• Title/Summary/Keyword: 실내공기환경 평가

Search Result 137, Processing Time 0.027 seconds

Treatability Study on the Remediation Groundwater Contaminated by TPH Cr6+ : Lab-Scale Experiment (TPH와 6가 크롬으로 오염된 지하수 처리를 위한 실내 실험)

  • Lee, Gyu-Beom;Chang, Yoon-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.332-345
    • /
    • 2019
  • The purpose of the study is to evaluate the treatability of contaminated groundwater with TPH and (or) $Cr^{6+}$. Laboratory scale tests were performed for oil/water separation, dissolved air flotation (DAF), coagulation and precipitation, and filtration with sand and activated carbon respectively. Two times of oil/water separation tests for total 40 minutes of separation or separating time shows 90.2 % of TPH removal rate. In case of DAF test for high TPH sample, the TPH removal rates were not varied significantly by the variation of microbubble size. However, tests for low TPH samples show that TPH removal rate increases as microbubbles are smaller. When coagulant was added to sample for DAF test, TPH removal rate was increased 12.3 %. SS removal rate by DAF was 97.9 % at $16-40{\mu}m$ and it was increased as the size of microbubble is reduced. Tests for coagulation and precipitation were performed to evaluate the removal of $Cr^{6+}$ in groundwater. The increase of $FeSO_4$ dosage increased $Cr^{6+}$ removal rate in the coagulation and precipitation process. As the amount of activated carbon in the filter media increased TPH removal rate in the filtration process. SS removal rate by the filtration was 96.7 % similar to the results of DAF process tests. The filtration process treats TPH and SS. Best design parameters are determined as the size of sand is $425-850{\mu}m$ and the ratio of activated carbon and sand is 50:50.

The Evaluation and Investigation of Conscious Cognition Degree on a room-size air cleaner (실내용 공기청정기의 성능평가 및 인식도 조사)

  • 손종렬;김영환;우완기
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.115-120
    • /
    • 2002
  • This study was performed on a questionnaire survey of 500 people about their awareness for indoor air pollution, and measured efficiency of air cleaner which can remove the CO and air-borne particulate of ETS(Environmental Tobacco Smoke) in air clean chamber. The room-size cleaner for measuring indoor air contaminants has been applied to evaluation of two different air cleaner such as the mechanic air cleaner with hepafilter(HPA) and the electrostatic air cleaner with metal plate. The measuring experiment was carried out in a chamber by sampling the air. The results obtained were as follows; As respondents are having their 90% of daytime indoors a day, and 38% of them can feel indoor air pollutions degrees directly by their sense of smell, For the installation of indoor pollution control equipment, 34% of all respondents installed air cleaner because of the problem of economical charge and almost respondents was not satisfied the trust of ability purified indoor air pollutants. In the experimental results, it was found that more than 95% of CD and air-borne particulate of ETS were removed within 20 minutes. The reaction kinetics of removal pollutants was verified as the pseudo-first order, Finally, it appeared that the room-sire air cleaner can be applied to new technology for removing indoor air contaminants.

Evaluation of Ventilation System Performance Using Indoor Air Quality Model (실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가)

  • 최성우
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

Using multi-sensor for Development of Multiple Occupants' Activities Classification Model Based on LSTM (다중센서를 활용한 LSTM 기반 재실자 행동 분류 모델 개발)

  • Jin Su Park;Chul Seung Yang;Kyung-Ho Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.1065-1071
    • /
    • 2023
  • In this paper discuss with research developing an LSTM model for classifying the behavior of occupants within a residence. The multi-sensor consists of an IAQ (Indoor Air Quality) sensor that measures indoor air quality, a UWB radar that tracks occupancy detection and location, and a Piezo sensor to measure occupants' biometric information, and collects occupant behavior data such as going out, staying, cooking, cleaning, exercise, and sleep by constructed an experimental environment similar to the actual residential environment. After the data with removed outliers and missing, the LSTM model is used to calculate accuracy, sensitivity, specificity of the occupant behavior classification model, T1 score.

The TVOC management level evaluation of adhesive product following to simultaneous revision of indoor air quality testing methods and standards (실내공기질 공정시험방법과 기준의 동시 개정에 따른 접착제 제품의 TVOC 관리수준 평가)

  • Yoo, Ji-Ho;Park, Joon-Man;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.255-260
    • /
    • 2010
  • The Ministry of Environment simultaneously revised testing methods and emission standards of adhesives product on the "Law of indoor air quality management" for the effective management of the building materials releasing pollutants in great quantities. Accordingly, it is impossible to compare original standards with revised standards directly. The influences of each factor of the revised testing methods of adhesive product on the emission rate of pollutants are reviewed through comparing with the original testing method. Through this study, revised pollutant emission control standards were assessed. With the result that it is found that emission rate of adhesives product is weakened two and half times by changing test period and the emission rate resulting from changing drying time has little difference. As a result of comparing TVOC emission standards with the original testing method considering the modification of testing methods, it is found that the emission standard through this revision is strengthened about 2.1 times more than that of present testing method.

Evaluation of TVOC regulation level of sealant products in accordance with simultaneous revision of testing method and regulation value in the law of indoor air quality management (실내 공기질 공정시험방법과 기준의 동시 개정에 따른 실란트 제품의 TVOC 관리수준 평가)

  • Yoo, Ji-Ho;Park, Joon-Man;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.138-146
    • /
    • 2010
  • The Korean Ministry of the Environment revised a few sections of the regulations in the Law of indoor air quality management for the reinforcement or adjustment of the regulation criteria standard for releasing pollutants from building materials. Especially, in case of sealant, the contents covering liquid building materials, excess standards and testing methods have been added simultaneously in this revision, As a result it is impossible to compare original standards with revised standards directly. For this reason, this study reviewed revised test method of sealant pollutant emission rates in terms of impact and validity in comparison with the original test method. Through this study, the basic properties of revised pollutant emission control standards was assessed. Especially in sealant, since each product has a wide deviation of time required for complete drying, it is proved that there are a large number of products that are not hardened completely in test time. The result of our experiments on the revised test methods showed that this revised test methods yield emission rates that are two and half times less than those of the original testing method. To apply the revised test method of sealant to all the sealant products, It is necessary to extend the test period or improve specimen to fit the test method for quickly drying sealant products.

