• Title/Summary/Keyword: 심장CT

Search Result 415, Processing Time 0.023 seconds

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

A Case of Trisomy 8 Mosaicism in a Patient with Secondary Amnorreha without Abnormal Phenotype (속발성 무월경 외 비정상 표현형이 없는 Trisomy 8 Mosaicism의 증례 보고)

  • Kang, Hye-Sim;Son, Young-Soo;Kim, Sung-Yob;Park, Chul-Min;Shim, Soon-Sup
    • Journal of Genetic Medicine
    • /
    • v.8 no.1
    • /
    • pp.67-70
    • /
    • 2011
  • Constitutional trisomy 8 mosaicism (CT8M) is a relatively rare aneuploidy in humans with characteristic phenotypes including typical craniofacial feature (such as deformed skull, prominent forehead, low-set and/or dysplastic ears), skeletal malformation, cardiac anomaly, renal malformation, cryptochidism, varying degree of developemental delay. Due to the extremely variable phenotypic and cytogenetic expression, CT8M has gone undiagnosed in certain patients. We report a 28-year-old women with secondary amenorreha without characteristic CT8M phenotype. Chromosomal analysis showed a CT8M (47,XX,+8[9]/46,XX[41]).

A Change in an Absorbed Dose of the Heart in General and Respiratory Control Radiation Treatment Plans (일반 및 호흡조절 방사선치료계획에서 심장의 흡수선량 변화)

  • Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.313-319
    • /
    • 2018
  • In radiation treatment, it is unavoidable to block the influence of scattered ray on a skin and prevent internal normal organs from being exposed to radiation. It is fair to say that radiation therapy aims to reduce an absorbed dose of normal tissues. In particular, in radiation therapy of left-sided breast cancer, the internal neighboring organs are normal breast tissues, the heart, and the lung. The side effects on the heart include cardioplegy and myocardial infarction. This study tried to observe changes in the volume and dose of the heart in general radiation therapy plan and respiratory control based radiation therapy plan for patients with left-sided breast cancer, and to find the heart's volume and dose generated by respiration. According to the 4D computer tomography (CT), a volume of the heart had $12.8{\pm}8.7cc$ on average, and its dose had $17.3{\pm}12.1cGy$ on average. The differences in the volume and dose may cause side effects in radiation treatment. Therefore, it is necessary to apply respiratory control technique to establish the radiation treatment plan based on an accurate position of the heart.

Primary Cardiac Lymphoma : 1 Case Report (원발성 심장 림프종 : 1례 보고)

  • Bae, Jun-Ho;Lee, Jong-Suk;Kim, Hyung-Jun;Kim, Min-Kyung;Park, Young-Ho;Hong, Gue-Ru;Park, Jong-Sun;Sin, Dong-Gu;Kim, Young-Jo;Sim, Bong-Sup
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.1
    • /
    • pp.82-86
    • /
    • 2000
  • Primary cardiac lymphoma, defined as involving only the heart and pericardiwn, is very rare and is diagnosed predominantly late in the course of illness or autopsy. This tumor is commonly fatal and until recently were rarely diagnosed antemortem. Recently, it was reported in patients with acquired immunodeficiency syndrome. We report a case of primary cardiac lymphoma in a 56 year old female who showed progressive exertional dyspnea. On echocardiogram and CT scan, a large ill defined mass was demonstrated in right atrial and ventricular wall. It was diagnosed as B-cell type lymphoma on open cardiac biopsy.

  • PDF

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

Differentiation between Morgagni Hernia and Pleuropericardial Fat with Using CT Findings (CT 소견을 이용한 Morgagni 탈장과 심막주위지방의 감별)

  • Kim Sung-Jin;Cho Beum-Sang;Lee Seung-Young;Bae Il-Hun;Han Ki-Seok;Lee Ki-Man;Hong Jong-Myeon
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.573-578
    • /
    • 2006
  • Background: Generally hernia is diagnosed with simple chest or gastrointestinal x-ray. Sometimes CT or MRI can give lots of information for the diagnosis. However, there was no study for the differentiation with using CT findings between Morgagni hernia and pleuropericardial fat. The aim of this study was to evaluate the useful CT findings for differentiating Morgagni hernia from pleuropericardial fat. Material and Method: We retrospectively analyzed CT scans of eight patients with Morgagni hernia and 20 patients with abundant pleuropericardial fat without peridiaphragmatic lesions. All CT scans were performed with coverage of the whole diaphragm in the inspiration state. We evaluated 1) the presence of the defect of the anterior diaphragm, 2) the interface between the lung and fat, 3) the angle between the chest wall and fat, 4) the continuity between the extrapleural fat and fat, 5) the presence of the vessels within fat, and 6) the presence of a thin line surrounding fat. Result: In all cases with Morgagni hernia, the defect of the anterior diaphragm was seen. The interface was well-defined, smooth, and convex to the lung. The angle with the chest wall was acute. The continuity with the extrapleural fat was not seen. In the cases with abundant pleuropericardial fat, the defect of the anterior diaphragm was seen in three (15%). The interface was usually irregular (n=10) and flat (n=17). The angle with the chest wall was variable. The continuity with the extrapleural fat, that was markedly increased in amount, was usually seen (n=16). The thin line surrounding fat was seen in four cases with Morgagni hernia, however, not seen in all cases with pleuropericardial fat. All of the above findings were statistically significant, however, vessels within fat was not significant to differentiate Morgagni hernia (n=8/8) from pleuropericardial fat (n=14/20). Conclusion: The useful CT findings of Morgagni hernia were fatty mass with sharp margin, convexity toward lung, acute angle with chest wall, and thin line surrounding hernia. Branching structure within fatty mass representing omental vessels that has been known as a characteristic finding of Morgagni hernia was not useful for differentiating Morgagni hernia from pleuropericardial fat.

Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer (조기유방암환자의 이차원치료계획과 삼차원치료계획의 방사선조사범위의 차이)

  • Jo, Sun-Mi;Chun, Mi-Son;Kim, Mi-Hwa;Oh, Young-Taek;Kang, Seung-Hee;Noh, O-Kyu
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • Purpose: Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Materials and Methods: Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inframammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. Results: The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. Conclusion: The use of 3D CT based planning reduced the radiation field in early breast cancer patients with small breasts in relation to conventional planning. Though a coherent definition of the breast is needed, CT-based planning generated the better plan in terms of reducing the irradiation volume of normal tissue. Moreover it was possible that 3D CT based planning showed better CTV coverage including postoperative change.

Staging of Esophageal Cancer Using Positron Emission Tomography : Comparing to Computed Tomography (양전자방출단층촬영술(PET)을 이용한 식도암 환자의 병기 결정 -전산화단층촬영술(CT)과의 비교-)

  • 심영목;박승준;김병태;김성철
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.388-393
    • /
    • 1999
  • Background: Correct preoperative staging of esophageal cancer is a prerequisite for adequate treatment. We prospectively compared the accuracy of positron emission tomography (PET) with [fluorine-18]FDG in the staging of esophageal cancer to that of computed tomography (CT). Material and Method: The findings of FDG PET and of chest CT including lower neck and the upper abdomen of 20 biopsy-proven squamous cell carcinoma patients (male, 19; female, 1; mean age, 61) were compared with the pathologic findings obtained from a curative esophagectomy with lymph node dissection. Result: The sensitivities of FDG PET and CT for diagnosis of primary tumor were the same, 90.0% (18/20). Both FDG PET and CT failed to show the primary tumor in 2 of 20 patients; one had a 1cm sized carcinoma in situ and the other had T1 stage cancer. By using the results of the pathologic examinations of 193 removed lymph node groups, we calculated the diagnostic sensitivities, specificities and accuracies of PET and CT (*$\chi$2 p < 0.005). Sensitivity** Specificity Accuracy* PET 55.6%(30/54) 97.1%(135/139) 85.5%(165/193) CT 13.0%(7/54) 98.6%(137/139) 74.6%(144/193) One of four patients with a false-positive for PEThad had active pulmonary tuberculosis. Among the 24 tumor involved lymph node groups, PET failed to show tumor metastasis in 5 lymph node groups abutting the tumor and in 14 lymph node groups located where the decay correction was not performed. Conclusion: Based on the above findings, it is suggested that [F-18]FDG-PET is superior to CT in the detection of nodal metastases and in the staging of patients with esophageal cancer.

  • PDF

Surgical Repair of a Traumatic Tracheobronchial Injury in a Pediatric Patient Assisted with Venoarterial Extracorporeal Membrane Oxygenation

  • Suh, Jee Won;Shin, Hong Ju;Lee, Chang Young;Song, Seung Hwan;Narm, Kyoung Sik;Lee, Jin Gu
    • Journal of Chest Surgery
    • /
    • v.50 no.5
    • /
    • pp.403-406
    • /
    • 2017
  • Tracheobronchial rupture due to blunt chest trauma is a rare but life-threatening injury in the pediatric population. Computed tomography (CT) is not always reliable in the management of these patients. An additional concern is that ventilation may be disrupted during surgical repair of these injuries. This report presents the case of a 4 -year-old boy with an injury to the lower trachea and carina due to blunt force trauma that was missed on the initial CT scan. During surgery, he was administered venoarterial extracorporeal membrane oxygenation (ECMO). Although ECMO is not generally used in children, this case demonstrated that the short-term use of ECMO during pediatric surgery is safe and can prevent intraoperative desaturation.