• Title/Summary/Keyword: 실내피난

Search Result 46, Processing Time 0.027 seconds

A Study on the Optimized Announcement Based Evacuation Guidance Using Haas Effect (선행음 효과를 이용한 최적의 음성피난유도음에 관한 연구)

  • Baek, Eun-Sun;Kim, Sun-Woo;Baek, Geon-Jong;Shin, Hoon;Song, Min-Jeong;Kook, Chan
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.101-106
    • /
    • 2011
  • In case of an emergency such as a fire on a building and there is a need to evacuate the occupant in that building, it is important to have the guidance information effectively delivered to the evacuating occupants to guide them toward a safe direction using audio sensual media. And, it is also very important to prevent the evacuating occupants getting lost or falling astray, away from the direction toward safety. The purpose of this study, in this respect, is to examine the possible application of the precedent sound effect, with which the evacuating occupants may get a sense of the direction where the announcement comes from. With such an effect, an experiment was conducted to measure the extent to which people can hear the preceding and the following sound in terms of the acoustic pressure level changes and delay time changes, with a view to make the optimal evacuation-guidance announcement or sound. The optimal evacuation guidance sound (announcement) per each of the experimental indoors environments were as follows; 1) Regarding the optimal condition for the evacuation guidance announcement sound in the space of a lecture room, the direction of the advanced sound is positively recognized when the follow-up sound has the delaying time of 10 ms~50 ms in comparison with the advanced sound or when there is no difference between the acoustic pressures of the advanced and follow-up sounds or the acoustic pressure of the advanced sound is higher than that of the follow-up sound. 2) Regarding the optimal evacuation guidance announcement sound in the space of a hall, the advanced sound is positively recognized when the follow-up sound has the delaying time of 20 ms~60 ms in comparison with the advanced sound. 3) Regarding the optimal evacuation guidance announcement sound in the space of a gymnasium, the advanced sound is positively recognized when the follow-up sound has the delaying time of 10 ms~40 ms in comparison with the advanced sound or when the sound pressure of the advanced sound has a higher level than or the same level as that of the follow-up sound.

A Study on Fire Evacuation Guidance System using Indoor Spatial Information from Beacon (실내공간정보를 활용한 비콘기반 화재위험감지와 재실자 피난지원 서비스에 관한 연구)

  • Lee, Sun Min;Kim, Tae-Kyung;Hong, Sung-Moon;Kim, Ju-hyung;Kim, Jae-Jun
    • Journal of KIBIM
    • /
    • v.6 no.3
    • /
    • pp.15-23
    • /
    • 2016
  • The purpose of this study is to present the possibility of adopting beacons to implement the fire evacuation guidance system in order to reduce the evacuation time for a fire in complex buildings. A beacon-based evacuation system can quickly detect a fire's origin, optimal path of evacuation involved with the exits and the location of evacuees using information collected by the proposed system. The assessment is conducted by integrating different scenario models including fire simulation. Based on the research result, beacon is an effective tool to warn potential hazards or to provide early detection and a safe escape.

A Study on the System Development of Safety Control Plane at Home Using the Personal Digital Assistant (정보단말을 활용한 실내안전학습 시스템의 개발연구)

  • Kang, Shinwook;So, Soo Hyun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.84-90
    • /
    • 2014
  • During earthquake, the safety control plane at home is very important to prepare the turnover and falling accident of furniture as a disaster measures. But a lot of people might not have knowledge and education on the safety control plane at home such as the fixing of furniture. Therefore, in this study, the test application of iPhone was developed to enlighten and educate them using the smart phone. Through this application, residents, furniture store employees, moving service workers, builders and etc. will be able to understand the safety control plane at home.

Study on the direction detection based on audible and non-audible signals using smart devices (스마트 디바이스를 활용한 가청, 비가청 신호 기반 피난방향 탐지 기법 연구)

  • Hyun, Byeongchun;Yun, Younguk;Park, Yohan;Kim, Youngok
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.1
    • /
    • pp.51-58
    • /
    • 2017
  • This paper proposes a direction estimation scheme with directional speaker and smart device for evacuation guidance. When there is worst disaster environment filled with smoke and noisy sound, evacuee can not get any information about evacuation routes. The proposed scheme can be used for detecting evacuation routes with audible and inaudible signal from directional speaker. At this point, evacuee can get evacuee guidance by using smartphone application that the proposed scheme is applied. The performance of the proposed scheme is evaluated by experiment with three different types of smart devices in large indoor environment. The purpose of experiment is to detect the direction of transmitted signal from directional speaker. Therefore, The experiment is conducted by analyzing the strength of transmitted signal by distance. The experimental results show that even if the smart device is located up to 20m away from the speaker, it is possible to detect the sending direction of the signal. We confirmed the possibility of the proposed technology in 8kHz and 20kHz signal detection by smart device.

