• Title/Summary/Keyword: 아이솔레이터

Search Result 37, Processing Time 0.025 seconds

Magnetic Characteristics of YIG ferrites with Sintering Temperature (소결온도에 따른 YIG 페라이트의 자기적 특성)

  • 양승진;윤종남;최우석;김정식
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.1
    • /
    • pp.65-69
    • /
    • 2003
  • Microstructural and electromagnetic properties of YIG ferrites, (Y, Ca)-(Fe, V, In, Al)-O for Isolator/Circulator were investigated with the sintering temperature. YIG ferrites of $Y_{2.1}Ca_{0.9}Fe_{4.4}V_{0.5}In_{0.05}Al_{0.05}O_{12}$ were fabricated by sintering at $1300^{\circ}C$, $1330^{\circ}C$, $1350^{\circ}C$, $1370^{\circ}C$. Crystallographic and microstructural properties were measured using XRD and SEM. Saturation magnetization$(4{\pi}M_s)$ were measured using VSM, and FMR(Ferromagnetic Resonance) experiment was conducted to measure ferromagnetic resonance line width$({\Delta}H)$. Microwave characteristics of YIG ferrites were measured using a Network Analyzer. The YIG ferrite of $Y_{2.1}Ca_{0.9}Fe_{4.4}V_{0.5}In_{0.05}Al_{0.05}O_{12}$, sintered at $1350^{\circ}C$, showed higher density, saturation magnetization and lower ferromagnetic resonance line width than those sintered at any other temperature.

  • PDF

A Study on the Magnetic Properties of YIG Ferrites with Zr-Substitution (Zr치환에 따른 YIG계 페라이트의 자기적 특성 연구)

  • 양승진;윤종남;김정식
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.5
    • /
    • pp.428-433
    • /
    • 2003
  • In this study, we investigated the variation of microstructural and electromagnetic properties of YIG ferrites for Isolator/Circulator application with the sintering temperature and Zr addition. The composition of the ferrites was Y$_{2.1}$Ca$_{0.9}$Fe$_{4.4-x}$V$_{0.5}$In$_{0.05}$Al$_{0.05}$Zr$_{x}$O$_{12}$ with x=0, 0.05, 0.1 and 0.2. The YIG ferrites were prepared by the conventional ceramic sintering process. The Zr-substituted YIG ferrite, Y$_{2.1}$ Ca$_{0.9}$Fe$_{4.4-x}$V$_{0.5}$In$_{0.05}$Al$_{0.05}$ Zr$_{x}$O$_{12}$ showed the highest saturation magnetization (1097 gauss) at x=0.1. The microwave properties were shown as isolation of 18.60 dB and insertion loss of 0.45 dB at x=0.2. Additionally, Zr-substitution was effective in decreasing ferromagnetic resonance linewidth with Zr content.

Physiological Evaluation of Cloned Mini-pigs in a Transportable Isolator for the Study of Xenotransplantation (바이오장기 연구를 위한 이동식 아이솔레이터 내 복제 미니 돼지의 생리 활성 평가)

  • Kim, Hae-Sung;Jeon, Yu-Byeol;Kwak, Seong-Sung;Jeong, Seung-A;Jung, Eui-Man;Hyun, Sang-Hwan;Jeung, Eui-Bae
    • Journal of Embryo Transfer
    • /
    • v.26 no.3
    • /
    • pp.165-169
    • /
    • 2011
  • The present study investigated the physiological evaluation of cloned mini-pigs in a transportable isolator. Transportable isolator was designed and manufactured by our research team for transporting gnotobiotic pig. Until now, no previous reports are available regarding the physiological activities and harmful effects when pigs were transported in this isolator. Five cloned mini-pigs of 1~2 year (s) old female with a body weight between 80~90 kg were used. The effects of transportable isolator on stress-related hormone, adrenocorticotrophic hormone (ACTH) and cortisol levels, and heart rate were evaluated. In addition, it was also examined the effects of transportable isolator on blood chemistry factors (alanine aminotransferase: ALT, aspartate aminotransferase: AST, blood urea nitrogen: BUN, glucose, and creatinine). Blood was sampled just before the beginning of transport (T0), at the end of transport (30min after the transport; T1), and 30 min after the end of transport (T2). At the same time, heart rate was also evaluated. As a result, heart rate had no significant (p>0.05) differences at the various-time points of study (T0, T1, T2). However, heart rate was slightly higher than normal range in T1 and T2. The ACTH level was higher than normal range. Whereas, the cortisol level was lower than normal range. There were no statistical significant differences both ACTH and cortisol level between different time groups. Also, there were no significant differences in blood chemistry factors. Therefore, our present study shows that transportable isolator has no harmful effect on stress and physiological condition in cloned mini-pigs.

