• Title/Summary/Keyword: 심미 치과학

Search Result 859, Processing Time 0.026 seconds

Fabrication of complete dentures using treatment dentures for a patient with erratic mandibular movements: A case report (불규칙한 하악 운동을 하는 환자의 treatment denture를 이용한 총의치 수복 증례)

  • Kim, Jun-Yub;Park, Chan;Vang, Mong-Sook;Yang, Hong-So;Lim, Hyun-Pil;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.359-365
    • /
    • 2015
  • Long-term use of ill-fitting dentures may cause irregular movements of the mandible. In such cases, satisfactory outcomes both in terms of function and esthetics could be achieved by accurate registration of mandibular movement and centric relation when fabricating new dentures. In this case, treatment dentures with flat occlusal tables were used to register centric relation and mandibular movements of a patient with erratic mandibular movements.

DETERMINATION OF ESTHETIC REFERENCE PLANE FOR SEMI-ADJUSTABLE ARTICULATORS (반조절성 교합기의 심미적 기준 평면에 관한 연구)

  • Hwang, Hie-Seong;Jeon, Young-Chan;Jung, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.448-456
    • /
    • 1996
  • The purpose of this study is to evaluate suitable anterior reference point similar to esthetic reference plane of the patient while transferring the suitable facebow. So those who live in Pusan with the normal occlusal relationship were chosen as subjects. The esthetic reference planes determined by the participants themselves and the superior reference line (anterior reference point) in Hanau & Denar articulator were compared with F-H plane in the standard lateral cephalogram. The results were as follows. 1. The angle between the esthetic reference plane and F-H plane was $2.81{\pm}5.7^{\circ}$. 2. The reference line, 43mm from Beyron point to the edge of the upper incisor, was the reference plane that had the closest paralleled relationship with the esthetic reference plane. 3. Transferring with ear piece type face-bow, the anterior reference point that showed the esthetic reference plane was 17mm below orbitale or 43mm above, the edge of the upper incisor.

  • PDF

Relationship between the Malocclusion and Caries Prevalence of Adolescents in Iksan (익산시 청소년의 부정교합과 치아우식 유병률 사이의 연관성)

  • Shin, Gayoung;Ra, Jiyoung;An, Soyoun;Song, Jihyun;Lee, Kwanghee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.3
    • /
    • pp.207-217
    • /
    • 2014
  • The purpose of the present study was to evaluate the relationship between the malocclusion and dental caries in adolescents with permanent dentition. The subjects of the study were 385 adolescents aged 12 to 15 years. Dental Aesthetic Index (DAI) and DMFT index were recorded as clinical indicators of malocclusion and dental caries. The mean Dental Aesthetic Index (DAI) score of the subjects was 12.42 and the mean DMFT index of the subjects was 2.89. Four students (1.04%) were included in the group of orthodontic treatment mandatory, which signifies the handicapping malocclusion. Moreover, the result of gender-specific analysis of the DAI components observed that the prevalence of midline diastema and mandibular overjet were significantly higher among boys (p < 0.05). In 7 components (missing teeth, incisal segment crowding, maxillary anterior irregularity, mandibular anterior irregularity, mandibular overjet, anterior openbite, antero-posterior molar relationship) among the 10 DAI components, abnormal groups showed significantly higher DMFT index than normal groups (p < 0.05). The subjects in the group of definite to handicapping malocclusion (DAI ${\geq}$ 26) showed significantly higher DMFT index than the subjects in the group of minor or no malocclusion (p < 0.01). In addition, the DAI score had significant positive linear correlation with the DMFT index (r = 0.584, p < 0.01). Consequently, the current findings suggested a positive relationship between the malocclusion and caries prevalence. And several specific types of malocclusion were supposed to be significantly correlated with dental caries.

Osseointegration of Ceramics & Zirconia : A Review of Literature (세라믹과 지르코니아의 골유착에 관한 고찰)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.319-326
    • /
    • 2012
  • For many years, ceramics have been used in fixed prosthodontics for achieving optimal esthetics. but, they have another use as well. Many studies today show ceramics can be used for biomaterials. In the beginning researchers made a start in the study of aluminium oxide and sapphire for biomaterial. The appearance of Zirconia began a new phase of research. Zirconia was introduced into implantology as an alternative to titanium, because of its white color, good mechanical properties and superior biocompatibility. But it is not easy to surface treatment in comparison with titanium. To overcome the limitation, interconnected porous bodies of zirconia were fabricated by sintering technique. And the technique of coating was developed. Therefore, some zirconia implants are currently available. It is thought that Research of biomaterials as a variety of puposes for the use of zirconia is looking very promising. The purpose of this paper reviews are to evaluation of zirconia as biomaterials.

Reinforcement of provisional restoration with cast metal framework: A case report (주조 금속 구조물을 이용하여 강화한 임시보철물 수복 증례)

  • Kim, Hyun-Young;Moon, Yoon-Hee;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.46-52
    • /
    • 2017
  • Provisional restoration plays an important role in the process of restoration with fixed partial denture by providing protection and restoring function and esthetics of abutment tooth. This is especially true in patients requiring use of provisional prosthesis for a long term. However, such situations may lead to higher possibility of provisional prosthesis fracture, and if expected so, reinforcement of provisional prosthesis should be considered. In this article, a patient requiring prosthetic treatment with increase of vertical dimension of occlusion was introduced. Due to increased vertical dimension of occlusion, the provisional restoration was expected to withstand relatively larger amount of load during a relatively long observation period. In order to minimize possible occurrence of fracture, reinforcement of the provisional restoration was sought by insertion of cast-metal framework and by using bis-acryl resin. The reinforced provisional restoration showed satisfactory results during the observation period of 4 months.

