• Title/Summary/Keyword: 실내용적

Search Result 26, Processing Time 0.026 seconds

Assesment of Indoor Radon Gas Concentration Change of College (대학의 실내 라돈가스 농도의 변화 평가)

  • Park, Hoon-Hee;Jeong, Euihwan;Kim, Hak-Jae;Lee, Juyoung;Lyu, Kwang Yeul
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.127-134
    • /
    • 2017
  • The purpose of this study was to assess the impact by comparing the concentration of indoor radon and look for ways to lower the concentration of indoor radon gas measurements of three variables, the year of completion, volume of the building and ventilation. Measurement target is six classrooms on the sixth floor of building that was constructed in 1973 and was extended in 2011. Selected classroom's volume is different. Four classrooms were selected to compare the radon concentration in accordance with the year of completion, Classrooms that is same year of completion were selected to compare the radon concentration in accordance with the volume, six classroom was performed closure and ventilation to compare radon concentration according to ventilation. Radon concentrations in accordance with the year of building completion showed a high concentration of radon in a building recently built. Also, Radon concentration in volume is high the smaller the volume. Radon concentration change according to ventilation showed a reduction of about 80% when the ventilation than during closing. Especially, The radon concentrations were high detected while the recently year of building completion and the smaller volume. Ventilation of the three variables is considered that can be expected to exposure reduction effect by radon affecting the greatest radon concentration reduction.

Estimation of soil Quantity and Environmental Effect on Dredged Soil (준설오니의 토량 산출 및 성분분석)

  • 신은철;오영인
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.2
    • /
    • pp.13-21
    • /
    • 2000
  • Detention basin is the temporary holding pond of treated water prior to flow out to the sea. It is very common to dredge the soil from the bottom of detention basin to keep up the water holding capacity. In this study, the amount of volume reduction of dredged soil from detention basin was estimated based on the laboratory test results. The percentage of soil particles in dredged organic soil is about 12.5∼21.9% by weight. The content of heavy metal and environmental effect for dredged soil itself and solidified dredged soil were analysed and the results are meet the standards of environmental requirement.

  • PDF

Study on the optimal storage-capacity based on the commodity volume in apartments - Focused on $85m^2$ apartment - (물품부피에 근거한 적정수납용적에 관한 연구 - 30평형대 아파트를 중심으로 -)

  • Lee, Youn-Jae;Kim, Joon-Ji;Lee, Hyun-Soo
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.6 s.59
    • /
    • pp.139-149
    • /
    • 2006
  • Because of economic growth and the social trend to respect individuality, people's average commodity volume tends to increase. It makes people perceive the importance of storage space. The storage planning without consideration of commodity volume in the apartment can not satisfy the needs of residents. This study is developed focused on the $85m^2$ apartment which is the most representative and general type. The objectives of the study are to investigate the storage-capacity of $85m^2$ apartment offered by 4 construction companies to know the present storage condition, to investigate the average volumes and type of commodities in 30 families located in Seoul and Kyungkido to produce the necessary storage-capacity, and lastly to produce optimal storage-capacity and proportion of optimal storage-capacity considering the volume of the furniture owned by each resident. The results of the study are 1) the storage capacity for commodity volume in $85m^2$ apartment is $19.41m^3$. 2) the optimal storage-capacity which only counts the storage volume of built-in furniture is $17.14m^3$ 3) the proportion of optimal storage-capacity is 9.5% of the house-capacity.

An Analytical Study on the Spatial Composition of Performing Arts Centers in Korea - Centering on the Analysis of Facility Capacity - (국내 공연문화시설의 공간구성분석에 관한 연구 - 시설의 용적분석을 중심으로 -)

  • Hong, Sung-Ho;Ko, Jae-Min;Lim, Che-Zinn
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.11a
    • /
    • pp.37-43
    • /
    • 2007
  • In recent years, the cultural industry is considered to a major industry in the 21 century, and performing culture is growing rapidly in Korea. Also, rapid development in terms of quality and quantity can be found in the diversification of usage, a trend focusing on the space for performance, and an emphasis on the accessibility between the stage and auditorium. In addition, active research is being conducted on the performing arts facilities, a relationship between the stage and auditorium, and a space programfor each space considering users. However, most of the current studies are conducted byviewing the facilities in a two-dimensional space. Similar to other cultural facilities, such as museums and galleries, performing arts facilities have been planned in the thinking that the ratio of capacity increases in proportion to the area. Considering a dimensional capacity in the spatial composition of performing arts facilities is important, but it has been ignored until now. Therefore, in order to analyze performing arts facilities in the three dimensional approach, this study is conducted centering on the actual capacity and provides basic data that can be used for planning a construction of future performing arts facilities.