PLL System of a Millimeter-Wave Band Receiver using YIG VCO (YTG VCO를 이용한 밀리미터파 대역 수신기의 PLL 시스템 연구)

  • Lee Changhoon;Chung M. H.;Kim K. D.;Kim H. R.
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.45-52
    • /
    • 2005
  • In this paper, we propose the PLL system of the local oscillator system for the millimeter wave band's radio astronomy receiving system. The development of the proposed local oscillator system based on the YIG oscillator VCO with $26.5\~40GHz$ specification. This system consists of the oscillator part including the YIG VCO, the harmonic mixer, and the isolator, the RF processing part including the triplexer, limiter, and RF discrimination processor, and the PLL system including YIG modulator and controller. Based on this configuration, we verify the frequency and power stability of the developed local oscillator system according to some temperature variation. From this test results we confirm the stable output frequency and power characteristic peformance of the developed LO system at constant temperature.

LNB Design and Fabrication for Flyaway Satellite Terminal (운반형 위성단말 저잡음 하향 주파수변환기 설계 및 제작)

  • Kim, Joo-Yeon;Shin, Kwan-Ho
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.81-89
    • /
    • 2020
  • This paper describes the design and fabrication of a LNB(Low Noise Block downd-converter) which is a component of a FST(Flyaway Satellite Terminal), one of the ET(Earth Terminal) of the military satellite. LNB is physically composed of an down-converter module, a low noise amplifier module, a transmit band suppression filter, a isolator, a housing, and a cable assembly. It was designed using simulator (AWR) to satisfy the electrical characteristics of LNB's such as gain, noise figure and unwanted signal. The gain and noise figure characteristics were measured at 61.4dBm and 1.37dB, respectively. The unwanted wave was measured at -66.79dBc. Of the electrical requirements of Table 1, not only the above three but also all other items were confirmed to be satisfied.

The Study on the Additives and Magnetic Property of YIG Ferrites for Circulator/Isolator (서큘레이터/아이솔레이터용 YIG 페라이트의 첨가제와 자기적 특성 연구)

  • 윤휘영;유승규;이수형;윤종남;김정식
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.12
    • /
    • pp.1155-1161
    • /
    • 2001
  • Yittrium Iron Garnet(YIG) has been used as an important material in the circulator/isolator which is used in RF communication system, mobile phone, adn satellite broadcasting, etc. In this study, we investigated the microstructural and magnetic properties of YIG ferrites with the sintering temperature and additives. We fabricated the YIG ferrites substituted with Ca, In, V by the traditional ceramic sintering method at 1250$\^{C}$, 1275$\^{C}$, 1300$\^{C}$ and 1325$\^{C}$. Powders were granulated by using a spray dryer. Crystallographic and microstructural properties were measured by using XRD and SEM. Magnetic properties were measured by using a VSM for saturation magnetization (4$\pi$M$\_$s/) and FMR (Ferromagnetic Resonance) experiment for ferromagnetic resonance line width (△H). The YIG ferrite, Y$\_$1.6/Ca$\_$1.4/Fe$_4$V$\_$0.7/In$\_$0.3/O$\_$12/, sintered at 1300$\^{C}$, showed higher saturation magnetization and lower ferromagnetic resonance line width than any other sintering temperatures.

  • PDF

A Study on the Improvement of Gamma Ray Energy Spectrum Resolution through Electrical Noise Reduction of High Purity Ge Detector (고순도 Ge 검출기의 전기적 노이즈 감소를 통한 감마선 에너지 스펙트럼의 분해능 향상에 관한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.849-856
    • /
    • 2020
  • In the gamma-ray energy spectrum study, nuclide analysis through energy analysis is very important. High-purity Ge detectors, which are commonly used for gamma-ray energy measurements, are commonly used because of their high energy resolution and relatively high detection efficiency. However, in order to maintain a high energy resolution, the semiconductor detector has a problem in that it is difficult to maintain the original performance if the noise generated from the surrounding environment is not effectively blocked, and the effect of the expensive device is not achieved. Therefore, in this study, ground loop isolator (NEXT-001HDGL) was used to remove the electrical noise generated from the detector. In order to test the effect of improving energy resolution, HPGe detection device newly installed in the proton accelerator KOMAC was used. In the case of gamma-ray energy 2614 keV, the energy resolution was improved from (0.16 ± 0.02) % to (0.11 ± 0.01) %, and in the case of gamma-ray energy 662 keV of 137Cs isotope, the energy resolution was improved from (0.72 ± 0.07) % to (0.27 ± 0.03) %. This result is considered to be very useful for the gamma ray spectrum study using the HPGe detection equipment of KOMAC(Korea Multi-Purpose Accelerator Complex).