• Title/Summary/Keyword: 신호추출

Search Result 2,066, Processing Time 0.031 seconds

Simultaneous Analysis of Stimulants and Narcotic Analgesics by Capillary Column Gas Chromatography with Nitrogen Phosphorus Detector (Capillary Column Gas Chromatography/Nitrogen Phosphorus Detector를 이용한 흥분제 및 마약성 진통제의 동시분석에 관한 연구)

  • Lho, Dong-Seok;Shin, Ho-Sang;Kang, Bo-Kyung;Paek, Heang-Kee;Kim, Seung-Ki;Lee, Jeong-Ae;Kim, Young-Lim;Park, Jong-Sei
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.659-666
    • /
    • 1991
  • A systematic analysis of 18 stimulants and narcotic analgesics containing nitrogen atom (s) in human urine by gas chromatography with nitrogen phosphorus detector (GC-NPD), is described. The urinary extract with diethyl ether at pH 8.5 showed good recoveries of the drugs and less interference peaks on GC chromatogram. Retention data were standardized by the calculation of relative retention times using diphenylamine as the internal standard. The relative standard deviations of retention times were less than 0.1% for the within-run analyses. The response factor (RRF) of a drug relative to the internal standard was calculated. RRF decreased with increasing number of nitrogen atoms. This technique can be adapted to various analytical toxicology problems.

  • PDF

Two-step Boundary Extraction Algorithm with Model (모델 정보를 이용한 2단계 윤곽선 추출 기법)

  • Choe, Hae-Cheol;Lee, Jin-Seong;Jo, Ju-Hyeon;Sin, Ho-Cheol;Kim, Seung-Dae
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • We propose an algorithm for extracting the boundary of a desired object with shape information obtained from sample images. Considering global shape obtained from sample images and edge orientation as well as edge magnitude, the Proposed method composed of two steps finds the boundary of an object. The first step is the approximate segmentation that extracts a rough boundary with a probability map and an edge map. And the second step is the detailed segmentation for finding more accurate boundary based on the SEEL (seed-point extraction and edge linking) algorithm. The experiment results using IR images show robustness to low-quality image and better performance than conventional segmentation methods.

A Continuous-time Equalizer adopting a Clock Loss Tracking Technique for Digital Display Interface(DDI) (클록 손실 측정 기법을 이용한 DDI용 연속 시간 이퀄라이저)

  • Kim, Kyu-Young;Kim, Gil-Su;Shon, Kwan-Su;Kim, Soo-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.2
    • /
    • pp.28-33
    • /
    • 2008
  • This paper presents a continuous-time equalizer adopting a clock loss tracking technique for digital display interface. This technique uses bottom hold circuit to detect the incoming clock loss. The generated loss signal is directly fed to equalizer filters, building adaptive feed-forward loops which contribute the stability of the system. The design was done in $0.18{\mu}m$ CMOS technology. Experimental results summarize that eye-width of minimum 0.7UI is achieved until -33dB channel loss at 1.65Gbps. The average power consumption of the equalizer is a maximum 10mW, a very low value in comparison to those of previous researches, and the effective area is $0.127mm^2$.

The implementation of modular respiratory system for patient monitoring (환자감시를 위한 모듈형 호흡 시스템의 구현)

  • 박종억;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.503-506
    • /
    • 2001
  • There are four factors for patient monitoring : electrocardiography, blood pressure, temperature and respiration. While there are a lot of studies of E.C.C (electro-cardiography) monitoring system in the world, the studies of Respiratory system are not enough and leave much to be desired in the country. In this paper, we developed a respiratory system with the electrical impedance change of the lungs depending on the breath. Using the same electrode, we can monitor E.C.C and Respiration simultaneously, so we can monitor a patient's no-breathing state due to the central nerve paralysis in the emergency room easily. In this monitoring system, the analog part was made separated from the digital part for reducing power source noise and protecting patient from electric shock. The analog part consists of the several parts a high-frequency sine-wave generator, all amplifier for amplifying any impedance change signal, an analog processing part for rectifying and filtering. And the digital parts consists of three parts an AD convertor for converting analog signal to digital signal, digital filter, and a digital part for digital signal processing. This system's merits are using the same electrode with E.C.C and developing the multiple patient monitoring system easily.

  • PDF

Effect of Trametes cubensis Extract on Vascular Function of Bovine Aortic Endothelial Cells (Trametes cubensis 버섯 추출물이 소의 대동맥 내피세포의 혈관 기능에 미치는 효능)

  • Jang, Sujeong;Lee, Dong Hyeung;Kim, Seong Hwan;Park, Heonyong
    • The Korean Journal of Mycology
    • /
    • v.48 no.1
    • /
    • pp.1-13
    • /
    • 2020
  • Mushrooms have been extensively used as traditional medicines to treat cancer and inflammatory diseases. In this study, we examined whether Trametes cubensis extract (TCE) exerted beneficial effects on cardiovascular function. First, we demonstrated that TCE was non-cytotoxic and enhanced cell proliferation of bovine aortic endothelial cells (BAEC). Moreover, TCE induced cell migration and blocked lipopolysaccharide-induced adhesion of monocytes to BAEC. We performed a variety of cell signaling studies, showing that TCE activates p38 MAPK and generates reactive oxygen species (ROS). Our results showed that TCE-induced vascular functions were mediated by p38 MAPK, but not by ROS. These results provide insights into bio-medical applications of TCE as a preventive or therapeutic agent for treating cardiovascular diseases including atherosclerosis.

