• Title/Summary/Keyword: 시간 반전 기법

Search Result 35, Processing Time 0.02 seconds

Numerical Study on Aerodynamic Performance of Counter-rotating Propeller in Hover Using Actuator Method (Actuator 기법을 이용한 제자리 비행하는 동축 반전 프로펠러 공력 성능에 관한 수치적 연구)

  • Kim, Dahye;Park, Youngmin;Oh, Sejong;Park, Donghun
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.3
    • /
    • pp.30-44
    • /
    • 2021
  • Experimental investigation of counter-rotating propellers is subject to multiple time and cost constraint because of additional design parameters unlike single propeller. Also, a lot of computing time and resources are required for numerical analysis due to consideration of the interference between the upper and lower propellers. In the present study, numerical simulations were conducted to investigate the hover performance of counter-rotating propellers by using actuator method which is considered to be time-efficient. The accuracy of the present numerical methods was validated by comparing the ANSYS Fluent which is commercial CFD code. The axial spacing and rotational speed were selected as the analysis variables, and the aerodynamic performance was obtained under various conditions. Based on the obtained results, the Figure of Merit (FM) of single propeller and counter-rotating propellers and a prediction factor which enables prediction of counter-rotating propeller performance using a single propeller were derived to evaluate availability of the actuator method.

Investigating the Spatial Focusing of Time Reversal Lamb Waves Using a Virtual Sensor Model on a Rectangular Plate (직사각형 판에서 가상탐지자 모델을 이용한 시간반전램파의 공간모임 규명)

  • Park, Hyun-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.5
    • /
    • pp.553-567
    • /
    • 2011
  • During the last three years, the possibility of the time reversal Lamb waves has been paid attention to for structural health monitoring of a plate. This study proposes a numerical scheme which can simulate the spatial focusing of time reversal Lamb waves on a rectangular plate. In this scheme, a time reversal process is formulated in the frequency domain using active virtual sensors being equivalent to the mirror effects of an actual sensor due to wave reflection on the plate boundary. Forward and backward Lamb wave propagations are represented by scalar functions for simulating the spatial focusing of time reversal Lamb waves. The validity of the proposed scheme is demonstrated through the comparison to the results of finite element analysis in which the spatial focusing of time reversal Lamb waves is realized by wafer-type piezoelectric(PZT) transducers collocated on a rectangular plate.

T1-, T2-weighted, and FLAIR Imaging: Clinical Application (T1, T2강조영상, FLAIR영상의 임상 적용)

  • Kim, Jae-Hyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • T1-, and T2-weighted imagings and FLAIR (fluid attenuated inversion recovery) imaging are fundamental imaging methods in the brain. T1-weighted imaging is a spin-echo sequence with short TR and short TE and produces the tissue contrast by different T1 relaxation times. In other words, short TR maximizes the difference of the longituidinal magnetization recovery between the tissues. T2-weighted imaging is a spin-echo sequence with long TR and long TE and produces the tissue contrast by different T2 relaxation times. Long TE maximizes the difference of the transverse magnetization decay between the tissues. FLAIR is an inversion recovery sequence using 180 degree inversion pulse. 2500 msec of inversion time is applied to suppress the CSF signal.

  • PDF

Structural Damage Detection by Using the Time-Reversal Process of Lamb Waves and the Imaging Method (Lamb파의 시간-반전과정 및 이미지기법을 이용한 손상탐지)

  • Jun, Yong-Ju;Lee, U-Sik
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.320-326
    • /
    • 2011
  • This paper proposes a baseline-free SHM technique in which the time-reversal process of Lamb waves and the imaging method are used. The proposed SHM technique has three distinct features when compared with the authors' previously proposed one: (1) It use the reconstructed signal for damage diagnosis, without need to extract the damage signal as the difference between reconstructed signal and initial input signal; (2) It use the imaging method based on the time-offlight information from the reconstructed signal, instead of using a pattern comparison method; (3) In order to make the damage image more clear, the modified mathematical definition of damage image in a pixel is used. The proposed SHM technique is evaluated through the damage detection experiment for an aluminum plate with damage at different locations.

A Low Power PRAM using a Power-Dependant Data Inversion Scheme (전력-종속 데이터 반전 기법을 이용한 저전력 상변환 메모리)

  • Yang, Byung-Do
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.95-100
    • /
    • 2007
  • A low power PRAM using a power-dependant data inversion (PDI) scheme is proposed. The PRAM consumes large write power because large write currents are required during long time. Also, the power consumptions for storing #1# and #0# are different. The PDI circuit compares the power consumptions to store the original data and its inverted data, and then it stores the less power consuming data. Although the PDI scheme needs an additional inversion bit per data, the maximum and average powers of the PDI can be under 50% and 37.5% of the conventional write scheme, respectively. The average power for storing 8bit data is under 41%, due to the inversion bit. The 1K-bit PRAM chip with 128$\times$8bits was implemented with a 0.8${\mu}m$ CMOS technology with a 0.5${\mu}m$ GST cell.