Study on building room fire development stages (건축물 실내화재의 단계에 대한 연구)

  • Cha, Jong-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.169-172
    • /
    • 2008
  • The purpose of this paper is to summarize characteristics of fire growth stages, combustion proceeding, human behavior factors against fire, fire active protections, fire alarms in order to perform public safety and protection, personnel property protection, with identification of economic analysis aspects based on respective stages classified as fire generation- fire growth- flashover- fire extinction, which is differ from previous studies that based on distinct concepts such as fire stages, escapes, building construction, fire sensing.

  • PDF

The process of Indoor Space Combination Network Model based on object oriented CAD data and its application (CAD 객체 정보에 기초한 공간 정보 네트워크 모델의 구성 프로세스와 활용방안)

  • Oh, Jung-Woo;Kim, Kyung-Hwan;Lee, Yoon-Sun;Ahn, Byung-Ju;Kim, Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.6
    • /
    • pp.129-136
    • /
    • 2008
  • There is a tremendous need for an effective indoor facility management since the building are tend to be built taller and bigger due to latest technology. Also, information that is continuously used and transferred during the design and construction phase is emerging due to 3D object-oriented CAD. Therefore, a system that will use such information for facility management should be developed. In this study, we have defined a process that will automatically create an spatial network model and also verified the usability by establishing an sample model. As a result, an effective spatial network has been generated and an evacuation path finder was found efficiently.

Numerical Study of the Factors Affecting Fire Flow Velocity in the Case of Interior Fire in an Apartment Building (공동주택 화재 시 화재풍속에 영향을 미치는 인자들에 관한 수치해석적 연구)

  • Kim, Byeongjun;Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.14-19
    • /
    • 2016
  • When an interior fire occurs in an apartment building, pollution of the entrance area by fire smoke before an air fan operates makes the evacuation of people very difficult aswhen the fire doors are opened. Numerical simulations using Fire Dynamics Simulator were conducted to determine the impact of a sprinkler on the fire flow velocity. The fire flow velocity was compared depending on the presence of sprinklers and the sprayed droplet size. The configuration and actual dimensions of an apartment building were used in the numerical simulations. The simulation results showed that fire flow velocity becomes smaller when a sprinkler is installed. In addition, the smaller droplet size results in a smaller fire flow velocity because smaller droplets can be evaporated more easily.

An Analysis of the Appropriate Number of People Per Apartment Household According to NFPA 101 (NFPA 101에 의한 아파트 한 세대당 적정 수용인원 분석)

  • Cho, Ji-Eun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.331-337
    • /
    • 2020
  • The study analyzes the appropriate number of people per a household by applying an evacuation simulation to a 27-floor apartment in accordance with the NFPA 101 standard. The results of the analysis are as follows. First, if there are three people residing in each household, there would be 156 households in total, of which 85.25% were evacuated within 5 minutes. Second, 208 households with 4 residents were evacuated within 5 minutes. Third, if there are five people residing in each household, there would be a total of 260 households and 71.92% of residents were evacuated within 5 minutes. Lastly, 62.82% of the 312 households, each consisting of 6 people, were evacuated within 5 minutes. Measures to reduce evacuation time include determining the width of the stairs according to the number of people indoors, the number of floors in the building, the slope of stairs, and the users' characteristics, the design reflecting the ventilation conditions of the stairs, the installment of outdoor evacuation stairs, two-way stairs, evacuation lift, and the installation of an evacuation safety zone for people to evacuate outside of the building in the middle floors. In addition, measures, such as the mandatory installation of automatic emergency door open-close device to the rooftop, are required to facilitate rooftop evacuation.

Field Experiment on Influence of Stack Effect to Pressure Differential System for Smoke Control (연돌효과가 급기가압 제연시스템에 미치는 영향에 대한 현장실험)

  • Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.194-200
    • /
    • 2008
  • In order to design and operate successfully the pressure differential system for smoke control which uses difference of pressure between compartments of building, architectural factors affecting the pressure field of building should be examined and the stack effect is one of the important factors. The field experiments on pressure field in two buildings of 21 stories and 31 stories in summer and winter season with regard to on/off condition of the pressure differential system are carried out to evaluate the influence of stack effect to evacuation and smoke management of high-rise building. In winter season when the stack effect increases, as the pressure differential system starts to operate, the pressure in upper stair rises largely due to the combination effect of the air infiltration from lobby to stair and the stack effect.

Pressure Differentials in the Elevator Lobby Depending on the Evacuation Scenarios (피난 시나리오에 따른 승강장 부속실 차압 특성 연구)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.38-43
    • /
    • 2007
  • The aim of this paper is to investigate the change of pressure differential and smoke propagation characteristics in the elevator lobby with the resident's evacuation scenarios using fire modelling technique. The results showed absolute pressures in the fire room and elevator lobby can significantly increase to cause fire door to the stairway unclosed once it is open. This is due to constant pressure differentials, the increasing reference pressure of fire lobby and pressure leak from elevator lobby to fire lobby. Smoke exhaust mechanism was needed to prevent the continuous pressure rise in the living room. Over 200 Pa was expected upon closing the door during pressurization, which provide difficulties in opening the door for next refugee. Opening both fire door and entrance door may induce smoke flow from fire room to elevator lobby and stairway.