• Title/Summary/Keyword: 시간장치

Search Result 4,177, Processing Time 0.031 seconds

Investigation into influence of sound absorption block on interior noise of high speed train in tunnel (터널 내부 도상 블록형 흡음재의 고속철도차량 내부 소음에 미치는 영향에 대한 고찰)

  • Lee, Sang-heon;Cheong, Cheolung;Lee, Song-June;Kim, Jae-Hwan;Son, Dong-Gi;Sim, Gyu-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.223-231
    • /
    • 2018
  • Recently, due to various environmental problems, blast tracks in tunnel are replaced with concrete tracks, but they have more adverse effects on noise than blast tracks so that additional noise measures are needed. Among these measures, sound-absorbing blocks start to be used due to its easy and quick installation. However, the performance of sound absorption blocks need to be verified under real environmental and operational conditions. In this paper, interior noise levels in KTX train cruising in Dalseong tunnel are measured before and after the installation of sound-absorbing blocks and the measured data are analyzed and compared. Additionally, noise reduction are estimated by modeling the high speed train, the tunnel and absorption blocks. Measurement devices and methods are used according to ISO 3381 and the equivalent sound pressure levels during the cruising time inside the tunnel are computed. In addition to overall SPLs(Sound Pressure Levels), 1/3-octave-band levels are also analyzed to account for the frequency characteristics of sound absorption and equipment noise in a cabin. In addition, to consider the effects of train cruising speeds and environmental conditions on the measurements, the measured data are corrected by using those measured during the train-passing through the tunnels located before and behind the Dalseong tunnel. Analysis of measured results showed that the maximum noise reduction of 6.8 dB (A) can be achieved for the local region where the sound-absorbing blocks are installed. Finally, through the comparison of predicted 1/3-octave band SPLs for the KTX interior noise with the measurements, the understanding of noise reduction mechanism due to sound-absorbing blocks is enhanced.

Studies on Energy Metabolism of Growing Chicken (닭의 에너지 대사(代謝)에 관(關)한 연구(硏究))

  • Kwon, Soon Ki;Oh, Hong Rock
    • Korean Journal of Agricultural Science
    • /
    • v.9 no.2
    • /
    • pp.540-545
    • /
    • 1982
  • An energy metabolism study was conducted with two commercial strains of meat-type chickens, Hubbard and Cobb, and two egg strains, Hy Line and Korean-bred Hanhyup 325. The heat production of growing chickens from each strain were measured by the use of an open-circuit gravimetric respiration calorimeter. The data obtained from this study were summarized as fallows. 1. The average body weight of 9-wk-old Hubbard broilers reared in battery cages was 2,570g/bird. The average body weights of 9-wk-old Hy Line chicks and Hanhyup 325 were 777 and 748g/bird, respectively. 2. At 3 weeks of age, the Hubbard broiler chicks consumed two times the feed consumed by Hy Line chicks (54.6g VS. 26.7g/bird/day). These values increased to 151g and 57.2g/bird/day, respectively, at 8 weeks of age, indicating that the difference in feed intake between meat and egg-type chicks tends to increase as they grow older. In terms of water consumption, the 5-wk-old Hubbard broiler chicks drank $226m{\ell}/bird/day$ as compared with $58m{\ell}$ by Hy Line chicks. These values increased to 282 and $70m{\ell}$, respectively, at 8 weeks of age. 3. The excreta outputs of Hubbard broilers and Hy Line chicks were 18.7 and 6.1g DM/bird/day at 4 weeks of age, and 41.5 and 10.0g DM/bird/day at 8 weeks of age, respectively. 4. The energy metabolizability of broiler chicks were 75.4~77.1% compared to 75.0~83.5% by egg-type chicks. 5. The respiratory quotient (RQ) was between 0.78 and 0.97. There seems to be no difference in RQ between meat and egg-type chicks. The RQ tended to decrease when feed intake was low and vice versa. 6. Both meat and egg-type chicks produced $83.1{\sim}123.1Kcal/kg^{\frac{3}{4}}B.W./day$. The considerably low value of $83Kcal/kg^{\frac{3}{4}}B.W./day$ was obtained when the chicks were off the feed under the stressful conditions. The high value of 123.1Kcal was obtained when the chicken chamber temperature rose to $27{\sim}34^{\circ}C$.

