• Title/Summary/Keyword: 시추공-지표간 전기비저항 탐사

Search Result 8, Processing Time 0.021 seconds

Application of Electrical Resistivity Tomography Using Single Well in Seawater Intrusion Areas (해수침투지역에서 단일 시추공을 이용한 전기비저항 토모그래피 탐사의 적용성)

  • Song, Sung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.369-376
    • /
    • 2007
  • Electrical resistivity tomography was carried out at seawater intrusion monitoring wells located at watershed in coastal areas. It is difficult to identify the characteristics of resistivity near monitoring well in case of using high signalto-noise ratio array due to the high conductivity condition in coastal aquifer although electrical resistivity survey is well adopted to delineate hydrogeological characteristics with the distribution of electrical resistivity. To improve the quality of electrical resistivity survey for two sites with seawater intrusion monitoring wells, inversion with the results of holeto-surface electrical resistivity tomography using single well was executed. The results of inversion for aquifer near wells were verified with the results of drilling log with the informations of fracture, electrical conductivity logging and normal resistivity logging. The inversion for aquifer near one of two wells was also performed at low and high tide with the same electrodes, respectively. From the inversion result, it is possible to obtain the resistivity images with high resolution and to identify the characteristics of aquifer related to seawater intrusion with tidal fluctuation. From this study, it was demonstrated that the hole-to-surface electrical resistivity tomography method accompanied with drilling log, electrical conductivity logging and normal resistivity logging would be useful to delineate the hydrogeological structures near monitoring wells in coastal areas.

해수침투 우려지역에서 단일 시추공을 이용한 전기비저항탐사 적용

  • 김진호;송성호;용환호;정형재;우명하
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.528-531
    • /
    • 2003
  • 안산시 단원구 대부동, 보령시 청소면 장곡리와 서천군 비인면 선도리의 해안가 4곳에서 전기비저항 탐사를 이용하여 해수침투 조사용 관측정 주변의 대수층구조와 해수침투여부를 파악하고자 하였다. 공내수의 심도별 전기전도도를 확인 해본 결과, 4개의 조사공에서 180-48,000$\mu$S/cm의 각기 다른 값을 보였으며, 전기비저항 검층의 결과에서는 16인치 Short-Normal 검층 0.5-19.28$\Omega$m, 64인치 Long-Normal 검층 1.36-47.45$\Omega$m 그리고 Lateral 검층에서는 0.16-6.69$\Omega$m의 값의 분포를 보였다. 이를 통해 해수에 의해 지하수 및 주변 지질이 완전히 오염된 관측정과 우려되거나 아직 해수침투가 일어나지 않은 관측정을 구분할 수가 있었다. 또한 시추공-지표간 토모그래피를 통해 관측정 주변의 개략적인 수리지질 구조도 파악할 수 있었다.

  • PDF

낙동강변 충적층 시추자료와 지구물리탐사자료의 연관성

  • Ham, Se-Yeong;Hwang, Hak-Su;Kim, Hyeong-Su;Jeong, Jae-Yeol;Moon, Chang-Gyu;Cha, Yong-Hun;Jang, Seong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.552-556
    • /
    • 2003
  • 창원시 대산면 갈전리의 강변여과수 취수지역의 8개의 시추공의 시추지료로부터 파악된 지하지질과 물리탐사자료를 비교하여 둘 간의 연관성을 검토하였다. 본 연구에서는 이미 얻어진 시추공 자료와 비교ㆍ검토하기 위하여 지구물리탐사를 실시하였다. 수행된 지구물리탐사는 쌍극자배열 전기비저항 수평탐사, 슐럼버져법배열 전기비저항 수직탐사, 지하투과레이다탐사이다. 전기비저항 수평탐사에 의하면 저비저항치의 두께는 낙동강변에 가까울수록 두꺼워지는 경향성을 보이고 있다. 전기비저항 수직탐사 결과는 시추자료와 비교적 잘 일치하고 있으며 지표로부터 세립질 모래층, 중립질 모래층, 세립질 모래층의 구분이 수직탐사 결과에서 잘 나타나고 있다. 또한 GPR탐사와 전기비저항 수직탐사 결과에 의하면, 지하수면은 6m 부근에 위치하고 있음을 알 수 있다.

  • PDF

Integrated Interpretation of ERT Data from the Mineralized Zone in Geumpung Mine (금풍광산 광화대에 대한 전기비저항 토모그래피탐사 자료의 복합해석)

  • Jung, Yeon-Ho;Byun, Joong-Moo
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.322-331
    • /
    • 2007
  • In this study, electrical resistivity tomography (ERT) were conducted to find the mineralized zone at the Geumpung mine in Dojeon-ri, Susan-myeon, Jecheon-si, Chungcheongbuk-do. The deviation of the inclined borehole was measured to obtain the exact positions of the electrodes for correcting apparent resistivity values from ERT. Geophysical loggings such as resistivity and natural gamma were conducted to obtain the properties of the material near the borehole. Measurements of the physical properties of the cores, such as porosity, water content, density, susceptibility, resistivity were performed to analyze the correlation between physical properties and resistivity. Grade analysis for core sample was also conducted to identify relationship between grade and resistivity. Rock property analysis shows that the resistivity is more dominated by susceptibility and grade than by porosity and water content in the mineralized zone. The results of ERT are well consistent with geophysical logging data and geologic column. So ERT is powerful method to identify conductive mineralized zone.

