• Title/Summary/Keyword: 시운전 시험

Search Result 162, Processing Time 0.028 seconds

Development of Multi-purpose Marine Wastes Cleaning Systems for the Shallow Waters(PART II : System Development and Performance Evaluation) (천수용 다기능 해양폐기물 수거시스템 개발(PART II : 시스템 구성 및 성능시험))

  • Cho Yong-Jin;Moon Il-Sung;Shin Myung-Soo;Yu Jeong-Seok;Kang Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.2
    • /
    • pp.62-67
    • /
    • 2002
  • This paper - following 'Development of multi-purpose marine waste cleaning systems for the shallow waters (Part I : preliminary conceptual design)'- describes on the system development and the sea trial performance evaluation(Cho[2003]). The multi-functional seabed waste collecting system and the towing hook system were developed. The maximum working depth of these systems are 15 and 100 meters, respectively(MOMAF[2001]). For the multi-purpose use to collect the marine waste, this system contains floating waste collecting device for the waste on seawater and remained waste collecting device for the waste on seabed, while steel wire cutting system is added for higher efficiency In order to evaluate the system performance, the prototype of multi-functional system was constructed and the sea trial test at shallow water were carried out. As a result, this system operated well with safe and without any interaction so that the developed systems are practicable and applicable.

  • PDF

Study on the Correction Method of Ice Strength and Thickness Applied to the Sea Trial Condition Based on the Ice Model Test Results (빙두께 및 강도 보정기법을 이용한 모형시험결과의 실선시운전 적용연구)

  • Lee, Seung-Ki;Kim, Moon-Chan;Lee, Won-Jun;Kim, Hyun-Soo;Lee, Chun-Ju
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.5
    • /
    • pp.457-464
    • /
    • 2011
  • This paper deal with the validation of correction method of ice strength and thickness to the sea trial condition based on the ice model test results. It is very difficult to conduct the model test corresponding to the sea trial condition exactly. In addition, the available sea trial data is not sufficient for the validation of correction method. In the present study, the model test results of Terry-Fox ice breker have been used to compare the corrected results of sea trial test by varying its thickness and strength of model ice. The HSVA and ITTC methods have been applied to the present comparisions and the required power has been also validated by using the HSVA method. There are rather good agreement between the sea trial result and model test corrected by the HSVA and ITTC method. The more comparisons are expected to be carried out in near future.

Field Application of H-Bridge Multi-level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan (200MW 석탄화력 순환 유동층 보일러 이차공기송풍기용 H-브릿지 멀티레벨 인버터 현장적용)

  • Kim, Bong-Suck;Ryu, Ho-Seon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.424-431
    • /
    • 2007
  • This thesis proposed H-Bridge Multi-Level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan in 200MW thermal power plant. The adjustable speed drive systems improve the efficiency in lightly load condition and extend the life span of motor by limiting the over current at starting. H-Bridge Multi-level Inverter is composed of the several series low voltage power cell inverters, which have the independent isolated do link, in each phase. KEPRI(Korea Electric Power Research Institute) has successfully completed to develop, install, and commission H-Bridge Multi-level Inverter(6.6kV, 1MVA). This thesis gives a full detail about H-Bridge Multi-level Inverter, proposed boiler DCS(Distributed Control System) logic, and commissioning test result.

Study on the Radioactive Liquid Waste Treatment of Cooling and Decompression Process of Spent Fuel Assembly Cask (사용후핵연료 집합체 캐스크 감온, 감압 공정의 방사성 액체폐기물 처리 대한 연구)

  • 손영준;전용범;김은가;엄성호;권형문;민덕기;양송열;이은표;이형권
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.83-89
    • /
    • 2003
  • A temperature- and pressure-reducing process is utilized to handle the spent fuel assembly in the post-irradiation examination facility. This process includes three separated unit processes. First one is the decontamination process to clean the spent fuel assembly casks. The second process is the temperature-reducing process to reduce the temperature elevated by decay process in the spent fuel assembly. The third process is the filtration process to remove insoluble particles existed in the casks using filters. Up-to-date technologies as well as practical theories related to the temperature- and pressure-reducing process is reviewed in this report. The test-operation process for various tests and the test results of the temperature- and pressure-reducing process for J-44 and K-23 spent fuel assemblies are also described in detail. This report must be effectively used for the normal operation of the facility with the awareness of unprecedented problems which could occur by continuing operation of the PIE facility.

  • PDF

A Modal Testing of Large Naval Vessel Using Main Gun Firing Test (주포 사격시험을 이용한 대형 함정의 모달테스트)

  • Park, Mi-You;Han, Hyung-Suk;Cho, Heung-Gi;Kim, Joong-Gil;Im, Dong-Been;Lee, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • The accurate results of finite element analysis are directly related to reliability FE model which is exactly describing dynamic characteristics of target structure. So, a model updating is necessary to establish reliable FE(Finite Element) model with a lot of experience and effort using modal testing. A large structure is too difficult to obtain the dynamic characteristics owing to its weight and size. In this work, using main gun firing test, modal testing was performed to obtain dynamic characteristics of large naval vessel, which is difficult to tap the general modal testing method. The result of experiment was considered its possibility and future plans.