  • PDF

Adiabatic property of plywood wall panel (합판 벽체의 단열성능)

  • 박준철;홍순일
    • Journal of Korea Foresty Energy
    • /
    • v.21 no.2
    • /
    • pp.62-68
    • /
    • 2002
  • Adiabatic property of plywood wall panel was examined to evaluate their thermal conductivities. The amount of heat loss was investigated through overall heat transmission experiment. Styroform and grass wool showed less heat loss. However, yellowsoil board and laminated lumber showed high volume specific heat capacity. When the changes of indoor and outdoor temperature were checked in model house, wall manufactured with styroform and grass wool was affected easily by the changes of outdoor temperature. Yellowsoil, the mixed board of yellowsoil and sawdust, and laminated lumber, which have high volume specific heat capacity, were not affected much. The rates of overall heat transmission were much better in styroform and grasswool, but the adiabatic properties were much higher in yellowsoil board and the mixed board of yellowsoil and sawdust. The results showed that the insulating material can be developed using yellowsoil and wood, which are nature friendly materials.

  • PDF

Effect of Foliage Plant Pachira aquatica on the Change of Indoor Temperature and Humidity (관엽식물 파키라가 실내 온·습도 변화에 미치는 영향)

  • Son, Ki-Cheol;Kim, Mi-Kyoung;Park, So-Hong;Chang, Myoung-Kap
    • Horticultural Science & Technology
    • /
    • v.16 no.3
    • /
    • pp.377-380
    • /
    • 1998
  • In order to investigate the effects of foliage plants on the changes of indoor thermal- and hygro- environments, experiments were carried out in two rooms with similar physical factors. Changes of indoor environmental parameters according to the existence of plants, their arrangement methods, and the existence of wrapseal for protecting the loss of water from the pot soil were measured during certain periods in winter and summer season, using Pachira aquatica which is widely used as indoor plant and has higher photosynthetic and traspiration rate than other foliage plants. The data suggested that the existence of plants didn't affect directly on the indoor thermal environment, while relative humidity increased about 3~5%, regardless of season, by putting plants which had volume equivalent to 2.4% of room volume. In summer, there was no difference in increasing effect of relative humidity between parallel arrangement with window and spread arrangement in the room, but in winter the former arrangement was more effective than the later.

  • PDF

A Study on planning of storage area considering residents' needs (거주자 요구를 고려한 수납면적에 관한 연구)

  • Lee, Se-Na;Lee, Hyun-Soo
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.193-196
    • /
    • 2006
  • The storage style has changed because of diversity of family types, improvement of cost of living, and increase of leisure time. In spite of this change, storage space has still caused discomfort since it did not consider residents' convenience. Therefore, in this study, Brand Apartments were selected, furniture detail drawing was analyzed by plan of housing size and zone to calculate storage area and capacity, and finally needs of storage space were analyzed using survey. Satisfaction of storage space was generally low and $20{\sim}30%$ increase of storage space was demanded. The reasons why the storage space was not satisfied are followed. First, storage space was insufficient. Second, the inner structure of storage space was unified. According to change of life style, needs have changed. To satisfy these needs, the inner division of storage space is planned with considering various items. In addition, development of hardware, flexible division, and priority of storage space with considering user's convenience are needed.

  • PDF

Effect of Scindapsus aureus and Syngonium podophyllum on the Improvement in Indoor Humidity by a Difference of Hydoroculture Volume Ratio and Pot Media (하이드로컬쳐 부피비와 화분용토에 따른 스킨답서스, 싱고늄의 실내습도 개선효과)

