• Title/Summary/Keyword: 심장 정맥

Search Result 505, Processing Time 0.019 seconds

Application of Veno-venoarterial Extracorporeal Membrane Oxygenation in Multitrauma Patient with ARDS - A case report - (다발성 외상으로 유발된 급성호흡부전증후군 환자에서 정맥-정맥동맥 체외막 산화기(ECMO)의 적용 - 1예 보고 -)

  • Lee, Sung Jun;Chee, Hyun Keun;Hwang, Jae Joon;Kim, Jun Seok;Lee, Song Am;Kim, Jin Sik
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.104-107
    • /
    • 2010
  • Acute respiratory distress syndrome (ARDS) is difficult to treat and it is often fatal. If the medical treatment for ARDS is not effective, then extracorporeal membrane oxygenation (ECMO) can be applied to the patient. A 22-year-old female who suffered multiple traumatic injuries due to a car accident presented with acute respiratory distress syndrome. Veinarterial extracorporeal membrane oxygenation (VA ECMO) was started to treat her respiratory failure. With the VA ECMO, the systemic oxygen saturation remained at only 84%, and so the ECMO system was switched to V-VA ECMO via an additional venous outflow through the right jugular vein to increase both the systemic and pulmonary oxygen saturation. After conversion to the V-VA type ECMO, the systemic oxygen saturation increased to 94% and the partial pressure of oxygen ($PaO_2$) increased to 65 mmHg. We report here on a successful case of ECMO conversion from the VA type to the V-VA type in a patient with severely hypoxic respiratory failure.

Endocarditis with Intracardiac Migration of Transvenous Permanent Pacing Lead - 1 Case Report - (영구 경정맥 심박조율도관의 심장내 이동과 동반된 심내막염 - 1례 보고 -)

  • Ku, Gwan-Woo;Kang, Shin-Kwang;Won, Tae-Hee;Kim, Si-Wook;Yu, Jae-Hyun;Na, Myung-Hoon;Lim, Seung-Pyung;Lee, Young
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.831-834
    • /
    • 2002
  • When any part of the pacemaker system is infected, all pacemaker hardware should be removed, because reinfection rates of 51% to 77% have been noted in patients whose infected pacemaker system has been only partially explanted. The removal of infected leads during cardiopulmonary bypass prevents mechanical injury as well as the spread of infection and vegetation. We report one case of endocarditis by staphylococcus aureus with infected transvenous pacing lead which was migrated into the heart from the left subclavian vein. We removed the migrated pacing lead and vegetation under cardiopulmonary bypass.

Modeling and Estimation of Cardiac Conduction System using Hidden Markov Model (HMM을 이용한 심장 전도 시스템의 모델화와 추정)

  • Halm, Zee-Hun;Park, Kwang-Suk
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.222-227
    • /
    • 1997
  • To diagnose cardiac arrhythmia owing to reentry mechanism, cardiac conduction system was modeled by modified Hidden Markov modeled by evaluated. First, simulation of transient conduction states and output waves were made with initially assumed parametric values of cardiac muscle repolariztion time, conduction velocity and its automaticity. The output was a series of onset time and the name of the wave. Parameters determined the rate of beating, lengths of wave intervals, rate of abnormal beats, and the like. Several parameter sets were found to simulate normal sinus rhythm, supraventricular /ventricular tachycardia, atrial /vetricular extrasystole, etc. Then, utilizing the estimation theorems of Hidden Markov Model, the best conduction path was estimated given the previous output. With this modified estimation method, close matching between the simulated conduction path and the estimated one was confirmed.

  • PDF

Extracorporeal Membrane Oxygenation in the Patient with Cardiopulmonary Resuscitation Failure after Open Heart Surgery. - A case report - (개심술 후 심폐소생술 실패환아에서의 체외막산소화 치험 1례)

  • 전희재;성시찬;우종수;이혜경
    • Journal of Chest Surgery
    • /
    • v.32 no.1
    • /
    • pp.53-57
    • /
    • 1999
  • We describe a case of successful extracorporeal membrane oxygenation(ECMO) in a small infant with cardiopulmonary resuscitation(CPR) failure after an open heart surgery. A 35-day-old male infant weighing 4.4 kg who had congestive heart failure and pulmonary hypertension underwent patch closure of ventricular septal defect without any intraoperative event. Postoperative course was unremarkable in the intensive care uint for about 5 hours before the junctional ectopic tachycardia developed. Sudden cardiac decompensation with bradycardia occurred about 50 minutes after the development of junctional ectopic tachycardia. He was put on ECMO by arterial cannulation at the ascending aorta and by venous cannulation at the right atrial appendage after 4 hours' CPR. The hemodynamics were stable with enough urine output during ECMO. He was weaned from ECMO 38.5 hours after initiation. Delayed sternal closure was attempted. He was extubated on postoperative day 7 and discharged home on postoperative day 21 without any neurologic sequelae.