A Study on Efficient Feature-Vector Extraction for Content-Based Image Retrieval System (내용 기반 영상 검색 시스템을 위한 효율적인 특징 벡터 추출에 관한 연구)

  • Yoo Gi-Hyoung;Kwak Hoon-Sung
    • The KIPS Transactions:PartB
    • /
    • v.13B no.3 s.106
    • /
    • pp.309-314
    • /
    • 2006
  • Recently, multimedia DBMS is appeared to be the core technology of the information society to store, manage and retrieve multimedia data efficiently. In this paper, we propose a new method for content based-retrieval system using wavelet transform, energy value to extract automatically feature vector from image data, and suggest an effective retrieval technique through this method. Wavelet transform is widely used in image compression and digital signal analysis, and its coefficient values reflect image feature very well. The correlation in wavelet domain between query image data and the stored data in database is used to calculate similarity. In order to assess the image retrieval performance, a set of hundreds images are run. The method using standard derivation and mean value used for feature vector extraction are compared with that of our method based on energy value. For the simulation results, our energy value method was more effective than the one using standard derivation and mean value.

Market Microstructure Noise and Optimal Sampling Frequencies for the Realized Variances of Stock Prices of Four Leading Korean Companies (한국주요상장사 주가 실현변동성 추정시 시장미시구조 잡음과 최적 추출 빈도수)

  • Oh, Rosy;Shin, Dong-Wan
    • The Korean Journal of Applied Statistics
    • /
    • v.25 no.1
    • /
    • pp.15-27
    • /
    • 2012
  • We have studied the realized variance(RV) of intra-day returns and market microstructure noise based on high-frequency stock transaction data for the four largest companies in terms of market capitalization in the KOSPI. First, non-negligible biases are observed for the RV and for the bias-corrected realized variance($RV_{AC_1}$) which is constructed by adjusting RV for the first order autocorrelation in intra-day returns. Bias is more obvious for the RV and the $RV_{AC_1}$ when intra-day returns are sampled more frequently than every 2 minutes. Transaction Time Sampling(TTS) is shown to be better than Calendar Time Sampling(CTS) in terms of biases of the RV and the $RV_{AC_1}$ for the 4 companies. The analysis reveals that market microstructure noise is temporally dependent. Second, by using the Noise-to-Signal Ratio(NSR), we estimate sampling frequencies that are optimal in terms of the Mean Square Errors(MSE) of the RV and the $RV_{AC_1}$. The optimal sampling frequencies are around 200 for RV and is around 5000 for the $RV_{AC_1}$ for all the four stock prices. For the 6 hour transaction period of the Korean stock trading, these correspond to about 2 minutes and 6 seconds.

Evaluation of Datum Unit for Diagnostics of Journal-Bearing Systems (저널베어링의 이상상태 진단을 위한 데이텀 효용성 평가)

  • Jeon, Byungchul;Jung, Joonha;Youn, Byeng D.;Kim, Yeon-Whan;Bae, Yong-Chae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.8
    • /
    • pp.801-806
    • /
    • 2015
  • Journal bearings support rotors using fluid film between the rotor and the stator. Generally, journal bearings are used in large rotor systems such as turbines in a power plant, because even in high-speed and load conditions, journal bearing systems run in a stable condition. To enhance the reliability of journal-bearing systems, in this paper, we study health-diagnosis algorithms that are based on the supervised learning method. Specifically, this paper focused on defining the unit of features, while other previous papers have focused on defining various features of vibration signals. We evaluate the features of various lengths or units on the separable ability basis. From our results, we find that one cycle datum in the time-domain and 60 cycle datum in the frequency domain are the optimal datum units for real-time journal-bearing diagnosis systems.

Profiling of Urinary Environmental Estrogens by Gas Chromatography/Mass Spectrometry (GC/MS를 이용한 뇨 중 환경 에스트로겐들의 동시 프로필)

  • Yang, Yoon-Jung;Lee, Seon-Hwa;Chung, Bong-Chul
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.265-272
    • /
    • 1999
  • A simultaneous profile analysis of 19 environmental estrogens, which act like estrogen and may effect the endocrine system by binding to hormone receptors or influencing cell signaling pathways, was attempted. The present method was based on the selected ion monitoring (SIM) mode of gas chromatography/mass spectrometry (GC/MS). It involves solid-liquid extraction, enzyme hydrolysis, liquid-liquid extraction and quantitative conversion into trimethylsilyl (TMS)-ether derivatives. Analytical recovery range was 47.6 ~ 99.5% and the RSD values of within-a-day and day-to-day test were 0.66 ~ 9.33%, 1.66 ~ 16.14%, respectively. The Korean reference values for the evaluation of environmental estrogen effects were established by this method.

  • PDF

Calculation of Multiple Scattering in Water Cloud and Application in Remote Measurement of Cloud Physical Properties (구름에서의 다중산란효과 계산 및 이를 이용한 구름 물리변수 원격 추출 방법 연구)

  • Kim, Dukhyeon;Park, Sunho;Choi, Sungcheol
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Multiple scattering effects in cloud are important error sources of the Mie scattering Lidar inversion method, which should be measured to correct the Lidar equation in single wavelength Mie Lidar. We have calculated the multiple scattering effects in liquid water clouds by using a Monte Carlo method, and we have applied these multiple scattering effects in measuring water cloud effective size and LWC (Liquid Water Content). When cloud effective size is less than $2.5{\mu}m$, we can easily extract cloud effective size and LWC by using two wavelength Lidar such as extinction coefficients measured at 355nm and 1064nm. For a larger size cloud, we can find that saturated degree of linear polarization is strongly correlated with cloud effective size, LWC, and extinction coefficients. From these correlations we know that we can measure LWC and cloud effective size if we use single wavelength Rotational Raman Lidar and Mie scattering polarization Lidar.