• Title/Summary/Keyword: 시간장치

Search Result 4,177, Processing Time 0.034 seconds

Influencing Factors on File-up Stress in the Caregivers of Patients with Dementia (치매노인 가족의 누적스트레스 영향요인)

  • Seomun, Gyeong-Ae
    • 한국노년학
    • /
    • v.25 no.2
    • /
    • pp.195-209
    • /
    • 2005
  • The purpose of this study was to identify the factors influencing file-up family stress in the caregivers of patients with dementia. Data was collected by questionnaires from 102 families with a member having a dementia, at neurology departments of hospitals, temporary shelter for dementia patient, and nursing homes for the elderly. The data was analyzed using descriptive statistics, pearson correlation coefficients, and multiple regression. In results, the score of file-up stress showed a significantly negative correlation with the score of level of family hardiness(r=-.200, p=.026), social support(r=-.361, p=.004), relative and friend support(r=-.416, p=.001), and F-COPES(r=-.345, p=.048). The multiple regression analysis revealed that the most powerful predictor of file-up family stress was family cost for patients with dementia. The results contribute to the understanding of Korean family caregivers' perceptions of caregiveing. Further researches should be conducted with the consideration of Korean traditional custom that family should take care of the elderly family members.

A Study on the Application of Micro-Credentials for Vocational Competency Development Training Teachers and Instructors (직업능력개발훈련 교·강사의 자격연계형 마이크로 크리덴셜 적용 방안)

  • Miseok Yang;Ohyoung Kwon;Woocheol Kim
    • Journal of Practical Engineering Education
    • /
    • v.15 no.1
    • /
    • pp.169-181
    • /
    • 2023
  • This study was conducted to examine the remuneration curriculum of vocational ability development training teachers and instructors and to examine ways to apply micro credentials. To this end, the current status of the remuneration curriculum of vocational ability development training instructors and instructors at K University's Competency Education Development Institute, the characteristics of micro credentials, and the possibility of linking the remuneration curriculum to micro credentials are as follows. First, most of the recognition of digital certificates was positive for digital certificates such as digital credit, digital badge issuance, and recognition of the recognized qualification process of maintenance education when completing the training course. In addition, as a method of applying micro credentials to conservative education, various cases were proposed to benefit from conservative education, systematization and grading of the qualification process, and credit of the qualification process. Second, as an institutional supplement to enhance the utilization of conservative education using micro credentials, the need to expand NCS-based major conservative education, provide efficient learning contents and learning methods, and set minimum completion time. In addition, the most common response as a way to improve the understanding of teachers and instructors in vocational ability development training was the micro credential promotion plan. Third, in the role of conservative education institutions and vocational ability development training instructors and instructors, conservative education institutions mention maintaining educational quality the most, and active participation was the role of vocational ability development training instructors. Through this study, it is expected to establish a vocational training environment that can enhance expertise and provide a practical portfolio of practical competency history by linking the remuneration curriculum of vocational competency development training instructors and micro credentials.

A Study on Characteristics of Polymer Organic Hard Mask Synthesis (고분자 유기하드마스크 합성에 따른 특성에 관한 연구)

  • Woo-Sik Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.217-222
    • /
    • 2023
  • The purpose of this paper was to synthesize a polymer organic hard mask that simplifies the manufacturing process, reduces process time significantly, and thereby lowers manufacturing costs. The results of measuring residual metals through vapor refining showed that 9-Naphthalen-1-ylcarbazole(9-NC) measured 101.75ppb in the 4th zone, 2-Naphthol (2-NA) measured 306.98ppb in the 5th zone, and 9-Fluorenone(9-F) measured between 129.05ppb across the 4th and 5th zones. After passing through a filtration system, the synthesized organic hard mask measured residual metals in the range of 9 to 7ppb. Additionally, the thermal analysis indicated a decrease of 2.78%, a molecular weight of 942, carbon content of 89.74%, and a yield of 72.4%. The etching rate was measured at an average of 18.22Å/s, and the coating thickness deviation was averaged at 1.19. For particle sizes below 0.2㎛ in the organic hard mask, no particles were observed. By varying the coating speed at 1,000, 1,500, and 1,800rpm and measuring the resulting coating thickness, the shrinkage rate ranged from 17.9% to 20.8%. The coating results demonstrated excellent adhesion to SiON, and it was evident that the organic hard mask was uniformly applied.

