• Title/Summary/Keyword: 시료환경 장치

Search Result 147, Processing Time 0.028 seconds

Assessment of Consolidation Properties Using Modified Oedometer for Radial Drainage Condition (개량형 수평배수 압밀시험 장치에 의한 압밀특성 평가)

  • Jeon, Jesung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.143-150
    • /
    • 2009
  • Material functions about effective stress, permeability, coefficient of consolidation and coefficient of volume change has important role to predict consolidation velocity and settlement of soft ground. Modified oedometer for radial drainage is adapted to find out material functions on laboratory tests. Undisturbed sample for laboratory tests were taken from construction sites of industrial complexes on southern coastal area which consists of upper dredged fill and lower original clay layer. For different drainage condition in consolidation process void ratio, effective stress, permeability, coefficient of consolidation and coefficient of volume change has been assessed with results of existing standard oedometer tests. It is worthwhile to note that consolidation material functions could be expressed as regression equation by Stark (2005), heterogeneity for permeability could be assessed from these relationships.

  • PDF

Analysis of digital monitoring of TOC using a spectrometer in river (하천에서의 분광측정기를 이용한 TOC 디지털 모니터링 분석 연구)

  • Soo Bin Yoon;Chang Hyun Lee;Ho Soo Lee;Ye Lim Park;Young Do Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.195-195
    • /
    • 2023
  • 유기물오염은 호수와 하천에서 가장 흔히 나타나는 오염의 형태이다. 개발도상국에서는 하수처리시설이나 생활용수처리시설에서 유기물이 처리되지 않아 수중의 유기물함량이 증가하여 피해가 나타난다. 물환경보전법에 따라 유기물질을 측정하는 지표에는 BOD, COD, TOC가 있다. 그 중 BOD, COD 측정은 절차가 복잡하고 오래 걸리며, 생물분해가 불가능하거나 유독물질이 존재하는 유기물질인 경우에는 낮은 결과 또는 측정이 불가능하다. 이러한 이유로 환경부에서는 TOC중심관리로 전환되고 있다. 대부분의 수질항목 측정의 경우 현장시료를 채취하여 실험실에서 분석하는 수분석을 이용한다. 하지만 수분석의 경우 인력이 많이 투입되고 분석수가 한정적이며, 정교한 과학 장치를 갖춘 전문 실험실을 필요로 한다. 반면에 TOC는 짧은 시간 내에 측정이 가능하고, 안정적인 산화로 유기물질 총량을 정확하게 측정이 가능하다. 또한 위해성 물질을 발생시키지 않는 친환경적 방법이라 환경오염 감시에 많이 활용된다. 본 연구에서 분광측정기 중 하나인 S-CAN을 통해 하천의 TOC분석을 진행하였다. 대상지는 안동에 위치한 하천실험센터와 금호강 진천천으로 S-CAN측정과 채취한 시료의 수분석 결과를 비교하였다. 이를 통해 TOC측정 및 기기에 대한 정확도분석을 실시하였다. 본 연구를 통해 S-CAN을 활용한 TOC중심의 수질모니터링하여 수질의 특성을 탐구하고, TOC기초연구를 통한 유기물오염도 지표로서 해석할 수 있다. 수분석 자료를 활용한 정확도 비교를 통해 하천 TOC센서 측정 적용에 대한 기초자료 제공과 측정기기의 현장적용성을 판단 할 수 있다. TOC측정 및 분석을 통해 유기물질량을 실시간으로 정확하게 측정하게 되면 수질관리 효율성이 높아지고, 하천에 유입되는 유기물질량과 농도를 정확하게 파악하여 실효성 있는 정책 수립 및 효율적인 수질관리를 할 수 있다.

