• Title/Summary/Keyword: 실내 위치확인시스템

Search Result 176, Processing Time 0.023 seconds

Precision Improvement of Indoor Wireless Positioning by Considering Clock Offsets and Wireless Synchronization (클럭 오프셋과 무선동기를 고려한 실내 무선측위 정밀도 향상 기법)

  • Lim, Erang;Kang, Jimyung;Lee, Soonwoo;Park, Youngjin;Lee, Woncheol;Shin, Yoan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.10
    • /
    • pp.894-900
    • /
    • 2012
  • Indoor wireless positioning system uses ranging information of beacons in order to precisely estimate a tag location. To estimate distance between each beacons and tag, the system calculates arrival time of a tag pulse with clock of each beacon including independent clock offset. This clock offset seriously affects the performance of ranging and positioning. We propose in this paper a clock offset compensation method to solve this problem. To verify the performance of the proposed method, we simulated location estimation with random clock offset between -1,000ppm and 1,000ppm, and the result shows that the proposed scheme effectively solves the clock offset problem.

Design and Implementation of Multi-Sensor-based Vehicle Localization and Tracking System (멀티센서 기반 차량 위치인식 시스템의 설계 및 구현)

  • Jang, Yoon-Ho;Nam, Sang-Kyoon;Bae, Sang-Jun;Sung, Tae-Kyung;Kwak, Kyung-Sup
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.6
    • /
    • pp.121-130
    • /
    • 2009
  • In this paper, Gaussian probability distribution model based multi-sensor data fusion algorithm is proposed for a vehicular location awareness system. Conventional vehicular location awareness systems are operated by GPS (Global Positioning System). However, the conventional system is not working in the indoor of building or urban area where the receiver is difficult to receive the signal from satellites. A method which is combined GPS and UWB (Ultra Wide-Band) has developed to improve this problem. However, vehicular is difficult to receive seamless location information since the measurement systems by both GPS and UWB convert the vehicle's movement information separately at each sensor. In this paper, normalized probability distribution model based Hybrid UWB/GPS is proposed by utilizing GPS location data and UWB sensor data. Therefore the proposed system provides information with seamless and location flexible properties. The proposed system tested by Ubisense and Asen GPS in the $12m{\times}8m$ outdoor environments. As a result, the proposed system has improved performance for accurateness and connection ability between devices to support various CNS (Car Navigation System).

  • PDF

The study on the selection of operating conditions of the precipitation heating system for observation of snowfall in winter (겨울철 강설 관측을 위한 강수량계 가열 시스템 운영 조건 선정에 관한 연구)

  • Kim, Byeongtaek;Hwang, Sungeun;Lee, Youngtae;Kim, Minhoo;Hwang, Hyunjun;In, Sora;Yun, Jinah;Kim, Kihoon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.7
    • /
    • pp.461-470
    • /
    • 2023
  • The purpose of this research is to derive the optimal temperature, location, and heating control system for a tipping bucket rain gauge heating system used for observing snowfall during winter. We conducted indoor and outdoor experiments by manufacturing a tipping bucket rain gauge that can be variably controlled for heating at the funnel, exterior, and interior, and indoor and outdoor. The indoor experiments involved using a temperature and humidity chamber to compare the performance and derive the appropriate temperature of the precipitation gauge heating system. Subsequently, the outdoor experiments were carried out at the Cloud Physics Observation Center located in Daeguallyeong, heavy snowfall region, to validate the findings. The analysis result was derived that the heating temperature of the funnel should be set at the 10 to 30℃, while the internal heating temperature should be 70℃. Furthermore, the optimal locations for the heating devices, which aim to minimize measurement delay, were identified as the exterior of the rain gauge, the rim of the funnel, and the vertical surface of the funnel. Our result shows that used as the basis for the operating conditions of precipitation gauge heating systems for solid precipitation measurement in winter.

A Study on Fisheye Lens based Features on the Ceiling for Self-Localization (실내 환경에서 자기위치 인식을 위한 어안렌즈 기반의 천장의 특징점 모델 연구)

  • Choi, Chul-Hee;Choi, Byung-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.4
    • /
    • pp.442-448
    • /
    • 2011
  • There are many research results about a self-localization technique of mobile robot. In this paper we present a self-localization technique based on the features of ceiling vision using a fisheye lens. The features obtained by SIFT(Scale Invariant Feature Transform) can be used to be matched between the previous image and the current image and then its optimal function is derived. The fisheye lens causes some distortion on its images naturally. So it must be calibrated by some algorithm. We here propose some methods for calibration of distorted images and design of a geometric fitness model. The proposed method is applied to laboratory and aile environment. We show its feasibility at some indoor environment.

A Study on the Technology Development of User-based Home Automation Service (사용자 위치기반 홈오토메이션 서비스 기술 개발에 관한 연구)

  • Lee, Jung-Gi;Lee, Yeong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.327-332
    • /
    • 2017
  • As Internet of Things (IoT) technology advances, there is a growing demand for location-based services (LBSs) to identify users' mobility and identity. The initial LBS system was mainly used to measure position information by measuring the phase of a signal transmitted from a global positioning system (GPS) satellite or by measuring distance to a satellite by tracking the code of a carrier signal. However, the use of GPS satellites is ineffective, because it is difficult to receive satellite signals indoors. Therefore, research on wireless communications systems like ultra-wide band (UWB), radio frequency identification (RFID), and ZigBee are being actively pursued for location recognition technology that can be utilized in an indoor environment. In this paper, we propose an LBS system that includes the 2.45GHz band for chirp spread spectrum (CSS), and the 3.1-10.6GHz band and the 250-750MHz bands for UWB using the IEEE 802.15.4a standard for low power-based location recognition. As a result, we confirmed that the 2.45GHz Industrial, Scientific and Medical (ISM) band RF transceiver and the ranging function can be realized in the hardware and has 0dBm output power.

