• Title/Summary/Keyword: 신뢰성 시험(reliability test)

Search Result 873, Processing Time 0.036 seconds

Study of Confidence Ranges for Field Phase Difference Measurement Data Collected using Geophones (지오폰을 활용한 현장 위상각차 계측 데이터 신뢰 구간에 관한 기초 연구)

  • Kim, Gunwoong
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.3
    • /
    • pp.41-54
    • /
    • 2024
  • Regular monitoring plays a crucial role in ensuring the safety of geotechnical structures. Currently, nondestructive methods are employed to monitor such structures to minimize the impact, e.g., sensor-based accelerometers, displacement meters, image-based lasers, and drone imaging. These technologies can observe surface changes; however, they frequently suffer difficulties in terms of identifying changes in internal properties. To monitor changes in internal properties, in situ geotechnical investigations can be employed. A nondestructive test that can be used for this purpose is the spectral analysis of surface wave (SASW) test using geophones. The SASW test is a nondestructive method; however, due to the time required for data interpretation and the difficulty in analyzing the data, it is challenging to use the SASW test for monitoring applications that require frequent observations. However, it is possible to apply the first-step analysis, which yields the dispersion curve, for monitoring rather than the complete SASW analysis, which yields the shear wave velocity. Thus, this paper presents a fundamental study on the phase difference that derives the dispersion curve to utilize the SASW test for monitoring. The reliability of each phase difference interval is examined to determine the boundary to the subjected monitor. The study used phase difference data obtained using a geophone from a single-layered, homogeneous ground site to evaluate reliable boundaries. The findings of this study are expected to improve the utility of monitoring by identifying the ideal boundary for phase difference data.

Estimation of Dynamic Material Properties for Fill Dam : II. Nonlinear Deformation Characteristics (필댐 제체 재료의 동적 물성치 평가 : II. 비선형 동적 변형특성)

  • Lee, Sei-Hyun;Kim, Dong-Soo;Choo, Yun-Wook;Choo, Hyek-Kee
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.12
    • /
    • pp.87-105
    • /
    • 2009
  • Nonlinear dynamic deformation characteristics, expressed in terms of normalized shear modulus reduction curve (G/$G_{max}-\log\gamma$, G/$G_{max}$ curve) and damping curve (D-$\log\gamma$), are important input parameters with shear wave velocity profile ($V_s$-profile) in the seismic analysis of (new or existing) fill dam. In this paper, the reasonable and economical methods to evaluate the nonlinear dynamic deformation characteristics for core zone and rockfill zone respectively are presented. For the core zone, 111 G/$G_{max}$ curves and 98 damping curves which meet the requirements of core material were compiled and representative curves and ranges were proposed for the three ranges of confining pressure (0~100 kPa, 100 kPa~200 kPa, more than 200 kPa). The reliability of the proposed curves for the core zone were verified by comparing with the resonant column test results of two kinds of core materials. For the rockfill zone, 135 G/$G_{max}$ curves and 65 damping curves were compiled from the test results of gravelly materials using large scale testing equipments. The representative curves and ranges for G/$G_{max}$ were proposed for the three ranges of confining pressure (0~50 kPa, 50 kPa~100 kPa, more than 100 kPa) and those for damping were proposed independently of confining pressure. The reliability of the proposed curves for the rockfill zone were verified by comparing with the large scale triaxial test results of rockfill materials in the B-dam which is being constructed.

A Study on the Atmospheric Pressure Control of the VARTM Process for Increasing the Fiber Volume Fraction and Reducing Void (섬유부피분율 증가와 공극 감소를 위한 VARTM 공정의 대기압 제어에 관한 연구)

  • Kwak, Seong-Hun;Kim, Tae-Jun;Tak, Yun-Hak;Kwon, Sung-Il;Lee, Jea-Hyun;Kim, Sang-Yong;Lee, Jong-Cheon
    • Composites Research
    • /
    • v.34 no.2
    • /
    • pp.88-95
    • /
    • 2021
  • VARTM (Vacuum-assisted resin transfer molding) process is a low-cost process technology and affiliated with OoA (Out of Autoclave). Besides, it has been widely used in various fields. However, because of its lower quality than the autoclave process, it isn't easy to apply the VARTM process to the aerospace industry, which requires high reliability. The main problem of the VARTM process is the loss of mechanical properties due to the low fiber volume fraction and high void content in comparison to the autoclave. Therefore, many researchers have studied to reduce void and increase fiber volume fraction. This study examines whether the method of controlling atmospheric pressure could increase the fiber volume fraction and reduce void during the resin impregnation process. Reliability evaluation was confirmed by compressive strength test, fiber volume fraction analysis, and optical microscopy. As a result, it was confirmed that increasing the atmospheric pressure step by step in the VARTM process of impregnating the preform with resin effectively increases the fiber volume fraction and reduces void.