  • PDF

Experimental Evaluation of an Analytical Method for Chlorofluorocarbons (CFSs) in Air and Water Using Gas Chromatography (가스 크로마토그래피를 이용한 대기와 물시료의 CFCs(chlorofluorocarbons) 분석법의 실험적 평가)

  • Koh, Dong-Chan;Choi, Beom-Kyu;Kim, Yong-Je
    • Economic and Environmental Geology
    • /
    • v.40 no.1 s.182
    • /
    • pp.129-140
    • /
    • 2007
  • CFC(CFC-12, CFC-11 and CFC-113) analytical system for air and water was constructed using a customized purge and trap extraction device and a gas chromatograph with an electron capture detector. Sampling methods of air and water for CFCs were also established. The analytical system was experimentally optimized to result in reproducibilities of triplicates less than 2% for current air samples and less than 5% for groundwater samples with CFC-12 concentration of 160 to 180 pg/kg, and verified with respect to the CFC system in USGS, which showed analytical results were in agreement within 10%. CFCs in air were monitored at three sites over 19-month period in the central part of South Korea, and the result indicates no significant local sources of CFCs in those areas. For groundwater in Jeju Island, CFCs were measured over a year with a two-month interval. The time-series data showed seasonal fluctuations which could be interpreted by the effect of recharge pulse derived from large amount of rainfall during monsoon period with a few month delay, which indicates high permeability of basaltic rocks in Jeju Island.

Analysis of Synthetic Fragrances (SFs) in Water Using Stir Bar Sorptive Extraction (SBSE) and GC-MS/MS (교반막대 추출법과 GC-MS/MS를 이용한 수중의 합성 향물질류 분석)

  • Seo, Chang-Dong;Son, Hee-Jong;Yoom, Hoon-Sik;Choi, Jin-Taek;Ryu, Dong-Choon;Kwon, Ki-Won;Jang, Seung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.387-395
    • /
    • 2014
  • A highly sensitive analytical method based on stir bar sorptive extraction (SBSE) technique and gas chromatography/tandem mass spectrometry (GC-MS/MS) has been developed, allowing the simultaneous multi-analyte determination of 11 synthetic fragrances (SFs) in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 40 mL of water sample at pH 3 and stirred at 1,100 rpm for 120 min. Other SBSE parameters (salt effect and presence of organic solvent) were optimised. The method shows good linearity (coefficients > 0.990) and reproducibility (RSD < 10.9%). The extraction efficiencies were above 83% for all the compounds. The limits of detections (LOD) and limits of quantification (LOQ) were 2.1~4.1 ng/L and 6.6~12.9 ng/L, respectively. The developed method offers the ability to detect 11 SFs at ultra-low concentration levels with only 40 mL of sample volume. Matrix effects in tap water, river water, wastewater treatment plant (WWTP) final effluent water and seawater were investigated and it was shown that the method is suitable for the analysis of trace level of 11 SFs. The method developed in the present study has the advantage of being rapid, simple, high-sensitive and both user and environmentally friendly.

Vapor Recognition Using Image Matching of Micro-Array Sensor Response from Portable Electronic Nose (휴대용 전자 후각 장치에서 다채널 마이크로 센서 신호의 영상 정합을 이용한 가스 인식)

  • Yang, Yoon-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.64-70
    • /
    • 2011
  • Portable artificial electronic nose (E-nose) system suffers from noisy fluctuation in surroundings such as temperature, vapor concentration, and gas flow, because its measuring condition is not controled precisely as in the laboratory. It is important to develop a simple and robust vapor recognition technique applicable to this uncontrolled measurement, especially for the portable measuring and diagnostic system which are expanding its area with the improvements in micro bio sensor technology. This study used a PDA-based portable E-nose to collect the uncontrolled vapor measurement signals, and applied the image matching algorithm developed in the previous study on the measured signal to verify its robustness and improved accuracy in portable vapor recognition. The results showed not only its consistent performance under noisy fluctuation in the portable measurement signal, but also an advanced recognition accuracy for 2 similar vapor species which have been hard to discriminate with the conventional maximum sensitivity feature extraction method. The proposed method can be easily applied to the data processing of the ubiquitous sensor network (USN) which are usually exposed to various operating conditions. Furthermore, it will greatly help to realize portable medical diagnostic and environment monitoring system with its robust performance and high accuracy.

