• Title/Summary/Keyword: 시간제약조건

Search Result 575, Processing Time 0.028 seconds

Edge to Edge Model and Delay Performance Evaluation for Autonomous Driving (자율 주행을 위한 Edge to Edge 모델 및 지연 성능 평가)

  • Cho, Moon Ki;Bae, Kyoung Yul
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.1
    • /
    • pp.191-207
    • /
    • 2021
  • Up to this day, mobile communications have evolved rapidly over the decades, mainly focusing on speed-up to meet the growing data demands of 2G to 5G. And with the start of the 5G era, efforts are being made to provide such various services to customers, as IoT, V2X, robots, artificial intelligence, augmented virtual reality, and smart cities, which are expected to change the environment of our lives and industries as a whole. In a bid to provide those services, on top of high speed data, reduced latency and reliability are critical for real-time services. Thus, 5G has paved the way for service delivery through maximum speed of 20Gbps, a delay of 1ms, and a connecting device of 106/㎢ In particular, in intelligent traffic control systems and services using various vehicle-based Vehicle to X (V2X), such as traffic control, in addition to high-speed data speed, reduction of delay and reliability for real-time services are very important. 5G communication uses high frequencies of 3.5Ghz and 28Ghz. These high-frequency waves can go with high-speed thanks to their straightness while their short wavelength and small diffraction angle limit their reach to distance and prevent them from penetrating walls, causing restrictions on their use indoors. Therefore, under existing networks it's difficult to overcome these constraints. The underlying centralized SDN also has a limited capability in offering delay-sensitive services because communication with many nodes creates overload in its processing. Basically, SDN, which means a structure that separates signals from the control plane from packets in the data plane, requires control of the delay-related tree structure available in the event of an emergency during autonomous driving. In these scenarios, the network architecture that handles in-vehicle information is a major variable of delay. Since SDNs in general centralized structures are difficult to meet the desired delay level, studies on the optimal size of SDNs for information processing should be conducted. Thus, SDNs need to be separated on a certain scale and construct a new type of network, which can efficiently respond to dynamically changing traffic and provide high-quality, flexible services. Moreover, the structure of these networks is closely related to ultra-low latency, high confidence, and hyper-connectivity and should be based on a new form of split SDN rather than an existing centralized SDN structure, even in the case of the worst condition. And in these SDN structural networks, where automobiles pass through small 5G cells very quickly, the information change cycle, round trip delay (RTD), and the data processing time of SDN are highly correlated with the delay. Of these, RDT is not a significant factor because it has sufficient speed and less than 1 ms of delay, but the information change cycle and data processing time of SDN are factors that greatly affect the delay. Especially, in an emergency of self-driving environment linked to an ITS(Intelligent Traffic System) that requires low latency and high reliability, information should be transmitted and processed very quickly. That is a case in point where delay plays a very sensitive role. In this paper, we study the SDN architecture in emergencies during autonomous driving and conduct analysis through simulation of the correlation with the cell layer in which the vehicle should request relevant information according to the information flow. For simulation: As the Data Rate of 5G is high enough, we can assume the information for neighbor vehicle support to the car without errors. Furthermore, we assumed 5G small cells within 50 ~ 250 m in cell radius, and the maximum speed of the vehicle was considered as a 30km ~ 200 km/hour in order to examine the network architecture to minimize the delay.

Analysis of Pre-service Science Teachers' Responsive Teaching Types and Barriers of Practice (예비과학교사들의 반응적 교수 유형 및 실행의 제약점 분석)