  • PDF

Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle (가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.605-617
    • /
    • 2015
  • The ultimate goal of this research is to develop a botanical biofiltration system that combines a green interior, biofiltering, and automatic irrigation to purify indoor air pollutants according to indoor space and the size of biofilter. This study was performed to compare the stability of air flow characteristics and removal efficiency (RE) of fine dust within a wall-typed (vertical) botanical biofilter depending on humidifying cycle and to investigate RE of volatile organic compounds (VOCs) by the biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be suitable for indoor space utilization. As a result, relative humidity, air temperature, and soil moisture content (SMC) within the biofilter showed stable values regardless of three different humidifying cycles operated by the metering pump. In particular, SMCs were consistently maintained in the range of 27.1-29.7% during all humidifying cycles; moreover, a humidifying cycle of operating for 15 min and pausing for 45 min showed the best horizontal linear regression (y = 0.0008x + 29.09) on SMC ($29.0{\pm}0.2%$) during 120 hour. REs for number of fine dust (PM10) and ultra-fine dust (PM2.5) particles passed through the biofilter were in the range of 82.7-89.7% and 65.4-73.0%, respectively. RE for weight of PM10 passed through the biofilter was in the range of 58.1-78.9%, depending on humidifying cycle. REs of xylene, ethyl benzene, total VOCs (TVOCs), and toluene passed through the biofilter were in the range of 71.3-75.5%, while REs of benzene and formaldehyde (HCHO) passed through the biofilter were 39.7% and 44.9%, respectively. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was very effective for indoor air purification.

Verification of accuracy detection of the cows estrus using biometric information measuring device (생체정보 측정장치를 활용한 젖소 발정탐지의 정확도 검증)

  • Yang, Ka-Young;Woo, Sae-Mee;Kwon, Kyeong-Seok;Choi, Hee-Chul;Jeon, Jung-Hwan;Lee, Jun-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.652-657
    • /
    • 2018
  • Breeding control in a farm is a very important factor affecting milk productivity. Breeding management is important for the early detection of estrus, and reliable, automatic, more accurate, and faster monitoring of the timing of dairy cows is essential for farmers. This study measured the accuracy of estrus using the estrus indications, changes in activities, rumination activities, ruminal temperature, and pH. The biomedical information device S1 used in this study provided an estrus notice using the rumen temperature, pH, cow activities, and number of drinking estimations, which were inserted in the rumen through the oral route. The S2 device was used in the estrus notice for the rumen activities and cow activities. The data collected on the instrument were collected at intervals of 2 hours per day at the reference days (RD: -7~-3, +7~+ 3) +2), 7 days before insemination, and 7 days after insemination. The activities of the S1 device used in this paper increased with increasing number of insemination days (-1: $12.5{\pm}1.03/day$; 0: $12.9{\pm}1.73/day$) compared to the reference day (RD: $10.2{\pm}1.0/day$). The activities of the S2 device was also found to increase from the reference day to the insemination day (0: $63.0{\pm}3.66$) compared to the reference day (RD: $40.3{\pm}2.68$). The number of daily drinks in S1 decreased from the reference day (RD: $5.9{\pm}0.89/day$) to before the insemination day (-2: $5.6{\pm}0.98$; -1: $5.7{\pm}0.96$); +2: $6.0{\pm}0.73$). The number of daily drinks on the insemination day (0: $6.3{\pm}0.86$; +2: $6.0{\pm}0.73$) was similar to the reference day. The number of daily rumination in S2 decreased from the reference day (RD: $493.8{\pm}10.92$) to the insemination day (-1: $390.2{\pm}13.36$; 0: $354.1{\pm}16.71$).

Development of Collection Method of Arboreal Parasite Larvae for the Biological Control against Pine Needle Gall Midge, Thecodiplosis japonensis Uchida et Inouye (기생봉사육용(寄生蜂飼育用) 솔잎혹파리 유충채집(幼蟲採集)에 관(關)한 연구(硏究))

  • Chung, Sang Bae;Kim, Chul Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.3
    • /
    • pp.334-341
    • /
    • 1997
  • Artificial precipitation test with sprinkler system was carried out to develop the collection method of arboreal larvae(proctotrupoid wasps) of pine needle gall midge for biological control in 1995. Effects of larvae falling on each amount of precipitation, season of precipitation and time of precipitation of a day following artificial precipitation were examined during the period of larvae falling season. The results obtained were summarized as follows; 1. Artificial precipitation with sprinkler system was highly effective for collection of pine needle gall midge larvae and the most suitable amount of precipitation was 5.3-9.4mm; application amount and hours of water were $8,000-16.000{\ell}$ and 180-360 minutes, respectively. 2. The most effective period of larvae collection for artificial precipitation was approximately 20 days, from early through mid November, and larvae falling was 93.4% of the total number of larvae collection during this period. 3. Larvae falling from the tree crown was not affected by the artificial precipitation for the precipitation hour intervals in a day. 4. The percentage of parasitism of collected larvae of pine needle gall midge in November exceeded that of December but was not significantly different between two seasons. 5. Artificial precipitation of sprinkler system was effective in reducing 34% of gall formation after one year at collected sites of pine needle gall midge larvae. 6. The collection method of larvae following artificial precipitation was effective in reducing the expenses by 14-50% than that of collection method of infested needles.

