• Title/Summary/Keyword: 심근관류

Search Result 258, Processing Time 0.025 seconds

Correlation between Semiquantitative Myocardial Perfusion Score and Absolute Myocardial Blood Flow in $^{13}N-Ammonia$ PET ($^{13}N$-암모니아 PET에서 반정량적 심근관류 점수와 절대적 심근혈류량의 상관관계)

  • Lee, Byeong-Il;Kim, Kye-Hun;Kim, Jung-Young;Kim, Su-Jin;Lee, Jae-Sung;Min, Jung-Joon;Song, Ho-Chun;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.194-200
    • /
    • 2007
  • Purpose: $^{13}N$-ammonia is a well known radiopharmaceutical for the measurement of a myocardial blood flow (MBF) non-invasively using PET-CT. In this study, we investigated a correlation between MBF obtained from dynamic imaging and myocardial perfusion score (MPS) obtained from static imaging for usefulness of cardiac PET study. Methods: Twelve patients (11 males, 1 female, $57.9{\pm}8.6$ years old) with suspicious coronary artery disease underwent PET-CT scan. Dynamic scans (6 min: $5\;sec\;{\times}\;12,\;10\;sec\;{\times}\;6,\;20\;sec\;{\times}\;3,\;and\;30\;sec\;{\times}\;6$) were initiated simultaneously with bolus injection of 11 MBq/kg $^{13}N-ammonia$ to acquire rest and stress image. Gating image was acquired during 13 minutes continuously. Nine-segment model (4 basal walls, 4 mid walls, and apex) was used for a measurement of MBF. Time activity curve of input function and myocardium was extracted from ROI methods in 9 regions for quantification. The MPS were evaluated using quantitative analysis software. To compare between 20-segment model and 9-segment model, 6 basal segments were excluded and averaged segmental scores were used. Results: There are weak correlation between MBF (rest, 0.18-2.38 ml/min/g; stress, 0.40-4.95 ml/min/g) and MPS (rest 22-91%, stress, 14-90%), however the correlation coefficient between corrected MBF and MPS in rest state was higher than stress state (rest r=0.59; stress r=0.80). As a thickening increased, correlation between MBF and MPS also showed good correlation at each segments. Conclusions: Corrected and translated MPS as its characteristics using $^{13}N$-ammonia showed good correlation with absolute MBF measured by dynamic image in this study. Therefore, we showed MPS is one of good indices which reflect MBF. We anticipate PET-CT could be used as useful tool for evaluation of myocardial function in nuclear cardiac study.

Gender Difference of Accuracy in Detecting Coronary Artery Disease by Myocardial Perfusion SPECT (디피리다몰 심근관류 SPECT를 이용한 관동맥질환 진단에 있어 남녀간의 진단율 비교)

  • Min, Jung-Jun;Bom, Hee-Seung;Song, Ho-Cheon;Jeong, Hwan-Jeong;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.129-136
    • /
    • 1998
  • Purpose: Myocardial SPECT is an effective test for detecting coronary artery disease in the general population. But the diagnostic accuracy between sexes is not defined. The purpose of this study is to compare the diagnostic accuracy between males and females. Materials and Methods: One hundred and seventy seven male and 98 female patients who underwent myocardial SPECT within 1 month of coronary angiography were studied. Myocardial SPECTS were considered abnormal if fixed or reversible perfusion defects were detected. Stenosis severity of ${\geq}$ 50% luminal diameter reduction of any artery defined coronary artery disease (CAD). Results: Overall sensitivity for detection of CAD was 98% in men and 97% in women (p=not significant). However, specificities, accuracies, and positive predictive values (PPV) in men and women were 49% vs 31% (p<0.05), 81% vs 57% (p<0.01), 78% vs 48% (p<0.01), respectively. Diagnostic accuracies for detection of right coronary artery disease were not different in both sexes, however, accuracies for detection of left anterior descending artery disease and left circumflex artery disease were significantly lower in female (p<0.05). Conclusion: A significant difference of diagnostic accuracy between sexes, especially in LAD and LCx disease, was noted. Artifacts from breast attenuation might be a cause for the lower diagnostic accuracy in female.

