• Title/Summary/Keyword: 시험편두께

Search Result 99, Processing Time 0.028 seconds

Fracture toughness and AE Characteristics of Engineering plastic according to thickness (두께변화에 따른 엔지니어링 플라스틱의 파괴인성과 AE특성)

  • 남기우;김선진;안병현
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.51-57
    • /
    • 1996
  • A standard method for the evalution of the fracture toughness of the high polymer materials has not been fully developed in comparison with that for metallic materials, and has not yet established. In this paper, fracture toughness tests using polycarbonate specimens were carried out. The fracture thughness tests using polycabonate specimens were carried out. The fracture toughness of commercial polycarbonate were dependent on the specimen thickness. The specimen thickness is necessary above 8mm to obtain the valid $K_{IC}$. A cumulative counts were slightly dependent on specimen thickness.

  • PDF

A Study of Improving the Tensile Strength for Spot Welding (점용접의 인장강도 개선에 관한 연구)

  • Hwang, Nam-Seong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.1
    • /
    • pp.43-48
    • /
    • 2003
  • 점용접은 자동차를 제작하는데 사용하는 가장 유용한 용접법이다. 그러나 산업현장에서 직면하고 있는 가장 큰 문제점 중의 하나는 점용접의 용접성에 관한 문제이다. 본 연구에서는 강판의 두께가 1.6mm인 경우와 1.2mm인 경우에 대해 2점 점용접을 실시하여 인장강도를 증가시키고 용접의 흔적을 남기지 않게 하기 위한 조건을 찾는 것을 목적으로 하였다. 용접성에 영향을 미치는 많은 요소들이 있다. 그중에서 용접전극의 형상이 인장강도를 증가시키는 요소로 집중을 하면서 연구를 수행하여 다음과 같은 결과를 얻었다. 인장강도는 용접전극의 형상 및 팁직경 거리와 전류가 클수록 증가하였다. 시행 착오법을 통해 최적용접조건을 찾았고 그에 따른 최적전류인 9,000A와 전극의 형상 RF형을 찾았다. 경도시험결과는 인장력이 시험편에 작용할 때 열 영향부인 HAZ부에서 왜 파괴가 일어나는지를 설명해 주었다.

  • PDF

A Study on Estimation of the Probability Distribution of Fatigue Crack Growth Life for Steels (강의 피로균열전파수명의 확률분포 추정에 관한 연구)

  • 김선진;윤성환;전창환;정규연;안석환
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.04a
    • /
    • pp.40-45
    • /
    • 2000
  • Presented are the estimation of the probability distribution of fatigue crack growth life and reliability assessment of structures by simulating material resistance to fatigue crack growth along a crack path. The material resistance is treated as a Weibull stochastic process. A non-Gaussian stochastic fields simulation method proposed by Shimozuka, et al is applied with the statistical data obtained experimentally. Test results are obtained for $\Delta$K constant amplitude load in tension with stress ratio of R=0.2 and three specimen thicknesses of 6, 12 and 18mm. This simulation method is useful to estimate the probability distribution of fatigue crack growth life and the smallest life.

  • PDF

A Study on Estimation of the Probability Distribution of Fatigue Crack Growth Life for Steels (강의 피로균열전파수명의 확률분포 추정에 관한 연구)

  • 김선진;윤성환;전창환;김일석
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.73-78
    • /
    • 2000
  • Presented are the estimation of the probability distribution of fatigue crack growth life and reliability assessment of structures by simulating material resistance to fatigue crack growth along a crack path. The material resistance is treated as a Weibull stochastic process. A non-Gaussian stochastic fields simulation method proposed by shimozuka, et al is applied with the statistical data obtained experimentally. Test results are obtained for $\delta K$ constant amplitude load in tension with stress ratio of R=0.2 and three specimen thicknesses of 6,12 and 18mm. This simulation method is useful to estimate the probability distribution of fatigue crack growth life and the smallest life.

  • PDF

Damage Evaluation of Glass Fiber/PET Composite Using Acoustic Emission Method (음향방출법을 이용한 Glass Fiber/PET 복합재료의 손상평가)

  • 김상태;김덕윤
    • Composites Research
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • In this study, damage evaluation of glass fiber reinforced thermoplastic composites was investigated with acoustic emission method. Specimens of 1.7mm thickness laminate were made from PET and 7 layers o171ass fabrics. Notch and impact loading were added to the specimen and normal tensile test and tensile test with the dead load were carried out. AE signal was measured as the functions of notch ratio to the width0 and impact energy in order to find out the correlation between fracture mode and AE parameters. The result has shown that low amplitude of AE signal was due to the microcrack of matrix and its growth, whereas the amplitude in the mid range was the response to the delamination and interfacial separation. In the range of high amplitude above 90dB. the fracture of glass fabric was found. Tensile strength decreased with increasing notch ratio to the width and impact energy because of tile effect or delamination, the cracking of matrix and stress concentration. In proportion to the size of damaged area. AE signal showed its wider range of frequency and energy as well as increased number of hits.