  • PDF

A Study on the Landscape Symbolism of Tongdo-palkyung and It's Narrative Structure (통도팔경(通度八景)의 경관상징성(景觀象徵性)과 서사구조(敍事構造))

  • Rho, Jae-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.1
    • /
    • pp.27-37
    • /
    • 2010
  • This study tries to illuminate the features and values of the Buddhist temple Palkyung by closely examining the forms, structures, and meanings of Tongdo-palkyung(通度八景) handed down at Tongdosa Temple, the best among Korea's Buddhist temples with its three treasures of Buddha, law of Buddha and Buddhist monks. The findings of this study can be summarized as the following. First of all, it reveals the meaning of the geographical name Yeongchuksan(靈鷲山), located to the west of Tongdosa, and a spectacular sight spread like an eagle's spread wings, as well as its location and spatial features. In particular, the arrangement features of a number of attached hermitages clearly show Yeongchuksan's world as being a temple with buddhist treasures. The multi-layered unfolding and centripetal intention of the scenery can be perceived through the shape of the Sshangryongnongju(雙龍弄珠形), around Tongdosa and the feature of the enclosed landscape encircling the steps of Hyeolcheo(穴處) Geumganggyedan. The substances and components of Tongdopalkyung include sound-based spectacles derived from Beoneumgu(梵音具) creating sounds related to religious rituals to enlighten and redeem mankind, such as Yeongji(影池: a holy pond with shadow reflections), drum sounds, and bell sounds along with physical features like pine trees, Dae(臺), waterfalls, Dongcheon (洞天), and a glow in the sky. On the other hand, Palkyung's geographical arrangements exhibit a circular spatial formation based on the main motif as Buddhist symbolism, beginning with the 'Gukjangsangseokpyo(國長生石標)' awakening the territoriality of Tongdosa and locating the first scene 'Mupunghansong(舞風寒松)' in its introductory area, with the features of water, bridge, pine grove, and Iljumun(gate) to stand for the influx. Six other scenes including 'Anyangdongdae(安養東臺)' are placed in the sacred precincts around Daeungjeon and Geumganggyedan while the glow of sunset at 'Danjoseong' just outside the domain closes the symbolic circular formation of the Tongdopalkyung, which coincides with the development of the Mandala figure symbolizing 'Gusanpalhae(九山八海)' centered in Sumisan(須彌山). What is more, Tongdopalkyung, while excluding primary scenic elements inside the temple, maximizes the domain of the mountain's entrance and the effects of the multi-layered mountain, mountain upon mountain, by intensifying the influx and centripetal qualities. The Tongdopalkyung analysis reveals the antithesis of four-coupled scenes conveying buddhist principles and thoughts on the basis of seasons, directions, space and time to display a narrative structural landscape when viewed from the temple's territoriality. Likewise, the characteristics and porch structures of Tongdopalkyung are tools and language of symbols to both externally strengthen the temple's territoriality and to internally, maximize the desires to the Land of Happiness as well as intensify religious wishes and the Mandala's multi-layered qualities through the meanings of time and space.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Numerical analysis of FEBEX at Grimsel Test Site in Switzerland (스위스 Grimsel Test Site에서 수행된 FEBEX 현장시험에 대한 수치해석적 연구)

  • Lee, Changsoo;Lee, Jaewon;Kim, Geon-Young
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.359-381
    • /
    • 2020
  • Within the framework of DECOVALEX-2019 Task D, full-scale engineered barriers experiment (FEBEX) at Grimsel Test Site was numerically simulated to investigate an applicability of implemented Barcelona basic model (BBM) into TOUGH2-MP/FLAC3D simulator, which was developed for the prediction of the coupled thermo-hydro-mechanical behavior of bentonite buffer. And the calculated heater power, temperature, relative humidity, total stress, saturation, water content and dry density were compared with in situ data monitored in the various sections. In general, the calculated heater power and temperature provided a fairly good agreement with experimental observations, however, the difference between power of heater #1 and that of heater #2 could not captured in the numerical analysis. It is necessary to consider lamprophyre with low thermal conductivity around heater #1 and non-simplified installation progresses of bentonite blocks in the tunnel for better modeling results. The evolutions and distributions of relative humidity were well reproduced, but hydraulic model needs to be modified because the re-saturation process was relatively fast near the heaters. In case of stress evolutions due to the thermal and hydraulic expansions, the computed stress was in good agreement with the data. But, the stress is slightly higher than the measured in situ data at the early stage of the operation, because gap between rock mass and bentonite blocks have not been considered in the numerical simulations. The calculated distribution of saturation, water content, and dry density along the radial distance showed good agreement with the observations after the first and final dismantling. The calculated dry density near the center of the FEBEX tunnel and heaters were overestimated compared with the observations. As a result, the saturation and water content were underestimated with the measurements. Therefore, numerical model of permeability is needed to modify for the production of better numerical results. It will be possible to produce the better analysis results and more realistically predict the coupled THM behavior in the bentonite blocks by performing the additional studies and modifying the numerical model based on the results of this study.

