• Title/Summary/Keyword: 시 치료

Search Result 5,587, Processing Time 0.029 seconds

A Study on Prospective Plan Comparison using DVH-index in Tomotherapy Planning (토모 테라피 치료 시 선량 체적 히스토그램 표지자를 이용한 치료계획 비교에 관한 연구)

  • Kim, Joo-Ho;Cho, Jeong-Hee;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Yoon, Jong-Won;Kim, Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.113-122
    • /
    • 2007
  • Purpose: We proposed the method using dose-volume Histogram index to compare prospective plan trials in tomotherapy planning optimization. Materials and Methods: For 3 patients in cranial region, thorax and abdominal region, we acquired computed tomography images with PQ 5000 in each case. Then we delineated target structure and normal organ contour with pinnacle Ver 7.6c, after transferred each data to tomotherapy planning system (hi-art system Ver 2.0), we optimized 3 plan trials in each case that used differ from beam width, pitch, importance. We analyzed 3 plan trials in each region with isodose distribution, dose-volume histogram and dose statistics. Also we verified 3 plan trials with specialized DVH-indexes that is dose homogeneity index in target organ, conformity index around target structure and dose gradient index in non-target structures. Results: We compared with the similarity of results that the one is decide the best plan trial using isodose distribution, dose volume histogram and dose statistics, and the another is using DVH-indexes. They all decided the same plan trial to better result in each case. Conclusion: In some of case, it was appeared a little difference of results that used to DVH-index for comparison of plan trial in tomotherapy by special goal in it. But because DVH-index represented both dose distribution in target structure and high dose risk about normal tissue, it will be reasonable method for comparison of many plan trials before the tomotherapy treatments.

  • PDF

The Evaluation of the dose calculation algorithm(AAA)'s Accuracy in Case of a Radiation Therapy on Inhomogeneous tissues using FFF beam (FFF빔을 사용한 불균질부 방사선치료 시 선량계산 알고리즘(AAA)의 정확성 평가)

  • Kim, In Woo;Chae, Seung Hoon;Kim, Min Jung;Kim, Bo Gyoum;Kim, Chan Yong;Park, So Yeon;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.321-327
    • /
    • 2014
  • Purpose : To verify the accuracy of the Ecilpse's dose calculation algorithm(AAA:Analytic anisotropic algorithm) in case of a radiation treatment on Inhomogeneous tissues using FFF beam comparing dose distribution at TPS with actual distribution. Materials and Methods : After acquiring CT images for radiation treatment by the location of tumors and sizes using the solid water phantoms, cork and chest tumor phantom made of paraffin, we established the treatment plan for 6MV photon therapy using our radiation treatment planning system for chest SABR, Ecilpse's AAA(Analytic anisotropic algorithm). According to the completed plan, using our TrueBeam STx(Varian medical system, Palo Alto, CA), we irradiated radiation on the chest tumor phantom on which EBT2 films are inserted and evaluated the dose value of the treatment plan and that of the actual phantom on Inhomogeneous tissue. Results : The difference of the dose value between TPS and measurement at the medial target is 1.28~2.7%, and, at the side of target including inhomogeneous tissues, the difference is 2.02%~7.40% at Ant, 4.46%~14.84% at Post, 0.98%~7.12% at Rt, 1.36%~4.08% at Lt, 2.38%~4.98% at Sup, and 0.94%~3.54% at Inf. Conclusion : In this study, we discovered the possibility of dose calculation's errors caused by FFF beam's characteristics and the inhomogeneous tissues when we do SBRT for inhomogeneous tissues. SBRT which is most popular therapy method needs high accuracy because it irradiates high dose radiation in small fraction. So, it is supposed that ideal treatment is possible if we minimize the errors when planning for treatment through more study about organ's characteristics like Inhomogeneous tissues and FFF beam's characteristics.

