• Title/Summary/Keyword: 안전 가이드라인

Search Result 432, Processing Time 0.027 seconds

Application Method of Remote Site Monitoring in Public Road Construction Projects (공공 도로건설사업에서의 원격 현장모니터링 적용방안에 관한 연구)

  • Ok, Hyun;Kim, Seong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6550-6557
    • /
    • 2013
  • The public road construction projects awarded by the regional construction and management office, which is an affiliate of the Ministry of Land, Infrastructure and Transport, are managed by construction supervision officers. These officials frequently visit a large number of construction sites to conduct inspections and supervision tasks. Therefore, the site management efficiency is essential in terms of the time and money spent in travelling to the sites. The introduction of a site monitoring management system is considered necessary to minimize the number of site visits and enable remote monitoring of the construction progress to enhance the business efficiency of the construction supervision officers. In this study, a remote site monitoring system was constructed using web cameras for public road construction works. The trial applications were implemented by selecting ten constructions sites. The effectiveness of the system was analyzed to assess its applicability. In an assessment of the applicability of the verification results, remote site monitoring showed cost savings of approximately 35% compared to the existing site management. The guidelines for applying the site monitoring management system were provided, the introduction plan was investigated, and the improvement method was presented. The results showed that the system is likely to minimize the unnecessary site visits, remove the risk factors at vulnerable areas in the sites beforehand, and prevent a range of disasters and accidents. In addition, the quality of the infrastructures is likely to improve through the prevention of accidents and the elimination of substandard and faulty construction work.

Old Inner City Regeneration of Local Small-and-Medium Cities for the Invigoration of Commercial and Business Function : case of Dangjin-gun (상업 및 업무기능 활성화를 통한 지방중소도시 구도심 재생방안 : 당진군을 중심으로)

  • Choi, Ki-Tack;Lee, Joo-Hyung
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.11
    • /
    • pp.173-184
    • /
    • 2011
  • This study suggests the invigoration strategies of commercial and business functions for regeneration of old inner city as city center by examining Dangjin County which is a typical example of the local small-and-medium city where old inner city had declined as the city grew. I conducted a conjoint analysis in terms of important introduction functions and city regeneration directions for the invigoration. The results upon this are as follows. First, low-density of commercial and business places and the utilization of historical and cultural resources instead of the high-density mixed-use development should be considered. Second, It is important to promote regional specialized business and facilities rather than to attract new industry(high-tech industry) for activating local economy. Third, specific and practical countermeasures for resettlement of low-incomes and for maintenance of existing business zone should be established. Fourth, in terms of the maintenance and management, regulation on illegal commercial transactions, improvement of public spaces, and securement of user safety should be considered. Fifth, in terms of consolidation of functions, easier accessibility using public transportations, advertising and promotion of the city, and holding a number of events should be contemplated. Sixth, supporting for business activities and for establishing guides for design of old inner city should be needed. Seventh, public institutions should play a role as a bridge between local residences and experts for balanced regional development.

Study on Developing Assessment Guideline for Safety and Performance of Electric Moxibustion Apparatus (전기식 온구기에 대한 안전성 및 성능 평가 가이드라인 개발 연구)

  • Yi, Seung-Ho;Kang, Jung-Won;Nam, Dong-Woo;Kim, Eun-Jung;Lee, Hye-Jung;Kim, Kap-Sung;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.75-86
    • /
    • 2010
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric moxibustion apparatus (class II medical device). Methods : We drafted the guideline for safety and performance assessment of electric moxibustion apparatus by referring the existing standards, guidelines and measurement data from commercially available products. Temperature characteristics such as maximum temperature and ramp time, and physical characteristics such as weight, noise and diameter were measured. User friendliness was also evaluated for commercial devices. Results : This guideline only can be applied to the electric moxibustion apparatus where moxa is being heated by electricity for medical proposes. Maximum temperature of higher than $50^{\circ}C$ can be achieved mostly. Ramp rate of temperature seems to be reliable. Control of temperature is needed to be improved. Moxa and its derivative products seem to be regulated for reliable temperature performance for clinical application. Requirements for design and development of electric moxibustion apparatus are suggested : temperature indicator, temperature control and its accuracy, safety measure, surge protection, user friendliness and instruction for use (IFU). Design recommendation of the reduction of noise level and energy loss are suggested for better products. Conclusions : We proposed a guideline for safety and performance assessment of electric moxibustion apparatus to improve the quality of relating products and aid their commercialization by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

