• Title/Summary/Keyword: 아크릴 프레임

Search Result 11, Processing Time 0.035 seconds

Development of Gas-mask Spectacles (방독면 안경 개발)

  • Lee, Jeung-Young;Parkm Jeong-Sik;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.9-12
    • /
    • 2008
  • Purpose: Current gas-mask is very uncomfortable structure for spectacles wearer. Improving this problem can aid military men and firemen to protect themselves and rescue other person. Methods: we changed the structure from dual type of outward lens and inward lens into a single type structure. we attached acrylic frame to gas-mask instead of outward lens and protected the gas inflow by shutting the gab of lens and frame using silicon shield, and made the frame "S" style for removing astigmatism and maintaining of vertex distance. Results: It was possible to correct visual acuity and gas shield, and could changed the lens like a common spectacles. The new type of gas-mask spectacles could remove 0.53D~1.78D astigmatism occurred from the slant of eyesight and lens surface, 0.07D~0.66D overcorrection occurred from short vertex distance, and 0.1D~0.3D astigmatism occurred from pantoscopic angle. Conclusion: Because new type of gas-mask spectacles had clear visual field, it was expected to improve fighting power and rescue ability.

  • PDF

Adhesive Properties of Epoxy Composite According to the Surface Treatment of Cu Substrate and Adhesion Promoter Content (구리기판의 표면처리 및 접착증진제 함량에 따른 에폭시 컴포지트의 접착특성)

  • Eun-jin Kim;Jung Soo Kim;Young-Wook Chang;Dong Hyun Kim
    • Journal of Adhesion and Interface
    • /
    • v.23 no.4
    • /
    • pp.108-115
    • /
    • 2022
  • In this study, we synthesized poly(itaconic acid-co-acrylamide) (IAcAAM) used as a novel polymer adhesion promoter to improve the adhesion strength of surface-treated Cu lead frames and epoxy composites. IAcAAM comprising itaconic acid, acrylamide was prepared through radical aqueous polymerization. The chemical structure and properties of IAcAAM was analyzed by FT-IR, 1H-NMR, GPC, and DSC. The surface of the copper lead frame was treated with high temperature, alkali, and UV ozone to reduce the water contact angle and increase the surface energy. The adhesive strength of Cu lead frame and epoxy composite increased with the decrease of contact angle. The adhesive strength of Cu lead frame/epoxy composite increased with the addition of IAcAAM in epoxy composite. As silica content increased, the adhesive strength of Cu lead frame and epoxy composite tended to slightly decrease.

Development of A Fractionated Stereotactic Radiotherapy System (분할 정위방사선 치료 시스템 개발 연구)

  • 이동한;지영훈;이동훈;조철구;김미숙;유형준;류성렬
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2002
  • We invented the newly developed Fractionated Stereotactic Radiotherapy(F.S.R.T) system using combined techniques of couch mounting and pedestal mounting system. Head fixation frame consists of a milled alluminium alloy(duralumin) and is placed to the couch. This frame immobilized patient head using the dental bite, 3.2 mm frontal and occipital thermoplastic mask. To evaluate the coordinate of target isocenter, Brown-Revert-Walls C.T localizer can be attached to this frame. And also, we developed the frame mounting system by developing the modification of pedestal mounting system. This system is fixed to couch floor and can be used to evaluate the isocenteric accuracy of gantry, couch and collimator in Q.A procedure. In order to measure the relocation accuracy, the acrylic phantom and the accurate pointers have been made. The repositioning of the targets in the phantom were estimated by comparing C.T coordinates and E.C.L portal films taken with anterior-posterior and right-left direction. From the results of experiments, the average distance errors between the target isocenter and its mean position were 0.71$\pm$0.19 for lateral, 0.45$\pm$0.15 for inferior-superior, 0.63$\pm$0.18 for anterior-posterior. And the maximum distance error was less than 1.3 mm. The new head fixation frame and frame mounting system were non-invasive, accurately relocatable, easy to use, very light and well tolerable by the results of phantom tests. The major advantage of using this frame mounting system is complete access to any point in the Patients cranium especially posterior direction