Treatment of Developmental Dislocation of the Hip in Walking Age (보행기의 발달성 고관절 탈구의 치료)

  • Kim, Se-Dong;Jang, Jae-Hyuk;Lee, Dong-Chul;Shin, Duk-Seop
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.2
    • /
    • pp.211-224
    • /
    • 1996
  • The patients of developmental dislocation of the hip(DDH) are almost found after walking age because of early diagnosis of DDH in younger children is not easy. A controversy still exists as to the relative value of closed and operative management in the treatment of a child who has reached walking age. This study is a report of the results of 16 patients(17 cases) in developmental dislocation of the hip who have visited our hospital at the age of 9 months to 3 years old, and have been followed more than 12 months (12-112 months) on review of plain radiographs and arthrograms. The results were as follows : 1. The age at diagnosis was 16.4 months(9-31 months) in average. The methods of treatment were conservative for 8 cases, and operation for 4 cases and secondary operation for 5 cases who were failed with conservative therapy. 2. By Severin's radiologic grade, the result was good in 4 cases, fair in 3 cases and poor in 1 case in conservative treatment. In operative treatment, fair was in 2 cases and poor in 2 cases. In secondary operative patients who were failed with conservative therapy, good was in 2 cases, fair in 2 cases and poor in 1 case. 3. Avascular necrosis of femoral head was developed in 3 cases. 4. In the good reduction as determined by arthrogram according to Race and Herring, we can get a favorable result in conservative treatment, and in the poor reduction as determined by arthrogram, the better result in operative treatment can be expected.

  • PDF

Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis (골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용)

  • Kim, Bo-Kyung;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 2002
  • The accuracy of radiation dose delivery to target volume is one of the most important factors for good local control and less treatment complication. In vivo dosimetry is an essential QA procedure to confirm the radiation dose delivered to the patients. Transmission dose measurement is a useful method of in vivo dosimetry and it's advantages are non-invasiveness, simplicity and no additional efforts needed for dosimetry. In our department, in vivo dosimetry system using measurement of transmission dose was manufactured and algorithms for estimation of transmission dose were developed and tested with phantom in various conditions successfully. This system was applied in clinic to test stability, reproducibility and applicability to daily treatment and the accuracy of the algorithm. Transmission dose measurement was performed over three weeks. To test the reproducibility of this system, X-tay output was measured before daily treatment and then every hour during treatment time in reference condition(field size; $10 cm{\times} 10 cm$, 100 MU). Data of 11 patients whose pelvis were treated more than three times were analyzed. The reproducibility of the dosimetry system was acceptable with variations of measurement during each day and over 3 week period within ${\pm}2.0%$. On anterior- posterior and posterior fields, mean errors were between -5.20% and +2.20% without bone correction and between -0.62% and +3.32% with bone correction. On right and left lateral fields, mean errors were between -10.80% and +3.46% without bone correction and between -0.55% and +3.50% with bone correction. As the results, we could confirm the reproducibility and stability of our dosimetry system and its applicability in daily radiation treatment. We could also find that inhomogeneity correction for bone is essential and the estimated transmission doses are relatively accurate.

Clinical effects of additional use of erythritol powder air polishing device on non-surgical periodontal treatment in moderate chronic periodontitis (중등도 만성 치주염 환자에서 erythritol 공기분말 연마기구를 부가적으로 이용하는 비외과적 치주치료의 임상적 효과)

  • Lee, Mun-Young;Park, Eon-Jeong;Kwon, Eun-Young;Kim, Hyun-Joo;Lee, Ju-Youn;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.39-45
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the clinical effects of erythritol powder air polishing device (EPAP) in addition to scaling and root planing (SRP) in non-surgical periodontal treatment in moderate chronic periodontitis patients. Materials and Methods: Clinical evaluation was performed at 21 sites treated with SRP (control) and 21 sites treated with the addition of SRP+EPAP (test). All examinations were performed before treatment, 1 month after treatment, and 3 months after treatment. Depth of the periodontal pocket, gingival recession, clinical attachment level, plaque index, and bleeding of probing were measured as clinical parameters. Results: In both test and control groups, there was a significant decrease in the depth of the periodontal pocket, plaque index, bleeding of probing, increased gingival recession, and gain of clinical attachment level at 1 month and 3 months after treatment. However, there was no significant clinical difference between the test group and the control group. Clinical result was improved after 1 month compared to the baseline; in contrast, results at 3 months after treatment were worse than at 1 month after treatment. Conclusion: In this study, we cannot suggest that SRP + EPAP is clinically more effective than SRP alone as non-surgical periodontal treatments. Periodic periodontal therapy, at intervals of at least every three months, is important for sustaining effects of this treatment.

