• Title/Summary/Keyword: 심장 판막

Search Result 786, Processing Time 0.021 seconds

Left Ventricular Pseudoaneurysm after Surgery for Infective Endocarditis with Annular Abscess - A case report - (판막륜 농양을 동반한 감염성 심내막염 수술 후 발생한 좌심실 가성류 - 치험 1예 -)

  • 황호영;김기봉
    • Journal of Chest Surgery
    • /
    • v.36 no.4
    • /
    • pp.273-276
    • /
    • 2003
  • We report a surgical case of 39-year-old male with a pseudoaneurysm of the left ventricle. Four years ago, the patient underwent aortic and mitral valve replacements with mechanical valves and abscess removal for infective endocarditis with annular abscess. Recent echocardiography demonstrated a communication between left ventricle and abscess pocket, and the size of pocket increased further at the follow-up echocardiography. The patient underwent patch closure of the defect between left ventricle and pseudoaneurysm located at the aortomitral fibrous continuity, under the cardiopulmonary bypass and cardioplegia. The postoperative course was uneventful and the patient was discharged on the 9th postoperative day.

Intracardiac a Aortic Foreign Body (심장 및 대동맥내 이물 치험 1례)

  • 방정희;편승환
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.932-935
    • /
    • 1997
  • A 50-year-old male patient was admitted due to right ventricular & aortic foreign bodies with ascending aortic pseudoaneurysm. The patient had a history of Kirschner wire fixation of right sternoclavicular joint 3 months ago. Under cardiopulmonary bypass, two K-wires were removed and injured pulmonary valve leaflet and aortic wall were repaired successfully The postoperative course was uneventful and the patient was discharged on the 14th postoperative day.

  • PDF

Repair of Aortic Periprosthetic Leakage with Pseudoaneurysm -A case report- (가성대동맥류를 동반한 인공대동맥판막 주위 누출의 교정)

  • Kim, Hyuck;Lee, Hyung-Chang;Chung, Won-Sang;Kim, Young-Hak;Kang, Jung-Ho
    • Journal of Chest Surgery
    • /
    • v.38 no.9 s.254
    • /
    • pp.637-639
    • /
    • 2005
  • There are several methods of repairing in aortic periprosthetic leakage after aortic valve replacement. We present a case in with the aortic periprosthetic leakage with pseudoaneurysm was repaired with dacron patch.

Aortic Valve Replacement with Pulmonary Autograft in Patient with Congenital Aortic Stenosis : Ross Procedure without Homograft -one case report - (선천성 대동맥판 협착증에서 폐동맥판 자가이식편을 이용한 대동맥판 교체술:동종판막을 쓰지 않는 Ross술식)

  • 이은상;윤태진;서동만
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.303-306
    • /
    • 1999
  • This is a genuine case report of the Ross operation without the use of homografts or heterografts in reconstruction of the right ventricular outflow tract. A 8-year-old boy with congenital aortic stenosis underwent aortic valve replacement with a pulmonary autograft and right ventricular outflow tract reconstruction with a pericardial conduit bearing autologous aortic monocusp. The postoperative echocardiography and cardiac angiography revealed good ventricular function and competent neoaortic valve. He has been followed up for 19 months.

  • PDF

Biocompatibility and Histopathologic Change of the Acellular Xenogenic Pulmonary Valved Conduit Grafted in the Right Ventricular Outflow Tract (우심실 유출로에 이식한 무세포화 이종 폐동맥 판막도관의 생체 적합성 및 조직병리학적 변화양상에 대한 연구)

  • 허재학;김용진;박현정;김원곤
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.482-491
    • /
    • 2004
  • Background: The xenogenic or allogenic valves after in Vitro repopulation with autologous cells or in vivo repo-pulation after acellularization treatment to remove the antigenicity could used as an alternative to synthetic polymer scaffold. In the present study, we evaluated the process of repopulation by recipient cell to the acellu-larized xenograft treated with NaCl-SDS solution and grafted in the right ventricular outflow tract. Material and Method: Porcine pulmonary valved conduit were treated with. NaCl-SDS solution to make the grafts acellularized and implanted in the right ventricular outflow tract of the goats under cardiopulmonary bypass. After evaluating the functions of pulmonary valves by echocardiography, goats were sacrificed at 1 week, 1 month, 3 months, 6 months, and 12 months after implantation, respectively. After retrieving the implanted valved conduits, histopathologic examination with Hematoxylin-Eosin, Masson' trichrome staining and immunohistochemical staining was performed. Result: Among the six goats, which had been implanted with acellularized pulmonary valved conduits, five survived the expected time period. Echocardiographic examinations for pulmonary valves revealed good function except mild regurgitation and stenosis. Microscopic analysis of the leaflets showed progressive cellular in-growth, composed of fibroblasts, myofibroblasts, and endothelial cells, into the acellularized leaflets over time. Severe inflammatory respon-se was detected in early phase, though it gradually decreased afterwards. The extracellular matrices were regenerated by repopulated cells on the recellularized portion of the acellularized leaflet. Conclusion: The acellularized xenogenic pulmonary valved conuits were repopulated with fibroblasts, myofibroblasts, and endothelial cells of the recipient and extracellullar matrices were regenerated by repopulted cells 12 months after the implantation. The functional integrity of pulmonary valves was well preserved. This study showed that the acellularized porcine xenogenic valved conduits could be used as an ideal valve prosthesis with long term durability.