Constructing Topographies of EMF Risks from Underground Power Lines (전자파 위험 지형도의 상이한 구성: 지중 송전선로 위험 논쟁을 중심으로)

  • Kim, JooHui
    • Journal of Science and Technology Studies
    • /
    • v.19 no.3
    • /
    • pp.119-166
    • /
    • 2019
  • The risk of electromagnetic field(EMF) from power lines has been heavily disputed whenever high-voltage power line towers were built in South Korea. Local communities and civic groups had regarded burying the lines in the ground as an alternative to building power line towers. In 2014, however, when an elementary school science teacher reported the results of EMF measurements over the underground power lines to the Asian Citizens' Center for Environment and Health (ACCEH), the risk controversy over underground power lines took a whole new turn. The level of EMF from underground power lines turned out to be higher, and therefore more harmful than that from power line towers. In the debates that took place from then on over the EMF risk, ACCEH and NIER(National Institute of Environmental Research) presented conflicting topographies of EMF risk. This paper examines measuring practices of ACCEH and NIER by analyzing the measuring sites, measuring devices, and measuring heights chosen by each organization. This paper further examines how ACCEH and NIER mobilized various standards(EMF exposure limit, measurement guideline, categorization of carcinogens) differently. This controversy on the EMF from underground power lines of Seoul has raised concerns on the non-thermal effects of EMF in the long-term exposure and has led people to question whether burying the power lines is the safe alternative to building power line towers. Furthermore, this suggests conflicting answers on whether Seoul, where 90 % of transmission lines were already buried, is a safely managed place or not.

Study on the Equation of Natural Period of Middle and Low Rise Building of Upper-Walled Lower Frame Type (중저층 상부벽식 하부골조 구조의 고유주기 산정식에 관한 연구)

  • Yoo, Suk-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.60-67
    • /
    • 2021
  • According to the 「Guidelines of Structural Design for Piloti Building」 of the Ministry of Land, Infrastructure and Transport (2018), the natural period of middle and low rise building of upper-walled lower frame type, such as the domestic multiplex house in piloti style, is suggested for safety to apply the existing code formula of the wall structure. However, the current code formula of the wall structure was provided based on actual measurement of high-rise wall-type structures that mainly exhibit bending behavior. So it is considered that it is not suitable for a piloti-type house with four stories or less, where the wall behaves in shear. See also Park et al. (2000) confirmed that the effect of the lower frame part is greater than that of the upper wall part in the natural period of complex structures with 10 or more floors through analytical studies. Therefore, in this study, in order to examine the effect of the lower frame on the natural period of the middle and low-rise piloti structure, the estimation of natural period by the finite element analysis, approximation formula and ccurrent code formula was performed for the target structures with the shear and flexural stiffness of the upper wall and the shear stiffness of the lower frame as variables. As result, it was found that the change in the shear stiffness of the lower frame had a greater effect on the natural period of the whole building than the change in the bending or shear stiffness of the upper wall.

Development of AAB (Algorithm-Aided BIM) Based 3D Design Bases Management System in Nuclear Power Plant (Algorithm-Aided BIM 기반 원전 3차원 설계기준 관리시스템 개발)

  • Shin, Jaeseop
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.2
    • /
    • pp.28-36
    • /
    • 2019
  • The APR1400 (Advanced Power Reactor 1400MW) nuclear power plant is a large-scale national infrastructure facility with a total project cost of 8.6 trillion won and a project period of 10 years or more. The total project area is about 2.17 million square meters and consists of more than 20 buildings and structures. And the total number of drawings required for construction is about 65,000. In order to design such a large facility, it is important to establish a design standard that reflects the design intent and can increase conformity between documents (drawings). To this end, a design bases document (DBD) reflecting the design bases that extracted in regulatory requirements (e.g. 10CFR50, Korean Law, etc.) is created. However, although the design bases are important concepts that are a big framework for the whole design of the nuclear power plant, they are managed in 2-dimensional by the experts in each field fragmentarily. Therefore, in order to improve the usability of building information, we developed BIM(Building Information Model) based 3-dimensional design bases management system. For this purpose, the concept of design bases information layer (DBIL) was introduced. Through the simulation of developed system, design bases attribute and element data extraction for each DBIL was confirmed, and walls, floors, doors, and penetrations with DBIL were successfully extracted.