  • PDF

Manufacture of Crack-free Carbonized Board from Fiberboard (섬유판을 이용한 무할렬 탄화보드 제조)

  • Park, Sang-Bum;Lee, Sang-Min;Park, Jong-Young;Lee, Seon-Hwa
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.293-299
    • /
    • 2009
  • In manufacturing the crack-free carbonized boards using fiberboards, shrinking ratio, weight loss and density variation of carbonized boards at each carbonization temperature were investigated. Fiberboards with thickness of 3, 4.5, 6, and 18 mm were carbonized while pressed with pressure plates at different temperature from $400^{\circ}C$ to $1,000^{\circ}C$ using a ordinary laboratory furnace. Either of crack or twist was not observed in fiberboards by adapting the pressing carbonization method. The ratios of shrinkage of length, width, and thickness were 10~25%, 12~25%, and 28~48%, respectively, and shrinkage ratio of thickness was higher than those of length and width with increasing the carbonization temperature. Weight loss tended to increase with increasing the carbonization temperature, but low correlation between weight loss in thickness of fiberboards and carbonization temperature was observed. Density of 3 mm carbonized hardboard had the highest value and it tended to increase with increasing the carbonization temperature.

Scale Thickness Measurement of Steam Generator Tubing Using Eddy Current Signal of Bobbin Coil (보빈코일 와전류신호를 이용한 증기발생기 세관 스케일 두께 측정)

  • Kim, Chang-Soo;Um, Ki-Soo;Kim, Jae-Dong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.545-550
    • /
    • 2012
  • Steam generator is one of the major components of nuclear power plant and steam generator tubes are the pressure boundary between primary and secondary side, which makes them critical for nuclear safety. As the operating time of nuclear power plant increases, not only damage mechanisms but also scaled deposits on steam generator tubes are known to be problematic causing tube support flow hole blockage and heat fouling. The ability to assess the extent and location of scaled deposits on tubes became essential for management and maintenance of steam generator and eddy current bobbin data can be utilized to measure thickness of scale on tubes. In this paper, tube reference standards with various thickness of scaled deposit has been set up to provide information about the overall deposit condition of steam generator tubes, providing essential tool for steam generator management and maintenance to predict and prevent future damages. Also, methodology to automatically measure scale thickness on tubes has been developed and applied to field data to estimate overall scale amount.

Nondestructive Evaluation of Adhesive Bonding Quality by Measurements of Peak Amplitude of Simulated Stress Wave (모의 음향 방출 신호의 Peak Amplitude측정을 통한 복합 재료 접합부의 비파괴평가)

  • Son, Y.H.;Lee, J.O.;Lee, S.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.357-363
    • /
    • 1995
  • Disbond size of adhesively bonded single lap and double lap joints CFRP composite specimens has been evaluated using acousto-ultrasonic(AU) technique. Frequency spectra for all specimens were obtained by measuring peak amplitude of the stress wave propagated through the bond-lines. By analyzing these frequency spectra, peak amplitude was found to be proportional to fractional bonding area and to be maxima at the fundamental and the third order higher harmonic frequencies of specimen thickness mode. The disbond size can be evaluated quantitatively and this technique can be applied to real structures if the reference specimens are prepared in advancve.

  • PDF

Evaluation of Shape Parameter Effect on the J-R Curve of Curved CT Specimen Using Limit Load Method (한계하중법을 이용한 Curved CT 시험편의 파괴저항곡선에 미치는 형상변수 영향 평가)

  • Shin, In Hwan;Park, Chi Yong;Seok, Chang Sung;Koo, Jae Mean
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.7
    • /
    • pp.757-764
    • /
    • 2014
  • In this study, the effect of shape parameters on the J-R curves of curved CT specimens was evaluated using the limit load method. Fracture toughness tests considering the shape factors L/W and $R_m/t$ of the specimens were also performed. Thereafter, the J-R curves of the curved CT specimens were compared using the J-integral equation proposed in the ASTM (American Society for Testing and Materials) and limit load solution. The J-R curves of the curved CT specimens were also compared with those of the CWP (curved wide plate), which is regarded to be similar to real pipe and standard specimens. Finally, the effectiveness of the J-R curve of each curved CT specimen was evaluated. The results of this study can be used for assessing the applicability of curved CT specimens in the accurate evaluation of the fracture toughness of real pipes.

Convergence study of mechanical properties and biocompatability of Ti Gr4 surface coated with HA using plasma spray for ossoeintegration (골융합 촉진을 위한 Ti Gr4의 HA 코팅에 대한 물리적 특성과 생체안정성에 대한 융합적 연구)

  • Hwang, Gab-Woon
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.145-151
    • /
    • 2021
  • This study aimed to investigate the efficient conduct of HA coating on Ti Gr4 for the practical use of medical device. Ti Gr4 alloy specimens measuring 𝜱 25mm × 1mm were sprayed with hydroxyapatite using thermal spray according to ASTM F1185-88. The surface was evaluated at #120, #400, #1,000 sandpaper and barrel finishing. Each coating properties was analyzed using SEM, UTS 20,000psi cap. and in vitro cytotoxicity. Surface morphology consists of well molten particles with very little resolidified or unmolten areas. The average Ca/P ratio is 1.74 which is in good agreement with theoretical value of 1.67. The average roughness Ra is very representative of roughness of specimen. The coatings are dense and well adhered to the substrate. The average bond strength was 61.74 MPa with a standard deviation of 4.06 which indicates fairly reliable results for ASTM 633 type tests. Variations in results from jig design, epoxy used, crosshead speeds etc. in vitro cytotoxicity result had a Grade 3. The results of the study are expected to be helpful in osseointegration and plasma-spray HA coated Ti Gr4 are more satisfactory in HA coating thickness elevation which is preferable to any other system.