Analysis of Odorous Sulfur compounds in Air by Solid Phase Microextraction (대기중의 악취성 황화물분석을 위한 SPME 분석법)

  • 허귀석;김대원;윤영경;정용순
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.343-344
    • /
    • 2000
  • 대기중의 황화합물 분석은 현행 우리나라 악취공정시험법에 고시되어 있으나 복잡한 농축장치를 필요로하고 조작법이 복잡하고 시간이 많이 소요된다. 특히 황화합물은 주요 악취물질로서 대기오염을 일으키고 있으며, 극미량에서(ppb) 악취를 발생시키는 악취물질임에도 불구하고 분석방법 및 정확도에 많은 문제점을 갖고 있다. 본 연구에서는 황화물 시료농축이 간단하며, 직접 주입, 분석할 수 있는 SPME(Solid-phase microextraction)을 이용하여 황화물을 신속하게 분석할 수 있는 분석법을 개발하고 저 하였다. 분석방법에 대한 분석재현성, 분석한계를 조사하였으며, 이 분석방법이 대기중 황화물분석 방법으로 활용될 수 있도록 분석법을 확립하고자 하였다. (중략)

  • PDF

X-ray Magnetic Circular Dichroism

  • Kim, Jae-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.81-81
    • /
    • 2012
  • XMCD (X-ray Magnetic Circular Dichroism)는 원형 편광 X-선의 helicity 방향이 시료의 자화 방향과 평행, 또는 반평행할 때 시료의 색이 바뀌는 현상, 즉 흡수율이 달라지는 현상이다. XMCD측정이 가지는 장점은 첫째, 이 실험이 특정 원소의 흡수선에서 이루어지기 때문에 시료 전체에서 특정 원소에 의한 자기적 성질을 분리해서 측정할 수 있을 뿐만 아니라, 같은 원소라 하더라도 다른 화학적 환경에 있는 원자들의 자기적 성질의 분리가 가능하다는 점이다. 이러한 성질로 인해 XMCD는 다른 원소들로 이루어진 다층 박막(GMR, TMR 등의 자기저항박막 구조물)의 층별 자기적 성질 연구 및 신자성물질의 자기적 성질의 고유성 연구에 많이 이용되었다. XMCD가 가지는 두 번째 장점은 sum rule을 통하여 자기 모멘트의 두 가지 성분인 궤도 모멘트(orbital moment)와 스핀 모멘트(spin moment)의 구별이 가능하다는 점이다. 이러한 장점은 수직자기 메모리 연구 및 스핀과 격자 간의 상호작용이 중요한 역할을 하는 다강체 등의 연구에 많이 이용되어 왔다. XMCD 측정이 또 다른 장점이 될 수 있는 것은 표면에 대단히 민감하다는 점이다. VSM, SQUID 등의 측정방법으로는 시료의 체적이 대단히 작은 수 ${\AA}$ 정도의 초박막에 대해서는 충분한 민감도를 가질 수 없다. 그러나, XMCD의 측정 깊이는 수십 ${\AA}$ 정도로 표면에 민감하기 때문에 이러한 초박막에 대해서도 충분한 민감도를 가질 수 있어서 SMOKE(Surface Magneto-Optical Kerr Effect)와 표면 자성연구에 있어서 독보적인 장치로 이용되어 왔다. 이러한 장점으로 인해 XMCD는 1990년대 이후 분광학적으로 활발히 이용되어 왔을 뿐만 아니라, 대단히 빠르고 신호가 큰 현상이기 때문에 최근 들어서는 자구(magnetic domain) 관찰 등을 목적으로 한 자기 현미경 및 자기현상의 동역학 연구에도 많이 응용되고 있다. 이 강연에서는 이러한 X-선 자기 원형 이색성 현상의 원리 및 실험 방법 등을 설명하겠다. 또한 몇 가지 X-선 자기 원형 이색성을 이용한 최근 몇 가지 연구도 소개하려 한다.