Effects of Kalopanax Pictus Extracts and Their Related Origin on Gastric Lesions (해동피 및 유사생약 추출물의 위 손상에 대한 효과)

  • Hwang, In Young;Hwang, Seon A;Jeong, Choon Sik
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.4
    • /
    • pp.367-375
    • /
    • 2013
  • Kalopanax pictus has pharmacologically anti-inflammatory and analgesic effect and is known to respond to treatment of backache, knee pain and etc. In this study, we investigated the effects on gastric lesions of Kalopanax pictus both from Korea (KPK) and China (KPC) compared with their related origin, Znthoxylum ailanthoide both from Korea (ZAK) and China (ZAC), and Korean Bombax malabaricum (BMK). In preliminary screening, KPK and KPC shown effective inhibition of HCI EtOH-induced gastritis in rats. To elucidate their protective effects on gastric lesions, we assessed inhibition of H. pylori colonization, 2,2-diphenyl-1-picrylhydrazyl(DPPH) radical scavenging activities, reducing power test, and inhibition of lipid peroxidation. KPK was the most effective from antioxidant assays. KPK also shown the inhibition of indomethacin-induced gastric ulcer in rats. Gastric secretion in rats, KPK reduced the secretion of gastric juice and total acidity and raised pH. Therefore, it is possible that KPK can be developed as health functional food and natural medicine. In addition, it can contribute to the standardization with objectivity and reliability for KPK through the criteria establishment of the precise origin of medicine, the prevention of indiscriminate distribution of imitation, and the rising rate of dependence on imports of medicinal herbs, and mixing prevention of low-quality goods.

Quality Analysis of Fly Ash Through Correlation between Density by Hydrometer and Test Report (Hydrometer법을 이용한 밀도 측정값과 시험 성적서간 상관분석을 통한 플라이애시의 품질특성 분석)

  • Song, Heung-Ho;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.4
    • /
    • pp.305-312
    • /
    • 2017
  • To evaluate the reliability of fly ash quality supplied to ready-mixed concrete plant using mass cylinder and hydrometer, in this research, the correlationship between the fly ash properties provided from certification and density measurement with suspension was evaluated. As a result, the reliability of the certification, except fineness and loss on ignition, all properties had a discord. Additionally, in the case of density, fineness, and L.O.I, the relation with the density measured using hydrometer showed high correlation, especially fineness was strongly related with the density measured using hydrometer. Furthermore, according to the comparative analysis with previous research, the fly ash used in this research was similar measurement with raw powder without any refining process, it is considered that the constant error of blaine test or using raw ash sample as a fly ash. In current standard regarding fly ash, the fineness range of class 2 can be changed from $3,000-4,500cm^2/g$ to $3,500-4,500cm^2/g$ for improved quality of fly ash in fineness aspect.

Structural Performance Evaluation of Anchors for Power Equipment Electrical Cabinets Considering On-Site Installation Conditions (현장 설치 조건을 고려한 발전설비 전기 캐비닛 정착부 앵커의 구조성능 평가)

  • Lee, Sang-Moon;Jung, Woo-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.709-719
    • /
    • 2023
  • In general, most of the electrical equipment responsible for control within power plants is housed in self-standing cabinets. These cabinets are typically fixed to a slab using post-installed anchors. Although the fixation method of using post-installed anchors provides stability, there is a risk of conductor failure due to external forces, including moments. However, the performance assessment of current anchors is only evaluated through uniaxial material tests. Therefore, the primary purpose of this study is to compare the static performance of post-installed anchors, considering on-site installation conditions, with their performance in material tests and to analyze the behavioral characteristics of the anchors. While conducting experiments using actual cabinets would be ideal, practical and spatial constraints make this approach difficult. As an alternative, experiments were conducted using a test specimen consisting of a steel column and a support. As a result, the pull-out performance of anchors reflecting on-site installation conditions was measured to be about 10% higher than that observed in material tests. The trends in load reduction and the point of maximum performance for the anchors also differed. To verify the reliability of the experimental study, a 3D FEM analysis was performed, which will provide predictive information on the loads transferred to the post-installed anchors for structural performance evaluations of electrical cabinets using shaking table test in the future.