  • PDF

Soil Deformation Tracking in Model Chamber by Targetless Close-Range Photogrammetry (무타겟 사진측량 기반 모형 토조 내 지반 변위 측정)

  • Lee, Chang No;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.6
    • /
    • pp.555-562
    • /
    • 2019
  • This paper presents soil deformation measurement in model chamber based on photogrammetry. We created an aluminum framed acrylic model chamber with soil inside and applied photogrammetry to measure soil deformation caused by loading tests. The soil consists of 40% black and 60% regular sand to create image contrast in soil images. In preprocessing, the self camera calibration was carried out for IOPs (Interior Orientation Parameters), followed by the space resection to estimate EOPs (Exterior Orientation Parameters) using control points located along the aluminum frame. Image matching was applied to measure the soil displacement. We tested different matching window sizes and the effect of image smoothing. Experimental results showed that 65x65 pixels of window size produced better soil deformation map and the image smoothing was useful to suppress the matching outliers. In conclusion, photogrammetry was able to efficiently generated soil deformation map.

Flow Visualization in the Branching Duct by Using Particle Imaging Velocimetry (입자영상유속계를 이용한 분기관내 유동가시화)

  • No, Hyeong-Un;Seo, Sang-Ho;Yu, Sang-Sin
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.29-36
    • /
    • 1999
  • The objective of this study is to analyse the flow field in the branching duct by visualizing the flow phenomena using the PIV system. A bifurcation model is fabricated with transparent acrylic resin to visualize the whole flow field with the PIV system. Water was used as the working fluid and the conifer powder as the tracer particles. The single-frame and two-frame methods of the PIV system and 2-frame of the grey level correlation method are applied to obtain the velocity vectors from the images captured in the flow filed. The velocity distributions in a lid-driven cavity flow are compared with the so-called standard experimental data, which was obtained from by 4-frame method in order to validate experimental results of the PIV measurements. The flow patterns of a Newtonian fluid in a branching duct were successfully visualized by using the PIV system and the sub-pixel and the area interpolation method were used to obtain the final velocity vectors. The velocity vectors obtained from the PIV system are in good agreement with the numerical results of the 3-dimensional branch flow. The results of numerical analyses and the PIV experiments for the three-dimensional flows in the branch ing duct show the recirculation zone distal to the branching point and the sizes of the recirculation length and height of the tow different methods are in good agreement.

  • PDF

Analysis of Acquisition Parameters That Caused Artifacts in Four-dimensional (4D) CT Images of Targets Undergoing Regular Motion (표적이 규칙적으로 움직일 때 생기는 4DCT 영상의 모션 아티팩트(Motion Artifact) 관련된 원인분석)

  • Sheen, Heesoon;Han, Youngyih;Shin, Eunhyuk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.243-252
    • /
    • 2013
  • The aim of this study was to clarify the impacts of acquisition parameters on artifacts in four-dimensional computed tomography (4D CT) images, such as the partial volume effect (PVE), partial projection effect (PPE), and mis-matching of initial motion phases between adjacent beds (MMimph) in cine mode scanning. A thoracic phantom and two cylindrical phantoms (2 cm diameter and heights of 0.5 cm for No.1 and 10 cm for No.2) were scanned using 4D CT. For the thoracic phantom, acquisition was started automatically in the first scan with 5 sec and 8 sec of gantry rotation, thereby allowing a different phase at the initial projection of each bed. In the second scan, the initial projection at each bed was manually synchronized with the inhalation phase to minimize the MMimph. The third scan was intentionally un-synchronized with the inhalation phase. In the cylindrical phantom scan, one bed (2 cm) and three beds (6 cm) were used for 2 and 6 sec motion periods. Measured target volume to true volume ratios (MsTrueV) were computed. The relationships among MMimph, MsTrueV, and velocity were investigated. In the thoracic phantom, shorter gantry rotation provided more precise volume and was highly correlated with velocity when MMimph was minimal. MMimph reduced the correlation. For moving cylinder No. 1, MsTrueV was correlated with velocity, but the larger MMimph for 2 sec of motion removed the correlation. The volume of No. 2 was similar to the static volume due to the small PVE, PPE, and MMimph. Smaller target velocity and faster gantry rotation resulted in a more accurate volume description. The MMimph was the main parameter weakening the correlation between MsTrueV and velocity. Without reducing the MMimph, controlling target velocity and gantry rotation will not guarantee accurate image presentation given current 4D CT technology.

