• Title/Summary/Keyword: 실내미세먼지

Search Result 156, Processing Time 0.037 seconds

A Study on the Smart Filter System for External Environment Recognition (외부환경 인식용 스마트 필터 시스템에 대한 연구)

  • Seo, Do-Won;Yoon, Keun-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.2
    • /
    • pp.271-278
    • /
    • 2021
  • This paper is a study on the implementation of smart filter system that recognizes the external environment and automatically removes pollutants according to pollution level. Recently, the occurrence of various pollutants in indoor and outdoor space has adversely affected the human body. Especially, various fine dust generated in the atmosphere becomes worse in closed residential space or office space. Although air pollution can be temporary lowered through ventilation, it is difficult to respond to fine dust changes in real time, and such problems become serious in the space where many people reside, such as at home or industry. Therefore, it is necessary to measure the pollution level of fine dust inside the residential space in real time and to reduce the pollution of indoor ventilation through automatic ventilation with the outside. To improve these problems, this paper proposes the implementation of smart filter system for external environment recognition. The structure of smart filter system that automatically measures air quality inside and outside, removes pollutants, implements the function, and confirms the operability by manufacturing prototypes. Finally, the effectiveness of the smart filter system for solving fine dust problems was examined.

A Smart city study trough development of new risk index based on GAM model and activity recommendation system for the vulnerable class of fine dust (GAM모델 기반의 미세먼지 취약계층 대상 새로운 위험지수 개발 및 활동 추천시스템을 통한 생활밀착형 스마트시티 연구)

  • Kwon, Jae-Sun;Kim, Ji-Yeon;Yu, Hyun-Su;Choi, Ji-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.1009-1011
    • /
    • 2022
  • 최근 미세먼지는 중대한 건강위험요소로 고려되고 있고, 미세먼지 취약계층은 이에 대한 적극적 대응이 필요하다. 그러나 현재의 대기환경지수는 세분화 되어있지 않아 본 논문에서는 위해성 평가와 GAM 모형을 기반으로 건강취약계층 대상을 위한 미세먼지 위험지수를 새롭게 개발하였다. 또한, 이에 따라 실내 및 실외활동을 추천하는 시스템을 구현함으로써 생활밀착형 스마트시티로 발돋움하도록 한다.

A Classification Model for Distinguishing the Types of Fine-dust (미세먼지 종류의 구분이 가능한 분류모델)

  • Minhye Jeon;Seokho Ahn;Young-Duk Seo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.05a
    • /
    • pp.90-91
    • /
    • 2023
  • 대기오염에 대한 사회적 관심이 증가함에 따라 미세먼지 관련 IoT 가전제품의 수요가 증가하였다. 이에 따라 IoT 제품에서 수집되는 실내 데이터의 정확성을 높이기 위해 미세먼지 센서 외의 추가적인 센서를 사용하여 관측치를 예측하는 연구가 진행되고 있다. 하지만 기존 연구에서는 센서의 물리적 한계를 인공지능을 통하여 극복하려는 시도는 존재하지 않는다. 본 논문에서는 추가적인 센서를 사용하지 않고 단일 센서만을 사용하여 미세먼지 종류의 구분 가능성을 판단하고자 하며 이를 정확도 기반으로 비교 실험을 진행하여 가장 좋은 성능을 나타낸 딥러닝 기반 분류모델을 선정한다.

Technology Trends of Indoor Air quality for Public transportation (대중교통 실내공기질 기술 동향)

  • Park, Mijeong;Choi, Jinsik;Park, Byung Hyun
    • Prospectives of Industrial Chemistry
    • /
    • v.23 no.4
    • /
    • pp.13-19
    • /
    • 2020
  • 수년간 고농도 미세먼지 발생으로 인한 실내공기질 관리방안에 관한 논의가 계속되고 있다. 특히, 시민들이 하루에 1.75시간 이상 지하철 및 버스 등의 대중교통 내에서 머물고 있는 것으로 발표되고 있어 환경부에서는 2019년 대중교통에서의 공기질 관리 방안을 강화하는 것으로 발표한 바 있다. 최근 철도차량 등의 대중교통 차량에서 공기질 개선장치가 도입되고 있는 추세이긴 하나, 대부분의 기존 대중교통차량에서는 공기질 개선장치가 적용되어 있지 않고 대기질이 나쁨인 경우 실내 환기가 어려워 이용 시민들의 건강을 해칠 수 있는 상황이다. 이러한 상황에서 강화되는 실내공기질관리법을 만족하기 위해서는 다양한 대중교통 차량에서의 공기질 관리기술을 토대로 신규차량 뿐만 아니라 기존차량에서 적용할 수 있는 실제적인 논의가 필요하다. 본 기고문에서는 대중교통에서의 공기질 현황을 알아보고 효율적인 공기질개선을 위한 미세먼지 및 이산화탄소 저감에 관한 연구동향을 정리하고자 한다.

