• Title/Summary/Keyword: 실내발열

Search Result 42, Processing Time 0.023 seconds

Convergence Technique Study through Simulation Thermal Analysis due to the Shape of Electric Heater (전기 히터의 형상에 따른 시뮬레이션 열 해석 연구를 통한 융합 기술 연구)

  • Lee, Jung-Ho;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.6
    • /
    • pp.241-246
    • /
    • 2015
  • In cold winter season, the apparatuses of heating and heater which warm up the interior of a room are necessary element and the used amount of these apparatuses from the year 2000 has been increased abruptly. But, the fire accident and the danger of fire are also increased. Therefore, 3D modelling is done by referring three kinds of the electric heaters as the heaters of ceramic, carbon and near infrared ray sold in the city for the design of more safe heating apparatuses in this study. The thermal analyses with these models are carried out and the durabilities due to the thermal deformation and stress are studied. By the background of the study results derived in this study ultimately, the durabilities of electric heater models due to each shape can be anticipated and contributed to the development of new heating apparatus with more safe resistance to fire. And it is possible to be grafted onto the convergence technique at design and show the esthetic sense.

Mix Design and Physical Properties of Concrete Used in Seongdeok Multi-purpose Dam (성덕 다목적댐 콘크리트의 배합설계 및 역학적 특성)

  • Kim, Jin-Keun;Jang, Bong-Seok;Ha, Jae-Dam;Ryu, Jong-Hyun;Go, Suk-Woo;Kim, Jeong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.517-520
    • /
    • 2008
  • Gravity dam use self weight to stand external force like hydraulic pressure. In general, gravity dam concrete is divided into internal and external concrete. Seongdeok dam is gravity dam which is being constructed in Cheongsong-gun, Gyeonsangbuk-do. And upstream cofferdam was constructed to examine the temperature crack due to hydration heat and to decide the height of placement. In this study, we examined the mix design of internal/external concrete and physical properties(compressive strength, adiabatic temperature rise). And we also performed laboratory tests to verify exothermic properties. Lastly, we measured the hydration heat and thermal stress of upstream cofferdam.

  • PDF

A Study on Properties of Early Strength Development of the Concrete (콘크리트의 조기강도 발현특성에 관한 연구)

  • Kang, Chang-Woon;Lee, Jae-Sam;Kim, Jung-Sik;Sung, Yong-Hwan;Ryu, Deug-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.541-544
    • /
    • 2008
  • Recently, due to the increase of high-rise buildings construction, many researches for making harden of concrete earlier and remove of forms faster are being performed to reduce construction period. The purpose of this study is to analysis which mixing condition and curing temperature of early strength concrete. Porperties of concrete by the different factors, such as the type of active admixtures, mineral admixtures, curing temperature, the amount of binder, etc. Through the test of concrete using the different type of admixture, PC type was more excellent than PNS type admixture. The concrete Strength remarkably will be able to confirm that decreases from temperature below 12$^{\circ}C$.

  • PDF

A Study on the Heat Radiation of LED Luminaires and the Indoor Temperature Increase (LED 등기구의 발열과 실내온도 상승에 관한 연구)

  • Kim, Dong-Geon;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.9
    • /
    • pp.738-742
    • /
    • 2012
  • This paper conducted a study on how the heat radiation of light emitting diode(LED) luminaires affects the indoor temperature increase. The effect was compared with that of a 20 W compact fluorescent lamp(CFL) and a 50 W MR16 halogen lamp which are most widely used inside of cruises, a LED downlight and a 4W MR16 LED replacing each of them. We installed a luminarie inside a thermally shielded chamber, measuring the temperature changes under the same volume every 5 minutes and compared the result with theoretically calculated heat radiation. The temperature changes in the chamber was measured four times, on seven hours' period in order to keep sufficient time once the temperature reaches the thermal equilibrium state. The results showed that the temperature of the 20 W E26 CFL and the 10 W LED downlight increased by $21.1^{\circ}C$ and $10.4^{\circ}C$ respectively, while that of the 50 W halogen MR16 and the 4 W LED MR16 increased by $33.9^{\circ}C$ and $4.8^{\circ}C$ respectively. The experimental heat radiation were calculated from the results and the experimental heat radiation of the CFL and the LED downlight were 171.5 cal and 86.5 cal, and those of the halogen MR16 and the LED MR16 were 275.3 cal and 36.5 cal. Therefore, the heat radiation was reduced by 49.5% and 86.7%, respectively, by replacing conventional light source with LED. In conclusion, we can expect a reduction of power consumption in air condition system and the effect on indoor temperature increase by application of LED luminaires.

Assessment of the Models for Predicting the Thermal Conductivity of Saturated Kaolinite (포화된 카올리나이트를 이용한 열전도계수 예측모델의 신뢰성 검토)

  • Lee, Jangguen;Kim, Hakseung;Kang, Jaemo;Kim, Youngseok;Bae, Gyujin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.3
    • /
    • pp.21-27
    • /
    • 2012
  • Estimating the thermal conductivity of clayey soils is important for enhancing the performance of geoengineering structures in cold regions and clay barriers for nuclear waste repositories, but specimen disturbance, saturation, and heat boundary conditions of the test apparatus hinder reliable measurements of the thermal conductivity of saturated clayey soils. This paper presents the results of an experimental study carried out using modified consolidation tests with the needle probe method to measure thermal conductivity. Experimental consolidation tests with saturated kaolinite were performed to investigate the effect of effective stress and dry density on thermal conductivity for saturated kaolinite. In addition, thermal conductivity of soil particles were thoroughly investigated and experimental results were used to evaluate the accuracy of the models to predict thermal conductivity.

