• Title/Summary/Keyword: 안경점

Search Result 122, Processing Time 0.026 seconds

The Understanding of Determination of Horizontal Centration Point of Single-vision Reading Glasses (단초점 근용 안경의 수평방향 설계점 결정에 대한 이해)

  • Kim, Min Ho;Kim, Hyun-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: The purpose of this study is to compare degrees of asthenopia in after wearing of dispensed reading glasses with different criterion of P.D. Methods: The person who has minus near correction power (distance correction value (-)) is compared to the degree of asthenopia by wearing of dispensed reading glasses with near P.D(-B) and distance P.D. The person who has plus near correction power is compared to degree of asthenopia by wearing of dispensed reading glasses with near P.D-B, distance P.D, near P.D-A. The "Near-P.D-A" means reduced optical centre distance of reading glasses of positive correction value at which the same effect of prism B.O through near visual point in distance glasses exist at near visual point in reading glasses. Results: When near correction value is (-), dispensed reading glasses with distance P.D have caused less asthenopia than dispensed glasses with near P.D-B. When the near correction value is (+), we cannot confirm that which P.D is more useful for reading glasses. As a result of this study, dispensed reading glasses with near P.D-A have caused less asthenopia than another criterion of P.D. Conclusion: The effect of prism B.I through a near visual point in distance glasses ((-) correction value) reduce convergence demand. Therefore (-) correction value-reading glasses support convergence in near vision, because the effect of prism B.I of reading glasses is smaller than that of distance glasses. When the near correction value is (+), centration points can be determined by one of near P.D-A, near P.D-B, distance P.D.

  • PDF

The Examination of Refractive Correction and Heterophoria and Monocular Pupillary Distance on Myopic Elementary School Children Wearing Glasses in Gwangju City (광주지역 근시안경 착용 초등학생의 굴절상태와 사위 및 단안PD에 대한 조사)

  • Hwang, Kwang-Ha;Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.71-75
    • /
    • 2009
  • Purpose: This study was designed to investigate the condition of refractive correction and heterophoria and monocular pupillary distance on myopic elementary school children wearing glasses in Gwangju city. Methods: Subjective refraction and objective refraction were examined after investigating heterophoria and monocular pupillary distance on 145 (290eye) elementary school children wearing myopia-corrected glasses. Results: 1. Anisometropia > 2.00 D was present in 4 children (3%). 2. 9 anisometropia (47%) were present in 19 undercorrected visual acuity boy wearers. and 16 anisometropia (64%) were present in 25 undercorrected visual acuity girl wearers. 3. Among the 67 myopic glasses boy wearers, the distance between optical centers was coincided with the pupillary distance in 30% (Oculus Uterque), and discrepant in 70% (Oculus Uterque). Among the 78 myopic glasses girl wearers, the distance between optical centers was coincided with the pupillary distance in 23% (Oculus Uterque), and discrepant in 77% (Oculus Uterque). The mean optical center distance was longer than the pupillary distance on both boy and girl wearers 4. The result of measured heterophoria revealed 14% for orthophoria, 63% for exophoria, 23% for esophoria at far distance and 10% for orthophoria, 76% for exophoria, 14% for esophoria at near distance. Conclusions: Correct refractive test and monocular pupillary distance must be examined because incorrect refractive test and pupillary distance induce asthenopia and heterophoria.

  • PDF

Development of a Calculating Program for the Prism Power Influencing to Binocular Vision according to Shift of Binocular Visual Points in the Distance Vision Spectacles (원용안경의 양안 주시점 이동에 따른 양안시에 미치는 프리즘 굴절력 산출 프로그램 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.257-262
    • /
    • 2010
  • Purpose: Developing a calculating program for the prism power which influenced the binocular vision according to shifts of binocular visual points in the distance vision spectacles. Methods: By using the Delphi 6.0 programming language, we developed a calculating program of the relative binocular prism power according to the movements of binocular visual points in the distance vision spectacles, which was calculated by dragging the mouse along the traces of binocular visual points on the computer window. Results: We developed a calculating program for the relative binocular prism power according to the movements of binocular visual points in the distance vision spectacles. The user of the program could confirm the trace of visual points by allowing them to display the trace of binocular visual points on the computer screen with a mouse button. An application on confirming the variation of prism power by graphs in the program also allowed the user to use the program more conveniently. Conclusions: By using the developed program, the user could easily calculate the relative binocular prism power according to shifts of binocular visual points in the distance vision spectacles. We also found that the developed program helped the user to receive a lot of assistance in analyzing the asthenopia.

