• Title/Summary/Keyword: 시준

Search Result 83, Processing Time 0.019 seconds

Simultaneous Measurement of Thickness and Refractive Index of Transparent Material Using a Collimated Beam Having a Finite Radius (유한 반경의 시준 광속을 이용한 투명 매질의 두께와 굴절률의 동시 측정)

  • Park, Dae-Seo;O, Beom-Hoan;Park, Se-Geun;Lee, El-Hang;Lee, Seung-Gol
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.1
    • /
    • pp.29-33
    • /
    • 2009
  • We propose a new measuring technique based on optical low-coherence reflectometry that enables us to determine the refractive index and the geometrical thickness of a transparent sample by one-time scanning only. By passing a collimated beam having a finite size through the edge of the sample, the refractive index and the geometrical thickness can be determined simultaneously from the comparison of interferograms generated by two kinds of reflected beams. In this study, a refractive index could be determined with the accuracy of $10^{-3}$, and its accuracy would be enhanced by using a more precise translator and a thicker sample.

Application of the New Technology for an Efficient Cadastral Re-survey Project (지적재조사사업의 효율화를 위한 신 기술 적용 방안)

  • Hong, Sung-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6196-6203
    • /
    • 2013
  • This study examined cadastral surveying technology regulated under the "Special Law for the cadastral surveying", and analyzed the related surveying methods currently used. Based on the analysis, this study suggested the efficient application plan future cadastral surveying projects. The new technologies analyzed were GNSS, GPS RTK, Network RTK, GPS Augmentation System, and the mobile and auto sighting TS. As a result of the analysis, this study suggests that if a receiving technology is possible for the integrated receiving of GPS/GLONASS/Galileo systems, both the accuracy of location determination could be enhanced and stable data could be obtained. The Network RTK technology may solve the constraint receiving factors of satellite information in the long term if a GPS Augmentation System is used. Finally, mobile and auto sighting TS technologies can reduce the personnel factors, but can be applied after the offset problem is overcome.

A Study on Alignment Measurement and Compensation for Spacecraft Sensors (위성 탑재 센서의 정렬 측정 및 보정에 관한 연구)

  • Lee Byoung-Gi;Kim Young-Youn;Yoon Yong-Sik
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.537-540
    • /
    • 2005
  • The attitude control, sensors and camera installed on the spacecraft should be located according to the system alignment requirement. The alignment measurement requirement accuracy for the sensors should be below $\pm$0.1. Therefore, Alignment Measurement System which is combined theodolite, Rotating table and digital inclinometer etc., should be used. As the measurement accuracy is required very precise, the appropriate measurement procedure and alignment angle measurement, calculation and shimming work should is accomplished. Consequently, this paper is accomplished the works to align the measurement requirement accuracy throughout alignment measurement and shimming work of installed module and sensor

  • PDF

A Study on Spacecraft Alignment Measurement with Theodolite (데오도라이트를 이용한 위성체 얼라인먼트 측정에 관한 연구)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.64-70
    • /
    • 2003
  • A measurement of spacecraft alignment is an important process of spacecraft assembly, integration and test because it is necessary that a ground station controls the precise positions of on-orbit spacecraft by using the alignment data of attitude orbit control sensors(AOCS) on spacecraft. In addition, accuracy of spacecraft alignment requirement is about $0.1^{\circ}$~$0.7^{\circ}$. The spacecraft alignment is measured by autocollimation of theodolite. This paper describes the measurement principle and method of spacecraft alignment. The result shows that all of the AOCS on the spacecraft are aligned within the tolerance required through the alignment measurement.

Surface measurement using Confocal principle (공초점 원리를 이용한 표면 현상 측정)

  • 송대호;유원제;강영준;김경석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.51-54
    • /
    • 2000
  • The traditional surface measuring method using confocal principle requires much time to measure an object surface since it is a scanning tool. In this paper, the upgraded confocal microscope is introduced. It is also a scanning tool but it requires 2D-scanning while the traditional one requires 3D-scanning. It means the time for measuring is considerably reduced. In addition, the measuring system is configured to increase the efficiency of beam. He-Ne laser whose frequency is 632.8nm is used for the laser source. An example of measuring result through the upgraded confocal microscope is showed.

  • PDF

Null alignment system of the optical beam director (광집속장치의 광학정렬을 위한 null 광학계)

  • 김연수;김현숙;김현규
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.254-257
    • /
    • 2004
  • A null optical system for monitoring the alignment of the optical beam director is proposed instead of the conventional autocollimator alignment system. A null optical system for the optical beam director of aperture 30 cm is designed and its performance is analysed.

Thermally Expanded Core Fibers for Hybrid Fiber Components (광섬유 복합 소자를 위한 열확장코어 광섬유)

  • 김진하;김병윤
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.304-310
    • /
    • 1994
  • The use of thermally expanded core (TEe) fibers fabricated by thermal diffusion of dopants such as $GeO_{2}$ in hybrid fiber components has an advantage of eliminating lenses for collimation and focusing. An electric furnace is fabricated to heat the fibers locally for the core expansion. We observed an expansion of the mode size at $1.3\mu\textrm{m}$ wavelength by 27% after treating a section of single mode optical fiber at $1250^{\circ}C$ for 10 hours. hours.

  • PDF

A Study on Measurement Accuracy of Theodolite System( I ) - A Measurement Accuracy According to a Theodolite Collimations Distance (데오도라이트 시스템의 측정 정확도에 대한 연구( I ) - 데오도라이트 시준 거리에 따른 측정 정확도)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.2
    • /
    • pp.61-68
    • /
    • 2004
  • A non-contact precision measurement system is a theodolite system, a laser tacker and a photogrammetry system etc. Nowadays, the system reaches to a limit of measurement accuracy required from industrial product of middle and large scale. The one of the solutions for this problem is to maximize the accuracy of the existing measurement system. According to it we performed the study far a measurement accuracy of theodolite system when the distance between two theodolites is changed 1m to 5m. We could blow that the changes of distance affect the measurement accuracy of theodolite system and that the maximum measurement accuracy is $\pm$ 0.02 mm on theodolite distance 3∼4 m.

Inhomogeneous amplitude modulation effects on the MTF of binocular objective (비균일 진폭변조가 쌍안경 대물경의 MTF에 미치는 영향)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.102-106
    • /
    • 1999
  • In this study, inhomogeneous amplitude modulation effects on the imaging performance a lens system are expermentally investigated by measuring the diffraction OTF. The lens under the test is a binocular objective made in Korea. Inhomogeneous amplitude modulation is carried out by positioning the modulator cross contacted to the lens under test which is illuminated by collimated light beam. The aberration characteristics of the lens under test are examined by caculating the ray-fan through finite ray tracing. The MTFs of the lens illuminated by the homogeneous and inhomogeneous light beam are measured on the Gaussian image plane and compared with one another.

  • PDF

Liquid Immersion Method for Determining the Refractive Index of a Lens by using the Murty Shearing Interferometer (층밀리기 간섭계를 이용한 렌즈 굴절률의 비파괴적 측정)

  • 이윤우;조현모;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 1991
  • A nondestructive technique for measuring the refractive index of a simple lens is described. The shearing interferornetric technique is used for determining the focal length of a lens by immersing it in various liquids. The lens itself acts as autocollimator and decollimator. An equation for the defocusing error has been theoretically deduced and experimentally verified. The wave aberration has also been investigated for the different values of the focal length.

  • PDF