Indoor Air Quality in daycare facilities (보육시설의 실내공기질 유지관리 실태)

  • Park, Jun-Seok
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.6
    • /
    • pp.28-32
    • /
    • 2014
  • 본 투고에서는 2008년 환경부의 용역으로 실시된 "보육시설의 실내공기질 진단 및 개선 시범사업"의 결과를 바탕으로 우리나라 보육시설의 실내공기 오염 실태와 함께 개선방안, 그리고 개선효과에 대하여 소개하였다. 서울, 경기, 인천 지역의 61개 시설을 대상으로 실내공기질 측정과 설문조사를 실시한 결과 폼알데하이드와 총 휘발성유기화합물은 일부시설에서 "다중이용시설 등의 실내공기질 관리법" 기준치를 초과하는 것으로 나타났다. 반면 이산화탄소와 미세먼지는 조사 대상 시설 중 50 % 이상이 기준치를 초과하는 것으로 나타났다. 따라서 보육시설의 실내공기질 개선을 위해서는 각 오염물질의 발생원별로 유지관리 대책이 필요한 것으로 조사되었다. 또한 오염원인별 분석결과, 대부분 시설의 실외오염물질 농도가 실내보다 낮게 나타나 외기의 오염이 실내에 미치는 영향은 미비한 것으로 나타났으며, 계절에 따른 실내공기오염은 동절기에 낮은 외기온도로 인하여 실내를 하기 때문에 하절기에 비해 더 높게 나타났다. 공간에 따른 오염물질의 농도는 이산화탄소와 미세먼지의 경우 아동이 늘 상주하는 교실의 오염이 가장 심한 것으로 나타났으며 폼알데하이드와 총휘발성유기화합물의 경우 놀이실의 오염도가 교실에 비해 더 높게 나타났다. 개선방안별 개선효과에 있어서는 환기계획 몇 환기설비 설치, 지하공간 습기 문제 개선에서 가장 높은 효과가 나타났다. 향후 보육시설의 쾌적하고 건겅한 실내환경의 유지관리를 위해서는 보육종사자들이 활용할 수 있는 유지관리 지침 또는 매누얼에 대한 보급이 필요할 것으로 판단된다.

Stabilization of Soil Moisture and Improvement of Indoor Air Quality by a Plant-Biofilter Integration System (식물-바이오필터에 의한 토양수분 안정화 및 실내 공기질 향상)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.751-762
    • /
    • 2015
  • This study was performed to investigate the stability of soil moisture in controlling air ventilation rate within a horizontal biofilter, and to compare removal efficiency (RE) of indoor air pollutants including fine dust, volatile organic compounds (VOCs), and formaldehyde (HCHO), depending on whether dieffenbachias (Diffenbachia amoena) were planted in the biofilter. The relative humidity, air temperature, and soil moisture contents showed stable values, regardless of the presence of D. amoena, and the plants grew normally in the biofilter. REs for number of fine dust particles (PM10 and PM2.5) within the biofilter filled with only soil were at least 30% and 2%, respectively. REs for number of fine dust particles (PM10 and PM2.5) within the biofilter including the plants were above 40% and 4%, respectively. RE for fine dust (PM10) weight was above 4% and 20%, respectively, in the biofilter containing only soil or soil together with plants. In the case of the biofilter filled with only soil, REs for xylene, ethylbenzene, toluene or total VOC (T-VOC) were each more than 63%; however, REs for benzene and formaldehyde (HCHO) were above 22% and 38%, respectively. In the biofilter with the plants, REs for xylene, ethylbenzene, toluene, and T-VOC were each above 72%, and REs for benzene and HCHO were above 39%. Thus, RE of the biofilter integrated with plants was found to be higher for volatile organic compounds than for fine dust. Hence, the biofilter was very effective for indoor air quality improvement and the effect was higher when integrated with plants.