  • Cho, Mihyun;Paik, Seoung-Hey
    • Journal of The Korean Association For Science Education
    • /
    • v.40 no.2
    • /
    • pp.177-189
    • /
    • 2020
  • In this study, we implemented an education program to improve the responsive teaching ability of pre-service science teachers, and analyzed the responsive teaching practices revealed during the program process. Through this, we derived the types and characteristics of responsive teaching practice, identified factors that made it difficult for pre-service teachers to practice, and obtained empirical data on under what conditions the responsive teaching capacity of pre-service teachers was developed. For this purpose, a practice-based teacher education program was designed and carried out for 14 pre-service teachers who had no experience in responsive teaching. The program consists of four steps; observation of class, practice through rehearsal, application in practicum, and post-reflection on educational practice. In particular, qualitative analysis was conducted on the types of responsive teaching and their detrimental factors revealed during application in practicum. As a result of the analysis, four types were derived; discriminator type, communicator type, guide type, and facilitator type. Each type was identified as having a common responsive teaching step element. The education program implemented in this study was effective for pre-service teachers to recognize the importance of student-participation class and the educational effect of responsive teaching. However, three barriers that prevented pre-service teachers from responsive teaching practice were also analyzed. First was the pressure to achieve specific learning goals within a given class time. Second was the rigid belief of the fixed curriculum. Third was the obsession that the teacher should lead the class. Based on these results, it was suggested that in order to improve the responsive teaching ability of pre-service teachers, it is necessary to support the recognition of breaking out of the thinking the time constraint, the flexibility of the curriculum, and the role of teacher as a class supporter.

Removal of Methyl tert-Butyl Ether (MTBE) by Modified Fenton Process for in-situ Remediation (Methyl tert-Butyl Ether(MTBE)의 in-situ Remediation을 위한 Modified Fenton Process에 관한 연구)

  • Chung, Young-Wook;Seo, Seung-Won;Kim, Min-Kyoung;Lee, Jong-Yeol;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.2
    • /
    • pp.27-36
    • /
    • 2007
  • A recent study showed that MTBE can be degraded by Fenton's Reagent (FR). The treatment of MTBE with FR, however, has a definite limitation of extremely low pH requirement (optimum pH $3{\sim}4$) that makes the process impracticable under neutral pH condition on which the ferrous ion precipitate forming salt with hydroxyl anion, which result in the diminishment of the Fenton reaction and incompatible with biological treatment. Consequently, this process using only FR is not suitable for in-situ remediation of MTBE. In order to overcome this limitation, modified Fenton process using NTA, oxalate, and acetate as chelating reagents was introduced into this study. Modified Fenton reaction, available at near neutral pH, has been researched for the purpose of obtaining high performance of oxidation efficiency with stabilized ferrous or ferric ion by chelating agent. In the MTBE degradation experiment with modified Fenton reaction, it was observed that this reaction was influenced by some factors such as concentrations of ferric ion, hydrogen peroxide, and each chelating agent and pH. Six potential chelators including oxalate, succinate, acetate, citrate, NTA, and EDTA were tested to identify an appropriate chelator. Among them, oxalate, acetate, and NTA were selected based on their remediation efficiency and biodegradability of each chelator. Using NTA, the best result was obtained, showing more than 99.9% of MTBE degradation after 30 min at pH 7; the initial concentration of hydrogen peroxide, NTA, and ferric ion were 1470 mM, 6 mM, and 2 mM, respectively. Under the same experimental condition, the removal of MTBE using oxalate and acetate were 91.3% and 75.8%, respectively. Optimum concentration of iron ion were 3 mM using oxalate which showed the greatest removal efficiency. In case of acetate, $[MTBE]_0$ decreased gradually when concentration of iron ion increased above 5 mM. In this research, it was showed that modified Fenton reaction is proper for in-situ remediation of MTBE with great efficiency and the application of chelatimg agents, such as NTA, was able to make the ferric ion stable even at near neutral pH. In consequence, the outcomes of this study clearly showed that the modified Fenton process successfully coped with the limitation of the low pH requirement. Furthermore, the introduction of low molecular weight organic acids makes the process more available since these compounds have distinguishable biodegradability and it may be able to use natural iron mineral as catalyst for in situ remediation, so as to produce hydroxyl radical without the additional injection of ferric ion.