Aortic Root Reconstruction for Aortic Insufficiency Developed after Fontal Operation - 1 case - (Fontan 수술후 발생한 대동맥판막역류에 대한 aortic root의 재 건술 - 1례 보고 -)

  • Kyung, Mon-Chol;Whang, Song-Wok;Lee, Chol;Kim, Yung-Jin
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.137-140
    • /
    • 2002
  • Aortic regurgitation in the pediatrics who had previous cardiac surgery is increased with their improved longterm survival rate and their complexity of heart disease. So the need of aortic valve surgery in pediatrics is also on the increase. A 10-year old boy was admitted for progressive cyanosis and dyspnea on exertion(DOE). The patient had been underwent lateral tunnel Fontan operation before. Echocardiography and cardiac catheterization study revealed hepatic vein drained to pulmonary atrium via intrahepatic collaterals, moderate atrioventricular regurgitation, and severe aortic regurgitation due to aortic root dilation. We report a case who had aortic root reconstruction, valvuloplasty of the atrioventricular valve, and hepatic vein ligation successfully Cyanosis and DOE was dramatically improved after the operation

Coronary Blood Flow Disturbance of a Single Coronary Artery in a Patient Undergoing Aortic Valve Replacement - A case report - (단일관상동맥환자에시 대동맥판막 치환술 시행 중 발생한 관상동맥혈류장애의 치험 - 1예 보고 -)

  • Jung, Hee-Suk;Lee, Jae-Won;Jung, Sung-Ho
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.774-776
    • /
    • 2009
  • A 57-year-old man with dyspnea was transferred to our institution. Echocardiography demonstrated grade III aortic valve regurgitation with a bicuspid aortic valve. The preoperative coronary angiography showed a left single nary artery. Replacement of the aortic valve was performed. Ventricular fibrillation developed during weaning patient of cardiopulmonary bypass after aortotomy repair. An anomalous origin of the coronary arteries is an incidental finding. However, in patients who are undergoing aortic valve replacement, a can significantly complicate the procedure. If this is present, then it is imperative that the clearly identified and the required procedure should be modified to avoid injury to these.

Changes of Mitral Regurgitation after Aortic Valve Replacement, according to the Aortic Valve Pathology (대동맥 판막 치환술 후 대동맥 판막 병변에 따른 승모판막 폐쇄부전의 변화)

  • Kim, Si-Wook;Lee, Young-Tak;Jun, Tae-Gook;Sung, Ki-Ick;Kim, Wook-Sung;Yang, Ji-Hyuk;Choi, Jin-Ho;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.10
    • /
    • pp.667-673
    • /
    • 2007
  • Background: Patients with severe aortic valve disease frequently display mitral valve regurgitation (MR). In such patients, the clinical course of MR after isolated aortic valve replacement (AVR) may be important for determining the treatment strategies. After isolated AVR, the change of the concomitant moderate degree or less of MR according to the type of aortic valve disease is not known well. The aim of this study was to analyze the post-operative changes of MR after performing AVR in those patients with severe AS (Group S) and those with severe AR (Group R). Material and Method: We retrospectively evaluated 43 patients with severe aortic disease and a moderate degree or less of mitral valve regurgitation, and these patients underwent isolated aortic valve replacement from January 1996 to June 2005. The patients were divided into two groups: the aortic valve stenosis group (n = 29) and the aortic valve regurgitation group (n = 14). The patients underwent transthoracic echocardiography preoperatively and at 7 days, $6{\sim}10$ months and more than 18 months (mean follow-up duration: 38 months) postoperatively. Result: The mean age was 60.9 years (Group S: 62 years, Group R: 52.5 years) and 60% (Group S=55%, Group R=71%) of the patients were male. The preoperative MR was mild in 29 (67.5%), mild to moderate in 11 (25.5%), and moderate in 3 (6.9%) patients. In the Group S patients, MR improved in 16 (55%) patients at the immediate postoperative days and in 17 (59%) patients at more than 18 months postoperatively. On the other hand, all the Group R patients exhibited earlier improvement. The decrease of LA size had a similar pattern to the MR change, but there were no significant differences in the change of the ejection fraction of the two groups. Conclusion: In the patients with severe aortic valve disease and concomitant low grade MR, the MR after AVR improved earlier and more effectively in the patients with AR than in those patients with AS.

The Long-term Clinical Result of St. Jude Mechanical Valve Replacement (St. Jude 기계판막 치환술의 장기 임상성적)

  • 배윤숙;정성철;김우식;정승혁;유환국;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.321-328
    • /
    • 2003
  • Background: The St. Jude Medical prosthesis is one of the popularly used artificial prosthesis, therefore the National Medical Center reports the long-term clinical results of patients who underwent prosthetic valve replacement with St. Jude medical valve for 18 years. Material and Method: Between January, 1984 and June, 2002, a series of 163 consecutive patients who had Implanted St. Jude prosthesis at the National Medical Center were reviewed. Mean age was 42.9$\pm$15.1 years and male to female ratio was 69:94. The operative procedure comprised of 87 MVR, 30 AVR, 45 DVR, and 1 TVR. The reoperative procedure comprised of 21 MVR, 2 AVR, and 14 DVR. Follow-up rate was 96.9%, and cumulative follow-up was 823.8 patient-years. Result: Early mortality rate was 7.9% (13 patients), late mortality rate was 8.7% (13 patients) and late mortality due to valve related complication was 47% (7 patients). Actual survival rate at 10 and 18 years were 91.7$\pm$2.1% and 91.0$\pm$1.9%. Linearized Incidence was as follows: thromboembolism, 1.09%/ patient-year; anticoagulant related hemorrhage, 0.36%/patient-year; valve thrombosis, 0.24%/patient-year; paravalvular leakage, 0.12%/patient-year; and prosthetic bacterial endocarditis, 0.12%/patient-year linearized incidence of over all valve related complication was 1.94%/patient-year. Freedom from valve related complication at 10 and 18 years were 89.1$\pm$3.3% and 88.4$\pm$3.9%. Freedom from valve related death at 10 and 18 years were 95.1$\pm$1.2% and 95.1$\pm$1.0%. Valve related complication was related the age of patient, especially anticoagulant related hemorrhage was more common in patients over 60 years of age. Valve related complication, death were higher in DVR than AVR or MVR, and valve related death was higher in reoperation. There was no relationship between valve related complication or death and implant valve of size. Conclusion: The long-term clinical results of patients implanted with St. Jude Mechanical prosthesis was quite satisfactory with a low incidence of valve related complication and mortality.

Acceptability of Low Intensity Anticoagulation Therapy after Mechanical Heart Valve Replacement (기계식 인공 심장판막 치환술 후 낮은 강도 항응혈 관리의 적정성에 관한 연구)

  • Kim, Jong-Woo;Rhie, Sang-Ho;Kim, Young-Chun;Yang, Jun-Ho;Jang, In-Seok;Choi, Jun-Young
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.193-200
    • /
    • 2009
  • Background: The long-term administration of oral anticoagulant to the patients with a mechanical heart valve prosthesis is mandatory. However, the appropriate intensity of oral anticoagulant therapy to prevent thromboembolic or hemorrhagic complications is still controversial. We tried to apply low intensity anticoagulant therapy for which the International Normalized Ratios ranged between 1.5 and 2.5, and we analyzed the anticoagulation-related long term outcomes. Material and Method: From January 1992 to December 2002, 144 patients who underwent a single cardiac valve replacement were included in the study, and their ages ranged from 15 to 72 years (mean age: $47.4{\pm}15.1$): there were 49 aortic valve replacements (AVR) and 95 mitral valve replacements (AVR). The patients were followed up monthly or bi-monthly at the outpatient clinic with clinical examinations and measuring the prothrombin time to adjust the International Normalized Ratios (INRs) within the low-intensity target range between 1.5 and 2.5. Result: The follow-up period was 835.3 patient-years (mean: $5.9{\pm}3.5$) and the INRs of 7,706 measurements were available for evaluation. The mean INRs of the aortic and the mitral valve replacement groups were significantly different (p<0.01). All the patients' INRs were within the target range in 61.9% of the measurements. The mean INRs $(2.16{\pm}0.23)$ of the patients with atrial fibrillation, which was found in 30.3% of the patients, were definitely higher than those $(2.03{\pm}0.27)$ measured in the patients with regular rhythm (p<0.01). Thromboembolic episodes occurred in 9 patients with an incidence of 1.08%/patient-year. Major bleeding occurred in 2 patients (MVR) with an incidence of 0.24%/patient-year. The patients who displayed better compliance showed a lower incidence of complications (p=0.000). Conclusion: The anticoagulation therapy with a low-intensity target range after MVR or AVR seems to be effective and feasible, and increasing the patients’ compliance should be done for achieving more effective anticoagulation therapy.