Application of Cardiac Electromechanical FE Model for Predicting Pumping Efficacy of LVAD According to Heart Failure Severity (심부전 정도에 따른 좌심실보조장치의 박동효율예측을 위한 심장의 전기역학적 유한요소 모델의 응용)

  • Jung, Dae Hyun;Lim, Ki Moo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.8
    • /
    • pp.715-720
    • /
    • 2014
  • In order to maximize the effect of left ventricular assist device (LVAD) on ventricular unloading, the therapy should be begun at appropriate level of heart failure severity. We predicted pumping efficacy of LVAD according to the severity of heart failure theoretically. We used 3 dimensional finite element model of ventricle coupled with 6 Wind-kessel compartmental model of vascular system. Using the computational model, we predicted cardiac responses such as contractile ATP consumption of ventricle, left ventricular pressure, cardiac output, ejection fraction, and stroke work according to the severity of ventricular systolic dysfunction under the treatments of continuous LVAD. Contractile ATP consumption, which indicates the ventricular energetic loading condition decreased maximally at the $5^{th}$ level heart-failure under LVAD therapy. We conclude that optimal timing for LVAD treatment is $5^{th}$ level heart-failure when considering LVAD treatment as "bridge to recovery".

The Application of a Bi-ventricular Assist Device for a Low Weight (2.4 kg) Neonate with Coarctation of the Aorta and Critical Aortic Stenosis (대동맥 축착증 및 심한 대동맥 협착을 가진 저체중 신생아(2.4 kg)의 수술 전후 발생한 심실 기능 부전의 치료에 대한 양심실 보조 장치 적용 치험 예)

  • Kwak, Jae-Gun;Park, Chun-Soo;Lee, Chang-Ha;Lee, Cheul
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.304-307
    • /
    • 2010
  • A 5-day-old neonate (body weight=2.4 kg) with coarctation of the aorta and critical aortic stenosis underwent an interventional balloon valvuloplasty for aortic stenosis. During the intervention, cardiac arrest occurred due to injury of the right carotid artery by the guide wire. An extracorporeal membrane oxygenator (ECMO) was applied. After 1 day's support, total surgical correction was achieved; however, in the immediate postoperative period, cardiac function was severely depressed. We applied a bi-ventricular assist device (bi-VAD) instead of an ECMO and we were able to wean the patient off the bi-VAD device after 3 days' support. The patient was discharged without severe complications.

Animal Experiment and Blood Biocompatibility Study of Polymer Valve (고분자판막의 동물실험 및 생체내 혈액적합성 연구)

  • 김상현;홍유선
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.357-362
    • /
    • 1997
  • In vivo testings of the monoleaflet polymer valve were performed in seven dogs to prove its blood biocompatibility. The monoleaflet polymer valve used in this study was developed for short-term usage n the ventricular assist device. The frame and leaflet of the polymer valve were made of polyurethane. The inter-aortic valved conduit were implanted in four dogs and the ventriculo-atrial valved conduit was implanted in one dog. The ventricular assist devices with polymer valve were implanted in two dogs. The longest survival was 20 days. Main causes of death were bleeding and infection. To examine the blood compatibility, each blood sample was collected and RBC, WBC, hematocrit, hemoglobin, platelet and lactic acid dehydrogenase were analyzed. These studies thus far demonstrated that, with further development, a reliable and inexpensive polymer valve will be used in the ventricular assist device as short term usage.