The mathematical model of temperature dependent growth of Scuticociliate Miamiensis avidus in vitro and in vivo conditions (In vitro와 in vivo에서의 온도에 따른 스쿠티카충 성장의 수리 모델)

  • Oh, Chun-Young
    • Journal of fish pathology
    • /
    • v.26 no.2
    • /
    • pp.65-75
    • /
    • 2013
  • Population growth equation of scuticociliate Miamiensis avidus was obtained from the experimental results of in vitro culture condition to estimate the growth rate and carrying capacity from the growth equation. In addition, intraperitoneal infections into olive flounder Paralichthys olivaceus were carried out into 2 different conditions: different concentrations of M. avidus in same water temperature and same concentration of M. avidus in different water temperatures. Olive flounder mortality was threshold dependent with both the temperature and M. avidus density parameters. In this paper, we propose a mathematical model to study M. avidus growth in olive flounder based upon the interactions between parasite and host. The mathematical model was logistic growth differential equation (1.2). The parameters were found with Matlab program through the Levenberge-Marquardt method. In theorem, equilibrium values between the infected fish population and dead population could found. Our equilibrium points were a stable equilibrium and an unstable equilibrium. From the equation (1.6), it was possible to predict the amount of cumulative mortality of olive flounder along with the time after M. avidus infection.

Physicochemical Properties and Composition of Ginsenosides in Red Ginseng Extract as Revealed by Subcritical Water Extraction (아임계수 추출에 의한 홍삼 추출물의 진세노사이드 조성 및 이화학적 특성)

  • Lee, Joo-Mi;Ko, Min-Jung;Chung, Myong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.757-764
    • /
    • 2015
  • Red ginseng was treated by subcritical water extraction (SWE) whose two parameters were the extraction temperature ($105-150^{\circ}C$) and time (5-20 min) under a high pressure. The oBrix value, solid content, color difference, and turbidity of the red ginseng extract increased with increasing extraction time and temperature, while the pH decreased. The total concentration of ginsenosides in the red ginseng extract was maximal at $120^{\circ}C$ and 20 min. The concentrations of ginsenosides Rg3 and Rh1 were maximal at $150^{\circ}C$ and 15 min. The concentrations of Rg3 and Rh1 were respectively 3.5-5 times and 2-2.5 times higher than those treated by conventional extraction methods with hot water, ethanol, and methanol. SWE is a particularly effective method for the selective extraction of less-polar ginsenosides such as Rg3 which is well known to exert strong anticancer effects.

Time-series Analysis of Pyroclastic Flow Deposit and Surface Temperature at Merapi Volcano in Indonesia Using Landsat TM and ETM+ (Landsat TM과 ETM+를 이용한 인도네시아 메라피 화산의 화산쇄설물 분포와 지표 온도 시계열 분석)

  • Cho, Minji;Lu, Zhong;Lee, Chang-Wook
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.5
    • /
    • pp.443-459
    • /
    • 2013
  • Located on Java subduction zone, Merapi volcano is an active stratovolcano with a volcanic activity cycle of 1-5 years. Merapi's eruptions were relatively small with VEI 1-3. However, the most recent eruption occurred in 2010 was quite violent with VEI 4 and 386 people were killed. In this study, we have attempted to study the characteristics of Merapi's eruptions during 18 years using optical Landsat images. We have collected a total of 55 Landsat images acquired from July 6, 1994 to September 1, 2012 to identify pyroclastic flows and their temporal changes from false color images. To extract areal extents of pyroclastic flows, we have performed supervised classification after atmospheric correction by using COST model. As a result, the extracted dimensions of pyroclastic flows are nearly identical to the CVP monthly reports. We have converted the thermal band of Landsat TM and ETM+ to the surface temperature using NASA empirical formula and calculated time-series of the mean surface temperature in the area of peak temperature surrounding the crater. The mean surface temperature around the crater repeatedly showed the tendency to rapidly rise before eruptions and cool down after eruptions. Although Landsat satellite images had some limitations due to weather conditions, these images were useful tool to observe the precursor changes in surface temperature before eruptions and map the pyroclastic flow deposits after eruptions at Merapi volcano.