Development of Patient-Immobilizing Device for Total Body Irradiation (TBI) (전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구)

  • 김명세
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.114-119
    • /
    • 2002
  • A immobilizing device that is essential for correct lung and lens shielding with homogenous dose distribution in fractionated total body irradiation was developed and it's efficiency was evaluated. The main frame was made of stainless steel bar (5 cm in diameter) to withstand up to 230 cm in height and 100 kg in weight to prevent any injury even in unconsciousness condition. The saddle was designed to adjust the body weight and hight of standing patients. Chest and back supporter were made of 1 cm acryl which could fix the lung block and cassette holder. Leather and sponge pedding were used for head rest to keep patients comfortable. The device was strongly fixed by specially designed bolts on the bottom panel which was made of 1 cm stainless steel and 10 cm thick wooden board. Precise manipulation ($\pm$2 mm) was possible by upper two pulleys and side handles. Average four minutes twenty five seconds were needed for exact setting in fractionated TBI. No significant difference of lung block location on repeated verification films was confirmed and relatively homogeneous dose distribution was measured in rando phantom experiments and patient treatments ($\pm$5%). This immobilizing device was very efficient to keep correct position of patients, which is essential for better result and less complication in fractionated TBI.

  • PDF

External Fixation with Acrylic Frame in Forelimb Fracture of Korean Native Two Calves (한우송아지의 전지골절에서 아크릴릭 프레임을 이용한 외부고정)

  • Shin, Sang-Min;Lee, Dong-Bin;Lee, Hae-Beom;Kim, Min-Su;Ji, Joong-Ryong;Kim, Nam-Soo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.179-182
    • /
    • 2011
  • Two day-old male and 1 month-old female Hanwoo calves presented to Chonbuk Animal Medical Center in Chonbuk National University. Two calves were stepped by mother cow and had right (2 day-old male) and left (1 month-old female) forelimb lameness. The male calf was diagnosed as right radius-ulnar fracture through physical and radiographic examination. The other female calf was diagnosed as left third and fourth metacarpal bone fracture by the same examinations as male calf. Acrylic frame external fixator was used to reduce the fractures. Arcrylic frame external fixator in two calves lasted for 5~6 weeks. After removing the acrylic frame external fixator, radiographic evaluation and physical examination were performed. Fractured radius-ulnar and metacarpal bones were unionized and the calves were able to stand and bear weight. In these two calves, application of acrylic frame external fixator in calf fracture was effective. Acrylic frame external fixator should be considered for the repair of radius-ulnar and metacarpal bone fracture in calf.

Assessment of Imaging Distortion in Magnetic Resonance Imaging for Stereotactic Radiosurgery: Through Phantom Study (뇌정위 방사선수술 시스템을 위한 자기공명영상의 공간적 왜곡의 측정 : 모형실험을 통한 연구)

  • 박선원;한문희;김동규;정현태;송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.7-13
    • /
    • 2000
  • Purpose : To assess the distortion of MRI with the Leksell stereotactic radiosurgery system in variable pulse sequence and imaging plane through phantom study, to find most adequate imaging plane and pulse sequence for stereotactic radiosurgery system. Materials and methods : We made the phantoms for MRI and get images in variable conditions and analyzed the image distortion using image analysis program, and statistically using paired student t-test. Results : The transeverse plane images had acceptable error ranges bless than 1.5mm) in all pulse sequence in both the analysis of fiducial marker in stereotactic G-frame and the phantom study. The coronal plane images had unacceptable large errors (more than 1.7mm) in the analysis of fiducial marker in the stereotactic G-frame, but had corrected small errors (less than 1.5mm) in the phantom study. Conclusion : We find from the phantom study that the present MR machines are adequate for stereotactic surgery system in frequently used pulse sequences, and imaging planes.