  • PDF

Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques (조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가)

  • Nam, Ji-Ho;Ki, Yong-Kan;Kim, Dong-Won;Kim, Won-Taek
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The aim of this study is to evaluate and compare the incidence and aspects of myocardial perfusion defects in patients who were subjected to either two-dimensional or three-dimensional simulation techniques for early left-sided breast cancer. The myocardial perfusion defects were determined from using single photon emitted computerized tomography (SPECT) myocardial perfusion images. $\underline{Materials\;and\;Methods}$: Between January 2002 and August 2003, 32 patients were enrolled in this study. The patients were diagnosed as having early (AJCC stage T1-T2N0M0) left-sided breast cancer and were treated with tangential irradiation after breast-conserving surgery and systemic chemotherapy. The patients were divided into two groups according to the type of simulation received: two-dimensional simulation using an X-ray fluoroscope simulator or three-dimensional simulation with a CT simulator. All patients underwent technetium-99m-sestamibi gated perfusion SPECT at least 3 years after radiotherapy. The incidence and area of myocardial perfusion defects were evaluated and were compared in the two groups, and at the same time left ventricular ejection fraction and cardiac wall motion were also analyzed. The cardiac volume included in the radiation fields was calculated and evaluated to check for a correlation between the amount of irradiated cardiac volume and aspects of myocardial perfusion defects. $\underline{Results}$: A myocardial perfusion defect was detected in 11 of 32 patients (34.4%). There were 7 (46.7%) perfusion defect cases in 15 patients who underwent the two-dimensional simulation technique and 4 (23.5%) patients with perfusion defects in the three-dimensional simulation group (p=0.0312). In 10 of 11 patients who had myocardial perfusion changes, the perfusion defects were observed in the cardiac apex. The left ventricular ejection fraction was within the normal range and cardiac wall motion was normal in all patients. The irradiated cardiac volume of patients in the three-dimensional simulation group was less than that of patients who received the two-dimensional simulation technique, but there was no statistical significance as compared to the incidence of perfusion defects. $\underline{Conclusion}$: Radiotherapy with a CT simulator (three-dimensional simulation technique) for early left-sided breast cancer may reduce the size of the irradiated cardiac volume and the incidence of myocardial perfusion defects. Further investigation and a longer follow-up duration are needed to analyze the relationship between myocardial perfusion defects and clinical ischemic heart disease.

Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT (심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Kang, Won-Jun;Kim, Seong-Min;Won, Kyoung-Sook;Lim, Seok-Tae;Hwang, Kyung-Hoon;Lee, Byeong-Il;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.513-518
    • /
    • 2009
  • Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: $63.3{\pm}10.4$ years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

Variations in The Size of The Ischemic Myocardium Due to Differences in The Normal File (Normal File의 차이에 따른 심근 관류결손 크기의 변화)

  • Lee, Jae-Tae;Lee, Kyu-Bo;Heo Jae-Kyeong;Iskandrian Abdulmasshi S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.49-57
    • /
    • 1992
  • 혈관확장제 투여에 의한 약물부하 심근스캔시는 운동부하 심근스캔시와 비교하여 심박출량과 관상 동백 혈류의 증가정도가 달라서 심근내 T1-201의 농도가 달라진다. 그러므로 부하 심근관류스캔의 정량적 판독시에 각각의 부하에 특이적인 Normal file을 사용하지 않으면 이러한 심근내 T1-201 농도의 차이로 인하여 관류 결손의 크기가 다르게 나타날 수 있으리라 추측할 수 있다. 본 연구는 좌전하행지의 유의한 협착이 있는 34명의 단일 혈관 관상동맥 환자에서 이러한 가정이 실제적으로 어떻게 나타나는가를 조사하였다. 환자들은 adenosine 140ug/kg/min을 정맥주사하고 T1-201 SPECT를 실시하였다. 관류결손의 크기는 답차운동부하 T1-201 스캔을 실시한 정상인에서 구한 Normal File (File-ex)과 adenosine T1-201 스캔의 Normal File (File-ad)을 각각 이용하여 만든 극성지도에서 구한 adenosine 심근스캔의 관류결손의 범위지수(extent score)와 중증도지수(severity score)로 표시하였고, 이들의 값을 비교하여 아래의 결과를 얻었다. File-ex로 구한 관류결손의 범위지수는 $19{\pm}13%$였고 File-ad로 구한 범위는 $11{\pm}10%$였다(차이 $8.1{\pm}1.6%$, p=0.0001), 중증도지수는 File-ex를 사용하였을 때 $582{\pm}479$였고 File-ad를 사용하였을때는 $310{\pm}309$였다(차이 $272{\pm}49$, p<0.0001). $50\sim70%$의 중등도의 내경 협착이 있었던 20명의 환자에서는 범위지수는 File-ex와 File-ad에서 각각 $17{\pm}10$$7{\pm}7%$(p=0.001)였고, 70% 이상의 내경 협착이 있었던 14명에서의 범위 지수는 각각 $24{\pm}16$$18{\pm}10%$ (p=0.03)로 모두에서 File-ex를 사용하였을때의 값이 컸다. 이와 같은 성적으로 보아 T1-201 스핀에서 관류결손의 정도를 정량적으로 첨가할 시에는 부하에 특이적인 Normal File을 사용하여야 관류 결손의 정도를 정확하게 추출할 수 있다는 사실을 알 수가 있다. 즉 dipyridamole이나 adenosine부하경사에서 운동부하의 Normal File을 사용하면 관류결손의 정도가 과대평가 된다는 것이다.