Precise Rectification of Misaligned Stereo Images for 3D Image Generation (입체영상 제작을 위한 비정렬 스테레오 영상의 정밀편위수정)

  • Kim, Jae-In;Kim, Tae-Jung
    • Journal of Broadcast Engineering
    • /
    • v.17 no.2
    • /
    • pp.411-421
    • /
    • 2012
  • The stagnant growth in 3D market due to 3D movie contents shortage is encouraging development of techniques for production cost reduction. Elimination of vertical disparity generated during image acquisition requires heaviest time and effort in the whole stereoscopic film-making process. This matter is directly related to competitiveness in the market and is being dealt with as a very important task. The removal of vertical disparity, i.e. image rectification has been treated for a long time in the photogrammetry field. While computer vision methods are focused on fast processing and automation, photogrammetry methods on accuracy and precision. However, photogrammetric approaches have not been tried for the 3D film-making. In this paper, proposed is a photogrammetry-based rectification algorithm that enable to eliminate the vertical disparity precisely by reconstruction of geometric relationship at the time of shooting. Evaluation of proposed algorithm was carried out by comparing the performance with two existing computer vision algorithms. The epipolar constraint satisfaction, epipolar line accuracy and vertical disparity of result images were tested. As a result, the proposed algorithm showed excellent performance than the other algorithms in term of accuracy and precision, and also revealed robustness about position error of tie-points.

PSO-Based PID Controller for AVR Systems Concerned with Design Specification (설계사양을 고려한 AVR 시스템의 PSO 기반 PID 제어기)

  • Lee, Yun-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.330-338
    • /
    • 2018
  • The proportional-integral-derivative(PID) controller has been widely used in the industry because of its robust performance and simple structure in a wide range of operating conditions. However, the AVR(Automatic Voltage Regulator) as a control system is not robust to variations of the power system parameters. Therefore, it is necessary to use PID controller to increase the stability and performance of the AVR system. In this paper, a novel design method for determining the optimal PID controller parameters of an AVR system using the particle swarm optimization(PSO) algorithm is presented. The proposed approach has superior features, including easy implementation, stable convergence characteristic and good computational efficiency. In order to assist estimating the performance of the proposed PSO-PID controller, a new performance criterion function is also defined. This evaluation function is intended to reflect when the maximum percentage overshoot, the settling time are given as design specifications. The ITAE evaluation function should impose a penalty if the design specifications are violated, so that the PSO algorithm satisfies the specifications when searching for the PID controller parameter. Finally, through the computer simulations, the proposed PSO-PID controller not only satisfies the given design specifications for the terminal voltage step response, but also shows better control performance than other similar recent studies.

A Plan for Introduction of New Performance-Enhancing Underwriting Technique (언더라이팅 기능 강화를 위한 신기법 도입방안)