Effect of Stabilizing Reversal Technique of Proprioceptive Neuromuscular Facilitation and Taping Convergence on Wrist Pain and Grip Strength (고유수용성신경근촉진법의 안정적 반전기법과 테이핑 융합이 손목통증과 악력에 미치는 영향)

  • Kim, Beom-Ryong;Yi, Dong-Hyun;Yim, JongEun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.117-124
    • /
    • 2018
  • This study investigated the effect of wrist taping (WT) after application of stabilizing reversal technique (SRT) of proprioceptive neuromuscular facilitation (PNF) on pain and grip strength (GS) in patients with wrist pain (WP). Twenty patients with WP were randomly assigned to an experimental group (n=10) that received WT after application of SRT, and a control group (n=10) that received WT after application of stretching. The total intervention time consisted of a maximum of 10 minutes including breaks, and was performed 5 times a week for 2 weeks. Pain reduction was measured using a visual analogue scale. GS was measured using a dynamometer. Within group changes in pain and GS were significant in both experimental and control groups (p<0.01). Between group changes in pain and GS were greater in the experimental group than in the control group (p<0.01). This findings indicate that SRT of PNF and WT convergence can be an effective intervention for patients with WP. Continued development of convergence interventions for patients with WP various conditions in practice, is suggested.

Signal Change of Normal Saline by Oxygen Injection in FLAIR Image (산소주입에 의한 FLAIR 영상에서 생리식염수의 신호 변화)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.55-63
    • /
    • 2019
  • It was reported that there were some cases in which signal was not inhibited but high signal appeared in cerebrospinal fluid on FLAIR(fluid attenuated inversion recovery) of MRI(Magnetic Resonance Imaging) in case a person inhales high-concentration oxygen. This study was to prepare basic database. We produced a phantom fixed with agar gel and by using it, obtained the images of the signals of normal saline into which oxygen was injected and normal saline diluted with contrast media by changing the TI(Inversion Time) of FLAIR technique and analyzed them. In the result of FLAIR technique of MRI using Philips Achieva MR 3.0T in Busan P Hospital, the SNR(Signal to Noise Ratio) of normal saline into which oxygen was injected was higher than the SNR of normal saline into which oxygen was not injected. However, it was not higher than the SNR of normal saline diluted with contrast media. In the TI 1,800ms, we could obtain the images which do not have the rise of the signal due to oxygen. In the CNR(Contrast to Noise Ratio) of normal saline into which oxygen was injected and normal saline diluted with contrast media as well, it was higher in the TI 1,800ms than in the TI 2,800ms that is mainly used clinically. It is thought that the result of this study could be basic database for studies on change of signal of cerebrospinal fluid as a result of injection of oxygen in FLAIR technique of MRI.

Medkum TAu Inversion Recover(MTIR) Sequence for White Matter Suppression in Brain Cortical Lesions (뇌피질 질환에서 뇌백질 신호 억제를 위한 중간시간 반전회복 영상 기법)

  • 정경호;이정민;김종수
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.60-65
    • /
    • 1999
  • Purpose : The purpose of this study was to evaluate the image quality, contrast characteristics, and possible clinical utility of Medium Tau Inversion Recovery(MTIR) sequence with white matter suppression in patients with brain cortical lesion. Materials and methods : Two normal volunteers and twenty-one patients with cortical lesion were scanned with MTIR as well as other MR imaging sequences. Gray-white matter contrast was evaluated objectively using region-of-interest calculations, including percent contrast and contrast-to-noise ratio(CNR). MTIR sequence was visually compared with other sequences in 21 patients with cortical lesion including conspicuity and detection rate. Results : MTIR sequence had the highest present contrast and CNR between the gray matter and white matter. In twenty-one cases of cortical lesion including cortical dysplasia, MTIR sequence improved delineation and conspicuity of lesion, but MTIR sequence could not detect new lesions. Conclusion : The MTIR sequence well delineated the cortical lesions, particularly in including cortical dysplasia. It may be used as an adjunctive imaging sequence in case of poor gray and white matter differentiation with conventional T1-weighted sequences.

  • PDF

Development and Validations of the Aerodynamic Analysis Program of Multi-Rotors by Using a Free-Wake Method (자유후류 기법을 이용한 다중로터 공력해석 프로그램의 개발 및 검증)

  • Park, Sang-Gyoo;Lee, Jae-Won;Lee, Sang-Il;Oh, Se-Jong;Yee, Kwang-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.10
    • /
    • pp.859-867
    • /
    • 2007
  • The objective of this study is to develop and validate a numerical method which can handle the multi-rotor aerodynamic characteristics. For the purpose of power estimation, table look-up method is implemented to the existing unsteady panel code that is coupled with a time-marching free wake model. Also, the Reynolds number scaling is implemented for the application to various regions of Reynolds number. The computed results are validated against the available experimental data for coaxial and tandem rotors. In the validation case for the coaxial rotor, more accurate result is acquired when the thickness effect is considered. The wake instability problem occurs at a particular separation distance between the rotors for tandem rotors. The wake instability is avoided by setting the single-rotor wake geometry as the initial wake geometry for the multi-rotor analysis. The estimated result for rotor separation effect is compared with the result of the momentum theory.