고선량율 근접치료에서 기존의 필름 방법과 CT 재구성 방법의 정확성 비교 연구

  • 장지나;서태석;허순녕;윤세철;김회남;이형구;최보영
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.58-58
    • /
    • 2003
  • 목적 : 본 연구에서는 C-arm과 CT에 사용 가능한 자궁경부암용 팬톰을 개발하고 이를 이용하여 기존의 필름 방법에 기반한 위치 확인 방법과 CT 재구성 방법의 정확성을 비교 연구하고자 한다. 정확성이 검증된 후에는 두 방법의 장점을 이용하기 위해 CT로 재구성된 좌표를 필름의 좌표로 변환시켜 현재 사용되고 있는 필름에 기반한 근접 치료 계획 시행에 도움을 주고자 한다. 방법 : 자체 제작한 자궁경부암용 팬톰은 인체 등가 물질인 물과 아크릴을 사용하였고, 크게 localizer 부분과 팬톰 부분으로 구성되어 있다. 또한, 실제 자궁경부암 환자의 임상적인 구조를 모사하여 제작하였다. 자궁경부암 치료시 중요 장기인 방광과 직장을 구와 원기둥으로 설계하였고, 고선량율 applicator는 아크릴 판의 흠으로 고정시켜 제작하였기 때문에 CT 촬영시 applicator를 제거한 영상에서도 applicator의 구조가 정확하게 묘사될 수 있도록 제작하였다. 두 시스템에서 재구성된 좌표를 비교하기 위해 각각의 시스템에서의 얻은 재구성 좌표와 팬톰 자체의 localizer와 재구성 알고리즘을 바탕으로 개발된 프로그램을 이용하여 얻은 좌표로 두 재구성 좌표의 비교 연구를 수행하였다. 정확성이 검증되고 장기의 정보가 담긴 CT의 좌표는 자체 개발된 프로그램으로 2 차원의 필름 좌표로 변환되었다. 본 연구에 사용된 모든 프로그램은 ILD 5.5를 사용하여 개발되었다. 결과 : 두 시스템의 좌표 비교 결과 x, y 축은 차이가 2mm 이내로 비교적 정확한 실험 결과를 얻을 수 있었고, z 축의 경우 CT 슬라이드의 굵기에 따라 2mm-3mm 이내의 차이가 있음을 관찰할 수 있었다. z 축을 제외한 좌표의 차이는 획득한 영상에서 컴퓨터로 좌표를 옮기는 localizer 좌표 선택 과정에 발생했을 것으로 예상된다. 또한, 이 검증된 좌표와 개발된 프로그램을 이용하여 우리는 CT의 좌표를 2차원의 필름 좌표로 정확하게 변환할 수 있었다. 결론 : 이 연구로부터 기존의 C-arm 재구성 방법과 CT 재구성 방법의 비교를 통해 각 치료 기기의 신뢰성을 직접 확인할 수 있었으며, 비교를 통해 검증된 CT의 좌표를 필름 좌표로 변환시킴으로서, 각 시스템의 장점만을 결합한 효과적인 치료 계획을 세울 수 있는 가능성을 제시하였다. 또한 물과 아크릴을 사용한 비교적 간단하고 경제적인 방법으로 C-arm, CT 그리고 MRI에 모두 이용 가능한 팬톰을 제작하여 쉽고 정확하게 위치를 확인할 수 있었다. 더 나아가, 본 연구에서 제작된 자궁경부암 팬톰은 근접치료를 포함하여 관련 팬톰 개발에 도움을 줄 수 있을 것으로 예상된다.

  • PDF

Estimation of Dose Distribution on Carbon Ion Therapy Facility using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 중입자 치료실의 선량분포 추정)

  • Song, Yongkeun;Heo, Seunguk;Cho, Gyuseok;Choi, Sanghyun;Han, Moojae;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.437-442
    • /
    • 2017
  • Heavy ion therapy has a high cure rate for cancer cell. So many countries are introducing heavy ion therapy facility. When treating a cancer using heavy ion therapy, neutrons and gamma rays are generated and affect electronic equipment. A budget of about KRW 200 billion is needed to build a heavy ion therapy facility, and it takes more than five years to build it. Therefore it is important to observe the dose distribution in the treatment room using the monte carlo simulation before construction. In this study, we used the FLUKA of monte carlo simulation to investigate the dose distribution in the heavy ion treatment room.