A Study on the Ride Quality Enhancement of the High-speed Electric Multiple Unit (동력분산형 고속열차의 승차감 개선에 관한 연구)

  • Jeon, Chang-Sung;Kim, Sang-Soo;Kim, Seog-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.561-567
    • /
    • 2018
  • This study was carried out to improve the ride quality of high-speed electric multiple unit. Through dynamic analysis of the HEMU-430X, the range of the equivalent conicity with a critical speed of 300 km/h was between 0.05 and 0.25. The initial adopted wheel profile of HEMU-430X was S1002. The equivalent conicity of S1002 with the mileage of more than 40,000 km was about 0.033 and it was confirmed that XP55 is more suitable for stable operation because XP55 has the equivalent conicity of over 0.061. In order to improve ride quality of high-speed electric multiple unit, the change of installation angle of the yaw damper was suggested from $7.35^{\circ}$ to $0^{\circ}$. From sensitivity analysis and optimization, the air spring lateral and vertical stiffness was suggested to be reduced by 30% and the secondary vertical and lateral damper damping coefficient was increased by 50%. By applying this, it was expected that the car body acceleration could be improved by about 20% on average. The HEMU-430X's yaw damper installation angle was changed to $0^{\circ}$ and the damping coefficient of the lateral damper was increased by 30%. When the test run was carried out at the speed of 300 km/h on the Kyungbu high-speed line, the vehicle lateral acceleration had improved by 34.3%. The effect of additional improvement measures proposed in this paper will be tested in the on track test. The riding quality improvement process used in this study can be used to solve ride quality problems that can occur in commercial operation of high-speed electric multiple unit in the future.

A Study on Loose Part Monitoring System in Nuclear Power Plant Based on Neural Network (원전 금속파편시스템에 신경회로망 적용연구)

  • Kim, Jung-Soo;Hwang, In-Koo;Kim, Jung-Tak;Moon, Byung-Soo;Lyou, Joon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.05a
    • /
    • pp.227-230
    • /
    • 2002
  • The Loose Part Monitoring System(LPMS) has been designed to detect, locate and evaluate detached or loosened parts and foreign objects in the reactor coolant system. In this paper, at first, we presents an application of the back propagation neural network. At the preprocessing step, the moving window average filter is adopted to reject the low frequency background noise components. And then, extracting the acoustic signature such as Starting point of impact signal, Rising time, Half period, and Global time, they are used as the inputs to neural network. Secondly, we applied the neural network algorithm to LPMS in order to estimate the mass of loose parts. We trained the impact test data of YGN3 using the backpropagation method. The input parameter for training is Rising Time, Half Period, Maximum amplitude. The result showed that the neural network would be applied to LPMS. Also, applying the neural network to the Practical false alarm data during startup and impact test signal at nuclear power Plant, the false alarms are reduced effectively. 1.

  • PDF

A study on development of a dual driven ship berthing/deberthing system using magnetic gear (마그네틱 기어를 이용한 듀얼 구동식 선박 접이안 시스템 개발에 관한 연구)

  • Kang, Min-Su;Kim, Byong-Kuk;Kim, Hyen-Woo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.98-99
    • /
    • 2016
  • The aim of study is to develop a dual driven ship berthing/deberthing system with $360^{\circ}$ steerability. A large ship used bow thruster, side thruster and pod propulsor etc. when approaching to a pier. But as marine leisure boats become large-scaled, the number of accidents is recently increasing what caused a ship to crash into a ship and a ship to crash into mooring facilities during berthing/deberthing on a marina. To solve the problem, the control responsiveness of a joystick connected with two motors and a propeller was checked and torque was increased by the electromagnetic design of magnetic gear. A sea trial test was carried out to investigate a performance of the developed system in the real sea.

  • PDF

Neutron Noise Analysis for PWR Core Motion Monitoring (중성자 잡음해석에 의한 PWR 노심 운동상태 감시)

  • Yun, Won-Young;Koh, Byung-Jun;Park, In-Yong;No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.253-264
    • /
    • 1988
  • Our experience of neutron noise analysis in French-type 900 MWe pressurized water reactor (PWR) is presented. Neutron noise analysis is based on the technique of interpreting the signal fluctuations of ex-core detectors caused by core reactivity changes and neutron attenuation due to lateral core motion. It also provides advantages over deterministic dynamic-testing techniques because existing plant instrumentation can be utilized and normal operation of the plant is not disturbed. The data of this paper were obtained in the ULJIN unit 1 reactor during the start-up test period and the statistical descriptors, useful for our purpose, are power spectral density (PSD), coherence function (CF), and phase difference between detectors. It is found that core support barrel (CSB) motions induced by coolant flow forces and pressure pulsations in a reactor vessel were indentified around 8 Hz of frequency.

  • PDF

Methods of Ensuring Safety for Integrated Fire Protection Shutters at Elementary and Middle Schools (초등학교 및 중학교의 일체형 셔터 안전성 확보 방안)

  • Youn, Hae-Kwon
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.36-45
    • /
    • 2016
  • Integral fire shutters are installed indiscriminately, regardless of evacuation. There is always the risk of an accident because integral shutters are applied mainly to corridors, passages, and stairs of schools This study evaluated the problem of integral shutter's entrance, evacuation, construction management, and maintenance control through a fire shutter accident case, including present condition of fire shutter installed at school of Okgil, Bucheon and Dongtan, Hwaseong. The results suggest that emergency lighting or signs for passage be set up to check location of entrance easily and install obstruction sensors at fire shutter to reduce life damage. In addition, the number of efficiency tests of fire shutters should be increased by running a trial test monthly or weekly to maintain the performance of fire shutter. Schools need to install a fire shutter- applied sprinkler at the entire floor.