  • PDF

Analysis of the Fracture Roughness of Crystalline Rock under Multi-stage Stress Conditions (다단계압력 환경하에서의 결정질 암석의 절리면 거칠기 변화 분석)

  • Choi, Junghae;Kim, Heyjin
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.237-249
    • /
    • 2019
  • The roughness changes on a fracture surface were analyzed via a multi-stage compression test under high temperatures to assess how the cracks in a rock mass affect groundwater movement. The analyzed samples consist of coarse granitic rocks from approximately 40 and 270 m depth, and fine granitic rocks from 500 m depth. The compression test was conducted on $20{\times}40{\times}5mm$ samples using a loading system where the pressure increases in 10 MPa increments to 120 MPa. A high-resolution 3D confocal laser scanning microscope (CLSM) was used to observe the surface changes, including the roughness changes, at each pressure step. The roughness change was calculated based on the roughness factor. The experimental results indicate that the roughness of the fracture surface varies with rock type under the stepwise pressure conditions. These data provide a basis for predicting groundwater flow along rock fractures.

Development and Applicability of Discharge Capacity Testing Apparatus Using Penetration Method (관입식 복합 통수능 시험기의 개발과 적용성)

  • Yoo, Nam Jae;Kim, Dong Gun;Park, Byung Soo;Jun, Sang Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5C
    • /
    • pp.313-320
    • /
    • 2008
  • The discharge capacity testing apparatus using penetration method, being able to simulate in laboratory the condition of embedding plastic board drains in field, was developed to investigate consolidation characteristics of ground and to figure out discharge capacity of drains. The developed apparatus with a mandrel and penetrating device was designed to insert PBD into the ground prepared by previously applied pressure, being different from the conventional testing method that the drain was installed and the ground material was poured subsequently. Discharge capacity tests with the conventional apparatus as well as the newly developed one were performed to assess the applicability of the latter. As a result of tests, the conventional method showed delayed consolidation due to overall disturbance of ground and local deformation of drain caused by inhomogeneity of ground. Therefore discharge capacity of drain with the conventional apparatus was measured more or less larger than the expected values whereas discharge capacity with new one could be measured similar to the actual value in field.

Determination of $^{14}C$ in Environmental Samples Using $CO_2$ Absorption Method ($Co_2$ 흡수법에 의한 환경시료중 $^{14}C$ 정량)

  • Lee, Sang-Kuk;Kim, Chang-Kyu;Kim, Cheol-Su;Kim, Yong-Jae;Rho, Byung-Hwan,
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.1
    • /
    • pp.35-46
    • /
    • 1997
  • A simple and precise method of $^{14}C$ was developed to analyze $^{14}C$ in the environment samples using a commercially available $^{14}CO_2$ absorbent and a liquid scintillation counter. An air sampler and a combustion system were developed to collect HTO and $^{14}CO_2$ in the air and the biological samples simultaneously. The collection yield of $^{14}CO_2$ by the air sampler was in the range of 73-89% . The yield of the combustion system was 97%. In preparing samples for counting, the optimum ratio of $CO_2$ absorbent to the scintillator for mixing was 1:1. No variation of the specific activity of $^{14}C$ in the counting sample was observed up to 70 days after preparation of the samples. The detection limit for$^{14}C$ was 0.025 Bq/gC, which is the level applicable to the natural level of $^{14}C$. The analytical result of $^{14}C$ obtained by the present method were within ${\pm}6%$ of the relative error from the one by the benzene synthesis. The specific activity of $^{14}C$ in the air collected at Taejon during the period of October 1996 ranged from 0.26 to 0.27 Bq/gC. The specific activity of $^{14}C$ in the air collected at 1km from the Wolsong nuclear power plant a 679 MWe PHWR, was $0.54{\pm}0.03$ Bq/gC. The ranges of specific activities of $^{14}C$ in the pine needles and the vegetations from the areas around the Wolsong nuclear power plant were 0.56-0.67 Bq/gC and 0.23-1.41 Bq/gC, respectively.

  • PDF