• 제목/요약/키워드: 시설물 현장연구

Search Result 364, Processing Time 0.03 seconds

A Study on the Evaluation Method of Level of Service in Transfer Walking Facilities (환승 보행시설의 서비스수준 평가방법에 관한 연구)

  • Yun, Tae-Gwan;Lee, Yeong-In
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.1
    • /
    • pp.143-156
    • /
    • 2010
  • The walking is very important because of its environment friendly and low accident rate, and transferring is also important as increasing public transportation uses. Facilities for transferring such as transfer path in Sadang station and internal stairways in Sindorim station are the object of this paper. Using preexistence methodology for Level of Service is not appropriate to transferring facilities because they are occurred only when the train arrive that station. To solve this problem, this paper uses queuing theory and utilization factor. In result, we can get Level of Service which can simulate real situation of the facilities by using new methodology which introduce by this paper. Also it reveals that preexistence methodology cannot simulate real phenomenon in transferring center.

A Case Study on Establishing Test Bed of Slope Structure Measurement System using Optic Fiber Sensor (광섬유센서를 이용한 사면시설물 계측시스템 시범구축 사례 연구)

  • Kwon, O-Il;Baek, Yong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1026-1031
    • /
    • 2009
  • 21세기 대한민국은 지반분야에 있어서 과거 건설위주의 발전에서 유지관리의 중요성이 대두되는 시대로 변모하였다. 특히 이상기후에 의한 집중호우 발생이 빈번해진 상황에서 외부조건에 직접적으로 노출되어있는 사면구조물은 타 지반구조물보다 상대적으로 관리의 필요성이 더 높다. 사면의 유지관리 방법 중에서도 계측에 의한 상시 모니터링 시스템 구축 관련 기술이 주목을 받고 있으며, 장기적인 시스템 운용 측면에서 내구성이 우수한 광섬유 재료를 이용한 계측 시스템 개발이 국가적 지원을 받으며 연구가 활발히 진행 중에 있다. 본 연구는 암반사면의 균열부에 설치하여 미세한 거동을 측정할 수 있는 광섬유 정밀 계측 시스템을 개발하고, 실제 사면 현장에 시범 구축한 사례를 요약한 것이다. 영동고속도로 원주지사 관내에 있는 암반사면을 대상으로 총 6개의 센서를 변위발생 가능성이 높은 균열부에 설치하였다. 계측데이터의 수집과 전송을 위하여 사면 하단부에 컨트롤박스를 설치하고 데이터로거, 운용시스템, 유선네트워크 시스템을 구축하였다. 설정된 주기별로 취득되는 계측데이터는 우선적으로 현장에서 저장되고, 사무실에서도 원격으로 제어할 수 있는 시스템을 시범적으로 구축하여 운용중에 있다. 향후 계측 시스템의 센서부, 데이터로거, 운용프로그램 등을 추가 연구를 통하여 개선하고 현장에 반영하는 과정을 반복함으로써 사면 시설물의 유지관리에 최적의 시스템을 개발 및 구축하는 것이 본 연구의 최종적인 목표이다.

  • PDF

Risk Analysis on Inundation of SOC Facilities under Climate Change (기후변화에 따른 SOC구조물의 외부/내부침수 위험도 분석)

  • Kim, Beom Jin;Keum, Ho Jun;Lee, Jae Yeong;Kim, Hyun Il;Han, Kun Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.52-52
    • /
    • 2019
  • 최근 국가시설물에서는 2000년대 이후 집중호우 등으로 인한 대상 부지 내의 홍수 발생 시 주요시설물에 기능 마비가 발생할 수 있고, 궁극적으로는 대규모 사고로 이어질 수 있기 때문에 외부침수에 대비할 수 있는 위험도 분석이 필요하다. 대상 부지에서의 외부침수의 원인으로서는 LIP(Local Intensive Precipitation)에 의한 홍수 발생조건, 인근에 댐, 제방 등이 위치한 경우 이들 시설물의 붕괴에 따른 홍수류의 원전 유입, 지진해일/폭풍해일에 의한 바다로부터의 홍수 유입 등이 대표적인 예이다. 따라서 대상 부지 및 그 SOC시설물의 안전도를 높은 수준에서 관리하기 위해서는 극한홍수가 유입될 때 침수심, 침수유속, 침수시간, 침수강도 등의 재해도를 분석하여야하고, 이들 SOC시설물의 취약도 평가를 실시하고 재해도와 취약도를 결합한 연계분석을 통하여 위험도를 재평가하여야 한다. 본 연구에서는 기존 기후변화를 고려한 외부침수 위험도 분석 결과를 바탕으로 대상 부지 내의 내부침수 위험도 분석을 실시하였다. 위험도 분석을 실시하기 위해 현장답사를 통해 물이 외부에서 내부로 유입 가능한 침수패스 경로를 파악하고, 출입문 위치와 창문의 높이, 출입문의 틈간격 및 높이를 파악하였다. 현장답사를 토대로 침수구역을 선정하였다. 침수구역 선정시 대침수구역과 소침수구역 중요기기들이 위치한 구역을 바탕으로 선정하였고, 이를 바탕으로 2차원 침수 해석을 실시하여 각 구역별로 시간대별 침수가능 높이를 산정하였다. 또한 각 구역별 중요기기의 임계높이를 산정하고, 이를 분석된 최대 침수심과 비교하여 각 구역별 침수에 취약한 구역을 산정하였다. 본 연구결과의 바탕으로 사회기반 시설에 대한 보호 및 홍수피해 예방으로 인한 사회비용 절감이 가능하고, 주요시설물의 SSC별 방재대책을 수립하고, 단계별 저감대책을 제시하여 위험도 경감을 위한 대비책을 마련이 가능할 것 이라고 판단된다.