식도 천공의 외과적 치료

  • 이재익
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 2003.09a
    • /
    • pp.108-108
    • /
    • 2003
  • 식도 천공의 치료는 최근 치료법의 발전에도 불구하고 여전히 난해한 문제이다. 이 환자들은 천공의 원인이나 위치, 심한 정도가 다양한 이질적인 군이며, 반수 이상이 이미 식도에 기존의 질환을 가지고 있어 문제를 더욱 복잡하게 한다. 따라서 절대적이고 획일적인 치료방법은 아직 확립되어 있지 않으며 많은 다양한 방법들이 제시되고 있다. 2002년 11월부터 2003년 7월까지 총 8명의 환자가 식도 천공으로 동아대학교병원 흥부외과에서 치료를 받았으며, 원인별로는 의인성(iatrogenic) 손상이 6례, 자발성(spontaneous) 손상이 2례였고 부위별로는 경부가 3례, 흥부가 5례였다. 의인성 손상에는 내시경 검사중 정상 경부 식도에 발생한 1례, 부식성 식도협착 환자의 풍선 확장술과 스텐트 삽입시 흉부 식도에 발생한 경우가 각각 1례씩, 외상성 경추손상의 수술시 정상 경부 식도에 발생한 경우가 2례, 선천성 식도폐쇄증(esophageal atresia)의 술후 문합부 누출이 생긴 경우가 1례 있었으며, 자발성 손상에는 하부식도에 발생한 기압성(barogenic) 손상 1례와 상흉부 식도암 천공 1례가 있었다. 경부 식도 천공 3례는 모두 경부 배액(drainage)과 식이용 장루술(feeding jejunostomy)을 시행하였고, 부식성 식도협착이 있던 환자 2례는 식도절제술과 흉부내 식도-위 문합을 시행하였으며, Boerhaave씨 증후군 환자는 1차 봉합술, 술후 문합부 유출이 있었던 환자와 식도암 천공이 있었던 환자는 식도절제 및 경부 식도루(esophagostomy), 배액용 위루(gastrostomy), 식이용 장루술을 시행하였다. 모든 환자는 패혈증 등의 심각한 합병증으로의 진행 없이 회복되었다. 현재 위장관의 연속성이 유지 혹은 복원된 환자는 경구식이 중이며 그 외의 환자들은 장루를 통해 영양을 공급하며 식도재건술을 기다리고 있다. 식도 천공은 최근 항생제의 사용, 과영양요법(hyperalimentation), 술후 환자관리의 개선 등으로 치료에 많은 발전이 있었으나, 치료 방침에 있어서는 여전히 논란이 있으며 높은 사망률을 보이는 난제로 남아있다. 비록 일반적인 지침이 도움이 되겠지만, 치료 방침은 환자 개개인의 상황에 따라 적절하게 선택해야 하며, 임상경과에 따라 언제라도 방침을 변경할 수 있는 유연함이 필요하리라 생각한다.

  • PDF

Development of Periventricular Leukomalacia and Severe Intraventricular Hemorrhage in Very Low Birth Weight Newborns and Relationship with Ventilator Care (Study of Ventilator Care as a Risk Factor of PVL and PV-IVH) (극소저출생체중아의 뇌실주위백질연화증과 중증뇌실출혈의 발생과 인공호흡기 치료와의 상관관계)

  • Lee, Hak Sung;Lee, Sae Kyu;Kim, Yeong Jin;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.12
    • /
    • pp.1330-1336
    • /
    • 2005
  • Purpose : It has been suggested that changes in cerebral blood flow by ventilator care could be a risk factor in periventricular leukomalacia(PVL) and severe periventricular-intraventricular hemorrhage(PV-IVH). The study aims to assess the relationship between perinatal clinical events, including ventilator care, and the development of PVL and severe PV-IVH; especially, whether ventilator care could be causers of PVL and severe PV-IVH as an individual risk factor. Methods : Among 255 very low birth weight infants who survived in the Fatima neonatal intensive care unit from January 1999 to December 2003, 15 infants with PVL and eight infants with severe PV-IVH were classified as a study group, while 231 infants were enrolled as a control group. The analysis was performed retrospectively with medical records. Results : Twenty four infants were diagnosed with PVL or severe PV-IVH. Asphyxia, recurrent apnea, sepsis, acidosis and ventilator care were significantly increased in the PVL goup. Asphyxia, recurrent apnea, RDS, acidosis and ventilator care were significantly increased in the severe PV-IVH group. Conclusion : Infants with PVL or severe PV-IVH may have multiple perinatal risk factors including asphyxia, recurrent apnea, sepsis, acidosis, RDS and ventilator care. Because most patients with ventilator care have multiple perinatal risk factors, ventilator care does not cause PVL and severe PV-IVH independently. Therefore, incidences of PVL and severe PV-IVH can be decreased by not only gentle ventilation, but also more professional antenatal care.

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.