A Study of Correlation between SPT N-value and Exerted Electrical Energy Required for Ground Drilling II : Application Study (Field Pilot Test) (지반굴착에 소요되는 전기에너지와 표준관입시험 N값과의 상관관계 연구 II : 적용성 평가(현장시험시공))

  • Choi, Changho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.4
    • /
    • pp.55-62
    • /
    • 2012
  • In this application study, field pilot tests were performed to evaluate the validity of a proposed formula between the exerted electrical energy and SPT N-value based on the result of the basic study. Measurement sensors and recording system were developed to obtain exerted motor current and drilling depth in a field. By using the correlation formula proposed in the basic study, the measured motor current and boring speed were applied to predict SPT N-value and the predicted N-values were compared to SPT N-value of site exploration. From the comparisons it is verified that the exerted electrical energy to bore ground might be used to predict SPT N-value and pile tip location.

The Assesment of Tunnelling Induced Damage for the Opera House (Emphasis on 3D FEM Analysis) (터널 시공에 따른 오페라극장의 영향평가 (수치해석을 중심으로))

  • Hwang, Eui-Seok;Lee, Bong-Youl;Kim, Hak-Moon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.1
    • /
    • pp.3-12
    • /
    • 2002
  • This research work is to investigate influences of the Opera House in Arts Center caused by the twin tunnel construction. The Opera House of 3D structural feature with various type of foundations and adjacent twin tunnels are modeled in 3-Dimensional mesh for FEM analysis. Confirmation of safety is essential for this particular type of structure, and attention level and warning level of control criteria are examined for the protection of the Opera House by means of the analytical results.

  • PDF

Study on the Applicability of Dynamic Pile Load Test to Check Integrity during Installation of Extension Plate Attached PHC Piles and Bolts Spliced PHC Piles and the Correct Proof Test of the Transformed-installation PHC Piles (확장판 선단부착 PHC말뚝 및 볼트 수직이음을 사용한 PHC말뚝의 시공 중 건전성 확인을 위한 동재하시험의 적용성 및 변형시공법 PHC말뚝들의 올바른 검증시험에 관한 연구)

  • Kim, Myunghak;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.12
    • /
    • pp.115-131
    • /
    • 2018
  • Extension plate attached PHC piles and bolts spliced PHC piles were installed in field test site. Pile integrities were checked during installation with dynamic pile test and the actual pile conditions after installation were compared with integrity index (${\beta}$ index) by PDA test. Theoretically the break in near pile end or pile end (especially extension plate itself) was very difficult to access by integrity index (${\beta}$ index) and also require a high level of knowledge and field experience on PDA test. First actual wave equation of bolts spliced PHC piles due to bolts spliced equipment can be different with welding spliced. Second wave length of the stress wave from installing can be longer than the height of bolts spliced equipment (about 100 mm). Third Beta processing in PDA analysis function is very difficult to access without a high level of knowledge and field experience on wave equation. Above-mentioned three reasons can make conclusion that traditional PDA test in domestic site can not access the integrity of bolts spliced equipment in bolts spliced PHC piles.

A Suggestion of Mix, Construction Method and Quality Control Criteria of Fine-size Exposed Aggregate PCC Pavement by Experimental Construction (시험시공을 통한 소입경 골재노출 콘크리트 포장의 배합, 시공 및 품질관리 기준 제안)

  • Lee, Seung-Woo;Kim, Young-Kyu;Choi, Don-Hwa;Shim, Jae-Won;Yoo, Tae-Seok
    • International Journal of Highway Engineering
    • /
    • v.13 no.3
    • /
    • pp.51-63
    • /
    • 2011
  • Surface of fine-size exposed aggregate portland cement concrete pavements(FS-EAPCC) is consist by exposed coarse aggregate to remove upper 2~3mm mortar of concrete slabs. Advantages of FS-EAPCC are maintaining low-noise and adequate skid-resistance level during the performance period. However, FS-EAPCC is required rational management criteria for field application, since it is early stage for application. Design construction and quality control criteria of FS-EAPCC was temporary laboratory tests which including optimum mix and exposing method, selection of adequate aggregate, resistance against, environmental loading and etc. However, these criteria need to be validated base on field application. In this study, experimental constructions were performed and construction procedure and quality control criteria were suggested based on the performance of the FS-EAPCC.

Evaluation of Capability for Practicing CM at Risk in Korea (국내 시공책임형 건설사업관리 수행을 위한 기업 역량 평가)

  • Ryu, HanGuk;Lee, Sangwon;Choi, Jaehyun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.2
    • /
    • pp.79-87
    • /
    • 2020
  • The Korean domestic construction management at risk (CMAR) market is in the process of completing the pilot project execution under the leadership of the Ministry of Land, Infrastructure and Transport as of December 2019. The government starts practicing CMAR an alternative delivery method widely in order to diversify delivery methods and enhance construction technology. The CMAR market is thus expected to grow. This study was conducted to improve CMAR firms' capability by developing self-assessment tools for them to evaluate current capability more effectively. As a result of defining standard core capability and additional elements categorized by project execution phase and management area, and performing evaluation from the CMAR project participants, it was found that the general project management capability in the pre-design and procurement phase and quality management area was lower compared to the construction phase and other areas. In addition, the capability of cost management area was lower in spite of its high importance. Communication and coordination, process optimization, and target values achievement were at the initial level of capability and continuous improvement was required.