The Design of Switching-Mode Power Amplifier and Ruggedness Characteristics Analysis of Power Amplifier Using GaN HEMT (GaN HEMT를 이용한 스위칭 모드 전력증폭기 설계 및 전력증폭기의 Ruggedness 특성 분석)

  • Choi, Gil-Wong;Lee, Bok-Hyoung;Kim, Hyoung-Joo;Kim, Sang-Hoon;Choi, Jin-Joo;Kim, Dong-Hwan;Kim, Seon-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.4
    • /
    • pp.394-402
    • /
    • 2013
  • This paper presents design, fabrication and ruggedness test of switching-mode power amplifier using GaN(Gallium Nitride) HEMT(High Electron Mobility Transistor) for S-band radar applications. The power amplifier is designed to Class-F for high efficiency. The input signal for the measurement of the power amplifier is pulse signal at $100{\mu}s$ pulse width and duty cycle of 10 %. The measurement results of the fabricated Class-F power amplifier are a power gain of 10.8 dB, an output power of 40.8 dBm, a power added efficiency(PAE) of 54.2 %, and a drain efficiency of 62.6 %, at the center frequency. We proposed reliability test set-up of a power amplifier for ruggedness test. And we measured output power and efficiency according to VSWR(Voltage Standing Wave Ratio) variation. The designed power amplifier achieved output power of 32.6~41.1 dBm and drain efficiency of 23.4~63 % by changing VSWR, respectively.

Solderability of thin ENEPIG plating Layer for Fine Pitch Package application (미세피치 패키지 적용을 위한 thin ENEPIG 도금층의 솔더링 특성)

  • Back, Jong-Hoon;Lee, Byung-Suk;Yoo, Sehoon;Han, Deok-Gon;Jung, Seung-Boo;Yoon, Jeong-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.1
    • /
    • pp.83-90
    • /
    • 2017
  • In this paper, we evaluated the solderability of thin electroless nickel-electroless palladium-immersion gold (ENEPIG) plating layer for fine-pitch package applications. Firstly, the wetting behavior, interfacial reactions, and mechanical reliability of a Sn-3.0Ag-0.5Cu (SAC305) solder alloy on a thin ENEPIG coated substrate were evaluated. In the wetting test, maximum wetting force increased with increasing immersion time, and the wetting force remained a constant value after 5 s immersion time. In the initial soldering reaction, $(Cu,Ni)_6Sn_5$ intermetallic compound (IMC) and P-rich Ni layer formed at the SAC305/ENEPIG interface. After a prolonged reaction, the P-rich Ni layer was destroyed, and $(Cu,Ni)_3Sn$ IMC formed underneath the destroyed P-rich Ni layer. In the high-speed shear test, the percentage of brittle fracture increased with increasing shear speed.

Performance verification methods of an inertial measurement unit in flight environment using the real time dual-navigation (실시간 다중항법을 이용한 관성측정기의 비행환경 성능 검증 기법)

  • Park, ByungSu;Lee, SangWoo;Jeong, Sang Mun;Han, KyungJun;Yu, Myeong-Jong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.1
    • /
    • pp.36-45
    • /
    • 2017
  • Abstract It is necessary to verify the properties of an inertial measurement unit in the flight environment before applying to military applications. In this paper, we presented a new approach to verify an inertial measurement unit(IMU) in regard to the performance and the robustness in flight environments for the high-dynamics vehicle systems. We proposed two methods for verification of an IMU. We confirmed normal operation of an IMU and properties in flight environment by using direct comparison method. And we proposed real time multi-navigation system to complement the first method. The proposed method made it possible to compare navigation result at the same time. Therefore, it is easy to analyze the performance of an inertial navigation system and robustness during the vehicle flight. To verify the proposed method, we carried out a flight test as well as an experimental test of flight vibration on the ground. As a result of the experiment, we confirmed flight environment properties of an IMU. Therefore, we shows that the proposed method can serve the reliability improvement of IMU.

Development and Verification of Active Vibration Control System for Helicopter (소형민수헬기 능동진동제어시스템 개발)

  • Kim, Nam-Jo;Kwak, Dong-Il;Kang, Woo-Ram;Hwang, Yoo-Sang;Kim, Do-Hyung;Kim, Chan-Dong;Lee, Ki-Jin;So, Hee-Soup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.3
    • /
    • pp.181-192
    • /
    • 2022
  • Active vibration control system(AVCS) for helicopter enables to control the vibration generated from the main rotor and has the superb vibration reduction performance with low weight compared passive vibration reduction device. In this paper, FxLMS algorithm-based vibration control software of the light civil helicopter tansmits the control command calculated using the signals of the tachometer and accelerometers to the circular force generator(CFG) is developed and verified. According to the RTCA DO-178C/DO-331, the vibration control software is developed through the model based design technique, and real-time operation performance is evaluated in PILS(processor in-the loop simulation) and HILS(hardware in-the loop simulation) environments. In particular, the reliability of the software is improved through the LDRA-based verification coverage in the PIL environments. In order to AVCS to light civil helicopter(LCH), the dynamic response characteristic model is obtained through the ground/flight tests. AVCS configuration which exhibits the optimal performance is determined using system optimization analysis and flight test and obtain STC certification.