  • PDF

Extraction of the Road Facility Information Using Digital Ortho-Image (정사투영영상을 활용한 도로시설 정보 추출)

  • 함창학;김원대
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.19 no.3
    • /
    • pp.219-228
    • /
    • 2001
  • The research into the field of managing urban utility information (such as gas pipes, power line, telecommunication utilities) is growing ever more important as the efficient management of social infra-structure gets higher and also with the fast technological progress made in nationwide scale of geo-spatial information systems. This research is focused on the collection of street utilities information in urban areas using aerial ortho-images. Until now this has been carried out by on site investigation and ground surveying methods. The result of this research shows that the geometric accuracy was obtainable within 12 cm referenced to 1/1,000 digital map. It was also possible to collect the street utilities which were described in the digital map as well as other information which were not.

  • PDF

Application for Disaster Prediction of Reservoir Dam Wireless Sensor Network System based on Field Trial Construction (현장 시험시공을 통한 저수지 댐의 재해예측 무선센서 네트워크 시스템 적용성 평가)

  • Yoo, Chanho;Kim, Seungwook;Baek, Seungcheol;Na, Gihyuk;You, Kwangho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.1
    • /
    • pp.19-25
    • /
    • 2019
  • In this present study, to evaluate the applicability of the monitoring system of the entire reservoir dam facility using the wireless sensor network system and a section representative of the domestic reservoir dam was selected as the test bed site and to operated a system that can evaluate the condition of the facility at the real time with monitoring. In order to set up a wireless sensor network system, the system assessment of present state was carried out for confirmation the risk factors and the limit values of the risk factors in limit state were calculated. The type and position of the sensor to be measured in the field were determined by setting the measurement items suitable for the hazardous area and the risk factor. In this paper, we evaluated the feasibility of the system by monitoring and constructing a wireless sensor network system in a field for a fill dam that can represent a domestic reservoir dam. Applicability evaluation was verified by comparing directly with the measurement of partial concentration method which is the measurement management technology of the dam.

Safety Management of Steel Pipe Scaffold using UAV (무인항공기(UAV)를 활용한 건설현장 가시설물 안전관리)

  • Jun, Byong-Hee;Kim, Nam-Gyun;Jun, Kyo-Won;Choi, Bong-Jin
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.3
    • /
    • pp.59-67
    • /
    • 2019
  • In this study, the UAV (Unmammed Aerial Vehicle) was applied for the photogrammetry of the construction site and the safety management of steel pipe scaffold. The research site is a temporary facility for building reinforcement on Samcheok Campus of Kangwon National University. The installation condition of the steel pipe scaffold was investigated, and the pillar distance, the beam distance and the wale distance were surveyed. As a result, it was found that the beam distance of the scaffold in the longitudinal direction was in good agreement with the standard, but the pillar distance and the wale distance were found to be less than the standard. Three-dimensional data can be used in drone shooting to enable three-dimensional measurement, so that it is possible to measure facilities hidden or located inside other facilities. Through the drone shooting, the condition of the site can be quickly recorded and the surveying can be carried out without interfering with the work of the field personnel. Although the installation of the temporary structure must be strictly observed to ensure the safety of the workers, it is found that the installation standards are still neglected in the field. In order to prevent this practice, it was thought that the legal system should be supplemented so that it could be checked periodically by using UAV in the field process management.