Stability evaluation of existing subway structure by adjacent excavation in urban tunnelling (도심지 터널 근접시공에 의한 기존 지하철 구조물 안정성 평가)

  • Han, Sangmin;Lee, Donghuk;Park, Duhee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.5
    • /
    • pp.339-357
    • /
    • 2021
  • As the construction of trans infrastructure using the underground tunnel have been rapidly increased, various nearby excavation of existed underground facility including subway structure has been occurred in urban tunnelling. The concern and worry relating to the safety and stability of the existed facility by nearby excavation is becoming the key issues in urban tunnelling. In this study, it was conducted for existed the subway station structure at Seoul subway line which was closely located in the new Dongbuk urban metro railway to determine the behavior characteristics of station structure according to adjacent tunnel construction. Also, it was reviewed the evaluation of the safety zone and excavation method for subway structure. And after a review of damage evaluation, track irregularities and structural calculation by using a numerical analysis, stability of the subway structure according to nearby tunnel excavation was evaluated to be secured. This study is expected to be applied as useful reference in advance if you need to review the effects of existed structure according to nearby construction in complex urban tunnelling.

A Comparison of Predicted Acoustics with the Measured Acoustic Performance of a Multi-purpose Hall (다목적공연장의 음향설계 및 음향실험 비교연구)

  • Lee Wangu;Haan Chan-Hoon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.565-568
    • /
    • 2004
  • 본 연구는 최근에 완공한 안산문화예술회관의 다목적 공연장의 음향설계부터 시공과 완공후의 음향실험을 통한 평가에 이르기까지의 일련의 음향설계 및 시공의 과정을 소개하고 설계시의 음향설정치와 완공 후 음향측정에 의한 음향성능을 비교함으로서 다목적홀의 음향에 대한 종합적인 평가를 시행하였다.

  • PDF

협회탐방/본회 - 정부위탁업무의 "시공능력평가공시" 및 적격심사평균비율 발표 등 회원봉사를 최우선으로 - 대한설비건설협회 회원부 -

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.237
    • /
    • pp.55-58
    • /
    • 2010
  • 대한설비건설협회 본회는 건설진흥사업 외에 기술 가스진흥사업, 회원봉사 및 조사사업, 정보화 사업, 기획 관리사업, 홍보사업 등 다양한 사업활동을 함으로써 설비건설업계 발전에 견인차 역할을 담당하고 있다. 본지는 지난해 12월호부터 전국 13개 시 도회를 대표하여 설비건설업계의 발전 및 위상강화, 회원사의 권익보호 등을 추진하고 있는 본회에 대하여 소개하고 있다. 이번 호에는 정부위탁업무 "시공능력 평가공시" 및 적격심사 평균비율 발표 등 회원봉사를 최우선으로 하는 회원부를 소개한다.

  • PDF

A Study on Damage Evaluations of Truss for Large Structure Health Monitoring (대형 구조물 상태평가를 위한 트러스 구조물 손상 평가에 관한 연구)

  • Lee, Jong-Ho;Kim, Seon-Gyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.130-131
    • /
    • 2016
  • This study was performed for application of Structural Health Monitoring system of large structures. In order to evaluate damage of a structure, strain data of truss members that are changing with damage are gained by FEM analysis program. These data are used to train Artificial Neural Network(ANN), and this ANN algorithm can be used to analysis strain data for evaluating damage of the truss members.

  • PDF

Experimental Evaluation of Soft Ground Breakwater Construction Performance (연약지반 방파제의 시공에 관한 실험적 평가)

  • 권오순;장인성;박우선;염기대
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.71-75
    • /
    • 2003
  • 최근 특별한 연약지반 처리공법을 적용하지 않고 자중을 감소시키고 구조적인 특성을 이용하여 연약지반 위에 설치하는 방파제가 제안ㆍ개발되고 있다. 일본에서는 자중을 가볍게 하고 파랑 하중을 역T형 구조와 말뚝을 이용하여 지지하는 구조를 시공한 사례도 있으며(문사강지 등, 1989), 국내에서는 Fig. 1과 같이 역T형 콘크리트 방파제의 자중만으로도 과도한 압밀침하가 발생되는 아주 연약한 지반에서 방파제의 자중을 줄이기 위해 부력통을 설치하고 설계 하중은 지중에 벽체를 설치하여 지지하는 구조를 제안하고 그 성능을 평가한 바 있다(권오순 등,2001 ; 권오순 등, 2002). (중략)

  • PDF