DMLS (Direct Metal Laser Sintering) denture repair technique for a removable partial denture: A case report
![]() |
Jang, Eun-Sun
(Department of Prosthodontics, School of Dentistry, Chosun University)
Jang, Geun-Won (Department of Prosthodontics, School of Dentistry, Chosun University) Byun, Jae-Joon (Department of Prosthodontics, School of Dentistry, Chosun University) Kong, Dae-Ryong (Department of Prosthodontics, School of Dentistry, Chosun University) Song, Joo-Hun (Department of Prosthodontics, School of Dentistry, Chosun University) Lee, Gyeong-Je (Department of Prosthodontics, School of Dentistry, Chosun University) |
1 | Smith RA. Clasp repair for removable partial dentures. J Prosthet Dent 1973;29:231-4. DOI |
2 | Park SA, Koak JY, Heo SJ, Kim SK, Park JM. RPD framework fabrication using computer-aided design (CAD) and rapid prototyping. J Korean Acad Prosthodont 2017;55:94-9. DOI |
3 | Livaditis GJ. Repair with a surveyed cast clasp while patient retains the partial denture. J Prosthet Dent 1997;77:624-9. DOI |
4 | Venkatesh KV, Nandini VV. Direct metal laser sintering: A digitised metal casting technology. J Indian Prosthodont Soc 2013;13:389-92. DOI |
5 | Nishiyama H, Taniguchi A, Tanaka S, Baba K. Novel fully digital workflow for removable partial denture fabrication. J Prosthodont Res 2020;64:98-103. DOI |
6 | Duda T, Raghavan LV. 3D metal printing technology. IFACPapersOnLine 2016;49:103-10. |
7 | Eggbeer D, Bibb R, Williams R. The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks. Proceedings of the Institution of Mechanical Engineers, Part H: J Eng Med 2005;219:195-202. DOI |
8 | Williams RJ, Bibb R, Eggbeer D, Collis J. Use of CAD/CAM technology to fabricate a removable partial denture framework. J Prosthet Dent 2006;96:96-9. DOI |
9 | Schweiger J, Guth JF, Erdelt KJ, Edelhoff D, Schubert O. Internal porosities, retentive force, and survival of cobaltchromium alloy clasps fabricated by selective laser-sintering. J Prosthodont Res 2020;64:210-6. DOI |
10 | Tuna SH, Ozcicek Pekmez N, Kurkcuoglu I. Corrosion resistance assessment of Co-Cr alloy frameworks fabricated by CAD/CAM milling, laser sintering, and casting methods. J Prosthet Dent 2015;114:725-34. DOI |
11 | Lapcevic AR, Jevremovic DP, Puskar TM, Williams RJ, Eggbeer D. Comparative analysis of structure and hardness of cast and direct metal laser sintering produced Co-Cr alloys used for dental devices. Rapid Prototyp J 2016;22:144-51. DOI |
12 | Suzuki Y, Ohkubo C, Abe M, Hosoi T. Titanium removable partial denture clasp repair using laser welding: a clinical report. J Prosthet Dent 2004;91:418-20. DOI |
13 | Zhou Y, Li N, Yan J, Zeng Q. Comparative analysis of the microstructures and mechanical properties of Co-Cr dental alloys fabricated by different methods. J Prosthet Dent 2018;120:617-23. DOI |
![]() |