  • PDF

Cardiac Lymphoma in a Shih Tzu Dog (씨츄 개에서 발생한 심장 림프종)

  • Kim, Tae-Young;Joo, Jeong-Hoon;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.30 no.3
    • /
    • pp.196-200
    • /
    • 2013
  • A 7 years-old intact female dog (4.8 kg) was referred with primary complaints of enlarged surface lymph nodes, cardiac murmur, coughing and exercise intolerance. Diagnostic imaging studies found cardiomegaly with distended caudal vena cava, marked left ventricular and interventrciular septal thickening and flattening, severe aortic and pulmonic stenosis (~5 m/s), and mitral and tricuspid regurgitation (~4 m/s). Cytology for the samples obtained from submandibular lymph node and left ventricle revealed high grade malignant lymphoma. The case was diagnosed as cardiac lymphoma. The dog was treated with prednisolone (2 mg/kg, PO, q24h), lomustine (80 $mg/m^2$ PO, q3wk), diltiazem (1 mg/kg, PO, q12h) and enalalpril (0.5 mg/kg, PO, q12h). The clinical signs were improved after therapy. The dog is still on the chemotherapy and regularly checked up.

Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography (게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun;Kim, Jae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.150-154
    • /
    • 2010
  • Purpose: Ejection fraction (EF) is one of the most important factors that evaluate heart function. Recently, according to echocardiography and myocardial perfusion SPECT, the number of gated blood pool scan (planar GBP) is declining. Measurement of left ventricular ejection fraction using gated blood pool SPECT (GBPS) is known as relatively correspond with echocardiography. We compared EF derived from plnar GBP, GBPS and echocadiography using modified simpson method to determine the accuracy. Materials and Methods: From January 2007 to June 2010, planar GBP and GBPS were performed on 34 patients who admitted to Pusan National University Hospital (men 23, women 11, mean age $52.6{\pm}27.2$). Each patient was injected with $^{99m}{TcO_4}^-$ of 20 mCi after pyrophosphate injection and then scanned using both planar GBP and GBPS techniques. For image analysis, we use ADAC Laboratories, Ver. 4.20 software. The result analyzed was processed by SPSS 17.0 Win statistic program and statistical method applied in data analysis is one-way anova, Tukey's post hoc test, pearson correlation test. Results: One-way anova test show no significant difference (planar GBP $56.3{\pm}13.9%$; GBPS $60.4{\pm}16.0%$; echocardiography $59.1{\pm}14.4%$, p=0.486, p>0.05). Tukey's post hoc test show no significant difference (planar GBP-echocardiography p=0.697; GBPS-echocardiography p=0.928; planar GBP-GBPS p=0.469, p>0.05). Values for EF obtained with planar GBP and GBPS correlated well with those obtained with echocardiography (planar-echocardiography r=0.697; GBPS-echocardiography r=0.928; planar GBP-GBPS r=0.469). Conclusion: The problems of accuracy and reproducibility for planar GBP still remain. But planar GBP is a safe and non-invasive method. In addition, planar GBP is useful to evaluate patient with low resolution echocardiography images. GBPS is not appicated clinically. but GBPS can be obtain various left ventricular functional parameters. planar GBP, GBPS and echocardiography show a good correlation between each other. Therefore, planar GBP and GBPS are useful for evaluating left ventricular ejection fraction.

  • PDF

Coronary Fistulas -20 years experience - (관상동맥루)