Fine Dust Suppression by Enzyme Induced Carbonate Precipitation: Indoor Experiment and Field Application (EICP에 의한 미세먼지 억제: 실내 실험 및 현장 적용)

  • Song, Jun Young;Ha, Seong Jun;Sim, Youngjong;Jin, Kyu-Nam;Yun, Tae Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.10
    • /
    • pp.67-78
    • /
    • 2019
  • The efficiency of suppressing fine dust was evaluated by conducting indoor and field experiments for the ground treated with EICP solution, which is an eco-friendly ground improvement method. In laboratory experiments, the EICP solution was prepared with inexpensive materials for the field applicability, and the optimal mixing ratio and optimal spraying volume of EICP solution were calculated. The optimum amount of calcium carbonate was shown when the ratio of urea/calcium chloride and white powder were 1.5 and 15 g/L, respectively. The optimum spraying amount of the EICP solution was $7L/m^2$ determined by fine dust suppression and cone tip resistance experiments. The spraying of water and EICP solution was conducted at the test-bed where dump trucks pass for the effect of suppressing fine dust of each method. The effective fine dust suppression method can be chosen depending on the situation of the site.

A Study on the Design of Planterior to Reduce and Purify Indoor Particle Matters (PM) (실내 미세먼지 저감을 위한 플랜테리어 디자인 연구)

  • Ahn, SeungWon;Jeong, Jun Hyun
    • Journal of the Korean Society of Floral Art and Design
    • /
    • no.44
    • /
    • pp.3-31
    • /
    • 2021
  • To verify the types of effects that plants have in our general living conditions, I examined an air quality in living rooms of the three, 129.78m2 size, apartments that were with and without plants. and the findings of the study were as addressed below. 1) Experiments showed no statistically significant differences in Case A. However, in Case B and Case C, the standard deviation of PM10, PM2.5 and PM 1.0 verified that each had statistically significant (p<.01) differences. 2) It is believed that the effect of reducing particle matters due to the installation of plants in the indoor space is to vary significantly depending on the indoor environmental conditions, the cleanliness of the room, and the amount of furniture and may also differ depending on the daily dietary cooking method. In addition, it is believed that the planterior will not only reduce indoor fine dust, but also reduce the psychological comfort and eye fatigue of the residents. Nevertheless, supplementary research is needed. 3) In the planterior design for reducing indoor particle matters, various measures were examined. Among them, the vertical wall design method was tested and suggested through empirical experiments. In addition, maintenance methods were proposed depending on the type of indoor plant.

Iot based Indoor Air Quality Monitoring System (Iot 기반 실내 공기오염 측정 시스템)

  • Kim, Ungtae;Kim, Yong-Chul;Kwak, Sooyeong
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.143-151
    • /
    • 2016
  • Many people interested in indoor air quality monitoring since they spend a majority of their time indoors such as homes and offices. This paper proposes the effective indoor air quality monitoring system and it can gauge carbon dioxide, particulate matter and VOCs(Volatile Organic Compounds) which can be harmful to humans. The proposed system is composed of three main modules which are device, web server, and mobile application. In order to evaluate the performance, we tested two cases which are candle and smoke. We monitor the condition of indoor air quality with our mobile application. Also, we developed the information graphics to compare the condition of air quality between indoor and outdoor and this mobile application improves usability.

Implementation of Particle Measuring Sensor System Using Laser Optical Scattering Method (레이저 광산란식 미세먼지 측정 시스템의 실현)

  • Kim, Gyu-Sik;Na, Hyeong-Uk;Kang, Sang-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.365-366
    • /
    • 2008
  • 광학입자 계수기는 실내환경, 대기오염 및 콜린룸 등 입자크기분포 측정장비로 가장 많이 사용된다. 광학입자 계수기에 샘플링된 업자는 관측체적 내로 1개씩 통과 하며 산란된 빚은 집광장치에 의해 광검출기로 전달한다. 이때 산란광의 양에 비례하여 전압 (전류)의 세기로 변환하여 전기적 선호로서 나타나는 Pulse의 높이는 Calibration Data에 따라 업자의 크기로 변환하고 Pulse의 개수는 입자의 개수로 표시된다. 입자의 크기와 개수등 이용하여 부피로 환산 한 후 부유하는 입자의 평균 밀드를 이용하여 질량으로 환산시킨다. 이렇게 측정된 미세먼지 농도는 ZigBee 통신을 사용하여 구축한 시스템을 통해서 중앙부에서 실시간으로 먼지 농도를 알 수 있다. 특히 멀티흡 기능을 이용하여 건물 구조가 복잡하거나 층간의 통신, 꺾인 부분이나 사무실 안과 밖과 같은 무선 통신이 원할 하지 못하는 경우를 극복하여 미세먼지의 농도 값을 측정 할 수도 있다.

  • PDF