A Study on the Wearing Status of the Near Vision Refractive Error Correction Device for Presbyopia in Each Residential District (Chungcheongnam-do and Gyeonggi-do) (거주지별(충청남도와 경기도) 노안의 근거리 시력교정안경 착용 실태)

  • Kim, Jung-Hee;Lee, Young-Il;Kang, Su-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.103-108
    • /
    • 2009
  • Purpose: The objective of this study is to compare and analyze the wearing status of refractive error correction devices of elders who reside in a city or in a small town district. Methods: Each of opticians from a small town or a city was selected for the study of wearing status of presbyopia correction device for each residential district in units of percentage. with the analysis of the age and gender distributions of the elders, numbers of elderly members, and the kinds of presbyopia correction. Results: The wearing rate of progressive lens was reduced in reverse proportion to the increase of the age for the people of presbyopia in a twon. Pepople in 60s living in a town perferred to wearing bifocal lens, but people of 50~60s preferred to single vision lenses. However, none of people living in a city who is diagnosed as presbyopia had refractive error correction device, and no one used bifical lenses. The progressive lens was mostly used in the people of 40~50s and using rate of those lenses reduced with the age; and single vision lens had the highest rate of in the 40~50s but no one wore it in the 70s. Conclusions: Among the refractive error correction devices, the progressive lens was most widely worn by presbyopia group who is living in a town or a city. In particular, the refractive error correction devices were most preferred in 40~50s of early presbyopia. The highest preference for the progressive lens in the people with the early presbyopia indicates that the wearing rate of the progressive will be increased in future. Therefore, the opportunity of systematic education on the progressive lens should be increased.

  • PDF

A Plan to Improve Consumer Satisfaction and Reliability of Opticians by Analyzing Consumers' Spectacles Purchasing Behavior (소비자의 안경 구매 행태 분석을 통한 만족도 및 신뢰도의 향상 방안)

  • Park, Jee-Hyun;Lee, Eun-Hee;Koo, Eun-Hye;Kim, Hee-A;Song, Da-Hye;Hyun, Jin-Hee;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose: To plan and improve consumers' satisfaction by analyzing consumers' purchasing behavior of spectacles. Also this will show the need of improvement in reliance of an optician. Methods: A total of 307 people (10 to 60 years) participated in individual questionnaires. Questionnaires comprised of general characteristic of surveyed people, purchasing spectacles behavior, satisfaction after purchasing spectacles, reliability of optician, and improvement points of optician. Results: Most important points in selecting the product were the design and the price of the spectacles. 142 people (46.3%) replied "average" and 140 people (45.6%) replied "satisfying" out of maximum point of satisfaction level which was 5 points. 72.3% of people have regularly visiting optical shop due to the high accessibility, after-sales care, and courteous optician. On the contrary, 27.7% replied "never visit same optician shop again" because of the low accessibility, minimal range of products, and high price. Data showed that people had high re liability about the opticians' knowledge of product, and their technique of eye refraction. Data revealed that people did not show high satisfaction about opticians' knowledge of ophthalmology, and price of products. Most important improvement points were accurate spectacle prescription by Opticians rating 42% of reply. Factors most considered during spectacle selection among the 10 to 20 age group were design by 34.8% and price by 10.1%. Among the 40 to 50 age group, most considered factors were design by 14% and spectacle frame material by 10.1%. Conclusions: Satisfaction rate of purchasing spectacles for the total participant group was 4.2 average grades. Reliability of opticians' eye refraction result and prescription was 50.5%. However consumers wanted to obtain more accurate eye refraction result and prescription with more comprehensive explanations. Also, consumers wanted opticians to be sensitive and have appreciative eye in select spectacles for customers, and to offer precise spectacle dispensing services and courteous after-sales care.

Robust Glasses Detection using AAM and Anisotropic Smoothing (AAM 및 비등방성 펑활화를 이용한 안경 검출)

  • Jeon, Seung-Seon;Jo, Seong-Won;Jeong, Seon-Tae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.11a
    • /
    • pp.439-442
    • /
    • 2007
  • 강인한 얼굴 인식 시스템을 만들기 위해서는 안경의 제거가 중요한 요소이다. 이를 위해서는 뛰어난 성능의 안경 검출 방법이 필수적이다. 본 논문에서는 안경의 유무 판단에 관한 새로운 방법을 제안한다. 영상은 조명 부분과 반사부분의 곱으로 이루어져 있다. 얼굴의 경우 안경 고유의 반사계수와 얼굴 고유의 반사계수가 다른 점에 착안하여 anisotropic smoothing 방법을 이용하여 입력 얼굴 영상에서의 반사 부분을 얻고, 이를 이용하여 안경의 반사 부분을 얼굴의 반사부분에서 검출한 뒤 이진화한다. 이후, 이진화 된 안경 픽셀 수를 이용하여 안경의 유무를 판단한다.