DMLS (Direct Metal Laser Sintering) denture repair technique for a removable partial denture: A case report (DMLS (Direct Metal Laser Sintering) 기술을 이용한 가철성 국소의치 수리 증례)

  • Jang, Eun-Sun;Jang, Geun-Won;Byun, Jae-Joon;Kong, Dae-Ryong;Song, Joo-Hun;Lee, Gyeong-Je
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.251-256
    • /
    • 2020
  • In recent years, digital technology has been developed in dentistry, which denture frameworks can be manufactured using DMLS (Direct Metal Laser Sintering) technique. A traditional impression method can be replaced by oral scanning and wax pattern production process can be achieved by the use of CAD/CAM techniques. The designed STL files can be sent to DMLS devices to fabricate final components of removable partial dentures (RPD). The advantages of digital dentistry are concision and precision. In this case study, a fracture of occlusal rests providing support and indirect retention was repaired by DMLS and laser welding techniques. It shows satisfactory results in adaptation accuracy and functional properties of the repaired denture.

Restoration of patient accelerating anterior teeth wear by loss of posterior support: Case report (구치부 지지 소실에 의한 전치부 마모 가속화 환자의 수복: 증례보고)

  • Choi, Hyejin;Lee, Jaehoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.382-388
    • /
    • 2019
  • Increased anterior teeth mastication following posterior teeth loss leads to greater anterior occlusal force. It may cause greater attrition of anterior teeth, traumatic force occlusion (TFO), also often followed by antagonist extrusion and occlusal disharmony. This clinical report describes the treatment for a 67-year-old female patient diagnosed with loss of both maxillary and left mandibular posterior teeth, severe attrition of maxillary and mandibular anterior teeth and extrusion of multiple teeth. A diagnostic cast was mounted on articular in centric relation (CR) position to evaluate vertical dimension (VD) and interspace. To provide adequate space for the prosthetic reconstructions, VD was increased by 3 mm on the anterior pin. And then diagnostic wax-up was completed upon that VD. Wax-up was converted to provisional restorations and verified in the patient's mouth and the final restorations were delivered. Clinical follow up examination held 3 months after temporary restoration owing to changes in vertical dimension revealed proper function in mastication without evidence of temporo-mandibular joint (TMJ) disorders. This clinical report presents successfully restoring severe attrition case with increasing vertical dimension resulting in satisfaction in esthetics and function.

Flapless implant placement with digital 3D imaging and planning system in fully edentulous patient: A case report and 5-year follow-up (완전무치악 환자에서 디지털 가이드 수술 방식을 이용한 무피판절개 임플란트 식립증례: 증례보고 및 5년 추적관찰)

  • Shin, Mi-sun;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.312-320
    • /
    • 2019
  • One of the fastest growing segments of implant dentistry is the utilization of computed tomography (CT) scan data and treatment planning software in conjunction with guided surgery for implant reconstruction cases. Computer assisted planning systems and associated surgical templates have established a predictable, esthetic, functional technique for placing and restoring implants. Especially, a philosophy of restoratively driven implant placement has been generally adopted. Recently, a variety of commercial dental fields have released their scanning and fabricating protocols and methods for restorations. This process is still being investigated and developed for the most precise and predictable outcome. This case report describes a female patient who wanted dental implants in fully edentulous areas. Restoratively driven implant placements were performed with surgical guide and the patient was fully satisfied with the clinical results, and at 5-year post restorative follow-up assessment, both implant and prosthesis were proved clinical success.

Implant-supported fixed prostheses with high-performance polymer (PEKK) abutments in partial edentulous patients: A case report (부분 무치악 환자에서 고기능성 폴리머(PEKK) 지대주를 이용한 임플란트 고정성 보철물 수복 증례)

  • Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.71-78
    • /
    • 2021
  • Implant treatment, which was first attempted in fully edentulous patients, is now widely used in partially edentulous, and a single tooth missing patients. Moreover, implant treatment has become an essential treatment modality in modern dentistry. The material of fabricating implant prostheses has also become more diverse than before, one of which is the use of high-performance polymers. The frequency of using high-performance polymers, which have been used in the medical field, is also increased in the dental field compared to the past. In the first case, a PEKK abutment and a PFG crown (cement-screw-retaining type) were fabricated in the lower left second premolar, and in the second case, a PEKK abutment and a monolithic zirconia crown (cement-screw-retaining type) were fabricated in the missing upper left first molar, and in the third case two PEKK abutments and a splinted PFM crowns (cement-screw-retaining type) were fabricated and connected to the upper right first and second molar implants. Through these procedures the patients obtained esthetically and functionally satisfactory results after 4 years of follow-up.

Digital interim immediate denture fabrication and implant-supported removable partial denture fabrication after multiple teeth extraction in patient with chronic periodontitis: a case report (만성 치주염 환자에서 다수치 발거 후 디지털 임시 즉시 의치 제작 및 임플란트 지지 가철성 국소의치 수복 증례)

  • Min-Jae Park;Ji-Won Bang;Joo-Hyuk Bang;Seon-Young Lim;Yong-Sang Lee;Keun-Woo Lee;Sung-Yong Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.104-112
    • /
    • 2024
  • When teeth are extracted, patient face social, psychological and aesthetic problems which can be minimized by fabricating a interim immediate denture. Interim immediate denture manufactured using digital technology can be completed with reduced number of patients' visits and simple laboratory process. Implant-supported removable partial denture (ISRPD) has been suggested as alternative treatment option when fixed implant prosthesis is not feasible. In this case, interim immediate dentures were fabricated using digital technology for patient after teeth extraction and treatment using ISRPD by installing implants and surveyed crowns is found to be successful with better support, stability and maintenance of removable partial dentures.