through K-WEAP model. And the water demand for the future was estimated by the linear regression equation using amounts of water uses(domestic water use, industrial water use, and agricultural water use) calculated by historical data (1965 to 2011). As the result of water balance analysis, we confirmed that the domestic and industrial water uses will be increased in the future because of population growth, rapid urbanization, and climate change due to global warming. However, the agricultural water use will be gradually decreased. Totally, we had shown that the water deficit problem will be critical in the future in Anseong river basin. Therefore, as the case study, we suggested two alternatives of pumping station construction and restriction of water use for solving the water deficit problem in the basin.

The Research to Correct Overestimation in TOF-MRA for Severity of Cerebrovascular Stenosis (3D-SPACE T2 기법에 의한 TOF-MRA검사 시 발생하는 혈관 내 협착 정도의 측정 오류 개선에 관한 연구)

  • Han, Yong Su;Kim, Ho Chul;Lee, Dong Young;Lee, Su Cheol;Ha, Seung Han;Kim, Min Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.180-188
    • /
    • 2014
  • It is very important accurate diagnosis and quick treatment in cerebrovascular disease, i.e. stenosis or occlusion that could be caused by risk factors such as poor dietary habits, insufficient exercise, and obesity. Time-of-flight magnetic resonance angiography (TOF-MRA), it is well known as diagnostic method without using contrast agent for cerebrovascular disease, is the most representative and reliable technique. Nevertheless, it still has measurement errors (also known as overestimation) for length of stenosis and area of occlusion in celebral infarction that is built by accumulation and rupture of plaques generated by hemodynamic turbulence. The purpose of this study is to show clinical trial feasibility for 3D-SPACE T2, which is improved by using signal attenuation effects of fluid velocity, in diagnosis of cerebrovascular disease. To model angiostenosis, strictures of different proportions (40%, 50%, 60%, and 70%) and virtual blood stream (normal saline) of different velocities (0.19 ml/sec, 1.5 ml/sec, 2.1 ml/sec, and 2.6 ml/sec) by using dialysis were made. Cross-examinations were performed for 3D-SPACE T2 and TOF-MRA (16 times each). The accuracy of measurement for length of stenosis was compared in all experimental conditions. 3D-SPACE 2T has superiority in terms of accuracy for measurements of the length of stenosis, compared with TOF-MRA. Also, it is robust in fast blood stream and large stenosis than TOF-MRA. 3D-SPACE 2T will be promising technique to increase diagnosis accuracy in narrow complex lesions as like two cerebral small vessels with stenosis, created by hemodynamic turbulence.

Development of Program for Renal Function Study with Quantification Analysis of Nuclear Medicine Image (핵의학 영상의 정량적 분석을 통한 신장기능 평가 프로그램 개발)

  • Song, Ju-Young;Lee, Hyoung-Koo;Suh, Tae-Suk;Choe, Bo-Young;Shinn, Kyung-Sub;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.89-99
    • /
    • 2001
  • Purpose: In this study, we developed a new software tool for the analysis of renal scintigraphy which can be modified more easily by a user who needs to study new clinical applications, and the appropriateness of the results from our program was studied. Materials and Methods: The analysis tool was programmed with IDL5.2 and designed for use on a personal computer running Windows. For testing the developed tool and studying the appropriateness of the calculated glomerular filtration rate (GFR), $^{99m}Tc$-DTPA was administered to 10 adults in normal condition. In order to study the appropriateness of the calculated mean transit time (MTT), $^{99m}Tc-DTPA\;and\;^{99m}Tc-MAG3$ were administered to 11 adults in normal condition and 22 kidneys were analyzed. All the images were acquired with ORBITOR. the Siemens gamma camera. Results: With the developed tool, we could show dynamic renal images and time activity curve (TAC) in each ROI and calculate clinical parameters of renal function. The results calculated by the developed tool were not different statistically from the results obtained by the Siemens application program (Tmax: p=0.68, Relative Renal Function: p:1.0, GFR: p=0.25) and the developed program proved reasonable. The MTT calculation tool proved to be reasonable by the evaluation of the influence of hydration status on MTT. Conclusion: We have obtained reasonable clinical parameters for the evaluation of renal function with the software tool developed in this study. The developed tool could prove more practical than conventional, commercial programs.

  • PDF

Comparison of Reflectance and Vegetation Index Changes by Type of UAV-Mounted Multi-Spectral Sensors (무인비행체 탑재 다중분광 센서별 반사율 및 식생지수 변화 비교)

  • Lee, Kyung-do;Ahn, Ho-yong;Ryu, Jae-hyun;So, Kyu-ho;Na, Sang-il
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.947-958
    • /
    • 2021
  • This study was conducted to provide basic data for crop monitoring by comparing and analyzing changes in reflectance and vegetation index by sensor of multi-spectral sensors mounted on unmanned aerial vehicles. For four types of unmanned aerial vehicle-mounted multispectral sensors, such as RedEdge-MX, S110 NIR, Sequioa, and P4M, on September 14 and September 15, 2020, aerial images were taken, once in the morning and in the afternoon, a total of 4 times, and reflectance and vegetation index were calculated and compared. In the case of reflectance, the time-series coefficient of variation of all sensors showed an average value of about 10% or more, indicating that there is a limit to its use. The coefficient of variation of the vegetation index by sensor for the crop test group showed an average value of 1.2 to 3.6% in the crop experimental sites with high vitality due to thick vegetation, showing variability within 5%. However, this was a higher value than the coefficient of variation on a clear day, and it is estimated that the weather conditions such as clouds were different in the morning and afternoon during the experiment period. It is thought that it is necessary to establish and implement a UAV flight plan. As a result of comparing the NDVI between the multi-spectral sensors of the unmanned aerial vehicle, in this experiment, it is thought that the RedEdeg-MX sensor can be used together without special correction of the NDVI value even if several sensors of the same type are used in a stable light environment. RedEdge-MX, P4M, and Sequioa sensors showed a linear relationship with each other, but supplementary experiments are needed to evaluate joint utilization through off-set correction between vegetation indices.

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.