Applications of Mobile GIS Solution for Utility Management (시설물관리를 위한 Mobile GIS 솔루션 활용)

  • 한승희;이용욱;이형석
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.1
    • /
    • pp.69-75
    • /
    • 2002
  • The important issues of facility database management in GIS are to collect up-to-date information and to update information in accordance with new-establishment, repair and replacement of the facilities. Therefore, it is necessary to develop a system which has capability of monitoring facilities as well as managing database efficiently. The purpose of this study is to propose possibility of implementation of mobile GIS solution for the facility management. In order to achieve the goal, to process existing digital maps and to receive on-site information through the wireless communication service are required. In addition, the system is required to process spatial information obtained by GPS and digital photogrammetric technique with real-time updating database in server. The system increases efficiency both in work flow and monitoring for facility management by providing optimal routing information to the sites and real-time two-way communication using VoIP(Voice over Internet Protocol). The system is expected to perform real-time database management effectively. In consequence, the system could appropriately response on-site situations in various practical applications. The proposed technology could contribute to improve nation's leading-edge technology.

A Study on Status and Accuracy of Underground Facilities Maps (지하시설물도 현황 및 정확도 분석에 관한 연구)

  • Lee, Yong-Wook;Heo, Min;Lee, Jae-One;Bae, Kyoung-Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.3
    • /
    • pp.223-230
    • /
    • 2007
  • As the centralization of city, underground facilities is increasing and being more important. Although the importance of underground facilities map has been emphasized, there were many accidents related underground facilities. The inaccuracy of existing data and the carelessness of management caused many accidents. It is very important to update and to have high quality accuracy of underground facilities maps. But the underground facilities maps are mapped and updated by each institutes. So it is difficult to verify the accuracy of the data. In this study, Field Test is performed to analyze the horizontal accuracy of existing maps using Electromegnetic Induction Method, Total Station and GPS. Surveying of underground facilities in Seoul was performed for 6 institutes of underground facilities during 3 years. The aim of this study is to verify the horizontal accuracy of data and to improve the accuracy of underground facility maps. As the result of analysis, the horizontal accuracy of 6 underground facilities management institutes is 73 cm(2004), 78 cm(2005) and 75 cm(2006).

Percentile Approach of Water Level Management Criteria for Agricultural Reservoirs (Percentile을 이용한 농업용 저수지의 저수율 운영기준 산정)

  • Woo, Seung-Beom;Nam, Won-Ho;Lee, Hee-Jin;Choi, Eun-Hyuk;Lee, Gyu-Sang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.179-179
    • /
    • 2021
  • 가뭄은 농작물 수확량 및 농업생산시스템에 영향을 주는 등 농업분야의 주요 문제이며 이는 피해를 야기하므로 농업가뭄의 대안 마련 및 모니터링이 필요한 실정이다. 농업현장에서의 용수공급의 경우 기상학적 가뭄이 발생하더라도 농업용 수리시설물에 의한 농업용수 공급이 가능하여 기상학적 가뭄과 농업현장에서 체감하는 가뭄은 상이하다. 따라서 농업가뭄 피해를 최소화하기 위해서는 농업현장에 직접적인 영향을 주는 농업용 수리시설물의 관리는 매우 중요하다. 본 연구에서는 국내 100만톤 이상의 농업용 저수지 중 시범지역을 선정하여 2017년의 일별 저수율을 정규화한 후 미국국립가뭄경감센터 (National Drought Mitigation Center, NDMC)에서 가뭄을 모니터링하는데 사용하는 Percentile을 활용하여 농업용 저수지의 관리기준을 제시하고자 한다. Percentile을 활용하여 저수율 기준을 관심, 주의, 경계, 심각 수준으로 분류하고 당해 저수율의 단계별 빈도를 파악하고자 한다. 그 후 표준강수지수(Standrad Precipitation Index, SPI)를 활용한 2017년 가뭄의 공간분포와 2017년 저수율 관리기준 빈도에 따른 공간분포를 구축하여 비교 분석 해보고자 한다. 본 연구는 농업가뭄 모니터링을 위한 정책 마련에 활용될 것으로 사료된다.

  • PDF

Facility Management using Ubiquitous Technology - Focused on Roadside Trees - (유비쿼터스 기술을 이용한 시설물 관리 - 가로수를 중심으로 -)

  • Kim, Eui-Myoung;Kang, Min-Soo;Lee, Jin-Young;Kim, Byoung-Hun;Kim, Ho-Zoon;Kim, In-Hyun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.4
    • /
    • pp.105-118
    • /
    • 2006
  • The existing facility management system is capable of managing two-dimensional and three-dimensional models that were driven from maps and registered documents. However, it is not capable to collect various fields data on a real time and operate the integrated systems. To supplement those obstacles, constructing a facility management system based on ubiquitous environment is needed. Therefore, this research has proposed the modified UFID(Unique Feature IDentifier), which is more suitable for the facility management by modifying management agency and serial codes system in the existing UFID. In addition, we established the procedures for ubiquitous environment based on facility management using proposed UFID. The feasibility of this research was assessed through case study focused on roadside trees. It is considered that the results can be applied to many other ubiquitous environments based on facility management.

  • PDF