Acoustic outputs from clinical ballistic extracorporeal shock wave therapeutic devices (임상에서 사용중인 탄도형 체외충격파 치료기의 음향 출력)

  • Cho, Jin Sik;Kwon, Oh Bin;Jeon, Sung Joung;Lee, Min Young;Kim, Jong Min;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.570-588
    • /
    • 2022
  • We scrutinized the acoustic outputs from the 70 shock wave generators of the 15 product models whose technical documents were available, among the 46 ballistic extracorporeal shock wave therapeutic devices of 11 domestic and 6 foreign manufacturers, approved by the Minster of Food & Drug Safety (Rep. Korea). We found that the acoustic Energy Flux Density (EFD), the most popular exposure parameter, was different by up to 563.64 times among shock wave generators at their minimum output settings and by up to 74.62 times at their maximum settings. In the same product model, the EFD was shown to vary depending on shock wave transmitters by up to 81.82 times at its minimum output setting and by up to 46.15 times at its maximum setting. The lowest EFD 0.013 mJ/mm2 at the maximum output settings was much lower (2.1 %) than the maximum value 0.62 mJ/mm2 at the minimum settings. The Large acoustic output differences (tens to hundreds of times)from the therapeutic devices approved for the same clinical indications imply that their therapeutic efficacy & safety may not be assured. The findings suggest the regulatory authority to revise her guideline to give clearer criteria for clinical approval and equality in performance, and recommend the authority to initiate a post-approval surveillance as well as a test in conformance between the data in technical documents and the real acoustic outputs clinically used.

Current Status and Technologies for Treating Groundwater Arsenic Pollution in Bangladesh (방글라데시 지하수 내 비소 오염 현황 및 처리기술)

  • Tashdedul, Haque Md;Reyes, Nash Jett DG.;Jeon, Minsu;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.24 no.2
    • /
    • pp.142-154
    • /
    • 2022
  • Arsenic (As) contamination in groundwater is one of the main problems in Bangladesh. As toxicity causes serious human health problems such as edema, skin cancer, bladder cancer, lung cancer, hyperkeratosis, premature birth, and black foot disease. As contamination in groundwater mainly originates from the geological characteristics of the area due to the influence of anthropogenic activities. Since most of the people in Bangladesh rely on tube well for drinking water, it is necessary to investigate the current status of As pollution and identify the treatment technologies that can be used to provide arsenic-free drinking water in water-scarce areas. A total of 92 papers were reviewed in this study to present a complete overview of the recent status of groundwater As contamination in Bangladesh and different low-cost remediation technologies. A method for evaluating the relative feasibility of different treatment technologies was also utilized to determine the most appropriate technologies for groundwater As treatment in Bangladesh. The districts with the highest groundwater As contamination include Brahamanbariya, Tangail, Barisal, Pabna, Patuakhali, Kurigram, Magura, and Faridpur, with concentrations exceeding 0.05 mg/L. Only six districts had relatively low groundwater arsenic concentrations (0.01 mg/L), including Kushtia, Khagrachari, Jessore, Dinajpur, Meherpur, and Munshiganj. There were a number of technologies used for treating As in water, but aerated electrocoagulation, Mg-Fe-based hydrotalcite-like compound, and electro-chemical As remediation (ECAR) reactor were found to be the most feasible treatment methods for As. Overall, the investment, operational, and maintenance costs, availability of materials, and expertise requirements should be considered when selecting the most appropriate treatment method for As in water.

erratum : A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (erratum : 전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.44 no.1
    • /
    • pp.128-128
    • /
    • 2023
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

Agents Used for Pediatric Dental Sedation (소아치과 진정법에 사용되는 약제)

  • Kim, Jiyeon;Jeong, Taesung;Yang, Yeonmi;Yoo, Seunghoon;Choi, Sungchul;Shin, Teojeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.1
    • /
    • pp.109-116
    • /
    • 2016
  • Sedation is an indispensable part of contemporary pediatric dentistry. The Korean Academy of Pediatric Dentistry (KAPD) organized the dental sedation committee to help members perform safer and more effective sedation. The committee surveyed 111 members who practice dental sedation to figure out the present state of sedation in 2014. According to the survey, 86% of the respondents indicated that they were interested in continuing education of sedation. The most interesting topic was sedation related emergency management, followed by safe dosages of sedative drugs. However, it is not realistic to establish the recommended dosages as a guideline since the selection of agents and dosages depend on various factors. In order to provide successful sedation, pediatric dentist should make an individual sedation plan for each procedure. It is important to understand not only the properties of each sedative, but also interactions with other drugs. This article reviews useful information of commonly used agents for dental sedation and summarizes the recommended dosages from the Physicians' Desk Reference (PDR) and some famous pediatric dentistry textbooks.