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.

Evaluation of the Deicing Performance and Concrete Structure Effect with Various Deicing Chemicals (제설제 종류에 따른 융빙성능 및 콘크리트에 미치는 영향 평가에 관한 연구)

  • Lee, Byung-Duck;Yun, Byung-Sung;Lee, Joo-Kwang;Chung, Young-Hwan
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.113-123
    • /
    • 2005
  • In this study, calcium chloride$(CaCl_2)$, sodium chloride (NaCl), organic acids-containing deicer(NS 40, NS 100), mixed deicier$(NaCl\;70%+CaCl_2\;30%,\;NS\;40\;70%+CaCl_2\;30%,\;NaCl\;70%+NS\;40\;30%,\;NS\;40\;70%+NaCl\;30%)$ is investigated based on the laboratory test for deicing performance, freez-thaw resistance of concrete, and corrosion rate of metal. Test items for deicing performance were ice melting and ice penetration, freezing point depressions and eutectic point, pH, thermal properties for selected deicing chemicals as well as their compatibility with concrete and metal were experimentally investigated. As a test results, in case of the use chloride-containing deicier in area that concrete structures has subjected to freez-thaw reaction in winter season, it showed that mixed deicing chemicals with optimum ratio has desirable method than use one deicing chemicals when is consider to deicing performance and effects, corrosion of steel materials, and freez-thaw resistance of concrete. When use various deicing chemicals mixed, NS40(70%)+calcium chloride(30%) showed the best effective method.

  • PDF

Estimation of Forest Biomass in Korea (우리나라 산림 바이오매스 추정)

  • Son, Yeong Mo;Lee, Kyeong Hak;Kim, Rae Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.4
    • /
    • pp.477-482
    • /
    • 2007
  • Forest biomass became a topic because we have growing interest in global environmental issues and environment-friendly energy resources. This study was carried out to estimate the forest biomass and develop a program for biomass information management in Korea. The total forest biomass (million ton) were 521 for gross forest, 403 for productive forest and 201 for commercial forest in 2005. Also, the annual biomass production in forest was 20 million ton which was equivalent to 94,290 Gkcal of heating value and about 9 billion won of paraffin oil. The biomass growing rate (every 10year) increased from 4.95% in 1985 to 5.30% in 1995 but turn down 4.46% in 2005. The factors that the forest stock could be converted to the forest biomass have developed according to forest type. Therefore, it is impossible to estimate the exact biomass by tree species. In this reason, the demands of the development of the factors by tree species was raised. In addition, it is on time to develop an equation for estimation of biomass by species using dbh and height as independent factors.

Early Frost Damage and Diagnose of Damage Depth Due to Early Frost Damage of the Concrete According to the Thickness of Members (부재 두께 변화에 따른 콘크리트의 초기동해 특성 분석 및 깊이진단)

  • Kim, Tae-Woo;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.2
    • /
    • pp.131-138
    • /
    • 2019
  • Recently, there are many structures exposed to severe outdoor environments, which results in rapid degradation of durability of the concrete structures. there can be rapid deterioration of the concrete structures from early frost damage due to the insufficient curing in low outdoor temperature condition. The objective of this study is to investigate the effect of thickness change conditions and binding material on early frost damage depth of the concrete exposed to cold weather in winter, and is to clearly assess damage depth of the concrete structure due to early frost damage. Specimens with 300x300x(150, 200, 250, 300mm) were prepared. OPC and OPC+FA+BS were adopted for binders. Test results indicate that the depth of the early frost damage was deeper with the decrease of thickness of members. The brightness of specimens were reduced when the member thickness was thinner. When determining the depth of early frost damage, it can be distinguished into dark color and relatively bright color when dried for approximately 30 minutes in the indoors of $20^{\circ}C$ in temperature and 60% in relative humidity after submerging in water for 24 hours. The dark colored part can be determined easily when measured with vernier calipers.

A Study on the Design and Implementation of a Thermal Imaging Temperature Screening System for Monitoring the Risk of Infectious Diseases in Enclosed Indoor Spaces (밀폐공간 내 감염병 위험도 모니터링을 위한 열화상 온도 스크리닝 시스템 설계 및 구현에 대한 연구)

  • Jae-Young, Jung;You-Jin, Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.2
    • /
    • pp.85-92
    • /
    • 2023
  • Respiratory infections such as COVID-19 mainly occur within enclosed spaces. The presence or absence of abnormal symptoms of respiratory infectious diseases is judged through initial symptoms such as fever, cough, sneezing and difficulty breathing, and constant monitoring of these early symptoms is required. In this paper, image matching correction was performed for the RGB camera module and the thermal imaging camera module, and the temperature of the thermal imaging camera module for the measurement environment was calibrated using a blackbody. To detection the target recommended by the standard, a deep learning-based object recognition algorithm and the inner canthus recognition model were developed, and the model accuracy was derived by applying a dataset of 100 experimenters. Also, the error according to the measured distance was corrected through the object distance measurement using the Lidar module and the linear regression correction module. To measure the performance of the proposed model, an experimental environment consisting of a motor stage, an infrared thermography temperature screening system and a blackbody was established, and the error accuracy within 0.28℃ was shown as a result of temperature measurement according to a variable distance between 1m and 3.5 m.