  • Lee Jeong Ryul;Jung Yo Chun;Choi Chang Hyu;Kim Woong Han;Kim Yong Jin;Bae Eun Jung;Noh Chung Il
    • Journal of Chest Surgery
    • /
    • v.38 no.9 s.254
    • /
    • pp.609-615
    • /
    • 2005
  • Background: Some controversy still exists concerning the operative indications of coronary fistulas. Nevertheless, a short-term and long-term outcomes are excellent with surgical interventions. In this study, we assessed our surgical results on this disease entity during the last 20 years. Anatomic diversity was described as well. Material and Method: From April 1986 to March 2005, 20 patients with coronary fistulas underwent surgical correction in Seoul National University Children's Hospital. Their medical records were reviewed retrospectively. Result: Twelve patients ($60\%$) were asymptomatic prior to surgery. All had electrocardiogram and echocardiogram and all but 3 had coro-nary angiogram preoperatively. Anatomically, none of them had two or more coronary fistulas. The sites of origin were left coronary system in 11 patients and right in 9. The draining sites were right ventricle in 11, right atrium in 3, left ventricle in 3, main pulmonary artery in 2, and superior vena cavae in 1. All of the involved, the coro-nary arteries were dilated or aneurismal. In 1 case, there was atherosclerotic change but no ischemic evidence in preoperative electrocardiogram. Operative techniques included external obliteration (13), internal obliteration (5), and both (2). External obliteration was done by ligation of the fistulous tract only in T patients, by fstula ligation plus plication in 3 and by plication or patch closure via fistulotomy in 3. There was no operative mortality. All of postoperative morbidities including transient sinus arrhythmia (2), complete atrioventricular block (1), decreased left ventricular function (2), ventricular tachycardia (1), pericarditis (1), and seizure (1) improved on discharge. The mean follow-up was 55.1$\pm$50.2 months (4.0 months${\~}$18.0 years) and there were no recurrences of fistula. There was 1 second operation for aortic root aneurysm, which developed after external patch closure of right coronary fistula. Conclusion: We demonstrated here that coronary fistulas can be cured with excellent clinical outcome and low operative risk under precise diagnosis. Understanding the anatomic diversity will help to construct surgical plans.

Myocardial Perfusion after Transmyocardial Mechanical Revascularization in Rat Heart Transplant Model, Acute Model (백서 동종이식 심장모델에서 기계적 경심근 혈관재형성의 심근 혈류 개선 효과 : 급성기 모델)

  • Shinn Sung Ho;Chung Won Sand;Kang Jung Ho;Jeon Yang-Bin
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.468-475
    • /
    • 2005
  • Transmyocardial revascularization (TMR) in end stage ischemic heart disease results in variable clinical responses. We investigated the acute effect of early reperfusion and the angiogenesis after formation of the transmyocardial channel in a transplanted rat heart model with acute myocardial infarction. Material and Method: In the 30 transplanted hearts we induced acute myocardial infarction by ligating the proximal left coronary artery and inserted a porous 22G intravenous cannula into the left ventricle. After ten minutes of reperfusion, we removed the cannula. At every stage, we recorded the heart rate, QRS size, and left coronary arterial blood flow using the electrocardiogram and Doppler. One week later the rats were sacrificed and evaluated for the patency of intramyocardial channels and the angiogenesis. Result: The heart rates after ligation and after cannula insertion were $239.1\pm61.7,\;235.8\pm58.0bpm$ respectively, and they were statistically significantly slower than that of before ligation, $277.6\pm40.3bpm\;(p=0.017,\;p=0.007\;respectively)$. QRS sizes before ligation, after ligation, and after cannula insertion were $3.6\pm3.3mm,\;2.8\pm3.3 mm,\;and\;2.4\pm2.2mm,$respectively, and there was no significant difference in the three groups. Doppler findings after ligation showed that average peak and mean values of coronary perfusion were significantly decreased from $2.11\pm0.17kHz,\;1.25\pm0.22kHz\;to\;0.83\pm0.15kHz,\;0.38\pm0.11kHz$(p<0.05 respectively). After insertion of the porous cannula, the average peak and mean values of coronary perfusion were $0.61\pm0.05kHz\;and\;0.33\pm0.05 kHz$ respectively, but there was no statistically significant change compared to values after ligation. In all cases except one, pathologic findings showed no patent channels in the acute stage, however, one case showed the angiogenesis. Conclusion: We confirmed that TMR in a rat heart transplant model did not show blood flow through the channel in the acute stage. However, reperfusion effect in some cases had a potential for angiogenesis.

Saphenous Vein Graft as a Composite Graft in Patients Who Are Undergoing Off-pump Coronary Artery Bypass: The Early Results (복재정맥 복합도관을 이용하여 시행한 심폐바이패스를 사용하지 않는 관상동맥우회술의 조기 결과)