  • PDF

Evaluation of Result of CABG by Comparison of Pre-and Post-operative Myocardial SPECT (관동맥우회로술 전후의 디피리다몰 부하/휴식 심근 SPECT를 이용한 수술 결과의 평가)

  • Lee, Dong-Soo;Lee, Won-Woo;Kang, Keon-Wook;Hyun, In-Young;Kim, Ki-Bong;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.86-94
    • /
    • 1996
  • Coronary angiography should be performed to verify the patency of bypass graft if coronary artery disease is said to be surgically corrected. Rest/stress myocardial SPECT could be used as a noninvasive alternative to prove patency of bypass graft and functional significance of graft patency by showing improvement of rest perfusion and perfusion reserve after operation. We evaluated the outcome of coronary artery bypass graft surgery by comparing rest/dipyridamole-stress myocardial SPECT before and after operation. Myocardial SPECT were performed $19{\pm}23$ days before and $108{\pm}19$ days after operation in 44 patients(M:F=25:19). Segmental perfusion were scored with 0(normal) to 3(defect) independently for each image set of rest and stress. Perfusion scores were compared between pre and postoperative images. Rest/stress images of pre and post-operative SPECT were compared in paired sets. Postoperative change of perfusion was determined as no change, improvement or aggravation for each artery territory. Postoperative outcome of patients were analyzed. Overall, 74%(158 segments) of 215 segments which had perfusion decrease before operation showed improvement. Among 60 artery territories, 37 territories(62%) improved. Among 42 patients with perfusion decrease in preoperative SPECT, 21 patients(47%) improved after operation. Severe persistent defects improved in 43%(6/14). We concluded that bypass surgery improved myocardial perfusion in dipyridamole stress induced or persistent decrease and that rest/stress myocardial SPECT could be used as a guide for which artery should be operated.

  • PDF

Experimental Studies on the Effect of Ginsenoside Rg1 Mixtures in an Isolated Rat Heart after Ischemic Arrest and Reperfusion (흰 쥐 적출 심장에서 비작업성 관류 회로를 이용한 인삼 성분 Ginsenoside Rg1 Mixtures의 심근 보호 효과에 관한 실험적 연구)

  • 김동원;신원선;이재영;김범식;조규석;유세영
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.567-575
    • /
    • 1998
  • Panax Ginseng C.A. Meyer has been known for hundreds of years as the most valuable drug having mysterious effects among all the herbal medicines and plants in Korea. Also, many experimental studies have been performed recently that the various effects were identified and applied clinically. So we attempted an experimental study on the effect of ginsenoside Rg1 mixtures in an isolated rat heart with the use of the Langendorff model. The objective of this study was to determine whether this ginsenoside Rg1 mixtures would protect the myocardial injury after ischemic arrest and reperfusion. Isolated rat hearts were allowed to equilibrate for 20 minutes and were then subjected to 15 minutes of normothermic ischemia. After this ischemic period, isolated rat hearts were allowed to reperfusion for 10 minutes(Ischemic Group). In other group , isolated rat hearts were perfused for 60 minutes continuously with normothermia( Normothermic Group). Hemodynamic and biochemical parameters such as heart rate, left ventricular pressure, +dp/dt max, coronary blood flow and cardiac enzymes were measured during initial perfusion, ischemia, reperfusion period (Ischemic group) and 20, 40 and 60 minutes after continuous perfusion(Normothermic group). After completion of the experiment, this data was evaluated and the following results were obtained. 1. Heart rates showed an increase in both ischemic and normothermic experimental groups, but statistically significant differences were not identified. 2. LVP(Left Ventricular Pressure) showed statistically significant differences in both ischemic and normothermic experimental groups(p<0.005, p<0.01). 3. +dp/dt max showed statistically significant differences in both ischemic and normothermic experimental groups(p<0.01, p<0.01). 4. There were no statistically significant differences in coronary blood flow and cardiac cenzymes in all groups, but experimental groups seemed to have better protection and recovery. These results suggest that ginsenoside Rg1 mixtures has a protective effect on the myocardial injury after ischemia and reperfusion.

  • PDF

Characteristic Findings of Exercise ECG Test, Perfusion SPECT and Coronary Angiography in Patients with Exercise Induced Myocardial Stunning (게이트 심근관류 SPECT상 운동 유발성 기절심근을 보이는 환자의 운동부하 심전도, 관류 SPECT 및 심혈관 조영술 소견)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyoung;Bae, Jin-Ho;Jeong, Shin-Young;Park, Hun-Sik;Lee, Jae-Tae;Chae, Shung-Chul;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.225-232
    • /
    • 2004
  • Purpose : Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Materials and Methods : Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV election fraction (LVEF) was $\geq5%$ lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1 %(non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Results : Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs. 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs. 9.2%, p=0.029; severity 13.5 vs. 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis ($80{\sim}99%$) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Conclusion : Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than patients without post-stress LV dysfunction. All of the patients without perfusion defect in stunning group had significant coronary artery stenosis and needed revascularization. Therefore, we suggest that invasive diagnostic procedures and therapeutic interventions might be needed in patients with post-stress LV dysfunction.