  • PDF

Skeletal Muscle Ventricle Mechanics (골격근 심실의 역학)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.428-432
    • /
    • 1999
  • Background: It has been shown that low-grade electrical stimulus can transform fatigue resistant muscles which then can be used to protect the heart. The bulky and cumbersome power sources of the artificial heart or implantable ventricular assist devices are still in need of solution; however, on the other hand, the implantable ventricular assist devices using the resistant muscles as the power source have the advantages of using its own muscle contractions. The purpose of this study was to determine the possibility of a clinical application of the skeletal muscle ventricle. Material and Method: Latissimus dorsi muscles (LDM) of 8 canines were used for skeletal muscle ventricle. A latex chamber was wrapped one and a half times with LDM. The chamber was attached to a pressure transducer via Tygon tube. An electrode stimulator was placed around the thoracodorsal nerve and LDM was stimulated in cyclic bursts of 0.31 sec on time and 6.0 sec off time using 3.0 volt Itrel stimulator. The preload volume was added to the system in 25cc increments. Ejection volumes, pressures, and peak power outputs were measured. Result: Ejection volume was 76.3cc with 0cc of preload. Ejection volumes were less than 70ml with increments of preload over 75cc Pressures were more than 107 mmHg when the preloads were less than 75cc and less than 100 mmHg when the preloads were more than 100cc. Peak power output of 16.6 W/kg was observed at 50cc preload. Conclusion: Depending on the changes of preload, the volumes ejected from skeletal muscle ventricle and pressures from the skeletal muscle contraction surpassed those of the normal heart. These data suggest that there are clinical applications for skeletal muscle ventricular assist system.

  • PDF

Reoperation of Postinfarction VSD (심근경색증의 합병증으로 발생한 심실중격 파열의 재수술)

  • 안재호
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.528-532
    • /
    • 1997
  • After early surgical repair of ventricular septal rupture complicated by myocardial infarction, newly developed ventricular septal defects were discovered on the 7th and the 40th postoperative day in 2 cases. We reoperated these patients for closure of newly developed ventricular septal defects with Dacron patch successfully on the 77th and the loth day after discovery of those defects. From these results we conclude that early surgical rep ir for ruptured ventricular septum following myocardial infarction is an appropriate approach with low risk and that remnant or recurred ventricular septal defect can be corrected rather safely with proper myocardial preservation and unrestricted application of intraaortic balloon pump or other ventricular assist device.

  • PDF

Treatment of Pulmonary Hypertensive Crisis Using ECMO - A Case Report - (성인의 선천성 심질환 수술 후 발생한 폐동맥 고혈압 위기증에서 체외막 산소화 장치를 이용한 치험 - 1례 보고 -)

  • 최재성;김기봉
    • Journal of Chest Surgery
    • /
    • v.35 no.9
    • /
    • pp.664-667
    • /
    • 2002
  • Extracorporeal membrane oxygenation(ECMO) provides stable oxygenation to prevent elevation of pulmonary vascular resistance and bypasses a significant part of cardiac output to the pulmonary vascular bed to reduce pulmonary perfusion pressure. In addition, ECMO prevents right heart failure and low cardiac output by means of ventricular assist and reduction in volume load to right ventricle. As a result, ECMO can be used for the treatment of pulmonary hypertensive crisis after surgery for congenital heart disease, especially when it is refractory to conventional measures. We report a case of postoperative pulmonary hypertensive crisis, developed in a 37-year-old male with patent ductus arteriosus with secondary pulmonary hypertension, which was successfully managed including ECMO.

Successful Rescue of Refractory Ventricular Tachycardia after One and a Half Repair in Ebstein's Anomaly by Extracorporeal Membrane Oxygenation (부분 양심실 교정을 받은 엡스타인 기형에서 발생한 심실성 빈맥에 대해 체외막 산소화 장치를 이용한 성공적인 구출)

  • Seo, Hong-Joo;Whang, Sung-Wook;Lee, Cheul;Lim, Hong-Gook;Yu, Jai-Kun;Lee, Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.220-224
    • /
    • 2007
  • Extracorporeal membrane oxygenation (ECMO) provides mechanical cardiopulmonary support and has been used for children with severe respiratory failure, intractable heart failure, sepsis, pulmonary hypertension, and as a bridge to heart transplantation. There have been few reports of the use of ECMO to provide cardiac support in children with low cardiac output as a result of arrhythmias. We report the case of a 15-year-old female with circulatory collapse due to refractory ventricular arrhythmia after one and a half repair in Ebstein's anomaly, who was successfully resuscitated using ECMO.