  • Park, Sang-Jun
    • The Journal of the Korean life insurance medical association
    • /
    • v.22
    • /
    • pp.99-120
    • /
    • 2003
  • 그 동안 지속적인 경제성장을 바탕으로 한국의 생명보험산업은 양적으로 성장하였다. 그러나 내면을 살펴보면 외형을 떠받칠 만큼 내실있게 성장했는지에 대해서는 많으 의구심을 갖게 한다. 현실적으로 경제성장을 바탕으로 한 외형성장은 한계를 맞을 수 밖에 없으며, 이제는 질적인 내실을 기하기 위해 그 동안 소홀히 했던 보함산업의 전반의 체질개선이 필요하다. IMF이후 경영이 부실한 보험사들이 퇴출되면서 전면적인 개편이 이루어졌고, 또한 보험사 내부에서도 전반적인 개혁의 필요성을 인식하여 여러 방면으로 방안을 구체화하고 있다. 본 논문은 이러한 상황하에서 생명보험산업의 기존 문제점 개선방안의 일환으로, 보험산업의 가장 핵심분야라 할 수 있는 언더라이팅 분야의 국내현황을 살펴보면서 보험선진국의 제도 및 운영현황과 비교 분석하여 부문별 문제점을 도출하고, 그에 따른 개선방안을 제안하게 되었으며, 본 논문에서 제시된 개선방안을 요약해 보면 다음과 같다. 첫째, 언더라이팅을 신속 정확하게 수행하고 도덕적 위험을 배제하기 위하여 개선된 정보교환시스템 제도를 구축해야 하며, 사정자료의 수집업무를 전문기관에게 아웃소싱함으로써 비용절감을 기하여야 한다. 이와 아울러 모집인의 전문성을 제고시켜 보험계약 청약서와 모집인 보고서가 정확하게 작성되도록 하고 언더라이팅 실적과 연계한 인센티브제도에 의하여 모집수당이 지급되도록 하여 언더라이팅이 효과적으로 수행되도록해야 할 것이다. 둘째, 언더라이팅기법의 선진화를 기함으로써 위험에 상응하는 보험료를 부가하여 위험에 노출되어 있는 가망고객의 보험가입율을 높이고, 보험사고 발생시 실질적인 보험혜택을 누리도록 하여야 한다. 이를 위한 실천방안으로 의적 직업적 재정적 언더라이팅 선진기법을 도입하여 각 부문의 역량을 강화해야 할 것이다. 특히 제도적으로 개인신용정보의 언더라이팅 활용이 제한되어 있는 현실에서 이를 법제도 내로 흡수하면서 개인의 사생활 유지라는 목적을 동시에 달성되도록 하는 재정적 언더라이팅 기법의 강화가 특히 중요하리라 생각된다. 아울러 언더라이팅 업무를 효과적 효율적 수행을 통해 일관성 있는 의사결정이 이루어질 수 있도록 지원하는 언더라이팅 시스템구축을 통해 정형화된 인수과정은 결정시스템화하고, 복잡한 위험의 경우 자문 시스템으로 운영하여 간단한 언더라이팅 업무는 구축된 시스템을 통해 즉각 해결함으로써 시간을 절약할 수 있고, 언더라이팅 인력은 보다 전문적인 부문에 집중하도록 해야 할 것이다. 마지막으로, 비표준위험시장의 활성화를 위해서는 현재의 제약조건인 생명보험 상품개발을 세트형에서 조립형으로 전환하고, 재보험으로 위험을 분산하여 비표준위험의 인수를 증대하여야 할 것이다. 이와 더불어 언더라이팅 과정에서 얻어진 피보험자의 사정자료를 활용하여 고객에게 필요한 의료정보 등을 제공함으로써, 피보험자와 유대관계를 돈독히 하여 기존계약이 계속 유지되도록 하며, 추가계약이 이루어지도록 해야 할 것이다. 이상과 같은 비표준위험의 언더라이팅 개선방안이 보다 효과적으로 수행되고 발전하기 위해서는 통계축적 및 관리, 전문 언더라이터 양성, 전산을 이용한 언더라이팅 확대 등이 이루어져야 하므로 향후 이에 대한 집중적인 연구가 있어야 할 것이다.

  • PDF

A Burn-in Test System with Dynamic Bone Allocation (동적 존 할당이 가능한 번인 시험 시스템)

  • Oh, Sam-Kweon;Shin, Joong-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.75-80
    • /
    • 2009
  • Bum-in test is one for eliminating semiconductor devices that are subject to early failures and other operational problems; it is usually carried out on the devices by imposing severe test conditions such as elevated voltages, temperatures, and time. In order for such a test to be performed, each burn-in board having devices to be tested, needs to be inserted into a corresponding slot. A set of such slots is called a zone. The slots comprising a zone can only have the burn-in boards with the devices of the same type. In order to test many different types of semiconductor devices, it is desirable to build a burn-in test system to have as many zones as possible. A zone controller controlling a zone, is a device that performs a burn-in test and collects test results. In case of existing systems, each zone controller takes care of a zone that consists of a fixed number of slots. Since a zone controller is, in most cases, embedded into a workstation that controls the overall testing process, adding new zone controllers is restricted by the spaces for them. As a way to solve or alleviate these problems, a dynamic zone system in which the number of slots in a zone can be dynamically allocated, is presented. This system maximizes the efficiency of system utilization, by altering the number of slots and hence minimizing the idle slots of a zone. In addition, all the test operations being performed must be aborted for maintenance in existing systems. In dynamic zone systems, however, a separate and independent maintenance is allowed for each slot, as long as the main power supply system has no problem.