  • Ju, Jin-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.4
    • /
    • pp.94-99
    • /
    • 2009
  • The purpose of this study was to utilize hydroculture by the vital means of the improvement of indoor relative humidity. This experiment employed a search of the effect of Scindapsus aureus and Syngonium podophyllum that are generalized for hydroculture foliage plant by a difference of volume ratio, pot media and plants species. In the case of Scindapsus aureus, relative humidity was high for growth chamber in which plants presented as opposed to control growth chambers in which there were no plants. Although relative humidity was 25% in control chamber, there was an increase of 40% at a 2% volume ratio, 45% at a 3% volume ratio and 50% at a 5% volume ratio. The relative humidity of Syngonium podophyllum was 40% at a 2% volume ratio, 44% at a 3% volume ratio and 46% at a 5% volume ratio, while the control treatment was 25% relative humidity in hydroculture. Both the control treatment and hydroball pot in a hydroball container were high at first. As time progressed, artificial soil pots in water containers was similar when housed within the control chamber by about 45% relative humidity. Hydroball pots in water container had about 30% relative humidity. Ardisia pusilla of hydroball poIt in hydroball container had about 38% relative humidity.

Effects of Indoor Greening Method on Temperature, Relative Humidity and Particulate Matter Concentration (실내녹화 방법이 온·습도 및 미세먼지 농도에 미치는 영향)

  • Kwon, Kei-Jung;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.4
    • /
    • pp.1-10
    • /
    • 2017
  • This study investigated indoor temperature and humidity control and PM1 and PM10 mitigation effects of a single green wall (Case 1), two green walls (Case 2), and two green walls plus a waterfall (Case 3) in comparison with a control without either a green wall or waterfall. Experiments were conducted in the office of Chungbuk National University from August to September, 2015. Experiments were carried out sequentially in the order of control, Case 1, Case 2, and Case 3. Data collected from August 17 to August 20, 2015 (Experiment 1), and from August 31 to September 3, 2015 (Experiment 2), when outdoor temperature was relatively constant, were analyzed. Plant volume ratios by indoor landscaping of the control, Case 1, Case 2 and Case 3 were 0.0, 0.6, 1.2, and 1.4%, respectively. Compared to the control, average temperatures of Case 1, Case 2 and Case 3 were decreased by 0.3~0.7, 0.7~0.9 and $1.0^{\circ}C$, respectively, and relative humidity was increased by 1.8~8.7, 9.2~14.6 and 14.8~21.9%, respectively. Three hundred minutes after exposure to mosquito repellent incense particles, the ratio of the remaining PM1 of the control, Case 1, Case 2 and Case 3 were 25.0, 22.0%, 21.2%, 17.3%, respectively, in Experiment 1 and 42.3, 28.9, 23.1, and 30.9%, respectively, in Experiment 2. As indoor greening increased the effect of indoor temperature, PM1 and PM10 mitigation were greater, and temperature and humidity were lower. The greater the relative humidity was, the faster PM1 and PM10 mitigation tended to be.

Design of a shoe rack for effective sterilization and deodorization of the shoes contaminated by various bacteria (오염된 신발의 효율적인 살균과 탈취를 위한 신발장의 설계)

  • Lee, Sam-Cheol;Jang, Yong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.199-206
    • /
    • 2016
  • The aim of this study was to establish the optimal conditions to design a shoe rack that could effectively sterilize and deodorize shoes contaminated by various bacteria. The manufacture and evaluation of a shoe rock was conducted for one year from October 2014 to September 2015. The antibacterial efficacies were evaluated using Escherichia coli and Staphylococcus aureus by JIS Z 2801:2010. The deodorization efficiency was identified by the standard method for deodorization efficiency evaluation of an indoor air cleaner established by Korea Air Cleaning Association, SPS-KACA002-132:2006. The results showed that antibacterial evaluation showed more than 99.9% of the sterilization effects on Escherichia coli and Staphylococcus aureus after exposure to ultraviolet (UV) light for 30 seconds. The average deodorization efficiency for the test gases was 42.5%. The temperature in the shoes and in the shoe rack was lower than $40^{\circ}C$ and $25^{\circ}C$, respectively, when the UV lamp was turned on for 5 minutes and off for 25 minutes repeatedly. This was controlled by turning the UV lamp on and off to maintain the appropriate temperature in the shoes. In conclusion, the real deodorization efficiency is expected to be higher than the measured value because the internal volume of the shoe rack was smaller than the test chamber used to measure the deodorization efficiency. The deodorization effect could be increased further by the sterilization of bacteria causing bad odors in shoes. Further studies will be needed to determine the temperature deviations within the shoe rack to provide constant conditions.