Improvement of Elevator Management System after Completion (준공 이후 승강기 관리체계 개선에 관한 연구)

  • Cho, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.455-461
    • /
    • 2016
  • To operate a large structure or a high-rise building, elevator is essential. Nevertheless, elevator breakdowns or accidents have been consistently reported. When the accidents are not serious, the records are not reported and cumulated in the Korea Elevator Safety Agency. Additionally, in case of replacement or repair of the parts of elevator, conflicts about the person responsible for the expense of the replacement or repair are frequently occurred. However the record of accidents is not decreasing and the conflict about the fund of elevator repair is serious. So, it is needed to reduce the elevator accidents or malfunction, the operation stop of the elevator, the conflict between building owners and users. Therefore, in this study, the elevator maintenance procedures during defect liability period, the notification procedure in case of breakdown or accident elevator, the direction of elevator maintenance contracts, the direction of the elevator inspection were suggested.

A Design and Implementation of the Lift Safety Inspection System using Android Smart Phone (안드로이드기반 스마트폰을 이용한 승강기 안전진단 시스템 설계 및 구현)

  • Choi, Sung-Hyun;Kim, Jong-Soo;Kim, Tai-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.1
    • /
    • pp.113-118
    • /
    • 2012
  • This thesis suggests how to design and implement an Android smart phone application which can perform self check or safety inspection of lifts effectively. The safety checks of lifts go in the way that inspectors check the lifts' conditions generally and record manually following a form at the moment. This thesis analyses lift maintenance industry and introduces how to design a system to proceed effective self check using a smart phone with Android OS. By using a smart phone to check lifts, we can have advantages to improve the quality of self check and maintain careers establishing information database about safety items.

Developing the Test Module of $Hipass^{PLUS}$ Card (하이패스플러스카드 시험 모듈 개발)

  • Lee Ki-Han;Lee Dae-Kyu;Yeo Woonsang;Lee Seung-Hwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.2 no.2 s.3
    • /
    • pp.31-42
    • /
    • 2003
  • Prepaid plastic card issued by Korea Highway Company had a lot of problems in end-user usage and management. HipassPLUS Card, which is a smart card used for a prepaid electronic payment, overcomes the problems of Prepaid Plastic card. HipassPLUS Card is also designed be compatible to other cards such as public transportation card. Thus, for the safety of using the card in such environment, the functionality and the security of HipassPLUS card should be faultless. This paper developed a test module including the test method, the test checklist, and the test procedure to examine the functionality and security of the payment mechanism of HipassPLUS card. The test module contains the method and the procedure to test the standard items according to the test checklist of HipassPLUS card. The test items and the test checklist of HirassPLUS card was selected under the provision of the specification of Korea Highway Company and ISO standard. The results of evaluation on HipassPLUS card using the proposed test module indicates that 4he HipassPLUS card satisfied the criteria under the characteristics of the functionality, security, and compatibility.

  • PDF

Good Agricultural Practices (GAP) analysis of hazardous materials in button mushroom (Agaricus bisporus) (GAP 양송이버섯 재배를 위한 위해물질 분석)

  • Lee, Byung-Eui;Kim, Tae-Hyun;Lee, Chan-Jung;Kim, Yong-Gyun;Lee, Byung-Joo
    • Journal of Mushroom
    • /
    • v.15 no.4
    • /
    • pp.178-182
    • /
    • 2017
  • Good Agricultural Practices (GAP) is the world's leading quality certification for food safety. Since its introduction in Korea in 2006, its importance has been increasing every year. In particular, food safety issues are becoming increasingly important in society, and food safety is directly linked to health. The core of GAP certification is the traceability of the production, distribution, and consumption of hazardous materials, including pesticide residues, heavy metals, and microbes. In the present study, pesticides and heavy metals in button mushroom (Agaricus bisporus) and associated cultivation materials were analyzed. Tricyclozole (0.0144 ppm), flubendiamide (0.147 ppm), and trifloxystrobin (0.0340 ppm) were detected in rice straw and wheat straw, and carbendazim (0.0142 ppm) was detected in mixed wheat straw and rice straw medium. Lead and cadmium were detected at levels higher than the standard level in rice straw and mixed medium. However, lead and cadmium were not detected in mushrooms, and levels of arsenic and mercury were below the safety limit. Therefore, it was confirmed that the residual pesticides and heavy metals are safely managed in the investigated mushroom species. The results of the present study suggest that if these materials are adequately managed in the surroundings during cultivation, all hazardous materials can be managed during mushroom production.

Safety evaluation and approval status of genetically modified foods in Korea (국내 유전자변형식품 안전성 심사 규정 및 승인현황)

  • Kang, Yun-Sook
    • Food Science and Industry
    • /
    • v.52 no.2
    • /
    • pp.130-139
    • /
    • 2019
  • Safety of genetically modified foods (GM foods) in Korea is evaluated according to "Food Sanitation Act" and "Regulation on safety evaluation for GM foods" based on the concept of substantial equivalence. In which cases a person who imports, develops or manufactures GM foods for the purpose of eating imports GM foods for the first time, he/she shall undergo a safety evaluation of the relevant foods, etc. by Ministry of Food and Drug Safety (MFDS). And in which cases ten years have elapsed since GM foods underwent safety evaluation, they shall be re-evaluated for their safety. As of April 2019, a total of 199 events have been approved by MFDS and they are 169 events of GM crops including soybean (29), maize (87), cotton (29), canola (14), sugar beet (1), potato (4), alfalfa (5), 6 events of GM microorganisms (GMM) and 24 events of GM food additives originated from GMM.