Characterization of an Ion Channel Prepared from Tomato Roots and Inhibitory Effects by Heavy Metal Ions (토마토 뿌리조직에서 분리한 이온채널의 중금속에 의한 저해)

  • Shin, Dae-Seop;Han, Min-Woo;Kim, Young-Kee
    • Applied Biological Chemistry
    • /
    • v.47 no.4
    • /
    • pp.390-395
    • /
    • 2004
  • In order to characterize ion channels present in tomato roots, microsomes were incorporated into an artificial lipid bilayer arranged for electrophysiological analysis. Of the five different ion channels that could be found, a channel of 450 pS conductance was found most frequently. This channel displayed subconductance states of 450, 257 and 105 pS. All subconductance states showed linear current-voltage relationships. At positive holding potentials, high frequency of transient channel openings was observed; however, at negative potentials, the open times were long and open probability high. Po was 0.83 at -40 mV. When an additional 50 mM $K^+\;or\;Na^+$ was added to the cis side of bilayer, the reversal potentials shifted in the negative direction to near -10 mV. Thus, the 450 pS cation channel selects poorly between $K^+\;and\;Na^+$. In the presence of $100\;{\mu}M$ metal ions, the channel activity was severely inhibited by $La^{3+},\;Ba^{2+},\;and\;Zn^{2+}$, and Po was decreased to 0.2 or even less. However, $Al^{3+}\;and\;Cd^{2+}$ decreased the activity by only 20%. Interestingly, each metal ion showed different kinetics of channel inhibition. While $500\;{\mu}M\;La^{3+}$ inhibited the activities of all subconductance state, 1 mM $Zn^{2+}$ inhibited all except the 105 pS state. $Cd^{2+}$ changed the gating of the channel from a long-opening state to brief transient openings even at negative holding potentials. These data represent that the metal ions may have different binding sites on the channel protein and could be useful modulators and probes to investigate structural characteristics as well as the functional roles of the 450 pS channel on the root physiology.

Experimental Study on the Hysteresis of Suction Stress in Unsaturated Sand (불포화 모래의 흡입응력 이력현상에 대한 실험적 연구)

  • Song, Young-Suk;Choi, Jin-Su;Kim, Gyo-Won
    • The Journal of Engineering Geology
    • /
    • v.22 no.2
    • /
    • pp.145-155
    • /
    • 2012
  • The matric suction and volumetric water content of Jumunin standard sand with a relative density of 60% were measured using an Automated Soil-Water Characteristic Curve (SWCC) apparatus during both drying and wetting processes. The test time for the drying process was longer than that for the wetting process, because the flow of water is likely to be protected by air trapped in voids within the soils during the drying process. Based on the matric suction and volumetric water content, the SWCC was estimated using the model proposed by van Genuchten (1980). For the drying process, the unsaturated fitting parameters ${\alpha}$, n, and m were 0.399, 8.586, and 0.884, respectively; for the wetting process, the values were 0.548, 5.625, and 8.220, respectively. The hysteresis phenomenon occurred in the SWCCs, which means the SWCC of the drying process is not matched with the SWCC of the wetting process. Using these unsaturated parameters, we estimated the Suction Stress Characteristic Curve (SSCC), based on the relationship between suction stress and the effective degree of saturation. The suction stress showed a rapid decrease when the matric suction exceeds the Air Entry Value (AEV). Therefore, the effective stress of unsaturated soils is different from that of saturated soils when the matric suction exceeds the AEV. The suction stress of the drying process exceeds that of the wetting process for a given effective degree of saturation. The hysteresis phenomenon was also recognized in SSCCs. The hysteresis phenomenon of SSCCs arises from that of SWCCs, which is induced by the ink bottle effect and the contact angle effect. In the case of a sandy slope, the suction stress is positive and acts to enhance the slope stability as the water infiltrates the ground, but is negative when the suction stress exceeds the AEV. The results obtained for the wetting process should be applied in analyses of slope stability, because the process of water infiltration into ground is similar to the wetting process.