Browse > Article

Analysis of Myocardial Function Using Gated Myocardial SPET : Comparison of QGS, 4D-MSPECT Software and Echocardiography  

Lee, Seok-Mo (Department of Nuclear Medicine, Inje University College of Medicine)
Bae, Sang-Kyun (Department of Nuclear Medicine, Inje University College of Medicine)
Publication Information
Nuclear Medicine and Molecular Imaging / v.42, no.6, 2008 , pp. 435-443 More about this Journal
Abstract
Purpose: Gated myocardial perfusion SPECT provides not only myocardial perfusion status but also various functional parameters of left ventricle. We compared left ventricular ejection fraction, end-diastolic volume, LV mass by cardiac SPECT using Quantitative Gated SPECT (QGS), 4D-MSPECT software and standard 2D-echocardiography. Materials and Methods: One hundred fourteen patients (male 51, female 63; 29-85 years old, mean $61.3\;{\pm}\;13.3$ years old) with normal perfusion status on Tc-99m tetrofosmin gated myocardial perfusion SPECT were analyzed retrospectively. Ejection fraction (LVEF), End-diastolic volume (LVED), LV mass (LVM) were calculated using QGS, 4D-MSPECT, and LVEF, LVM using 2D-echocardiography. Statistical analysis including Bland-Altman plot was performed using $MedCalc^{(R)}$ (MedCalc software, Mariakerke, Belgium). Results: The correlation of LVEF between methods was good: 0.95/0.96 (stress/rest) between QGS and 4D-MSPECT, 0.79 between QGS and echocardiography, 0.79 between 4D-MSPECT and echocardiography (p<0.001). Using Bland-Altman plot, the 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -12.7% to 7.3% / from -12.2% to 6.5% (stress/rest). The agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -17.4% to 24.0%, and -14.8% to 27.0% respectively. The correlation of LVM between methods was also good: 0.95 between QGS and 4D-MSPECT, 0.76 between QGS and echocardiography, 0.73 between 4D-MSPECT and echocardiography (p<0.001). The 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -33.8g to 14.1g (stress/rest), The 95% confidence interval of agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -148.7 g to 21.8. g, and -142.8 g to 35.5 g, respectively. Conclusion: There was a good correlation for LVEF, LVEO, LVM among methods (QGS, 4D-MSPECT, echocardiography), but the variance between methods was big. Therefore, the functional parameters by each method cannot be used interchangeably.
Keywords
Tc-99m tetrofosmin gated myocardial perfusion SPECT; QGS; 4D-MSPECT; echocardiography;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Svensson A, Akesson L, Edenbrandt L. Quantification of myocardial perfusion defects using three different software packages. Eur J Nucl Med Mol Imaging 2004;31:229-32   DOI
2 Kwan J, Park K-S, Yang S-S, Lee K-H, Hong E-S, Seo J-K, et al. Echocardiographic assessment of left ventricular systolic function in comparison with automatic quantification of $^{201}Tl$ gated perfusion SPECT. J Cardiovasc Ultrasound 2000;8:226-35
3 Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995;36:2138-47
4 Germano G, Kavanagh PB, Berman DS. An automatic approach to the analysis, quantitation and review of perfusion and function from myocardial perfusion SPECT images. Int J Card Imaging 1997;13:337-46   DOI   ScienceOn
5 Allman KC, Shaw LJ, Hachamovitch R, Udelson JE. Myocardial viability testing and impact of revascularization on prognosis in patients with coronary artery disease and left ventricular dysfunction: A meta-analysis. J Am Coll Cardiol 2002;39:1151-8   DOI   ScienceOn
6 Nakae I, Matsuo S, Koh T, Mitsunami K, Horie M. Left ventricular systolic/diastolic function evaluated by quantitative ECG-gated SPECT: Comparison with echocardiography and plasma BNP analysis. Ann Nucl Med 2005;19:447-54   DOI
7 Henneman MM, Bax JJ, Schuijf JD, Jukema JW, Holman ER, Stokkel MP, et al. Global and regional left ventricular function: A comparison between gated SPECT, 2D echocardiography and multi-slice computed tomography. Eur J Nucl Med Mol Imaging 2006;33:1452-60   DOI   ScienceOn
8 Patel CD, Nadig MR, Kurien S, Barai S, Narang R, Malhotra A. Left ventricular ejection fraction and volumes on rest gated 201Tl perfusion SPECT: Comparison with two-dimensional echocardiography. Nucl Med Commun 2006;27:425-9   DOI   ScienceOn
9 Levy D, Garrison RJ, Savage DD, Kannel WB, Castelli WP. Prognostic implications of echocardiographically determined left ventricular mass in the framingham heart study. N Engl J Med 1990;322:1561-6   DOI   ScienceOn
10 Akinboboye O, Germano G, Idris O, Nichols K, Gopal A, Berman D, et al. Left ventricular mass measured by myocardial perfusion gated SPECT. Relation to three- dimensional echocardiography. Clin Nucl Med 2003;28:392-7   DOI