Field Application of a Precast Concrete-panel Retaining Wall Adhered to In-situ Ground (원지반 부착식 판넬옹벽의 현장 적용성 평가)

  • Min, Kyoung-Nam;Lee, Jae-Won;Lee, Jung-Gwan;Kang, In-Kyu;Ahn, Tae-Bong
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.51-61
    • /
    • 2016
  • New building methods are needed to aid increased inner-city redevelopment and industrial construction. A particular area of improvement is the efficient use of cut slopes, with the minimization of associated problems. A retaining wall of precast panels can resist the horizontal earth pressure by increasing the shear strength of the ground and reinforcing it through contact with the panels. Precast panels allow quick construction and avoid the problem of concrete deterioration. Other problems to be solved include the digging of borrow pits, the disposal of material cut from the slope, and degradation of the landscape caused by the exposed concrete retaining wall.This study suggest the methods of improvement of an existing precast panel wall system by changing the appearance of the panels to that of natural rock and improving the process of adhering the panel to a vertical slope. The panels were tested in the laboratory and in the field. The laboratory test verified their specific strength and behavior, and the field test assessed the panels' ground adherence at a vertical cutting. Reinforcement of the cutting slope was also measured and compared with the results of 3D numerical analysis. The results of laboratory test, identified that the shear bar increase the punching resistance of panel. And as a results of test construction, identified the construct ability and field applicability of the panel wall system adhered to in-situ ground. In addition to that, extended measurement and numerical analysis, identified the long-term stability of panel wall system adhered to in-situ ground.

A Study on the Elements of Interior Design in Victorian Style (빅토리안 스타일 주택 실내 디자인에 관한 연구)

  • Kim, Jung-Keun
    • Archives of design research
    • /
    • v.18 no.4 s.62
    • /
    • pp.25-34
    • /
    • 2005
  • The purpose of the present study is to investigate the characteristics of the current Victorian-style interior by reviewing the basic Victorian-style house in the past. this research was analyzed various prior studies and literatures, and found the following results: First, the Victorian-style house and interior space showed various historical trends and adopted every style from Gothic to rococo, and sometimes more than one style influenced a single place. Its formality was applied depending on the function and standard of each room. Second, the interior had many decorative things with free, irregular or other patterns, influenced by Romanticism and Naturalism. The several environmental factors such as air pollution and hygienic matter were also related with its trend. the dramatic changes in the kitchen and sanitary facilities were appeared based on the technical development, and affluent design styles were also used. All these reflected the characteristics of the Victorian age. In conclusion, the characteristics of Victorian-style were influenced by many factors including: (a) the trend of Romanticism and Naturalism, (b) consideration of family convenience based on the technical development, (c) the Socio-Environmental factors like air pollution and the social norm, and (d) reflection of the individual value in accordance with frequent contacts with foreign cultures. In this respect, it is necessary to reevaluate the Victorian-style after paying due regard to such factors.

  • PDF

Estimation of Indoor Environment using CFD of Multi-Purpose System with a Solar Collector -Part 1, focused on floor area and number of ventilation- (태양열온수기 적용 냉난방시스템의 CFD를 이용한 실내환경 평가 -제1보 바닥면적과 환기횟수를 중심으로-)

  • Kim, Jong-Ryeol;Choi, Kyang-Hyan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.55-61
    • /
    • 2007
  • This paper has been conducted to estimate cooling capacity of the dehumidification tower using hot water from a solar water heating system as a energy source of regeneration process when the dehumidification and drying system is applied to room cooling. A solar water heating system was operated and indoor temperature distributions were simulated according to weather conditions when the concerned solution was used to dehumidify room air in the dehumidification tower. Through this simulation researches we found th following results ; It was found that air velocity through supply and return diffusers should be controlled because it can cause uncomfort in dwelling area. It was found that in the sunny morning temperatures of dwelling area 1 and 2 are higher than those of dwelling area 3 and 4. In this research all the calculation results of heating and cooling system supported by solar water heater have confirmed that its cooling capacity could not reach PMV 0, thermal comfort.

Evaluation of Comfortableness in Railroad Electric Rolling Stock - Focused on Temperature and Humidity - (철도 전동차내의 쾌적성 평가에 관한 연구 - 온도 및 습도를 중심으로 -)

  • 박덕신;배상호;정병철;이주열
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.1
    • /
    • pp.41-48
    • /
    • 2003
  • Most of people spends their times in indoor about 85% of a day. Thus, indoor is more serious than outdoor concerned with the health. We discussed comfortableness in a railroad electric rolling stock, and focused on temperature and humidity. Electric rolling stock is one of major public transportation system because of an increasing in population and heavy traffic problems. The passengers are under the influence of indoor air quality such as air temperature, relative humidity and air velocity. Ventilation system in electric rolling stock should be designed for the health and comfort. One of the main aims is to create an acceptable thermal environment without draught problem. The draught sensation increases when the air temperature decreases and the air velocity increases. Airflow in electric rolling stork is turbulent. Temperature and humidity gradients in electric rolling stock have been studied. And, the difference between mean temperature and rotative humidity measured at 0.7, 0.9, 1.2, 1.7m above the floor. It has been found that temperature and relative humidity with large fluctuations caused more draught complaints.