The 3-Dimensional Localization System Based on Beacon Expansion and Coordinate-Space Disassembly (비컨노드 확장과 좌표공간 분해 기반 3차원 위치인식시스템)

  • Lee, Ho Chul;Lee, Dong Myung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.1
    • /
    • pp.80-86
    • /
    • 2013
  • The 3-Dimensional(3D) localization system based on beacon expansion and coordinate-space disassembly for the design of the 3D localization system in indoor environment is proposed and the performance of the proposed system is analyzed in this paper. The localization ratio of the 3D localization system adapts the proposed algorithm is analyzed by the calculation of errors occurred in the coordinates that the mobile node locates. It is indicated that the average error distance of the 3D localization system adapts the proposed algorithm is less than that of the 3D localization system not adapts the proposed algorithm as 0.47m. The localization average distance error in 12 coordinates is indicated that the 1.5m case is less than 2.5m case as 0.38m by some experimentations under the condition that the distances between the ceiling and the mobile node are 1.5m and 2.5m measured from the ceiling respectively. It is seen that the 3D localization system based on beacon expansion and coordinate-space disassembly can improved the degradation of the quality of service that is caused by some conditions and performance differences in sensors.

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

A Kalman filter with sensor fusion for indoor position estimation (실내 측위 추정을 위한 센서 융합과 결합된 칼만 필터)

  • Janghoon Yang
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.6
    • /
    • pp.441-449
    • /
    • 2021
  • With advances in autonomous vehicles, there is a growing demand for more accurate position estimation. Especially, this is a case for a moving robot for the indoor operation which necessitates the higher accuracy in position estimation when the robot is required to execute the task at a predestined location. Thus, a method for improving the position estimation which is applicable to both the fixed and the moving object is proposed. The proposed method exploits the initial position estimation from Bluetooth beacon signals as observation signals. Then, it estimates the gravitational acceleration applied to each axis in an inertial frame coordinate through computing roll and pitch angles and combining them with magnetometer measurements to compute yaw angle. Finally, it refines the control inputs for an object with motion dynamics by computing acceleration on each axis, which is used for improving the performance of Kalman filter. The experimental assessment of the proposed algorithm shows that it improves the position estimation accuracy in comparison to a conventional Kalman filter in terms of average error distance at both the fixed and moving states.

Research to improve the performance of self localization of mobile robot utilizing video information of CCTV (CCTV 영상 정보를 활용한 이동 로봇의 자기 위치 추정 성능 향상을 위한 연구)

  • Park, Jong-Ho;Jeon, Young-Pil;Ryu, Ji-Hyoung;Yu, Dong-Hyun;Chong, Kil-To
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6420-6426
    • /
    • 2013
  • The indoor areas for the commercial use of automatic monitoring systems of mobile robot localization improves the cognitive abilities and the needs of the environment with this emerging and existing mobile robot localization, and object recognition methods commonly around its great sensor are leveraged. On the other hand, there is a difficulty with a problem-solving self-location estimation in indoor mobile robots using only the sensors of the robot. Therefore, in this paper, a self-position estimation method for an enhanced and effective mobile robot is proposed using a marker and CCTV video that is already installed in the building. In particular, after recognizing a square mobile robot and the object from the input image, and the vertices were confirmed, the feature points of the marker were found, and marker recognition was then performed. First, a self-position estimation of the mobile robot was performed according to the relationship of the image marker and a coordinate transformation was performed. In particular, the estimation was converted to an absolute coordinate value based on CCTV information, such as robots and obstacles. The study results can be used to make a convenient self-position estimation of the robot in the indoor areas to verify the self-position estimation method of the mobile robot. In addition, experimental operation was performed based on the actual robot system.

Performance of Ultra Wideband M-ary Pulse Position Modulated Impulse Radio Systems (초광대역 시간 M 진 펄스 위치 변조 임펄스 무선 전송 시스템의 성능)

  • 안진철;박광희;신요안
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.11A
    • /
    • pp.1682-1690
    • /
    • 2000
  • 최근들어 초광대역 시간 도약 임펄스 무선 전송(ultra wideband time hopping impulse radio; 이하 IR) 기술이 실내 무선 LAN이나 군용 무선 통신 시스템 등을위한 새로운대역 확산 전송 방식으로서 큰 관심을 모으고 있다 IR 시스템은 1(nsec) 이하의 매우 짧은 펄스폭의 펄스 위치 변조(pulse position modulation)된 가우시안 모노사이클 펄스열을 이용함으로서 매우작은 크기 의수 GHz에 이르는 초광대역 스펙트럼을 가지며 기존의 통신 시스템에 거의 간섭을 미치지 않으면서 사용 가능하다. 본 논문에서는 IR 시스템에 M진 (M-ary) PPM 방식을 적용하는 경우의 성능을 평가하였다. 특시 의사 잡음 부호 발생기와 10진 변환기(decimator)로 구성된 시간 도약 패턴을 사용하여 다원 접속 간섭이 배제되는 부가성 백색 가우시안 잡음 채널 하의 동기식(synchronous) IR 시스템에서, 심벌 수, M, 가우시안 모노사이클 펄스 폭 $\tau$$_{p}$, PPM에서 펄스 간 간격$\delta$, 펄스 반복 횟수 N$_{s}$ 등과 같은 다양한 시스템 파라미터의 조합에 따른 성능 변화를 모의 실험을 통해 확인하였으며, 이러한 결과를 통해 비트 오율, 시스템 복잡도 및 전송율 등의 사양에 따라 적합한 M 진 PPM IR 시스템의 구성 방안에 대한 근거를 제공하였다.

  • PDF