FEM Electrical Resistivity Modeling in Cylindrical Coordinates (원통 좌표계에서의 전기비저항 유한요소 모델링)

  • Choi Wonseok;Kim Jung-Ho;Park KwonGyu;Kim Hak-Soo;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.3
    • /
    • pp.206-216
    • /
    • 2002
  • The finite element method (FEM), a powerful numerical modeling tool for solving various engineering problems, is frequently applied to three-dimensional (3-D) modeling thanks to its capability of discretizing and simulating the shape of model with finite number of elements. Considering the accuracy of the solution and computing time in modeling of engineering problems, it is preferable to construct physical continuity and simplify mesh system. Although there exist systematic mesh generation systems for arbitrary shaped model, it is hard to model a simple cylinder in terms of 3-D coordinate system especially in the vicinity of the central axis. In this study I adopt cylindrical coordinate system for modeling the 3-D model space and define the origin of the coordinates with mathematically clear coordinate transformation. Since we can simulate the whole space with hexahedral elements, the cylindrical coordinate system is effective in handling the 3-D model structure. The 3-D do resistivity modeling scheme developed in this study provides basie principle for borehole-to-surface resistivity survey, which can be a useful tool for the application to environmental problem.

Resistivity Imaging Using Borehole Electrical Resistivity Tomography: A Case of Land Subsidence in Karst Area Due to the Excessive Groundwater Withdrawal (시추공 전기비저항 토모그래피를 이용한 비저항 영상화: 과잉취수에 의한 석회암 지반침하 지역 사례)

  • Song, Sung-Ho;Lee, Gyu-Sang;Um, Jae-Youn;Suh, Jung-Jin
    • Journal of the Korean earth science society
    • /
    • v.32 no.6
    • /
    • pp.537-547
    • /
    • 2011
  • Electrical resistivity tomography surveys using boreholes were applied to reveal the cause of a catastrophic land subsidence accompanied by the excessive groundwater withdrawal in urban karst area and to map the connectivity of disseminated cavities over the study area. In order to understand the hydrogeological characteristics, resistivity using exsitu core samples, groundwater level for five boreholes, and hydraulic conductivity using slug test were measured. The hydraulic conductivity variation ranging from 0.8 to $9.3{\times}10^{-4}\;cm/s$ for five boreholes and a gentle slope of groundwater level indicated that there is no significant characteristics of hydraulic heterogeneity. Core samples of the lime-silicated rock were classified as three groups including cracked, weathered, and fresh and measured the resistivity values ranged from 103 to 161, 218 to 277, and 597 to 662 ohm-m, respectively. Drilling results that showed the cavity filled with clay materials and tomogram for this region indicated resistivity value lower than 50 ohm-m. From the inverted resistivity results for each section with five boreholes, cavity and fractured layer were distributed along the depth between 10 and 20 m overall area and cavities ranging from 4 to 6 m filled with clay materials.

Application of SP Monitoring in the Pohang Geothermal Field (포항 지열 개발지역에서의 SP 장기 관측)

  • Lim Seong Keun;Lee Tae Jong;Song Yoonho;Song Sung-Ho;Yasukawa Kasumi;Cho Byong Wook;Song Young Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.164-173
    • /
    • 2004
  • To delineate geothermal water movement at the Pohang geothermal development site, Self-Potential (SP) survey and monitoring were carried out during pumping tests. Before drilling, background SP data have been gathered to figure out overall potential distribution of the site. The pumping test was performed in two separate periods: 24 hours in December 2003 and 72 hours in March 2004. SP monitoring started several days before the pumping tests with a 128-channel automatic recording system. The background SP survey showed a clear positive anomaly at the northern part of the boreholes, which may be interpreted as an up-flow Bone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. The first and second SP monitoring during the pumping tests performed to figure out the fluid flow in the geothermal reservoir but it was not easy to see clear variations of SP due to pumping and pumping stop. Since the area is covered by some 360 m-thick tertiary sediments with very low electrical resistivity (less than 10 ohm-m), the electrokinetic potential due to deep groundwater flow resulted in being seriously attenuated on the surface. However, when we compared the variation of SP with that of groundwater level and temperature of pumping water, we could identify some areas responsible to the pumping. Dominant SP changes are observed in the south-west part of the boreholes during both the preliminary and long-term pumping periods, where 3-D magnetotelluric survey showed low-resistivity anomaly at the depth of $600m\~1,000m$. Overall analysis suggests that there exist hydraulic connection through the southwestern part to the pumping well.

Analysis of Characteristics using Geotechnical Investigation on the Slow-moving Landslides in the Pohang-si Area (포항지역 땅밀림지의 지반조사를 통한 땅밀림 특성 분석)

  • Lee, Moon-Se;Park, Jae-Hyeon;Park, Yunseong
    • Journal of Korean Society of Forest Science
    • /
    • v.108 no.2
    • /
    • pp.233-240
    • /
    • 2019
  • The aim of this study was to provide basic data that could identify and help prevent a slow-moving landslide using an analysis of the relationship between below-ground characteristics and water from three slow-moving landslide areas in Pohang, Gyeongsangbuk-do, South Korea. Surface surveys, resistivity, seismic exploration, well logging, and boring surveys were conducted in the three areas. The main direction of discontinuous surface was matched with the slope direction of the three landslides. The results indicatedthat slow-moving landslides might occur in the direction of the slope. Underground water was distributed within the crush zones within the three landslide areas and flowed along the tensile cracks. There was a significant difference (p<0.01) between the mean angle of the tensile cracks and that of the underground waterflow (p=0.8019). These results indicated that the progress of a slow-moving landslide can be forecast by monitoring the location and flow of underground water within a known slow-moving landslide area.