A Study on the Safety Management Methods of Micro-Gas Engine Combined Heat and Power System (소형 가스엔진 열병합발전 시스템의 안전관리 방안에 관한 연구)

  • Kim, So-Hyun;Kim, Min-Woo;Lee, Eun-Kyung;Lee, Jung-Woon
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.76-89
    • /
    • 2018
  • The distribution of the combined heat and power system is active as a solution to the instability of energy supply and environmental pollution caused by continuous industrial development. In Korea, the safety standards for combined heat and power system using a gas engine are insufficient therefore the study on this is needed. In this study, the safety performance and structural/material assessment items of domestic and international standards applied to the combined heat and power system were analyzed to carry out a standardization study on safety performance applicable to 20 kW gas engine combined heat and power system. In addition, the safety performance assessment (plan) of the gas engine combined heat and power system was derived by performing risk analysis and risk assessment using HAZOP. Assessment items include engine ignition systems related to safety performance, piping tight performance, watering and temperature rise performance, combustion performance, electrical efficiency, thermal efficiency, overall efficiency and humidity performance. Gas and water pipes, gas control and shut-off valves, durability, heat resistance, and cold resistance of metal or non-metallic materials related to the structure and materials of the gas engine combined heat and power systems.

A Checklist and Manual Developed to Review Fire Safety Facilities' Compliance with Fire Safety Requirements for Apartment Buildings (공동주택 소방시설 적법성 검토를 위한 화재안전규정 체크리스트 및 매뉴얼 개발)

  • Jeong, Soo-jin;Park, Yoo-na;Kim, Jae-jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.6
    • /
    • pp.94-102
    • /
    • 2018
  • Recently, there is a growing need to review compliance with legal requirements to ensure fire safety as the number of fires caused by noncompliant fire safety facilities in high-rise buildings has increased. While there are a large number of apartment buildings in Korea, there is a lack of review on fire safety facilities' compliance with fire safety requirements. The reason for this lack of review despite apartment buildings causing deaths due to their structural features in the event of a fire, lies in the misinterpretation of legal provisions as the Building Act and the Fire Services Act are mixed up; a final inspection when fire safety facilities are unnecessarily installed or missing could result in significant losses in terms of finances and time. Therefore, this study developed a checklist that makes it possible to review mixed-up legal requirements for fire safety facilities simultaneously, and examined the importance and current level of each item through IPA (Importance Performance Analysis). Based on these results, this study intends to develop a manual that considers its applicability to construction practices and contribute to reducing construction companies' fire safety inspection risks.

Rationalizing Strategies for Children's Activity Spaces and Facilities (어린이 활동공간 및 놀이시설 제도 합리화 방안)

  • Park, Mi-Ok;Koo, Bon-Hak
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.4
    • /
    • pp.36-50
    • /
    • 2012
  • This study was carried out to find contradiction factors on laws for children's activity spaces and facilities and to suggest the rational options to control and manage those spaces and facilities by environmental and landscape planning methods. The results of this study are as follows: 1. The major laws related to the environmental safety for children's activity spaces are "Environmental Health Act (ERA)" for managing the environmental safety of children's activity spaces; "Safety Supervision Law of Children's Play Facilities(SSLCPF)" for the inspection and management for safety of children's play facilities; "Quality Management and Industrial Products Safety Management Law(QMIPSML)" for managing safety certification on children's play equipments. 2. The interior space such as "living room" by the Children's Welfare Law(CWL), "Children Park" by the Act on Urban Parks and Green Spaces(AUPGS), "classroom" on private educational institutes by the Act on Establishment and Operation Private Lesson and Training(AEOPLT) and "nursing room" of child care center smaller than $430m^2$ are needed to be managed as an activity space. 3. In order to reduce industrial burden in the production, establishment, construction, and operation and to minimize unwilling extra burden in the administration effort due to legally double regulate, it is necessary to mitigate the inspections on the equipment certificate from QMIPSML and overlapped or different factors and standards must be unified. With this study, the landscape domain could he enlarged from producing, import of play equipment and establishment, construction and operation of play facilities for a comprehensive range of activity spaces, and the landscape industry such as engineering industry, academic research, management, etc.

Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.

The Development of Quality Assurance Program for CyberKnife (사이버나이프의 품질관리 절차서 개발)

  • Jang, Ji-Sun;Kang, Young-Nam;Shin, Dong-Oh;Kim, Moon-Chan;Yoon, Sei-Chul;Choi, Ihl-Bohng;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Kwon, Soo-Il;Lee, Dong-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.185-191
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: Standardization quality assurance (QA) program of CyberKnife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for CyberKnife and evaluation of the feasibility under applications. $\underline{Materials\;and\;Methods}$: Considering the feature of constitution for systems and the therapeutic methodology of CyberKnife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two CyberKnife centers. The acceptable tolerance was based on the undertaking inspection list from the CyberKnife manufacturer and the QC results during last three years of two CyberKnife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. $\underline{Results}$: The current QA status of two CyberKnife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. $\underline{Conclusion}$: It is considered that the developed QA program in this research could be established the standardization of QC methods for CyberKnife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy.