Browse > Article

Repair of Aortic Periprosthetic Leakage with Pseudoaneurysm -A case report-  

Kim, Hyuck (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Hanyang University)
Lee, Hyung-Chang (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Hanyang University)
Chung, Won-Sang (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Hanyang University)
Kim, Young-Hak (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Hanyang University)
Kang, Jung-Ho (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Hanyang University)
Publication Information
Journal of Chest Surgery / v.38, no.9, 2005 , pp. 637-639 More about this Journal
Abstract
There are several methods of repairing in aortic periprosthetic leakage after aortic valve replacement. We present a case in with the aortic periprosthetic leakage with pseudoaneurysm was repaired with dacron patch.
Keywords
Leakage; Aneurysm; Aortic valve; Surgery;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Williams TE, Fanning WJ, Cattanco SM. Aortic paravalvular leaks; alternative suture placement stragegy for the left coronary cusp. Ann Thorac Surg 1995;59:244-5
2 Michael KB. Acquired aortic valve disease. In: Sabiston PC, Spencer FC. Surgery of the chest. 7th ed. Philladelphia: Elsevier Inc. 2005;1293-6
3 Unsal E, Ilhan P, Mustafa Y, Sanser A. An alternative reapir technique for aortic periprosthetic leakge. Eur J Cardiothorac Surg 1999;15:204-5   DOI   ScienceOn
4 Varstela E, Verkkala K. Turto H. Periprosthetic leakage after aortic valve replacement. Ann Chir Gynaecol 1994;83:210-7