  • Hwang, Ho-Young;Kim, Jun-Sung;Choi, Eun-Seok;Lee, Jae-Hang;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.324-330
    • /
    • 2009
  • Background: The long term patency of the free saphenous vein graft, which is the most commonly used conduit, anastomosed to the ascending aorta has been reported to be lower than that of arterial grafts. We evaluated early clinical outcome and the angiographic patency of the saphenous vein composite graft based on the left internal thoracic artery, and compared these results with those of using arterial composite grafts. Material and Method: From September 2006 to October 2008, 419 patients underwent off-pump coronary revascularization. Among those, 295 patients (70.4%) were revascularized using composite grafts (group I: saphenous vein composite graft, n=71, group II: arterial composite graft, n=224). The clinical results were compared between the 2 groups. Early postoperative coronary angiograms were performed in all the patients. ($1.6{\pm}1.6$ days) Result: The number of the distal anastomosis per patient was $3.5{\pm}1.0$ and $3.1{\pm}0.8$ in group I and II, respectively (p=.002). The operative mortality (n=2, 0.7%) and postoperative complications such as atrial fibrillation (n=73, 24.7%), perioperative myocardial infarct (n=6, 2.0%), acute renal failure (n=6, 2.0%), reoperation for bleeding (n=5, 1.7%), cerebrovascular accident (n=3, 1.0%), and mediastinitis (n=1, 0.3%) were not related with the use of saphenous vein graft. Early coronary angiograms revealed a 96.9% (126/130) for the saphenous vein grafts and a 98.8% (479/485) for the composite graft in group II (p=.231). Conclusion: Our data suggested that a saphenous vein graft might be used as analtemative conduit to the arterial graft for constructing a composite graft, as based on our early clinical and angiographic results. Further study is required to establish the long-term efficacy of using a saphenous vein as a composite graft.

The Clinical Effects of Normocapnia and Hypercapnia on Cerebral Oxygen Metabolism in Cardiopulmonary Bypass (체외순환 시 뇌대사에 대한 정상 탄산분압과 고 탄산분압의 임상적 영향에 관한 비교연구)

  • 김성룡;최석철;최국렬;박상섭;최강주;윤영철;전희재;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.35 no.10
    • /
    • pp.712-723
    • /
    • 2002
  • Substantial alterations in cerebral blood flow(CBF) are known to occur during cardiopulmonary bypass(CPB). Many investigators have speculated that these changes may be responsible for both minor and major cerebral damages after CPB. More recently, these changes in CBF have been observed to be intimately related to the arterial carbon dioxide tension(Pa$CO_2$) maintained during CPB. The present study was prospectively designed to investigate the clinical effects of normocapnic and hypercapnic CPB on the cerebral oxygen metabolism in cardiac surgery Material and Method: Thirty-six adult patients scheduled for elective cardiac surgery were randomized to either normocapnic group (Pa$CO_2$35~40 mmHg, n=18) or hypercapnic group(Pa$CO_2$, 45~55 mmHg, n=18) with moderately hypothermic nonpulsatile CPB(nasopharyngeal temperature of 29~3$0^{\circ}C$). In each patient, middle cerebral artery blood flow velocity( $V_{MCA}$), cerebral arteriovenous oxygen content difference (C(a-v) $O_2$), cerebral oxygen extraction(COE), cerebral metabolic rate for oxygen(CMR $O_2$), cerebral oxygen transport( $T_{E}$ $O_2$), $T_{E}$ $O_2$/CMR $O_2$ ratio, cerebral desaturation(internal jugular bulb blood oxygen saturation $\leq$ 50%), and arterial and jugular bulb blood gas were evaluated throughout the operation. Postoperative neuropsychologic complications were assessed in all patients. All variables were compared between the two groups. Result: VMCA(169.13 $\pm$ 8.32 vs 153.11 $\pm$8.98%), TE $O_2$(1,911.17$\pm$250.14 vs 1,757.40$\pm$249.56), $T_{E}$ $O_2$,/CMR $O_2$ ratio(287.38$\pm$28.051 vs 246.77$\pm$25.84), $O_2$ tension in internal jugular bulb (41.66$\pm$9.19 vs 31.50$\pm$6.09 mmHg), and $O_2$saturation in internal jugular bulb(68.97$\pm$10.96 vs 58.12$\pm$12.11%) during CPB were significantly lower in normocapnic group(p=0.03), whereas hypercapnic group had lower C(a-v) $O_2$(3.9$\pm$0.3 vs 4.9$\pm$0.3 mL/dL), COE(0.3$\pm$0.03 vs 0.4$\pm$0.03), CMR $O_2$(5.8 $\pm$0.5 vs 6.8$\pm$0.6), and arterial blood pH(7.36$\pm$0.09 vs 7.46$\pm$0.07, p=0.04) during CPB. Hypercapnic group had lower incidence of cerebral desaturation than normocapnic group(3 vs 9 patients, p=0.03). Duration of the neuropsychologic complication(delirium) were shorter in hypercapnic group than in normocapnic group(36 vs 60 hrs, p=0.009). Conclusion: These findings suggest that hypercapnic CPB may have salutary effects on the cerebral oxygen metabolism and postoperative neurologic outcomes in cardiac surgery.surgery.