11 DePuey EG, Rozanski A. Using gated technetium-99msestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med 1995; 36:952-5
12 Schaefer WM, Lipke CS, Nowak B, Kaiser HJ, Reinartz P, Buecker A, et al. Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated $^{18}F-FDG$ PET: Comparison with cardiac MRI. J Nucl Med 2004;45:74-9
13 Iskandrian AE, Germano G, VanDecker W, Ogilby JD, Wolf N, Mintz R, et al. Validation of left ventricular volume measurements by gated SPECT $^{99m}Tc-labeled$ sestamibi imaging. J Nucl Cardiol 1998;5:574-8   DOI   ScienceOn
14 Sharir T, Germano G, Kavanagh PB, Lai S, Cohen I, Lewin HC, et al. Incremental prognostic value of post- stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography. Circulation 1999; 100:1035-42   DOI   ScienceOn
15 White HD, Norris RM, Brown MA, Brandt PW, Whitlock RM, Wild CJ. Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 1987;76:44-51   DOI   ScienceOn
16 Smanio PE, Watson DD, Segalla DL, Vinson EL, Smith WH, Beller GA. Value of gating of technetium-99m sestamibi singlephoton emission computed tomographic imaging. J Am Coll Cardiol 1997;30:1687-92   DOI   ScienceOn
17 Casale PN, Devereux RB, Milner M, Zullo G, Harshfield GA, Pickering TG, et al. Value of echocardiographic measurement of left ventricular mass in predicting cardiovascular morbid events in hypertensive men. Ann Intern Med 1986;105:173-8   DOI   ScienceOn
18 Diamond JA, Rodriguez FJ, Croft LB, Henzlova MJ. Normal value for left ventricular mass by myocardial SPECT imaging. J Nucl Cardiol 2001;8:S135
19 Pai M, Yang YJ, Im KC, Hong IK, Yun SC, Kang DH, et al. Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography. Int J Cardiovasc Imaging 2006;22:671-81   DOI
20 Haider AW, Larson MG, Benjamin EJ, Levy D. Increased left ventricular mass and hypertrophy are associated with increased risk for sudden death. J Am Coll Cardiol 1998;32:1454-9   DOI   ScienceOn
21 Nakajima K, Higuchi T, Taki J, Kawano M, Tonami N. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: Comparison of 4 software programs. J Nucl Med 2001;42:1571-8
22 Hammermeister KE, DeRouen TA, Dodge HT. Variables predictive of survival in patients with coronary disease. Selection by univariate and multivariate analyses from the clinical, electrocardiographic, exercise, arteriographic, and quantitative angiographic evaluations. Circulation 1979;59:421-30   DOI   ScienceOn
23 Lum DP, Coel MN. Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT. Nucl Med Commun 2003;24:259-66   DOI   ScienceOn
24 Vourvouri EC, Poldermans D, Bax JJ, Sianos G, Sozzi FB, Schinkel AF, et al. Evaluation of left ventricular function and volumes in patients with ischaemic cardiomyopathy: Gated single-photon emission computed tomography versus twodimensional echocardiography. Eur J Nucl Med 2001;28:1610-5   DOI   ScienceOn
25 Maruyama K, Hasegawa S, Nakatani D, Paul AK, Kusuoka H, Nishimura T, et al. Left ventricular mass index measured by quantitative gated myocardial SPECT with $^{99m}Tc-tetrofosmin$: A comparison with echocardiography. Ann Nucl Med 2003;17:31-9   DOI
26 Cleland JG, Pennell DJ, Ray SG, Coats AJ, Macfarlane PW, Murray GD, et al. Myocardial viability as a determinant of the ejection fraction response to carvedilol in patients with heart failure (Christmas trial): Randomised controlled trial. Lancet 2003;362:14-21   DOI   ScienceOn
27 Koren MJ, Devereux RB, Casale PN, Savage DD, Laragh JH. Relation of left ventricular mass and geometry to morbidity and mortality in uncomplicated essential hypertension. Ann Intern Med 1991;114:345-52   DOI   ScienceOn
28 Nichols K, Santana CA, Folks R, Krawczynska E, Cooke CD, Faber TL, et al. Comparison between ECTb and QGS for assessment of left ventricular function from gated myocardial perfusion SPECT. J Nucl Cardiol 2002;9:285-93   DOI   ScienceOn
29 Jeong Y, Park T, Cha K, Kim M, Kim Y, Kang D-Y. Reference values of functional parameters in gated myocardial perfusion SPECT : Comparison with QGS and 4DM program. Korean J Nucl Med 2005;39:430-7   과학기술학회마을
30 Ioannidis JP, Trikalinos TA, Danias PG. Electrocardiogramgated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: A meta-analysis. J Am Coll Cardiol 2002;39:2059-68   DOI   ScienceOn
31 Wolak A, Slomka PJ, Fish MB, Lorenzo S, Acampa W, Berman DS, et al. Quantitative myocardial-perfusion SPECT: Comparison of three state-of-the-art software packages. J Nucl Cardiol 2008;15:27-34   DOI   ScienceOn
32 Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10
33 Schaefer WM, Lipke CS, Standke D, Kuhl HP, Nowak B, Kaiser HJ, et al. Quantification of left ventricular volumes and ejection fraction from gated $^{99m}Tc-MIBI$ SPECT: MRI validation and comparison of the Emory cardiac tool box with QGS and 4D-MSPECT. J Nucl Med 2005;46:1256-63