• Title/Summary/Keyword: 실면적

Search Result 277, Processing Time 0.022 seconds

Determination of Sizes of the Pump Rooms in Korean Nuclear Power Plants (한국형 원자력발전소 펌프실 면적 산정 방안)

  • Lee, Hyo-Sung;Koh, Churl-Kyun;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.9 no.2
    • /
    • pp.36-41
    • /
    • 2013
  • For areas installed with one pump, the trend for expected sizes of pump room areas is observed once pump power and floor dimensions are provided. However, these pump rooms with auxiliary charging pumps, turbine driven auxiliary feedwater pumps, and pump rooms with a separate valve room have unique ways to determine the pump room area. No definite trends are identified for areas installed with two pumps using pump power and floor dimensions. The relationship between pump power and floor dimensions is also unable to be found.

  • PDF

Design of Daylighting Aperture Using Daylight Factor Method and its Evaluation by Distribution of Sky Component (Daylight Factor Method를 이용한 채광창의 설계)

  • 지철근;권영혜
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.1
    • /
    • pp.58-63
    • /
    • 1989
  • 이등분한 실의 주광율(Daylight Factor)의 비를 규제도의 지수로서 Lumen Method와 같이 정하고, 이를 만족하는 실의 깊이를 검토한 후, 설계 평균 주광율을 만족하는 창의 면적을 구하였다. 본 논문에서 제안한 창의 면적 자체가 다른 벽면의 면적 변화에 영향을 주고 있음을 고려하지 않은 종래의 방법을 개선하였다. 이후 주광율 요소 중 가장 지배적인 양인 운천공으로부터 입사하는 성분(SCo: Sky Component from overcast Sky)의 분포를 창의 위치와 형태를 변화시켜 조사, 평가하였다.

  • PDF

Assessment of Radar Precipitation Applicability for Watershed Area Precipitation Estimation (유역 면적강수량 산정을 위한 레이더 강수량 활용성 평가)

  • Kim, Tae-Jeong;Song, Jae-Hyun;Lee, Sung-Ho;Lee, Chung-Dea
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.441-441
    • /
    • 2022
  • 국내외적으로 정확한 수문기상 현상의 관측에 대한 수요가 증가하고 있다. 이를 위하여 기존의 재래식 관측장비의 한계성을 극복하고자 첨단장비가 활발하게 도입되고 있다. 우리나라는 관악산 기상레이더를 시작으로 하천 및 도심지의 돌발홍수 정보를 제공하고자 강우레이더 신설을 진행하고 있다. 본 연구에서는 하천유역조사 사업에서 티센다각형법을 이용하여 유역단위 면적평균강수량을 산정하는 경우 영동권역과 같이 지상관측소 밀집도 부족으로 인하여 발생하는 강수량의 공간적 편차를 정량적으로 검토하고자 전국 하천유역에 대하여 1.5km Constant Altitude PPI(CAPPI) 합성장의 레이더 강수량을 활용한 유역단위 면적평균강수량을 산정하고 지상 강수량과 통계적 적합도(goodness of fit)를 평가하였다. 지상 강수량을 활용한 유역단위 면적평균강수량과 레이더 강수량은 높은 상관성을 나타내었으나 관측기법의 특성으로 발생하는 정량적 편의(bias) 보정의 필요성을 확인하였다. 시공간적으로 고해상도의 레이더 강수정보를 활용하기 위하여 활용 목적에 적합한 레이더 강수량 보정기법의 개발이 필요할 것으로 사료된다. 또한, 대용량 레이더 자료를 안정적으로 처리할 수 있는 플랫폼 및 레이더 강수량 품질관리 체계 구축을 통하여 수문조사 및 수문해석 지원이 가능할 것으로 판단된다.

  • PDF

Optimization and Improvements of Field Uniformity in a Reverberation Chamber with Schroeder Diffusers (Schroeder 확산기를 이용한 전자파 잔향실내의 필드 균일도 향상 및 최적화에 관한 연구)

  • Kim, Jung-Hoon;Rhee, Joong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.4 s.119
    • /
    • pp.372-378
    • /
    • 2007
  • This paper presents an improvement of field uniformity in a reverberation chamber with QRDs(Quadratic Residue Diffuser) and also shows the optimal dimension of the QRDs. The QRD is designed for $1{\sim}3\;GHz$ frequency band and the FDTD(finite-Difference Time-Domain) method is used to analyze the field characteristics. At 2 GHz, the standard deviation of test volume in the reverberation chamber is the smallest when the QRD has $30{\sim}60\;%$ coverage of one side of the reverberation chamber and the field uniformity is worsened when the coverage of the QRD is either below 20 % or above 70 % of the area of the side wall. Particularly, the standard deviation of test volume in the reverberation chamber with 30 % coverage of QRD is improved by 1.53 dB compared to that of the reference chamber with no QRDs.