  • PDF

The factors influencing the quantity of Phoria: I. A study of effects to the quantity of Phoria by the refractive error and the conformity to the optical center and the pupillary center (사위량에 영향을 미치는 요인: I. 굴절이상, 동공중심과 광학중심의 일치에 따른 연구)

  • Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.361-370
    • /
    • 2004
  • The purpose of this study was to evaluate the outcome and Factors that influence the quantity of Phoria in the low correction and perfect correction. Also the coincidence with the opticenter and the pupillary distance was a principal factor that influence the quantity of Phoria. Thereupon, this study is attributed to promote the perfect Phoria test. The subjects for this study were 120 persons(240 eye) in myopic refractive errors. ISP/WIN program was used for the data analysis. The collected data was analyzed by descriptive statistics and Spearman's correlation coefficient. The results of this study were as follows: 1. The prism pattern was difference between low correction and perfect correction in the Phoria test. The proportion of orthophoria was changed from 10.0% to 12.5%, exophoria was changed from 67.5% to 62.5%, and esophoria was changed from 22.0% to 32.5%, respectively. 2. The average of optical center distance and pupillary distance were 31.70mm and 31.49 mm, respectively. 3. Among the 120 myopic glasses wearers, the distance between optical centers was coincided with the pupillary distance in 37.5%, and discrepant in 62.5%. 4. For the patients who were coincided with the pupillary distance, the proportion of exophoria decreased 53.33%, esophoria increased 20.0%. 5. For the changing of the quantity of Phoria in the low correction, the degree of exophoria decreased 1.11 prism diopters in the perfect correction, esophoria increased 0.39 prism diopters.

  • PDF

다시점 3D 영상 기술

  • Eom, Gi-Mun;Kim, Tae-Won;Jang, Eun-Yeong;Sin, Hong-Chang;Jeong, Won-Sik;Heo, Nam-Ho
    • Information and Communications Magazine
    • /
    • v.28 no.6
    • /
    • pp.21-30
    • /
    • 2011
  • 본고에서는 안경식 3DTV가 가지고 있는 안경착용의 불편함을 해결할 수 있는 무안경 3DTV 개발을 위한 다시점 3D 영상 기술에 대해 기술한다. 다시점 3DTV 서비스를 위해서는 다시점 3D 영상 획득, 부호화 기술, 재현 및 디스플레이 기술 등의 개발이 필요하며, 본 고에서는 이들 기술에 대해 간략하게 소개하기로 한다.

The Case Studies on the interiors constituent of the Optical Store for adept VMD (VMD 적용을 위한 안경점의 실내 공간구성에 대한 사례연구)

  • Kim, Chang-Han;Kim, Yong-Rhip
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.05a
    • /
    • pp.122-125
    • /
    • 2005
  • The results analyzing the interior space of optician's store for application of VMD are as follows. The optician's stores tend to utilize their space not just for one function, but for multiple purposes. It is becoming bigger in size and is showing that it is spending more space for marketing purposes. In the future, optical store needs to provide convenience for the customers and as a Semi-Medical space, in order to receive trust, it needs to have Test-area, Work-area, improvement in environment, and of course, a comfortable space where the customers can sit back and relax. Taking a look at the features of design, the colors and the use of materials in domestic areas has been somewhat restricted. But international areas has been using diverse colors and materials for bright and comfortable atmosphere. Now, the optician's stores has to produce various atmosphere through different and brilliant colors and materials from other stores to be more efficient and to be highly competitive.

  • PDF

Analysis on Causes of Stagnation in Domestic Eyeglasses Industry (국내 안경산업의 침체원인 분석)

  • Lee, Jeong-Yeong;Park, Eun-Kyu;Kim, Dae-Nyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.43-47
    • /
    • 2006
  • Korean eyeglasses export has continuously decreased at the annual average rate of 10% since year 2000. On the other hand, China - the number 1 competing country - is chasing after Korea while accomplishing average 20% of export increase per annum after year 2000. Considering these factors, main cause of stagnation in domestic eyeglasses industry can be seen as China's pursuit propelled by their low labor costs as well as investment on Research &Development. Other important causes are insufficient investment on R &D, decrease in competitiveness due to increase of import, deficiency of exploitative ability on own brand and own design, lack of infrastructure in eyeglasses expo, and etc.

  • PDF