Analysis of Transient Characteristic in the Railway High Voltage Distribution Lines Using PSCAD/EMTDC at Method of Protection for One Line Ground Fault (PSCAD/EMTDC를 이용한 철도 고압 배전계통의 과도특성 해석 및 1선 지락사고에 대한 보호방안)

  • Park, Kye-In;Chang, Sang-Hoon;Choi, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.51-56
    • /
    • 2008
  • High quality power supplying of high voltage distribution lines electric railway system is the important function, high voltage distribution system is complicated witch is compose with distribution line, circuit break, protection facilities and so on. Among this components, role of substation is most important for elevation of reliability in electric power system. Therefore, the enhanced reliability considering the preventive inspection, repair work replacement is necessary. This paper proposes protection method in railway high voltage distribution lines. we model distribution system using PSCAD/EMTDC(Power System Computer Aided Design/Electro Magnetic Transients DC Analysis Program) and extract various fault data. In conclusion this methods can protection of ground fault.

A Study on the Characteristics of Shaft Electric Motive Force of Controllable Pitch Propeller - Focusing on the M/V Segero - (가변피치 프로펠러의 축기전력 특성에 관한 연구 - 세계로호를 중심으로 -)

  • Park, Kyung-Min;Im, Myeong-Hwan;Choe, Sang-Bom;Ahn, Byong-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.1
    • /
    • pp.135-140
    • /
    • 2022
  • Most machines are made of several types of . In particular, the shaft system of the ship consists of the brass of the propeller blade and the stainless steel of the shaft. When dissimilar the electrolyte solution of seawater, a voltaic cell and a shaft electromotive force is generated. This electromotive force causes electrical corrosion of the bearing and shaft supporting the shaft system. prevent this corrosion, a shaft grounding system is installed in ships. As for the experimental method, various information acquired by designing a program to periodically measure the electromotive force of the controllable pitchpropeller) system using an A/D converter of NI. This study analyzed the generation and characteristics of accumulator electromotive force for CPP and considered the installation location of the grounding system to remove the accumulator electromotive force.

A Study on Pullout Stability according to Abutment Shape of True Mechanicaaly Stabilized Earth Wall Abutment (순수형 보강토교대의 교대 형상에 따른 인발 안정성 검토)

  • Shin, Keun-Sik;Han, Heui-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.594-601
    • /
    • 2019
  • A true MSEW abutment is an abutment type that directly supports the load of a superstructure. Metal strips, which are in-extensile reinforcements, should be used to minimize abutment deformation. A study to derive the application conditions of a True MSEW abutment was carried out by Zevogolis(2007). As a result, the pullout factor of safety of the uppermost reinforcement was estimated to be the smallest. Therefore, the pullout factor of safety of the uppermost reinforcement is the most important design factor. Parameter analysis was conducted with the abutment length, abutment heel, and abutment height as variables. The pullout factor of safety increased with increasing abutment length and abutment heel length. This is because the contact area increases and the superstructure is dispersed as the abutment length and abutment heel length increase. The pullout factor of safety converges at an abutment length of 1.2m and an abutment heel length of 0.9m. This is because the effective length of the reinforcement is reduced due to the increase in contact area. On the other hand, the extension of the superstructure will increase if the abutment length and abutment heel length are increased excessively. In addition, earth-volume is increased if the abutment height increases excessively. This acts as an upper load on the MSE wall. Therefore, it needs to be examined carefully.

접지형태에 따른 배관의 고체.기체 2상류에서의 정전기 대전과 화재.폭발 위험성 평가

  • ;;;;;Tsutomu KODAMA;Mizuki YAMAGUMA
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.333-339
    • /
    • 2000
  • 현대사회의 공업화 및 도시화에 따라 NG(Natural Gas)를 포함하는 일반 가연성 가스의 누출에 의한 화재 및 폭발 재해는 매우 중요한 문제이다. 기체, 액체 및 분체가 단면적이 작은 분출구를 통해 공기중으로 이송 및 분출될 때 분출물질과 분출구와의 마찰로 인해 정전기가 발생한다./sup 1)/ 배관 내에 순수 NG가 이송·분출될 때의 대전량은 매우 작다./sup 2,3)/ 그러나, 배관 내에는 벤트스텍 등 외부에서 유입되는 먼지 또는 배관내의 부식에 의한 산화철(Fe₂O₃) 등의 분체가 포함될 수 있으며 이러한 분체가 천연가스 등과 함께 분출될 때 배관과의 마찰로 인해 대전량이 크게 상승된다./sup 3,4)/ 또한 분출되는 물질 구성입자들간 상호충돌에 의해서도 대전량은 더욱 증가하게 된다./sup 5)/(중략)

  • PDF

Characteristics for Ground Impedance of Counterpoise according to Position of Auxiliary Probe and Frequency (보조전극의 배치 및 주파수에 따른 매설지선의 접지임피던스 특성)

  • Gil, Hyoung-Jun;Kim, Dong-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.4
    • /
    • pp.33-37
    • /
    • 2012
  • This paper describes the characteristics for ground impedance of counterpoise according to position of auxiliary probe and frequency using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position of auxiliary probes. In order to analyze the effects of ground impedance due to the distance of the current probe and frequency, ground impedances were measured in case that the distance of current probe was located from 10[m] to 100[m] and the measuring frequency was ranged in 55 [Hz], 128[Hz], 342[Hz], and 513[Hz]. The results could be help to determine the position of auxiliary probe when the ground impedance was measured at grounding system.

Analysis of Deterioration Characteristics for Connection Factor used in Grounding System (접지시스템에 사용되는 접속요소의 열화특성 분석)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.2
    • /
    • pp.9-13
    • /
    • 2015
  • This paper describes the analysis of deterioration characteristics for connection factor used in grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

Development and Its Characterization of Earth Plate for Early Streamer Discharge (조기방전용 접지판의 개발 및 특성)

  • Choi, Sang-Won;Her, Yong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.46-48
    • /
    • 2014
  • This paper compared and demonstrated the performance of the earth plate for conventional type and early streamer discharging type developed a new plate in order to improve the performance of the ground plate for use in grounding. The results obtained are shown below; early streamer discharge earth plate was high 5 kV on DC flashover voltage and corona discharge current was higher than about 2 times under the same test conditions compared to the conventional earth plate. From the experiential result, streamer discharge earth plate had a function of rapid inflow/out flow than the general ground plane because of by corona discharge current to be generated in the sharp serrated in formed the ground plane when strike current occurred. In the future, the newly developed early streamer discharge ground plate would be beneficial for grounding work to be widely used to promote the convenience and economy of construction.

The study on the oscillatory frequency and factor(γ) of transient recovery voltage (과도회복전압의 진동주파수와 진폭율에 대한 연구)

  • Kim, Geun-Yong;Sung, Ki-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.652_653
    • /
    • 2009
  • 주어진 조건 하에서 의도하는 기간 동안 요구된 기능을 적절하게 수행하기 위해서는 제품의 신뢰성 확보가 무엇보다도 중요하다. 신뢰성 확보를 위해서는 제품의 안전성 및 내구성에 대한 고려가 충분히 이루어져야 한다. 고빈도 개폐를 목적으로 사용되는 전자기 접촉기 또한 제품의 안전성 및 성능의 신뢰성이 중요한 제품이라 할 수 있다. 그래서 이를 검증하기 위한 전자기 접촉기의 부하개폐동작성능에 대한 평가가 중요한 시험항목으로 부각되고 있다. 그리고 개폐특성을 평가하기 위한 부하는 규정된 과도회복전압특성을 얻을 수 있도록 조정되어야 한다. 본 논문에서는 부하측 중성점 접지 방식의 부하 회로 조정방법을 사용하여 전자기 접촉기의 개폐성능을 평가하기 위한 과도회복전압의 진동주파수와 진폭율의 특성을 고찰하였다.

  • PDF

Development of Multi Function Electrical Safety Measuring System (다기능 전기안전측정장치의 개발)

  • Yoo, Jae-Geun;Jeon, Jeong-Chay;Lee, Sang-Ick
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.244-246
    • /
    • 2005
  • 전기사업법 제 66조 및 동법 시행규칙 제 35조에 따라 실시하고 있는 일반용 전기설비의 정기점검은 점검의 효율성을 향상시키기 위해 무정전으로 누설전류 및 절연저항 등을 측정할 필요가 있다. 본 논문에서는 누설전류, 절연저항 및 접지저항 측정기능을 갖고 휴대가 편리하며 PDA와 통신이 가능한 다기능 전기안전측정장치를 개발하였다. 개발된 시스템은 가정집, 사무실, 상가 둥에서 기존의 계측기와 비교시험을 통해 오차율이 ${\pm}5%$ 이하가 되도록 하였다.

  • PDF

Design and Implementation of Wideband Grounding Impedance Measurement Device using IQ Demodulation Method (IQ 복조 기법을 이용한 광대역 접지 임피던스 측정기의 설계 및 구현)

  • Kim, Young-Jin;Gil, Hyung-Jun;Kim, Sung-Ju;Kim, Jae Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.19-24
    • /
    • 2016
  • One of key parameters on lightning protection system design of electric, information and communication system is grounding impedance. Earth impedance includes numerous information about earthing performance of grounding system. This paper suggests grounding impedance measuring device which is comprised of wideband current source, voltage and current measuring components. We used IQ Demodulation to measure more accurate phase difference of voltage and current. The range of frequency is up to 1 MHz that is IEEE defined as the range of lightning surge. We compared developed grounding impedance measuring device with existing one to test its performance, and we used grounding system while we implemented measurement and analysing by using fall of potential method IEEE Std.81 proposed.