  • PDF

수박 밀도 실시간 계측시스템 개발

  • 최규홍;최동수;이강진;손재룡
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.04a
    • /
    • pp.126-127
    • /
    • 2003
  • 원예산물의 밀도나 비중은 내부성분, 숙도, 내부붕괴(internal breakdown)와 같은 생리장해에 큰 영향을 받기 때문에, 밀도를 측정함으로써 내부품질에 대한 간접적인 판정이 가능하다고 보고되고 있다. 이 연구는 수박의 밀도와 당도와의 상관관계를 구명하고자 수행하였으며, 이를 위해 밀도의 실시간 계측시스템을 개발하였다. 현재 농산물의 밀도를 어느 정도 측정 정밀도를 유지하면서도 신속하게 측정할 수 있는 방법은 부력법(platform scale method)이다. 이 방법은 일정 크기의 용기에 물을 가득 채운 후 대상물을 담가 배제된 물의 무게를 측정하여 밀도를 환산한다. 그러나 매번 측정할 때마다 물을 보충하고, 물을 계량해야하는 등 전처리과정이 복잡하고, 1회 측정하는데 3~5분 정도가 소요되는 단점이 있고, 또한 인력 측정시 반복간 오차가 클 것으로 예상된다. 따라서 이 연구에서는 이 같은 계측상의 번거로움을 해소하고 동시에 신속하고 반복간 측정정밀도를 높일 수 있도록 수박 밀도 실시간 계측시스템을 설계 제작하였다. 시스템은 투명아크릴 수조($\Phi$400$\times$500), 로드셀, 프레임, 채반, 전기모터, 제어장치 및 컴퓨터로 구성하였다. 밀도 계측은 인장형 로드셀(CAS SB-20L, Max. 20kg)을 사용하여 대기중에서와 수박을 완전히 물에 잠기도록 한 후 무게를 각각 측정하여 밀도를 환산하였다. 밀도 계측시스템에 이용한 AD변환기의 분해능은 12bit이고, 수박의 무게 측정범위를 4~10kg로 가정할 때 20kg 로드셀의 1 digit(1bit)로 발생되는 오차는 0.09~0.24%FS 이었고, 따라서 이 시스템의 밀도 해상도는 0.001g/㎤이하였다. 시스템 평가를 위해 탄력이 좋은 고무풍선에 수박 크기 정도로 물을 채워 고정채반에 넣고 밀도를 측정한 결과 1.002g/㎤을 나타냈다. 즉 물의 이론밀도인 1g/㎤에 근접한 값을 보여 정확한 밀도 계측이 가능한 것으로 판단되었다. 또한 밀도 계측시스템의 측정 반복간 정밀도를 파악하기 위해 수박 6개를 임으로 선정하여 3반복 측정 시험한 결과, 측정표준편차가 0.001~0.004g/㎤로 해상도보다는 다소 높았으나 대체로 양호한 결과를 나타냈다. 수박 35개를 이용하여 개발 계측시스템과 사람이 직접 부력법으로 밀도를 측정 비교한 결과, 계측시스템에 의해 측정된 수박 밀도가 사람이 측정했을 때 보다 낮게 측정되었다. 수박의 외관인자(무게, 길이, 직경, 체적), 밀도와 당도의 상관관계 구명시험을 위해 원예연구소 시험포장에서 재배된 삼복꿀수박 총 74개를 공시재료로 하였고, 시험은 출수일별로 10~14개씩 수확하여 외관인자, 밀도, 당도를 각각 측정하고, 이들 인자들간의 상관관계를 구명하였다. 외관인자들간에는 높은 상관관계를 보였으나, 외관인자들과 밀도, 외관인자들과 당도, 밀도와 당도와는 매우 낮은 상관관계를 나타냈다.

  • PDF