A Case Study on the Spatial Configuration and Allocation of Catering Facilities of Newly-Built Elementary Schools in Sejong City (세종시 신설초등학교의 조리장 공간구성과 면적에 관한 사례 연구)

  • Song, Byung-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.433-442
    • /
    • 2017
  • This study consists of five case studies of the catering facilities of newly-built elementary schools' in Sejong City, regarding the spatial configuration and allocation. The analysis indicated that the space allocated in the cooking area in the five schools compared to the standard was as follows: School A; 99.2%, B; 91.1%, C; 81.4%, D; 110.8%, E; 88.1%. Accordingly, the cooking area was close to, or slightly above the standard; nevertheless, other areas in the facilities were not allocated sufficient space and were not appropriately planned. Among the other findings, the receiving areas of three schools were not even planned, and the receiving works were carried out in the pre-preparation area. Considering the flow of the dish-washing process, the width of the room should be at least 3.6 meters with a passage width of 1.6 meters, and easy access to the cooking and dining areas must be equipped. An interview with all five supervisors showed that most complaints focused on the cooking and dishwashing areas, whereas there were none in the storage and workers' area. The result highlights the importance of the cooking and dishwashing areas as the main functions in catering facilities, and future planning strategies should consider this aspect.

Improved Field Uniformity Characteristics in a Reverberation Chamber with a CRD (CRD를 이용한 전자파 잔향실 내 전기장 균일도 향상)

  • Son, Yong-Ho;Rhee, Joong-Geun;Kim, Jung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.12
    • /
    • pp.79-84
    • /
    • 2007
  • This paper presents an improved field uniformity in a reverberation chamber, that can be alternatively used for the analysis and the measurement of electromagnetic interference and immunity, with a designed CRD(Cubical Residue Diffuser) that have various dimensions. The Schroeder type CRD is designed for $1\sim3$ GHz band and the FDTD(Finite Difference Time Domain) method is used to analyze the field characteristics. At 2 GHz, the standard deviation of test volume in the reverberation chamber is the smallest and has a good field distribution with a CRD of $40\sim80%$ dimension of one side of the reverberation chamber. The Electric field uniformity gets worse when the dimension of a CRD is either below 40 % or above 80 % of the side wall. The result shows that the standard deviation of the test volume in the reverberation chamber with a CRD of 44 % dimension is improved by 1 dB compared with that of the reverberation chamber with a CRD of 100 % dimension.

Analysis of Pattern Change of Real Transaction Price of Apartment in Seoul (서울시 아파트 실거래가의 변화패턴 분석)

  • Kim, Jung Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.1
    • /
    • pp.63-70
    • /
    • 2014
  • This study is to analyze impact of geography and timing on the real transactions prices of apartment complexes in Seoul using data provided by the Ministry of Land, Infrastructure and Transport. The average real transactions and location data of apartment complex was combined into the GIS data. First, the pattern of apartment real transaction price change by period and by area was analyzed by kriging, the one of the spatial interpolation technique. Second, to analyze the pattern of apartment market price change by administrative district(administrative 'Dong' unit), the average of market price per unit area was calculated and converted to Moran I value, which was used to analyze the clustering level of the real transaction price. Through the analysis, spatial-temporal distribution pattern can be found and the type of change can be forecasted. Therefore, this study can be referred as of the base data research for the housing or local policies. Also, the regional unbalanced apartment price can be presented by analyzing the vertical pattern of the change in the time series and the horizontal pattern of the change based on GIS.

An Experimental Study on Optimum Design of Half-Wave Resonators for Combustion Stabilization (연소 불안정 억제를 위한 반파장 공명기 최적 설계 조건에 대한 실험적 연구)

  • Park, Ju-Hyun;Sohn, Chae-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.11-14
    • /
    • 2008
  • Acoustic design parameters of a half-wave resonator are studied experimentally for acoustic stability in a model acoustic tube. According to standard acoustic-test procedures, acoustic-pressure signals are measured. Quantitative acoustic properties of sound absorption coefficient are evaluated and thereby, the acoustic damping capacity of the resonator is characterized. The diameter and the number of a half-wave resonator and the diameter of the tube are selected as design parameters for optimal tuning of the resonator. Optimum acoustic damping capacity is observed at smaller open area ratio as the resonator diameter increases.

  • PDF

A Study on the Characteristics of Area and Spatial Elements Based on the Building Size of Childcare Center (보육시설 평면사례분석을 통한 시설규모별 소요실 및 면적특성 분석)

  • Park, Jung-A;Choi, Mock-Wha;Kim, Young-Aee
    • Journal of the Korean housing association
    • /
    • v.22 no.1
    • /
    • pp.65-73
    • /
    • 2011
  • The purpose of this study is to find out the characteristics of area and spatial elements according to the building size and provide the guidelines for space planning of the child care center. This study used the content analysis method and analysis was made on the floor plans for 51 cases and the floor plans were converted to Autocad drawings to analyze the area. The results of this study were as follows; 1) Child care centers over 70% were single-attached building types which made it possible for creating outdoor environments for children. However, most small-size centers which had under 50 children did not have the facilities for outdoor activities. 2) In terms of spatial elements, the basic spaces of the small-size center were the classroom, bathroom, kitchen, office and reference room. The medium or large size centers had extra rooms for special activities and service spaces in addition to the basic spaces. 3) Classroom area per child was 2.65 m2 on average. Space composition ratio on average for care, staff, and service was programmed by 57%, 9%, 34% respectively. Small-size center had relatively more care space when compared to the others. In the case of large-size centers, there was a tendency that service space was increased, but care space was decreased.