Clinical Significance of Myocardial Uptake on F-18 FDG PET/CT Performed in Oncologic Patients (종양 환자의 F-18 FDG PET/CT에서 관찰된 심근 섭취의 임상적 의미)

  • Cho, Ho-Jin;Cho, Arthur;Lee, Jong-Doo;Kang, Won-Jun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.519-525
    • /
    • 2009
  • Purpose: F-18 fluorodeoxyglucose (FDG) uptake of myocardium is influenced by various factors. Increased glycolysis, and subsequent increased F-18 FDG uptake has been reported in ischemic cardiomyopathy. However, clinical significance of incidentally found myocardial F-18 FDG uptake has not been clarified. We retrospectively reviewed the degree and pattern of myocardial uptake in patients without history of ischemic heart disease who underwent torso F-18 FDG PET/CT for evaluation of neoplastic disease. Materials and Methods: From January 2005 to June 2009, 77 patients who underwent F-18 FDG PET/CT and Tc-99m sestamibi stress/rest SPECT within 3 months were enrolled. Results: Of 77 patients, 55 (71.4%) showed increased F-18 FDG uptake in the myocardium. In this population, 40 showed uniform uptake pattern, while 15 showed focal uptake. In patients with uniform uptake, 17 showed decreased uptake in the septum without perfusion defect on myocardial SPECT. Remaining 23 patients showed uniform uptake, with 1 reversible perfusion defect and 1 fixed perfusion defect. In 15 patients with focal uptake, 9 showed increased F-18 FDG uptake in the base, and only 1 of them showed reversible perfusion defect on myocardial SPECT. In the remaining 6 focal uptake group, 4 had reversible perfusion defect in the corresponding wall, and 1 had apical hypertrophy. Conclusion: We demonstrated that septal defect pattern and basal uptake pattern in the myocardium may represent normal variants. Focal myocardial uptake other than normal variants on oncologic torso F-18 FDG PET/CT with routine fasting protocol may suggest ischemic heart disease, thus further evaluation is warranted.

Analysis of Myocardial Function Using Gated Myocardial SPET : Comparison of QGS, 4D-MSPECT Software and Echocardiography (게이트 심근관류 SPECT를 이용한 심기능 분석: 정량분석 소프트웨어 QGS, 4D-MSPECT 및 심초음파법의 비교)

  • Lee, Seok-Mo;Bae, Sang-Kyun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.435-443
    • /
    • 2008
  • Purpose: Gated myocardial perfusion SPECT provides not only myocardial perfusion status but also various functional parameters of left ventricle. We compared left ventricular ejection fraction, end-diastolic volume, LV mass by cardiac SPECT using Quantitative Gated SPECT (QGS), 4D-MSPECT software and standard 2D-echocardiography. Materials and Methods: One hundred fourteen patients (male 51, female 63; 29-85 years old, mean $61.3\;{\pm}\;13.3$ years old) with normal perfusion status on Tc-99m tetrofosmin gated myocardial perfusion SPECT were analyzed retrospectively. Ejection fraction (LVEF), End-diastolic volume (LVED), LV mass (LVM) were calculated using QGS, 4D-MSPECT, and LVEF, LVM using 2D-echocardiography. Statistical analysis including Bland-Altman plot was performed using $MedCalc^{(R)}$ (MedCalc software, Mariakerke, Belgium). Results: The correlation of LVEF between methods was good: 0.95/0.96 (stress/rest) between QGS and 4D-MSPECT, 0.79 between QGS and echocardiography, 0.79 between 4D-MSPECT and echocardiography (p<0.001). Using Bland-Altman plot, the 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -12.7% to 7.3% / from -12.2% to 6.5% (stress/rest). The agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -17.4% to 24.0%, and -14.8% to 27.0% respectively. The correlation of LVM between methods was also good: 0.95 between QGS and 4D-MSPECT, 0.76 between QGS and echocardiography, 0.73 between 4D-MSPECT and echocardiography (p<0.001). The 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -33.8g to 14.1g (stress/rest), The 95% confidence interval of agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -148.7 g to 21.8. g, and -142.8 g to 35.5 g, respectively. Conclusion: There was a good correlation for LVEF, LVEO, LVM among methods (QGS, 4D-MSPECT, echocardiography), but the variance between methods was big. Therefore, the functional parameters by each method cannot be used interchangeably.