Effect of the Impeller Rotation Speed and Inert Gas Flow Rate on Degassing Rate in the A356 Aluminum Melt (임펠러 회전속도와 불활성 가스 유량이 A356 알루미늄 용탕의 탈가스 속도에 미치는 영향)

  • Hyeok-In Kwon;Hoe-Gyung Jeong;Seong-Il Jeong;Ji-Woo Park;Min-Su Kim
    • Journal of Korea Foundry Society
    • /
    • v.43 no.6
    • /
    • pp.271-278
    • /
    • 2023
  • In the present study, A356 melt degassing experiments were conducted under various impeller rotation speed and inert gas flow rate conditions to determine changes in the melt temperature, composition and density during a degassing treatment. The melt temperature was found to decrease gradually as the degassing time increased, but a clear correlation between the impeller rotation speed or inert gas flow rate and the melt heat loss could not be confirmed. Regardless of the impeller rotation speed or inert gas flow rate, the Mg and Ti contents in the A356 melt scarcely changed, even after degassing for more than 10 minutes, while Sr contents decreased at the maximum degassing rate of 70 ppm. From a quantitative analysis of the degassing rate under each experimental condition based on the hydrogen concentration in the melt derived from the melt density and the degassing model equation, the inert gas flow rate was found to affect the degassing rate rather than the impeller rotation speed under the degassing operation condition employed in the present study.

Optimization of MRI Protocol for the Musculoskeletal System (근골격계 자기공명영상 프로토콜의 최적화)

  • Hong Seon Lee;Young Han Lee;Inha Jung;Ok Kyu Song;Sungjun Kim;Ho-Taek Song;Jin-Suck Suh
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.21-40
    • /
    • 2020
  • Magnetic resonance imaging (MRI) is an essential modality for the diagnosis of musculoskeletal system defects because of its higher soft-tissue contrast and spatial resolution. With the recent development of MRI-related technology, faster imaging and various image plane reconstructions are possible, enabling better assessment of three-dimensional musculoskeletal anatomy and lesions. Furthermore, the image quality, diagnostic accuracy, and acquisition time depend on the MRI protocol used. Moreover, the protocol affects the efficiency of the MRI scanner. Therefore, it is important for a radiologist to optimize the MRI protocol. In this review, we will provide guidance on patient positioning; selection of the radiofrequency coil, pulse sequences, and imaging planes; and control of MRI parameters to help optimize the MRI protocol for the six major joints of the musculoskeletal system.

Performance Evaluation and Analysis on Single and Multi-Network Virtualization Systems with Virtio and SR-IOV (가상화 시스템에서 Virtio와 SR-IOV 적용에 대한 단일 및 다중 네트워크 성능 평가 및 분석)

  • Jaehak Lee;Jongbeom Lim;Heonchang Yu
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.2
    • /
    • pp.48-59
    • /
    • 2024
  • As functions that support virtualization on their own in hardware are developed, user applications having various workloads are operating efficiently in the virtualization system. SR-IOV is a virtualization support function that takes direct access to PCI devices, thus giving a high I/O performance by minimizing the need for hypervisor or operating system interventions. With SR-IOV, network I/O acceleration can be realized in virtualization systems that have relatively long I/O paths compared to bare-metal systems and frequent context switches between the user area and kernel area. To take performance advantages of SR-IOV, network resource management policies that can derive optimal network performance when SR-IOV is applied to an instance such as a virtual machine(VM) or container are being actively studied.This paper evaluates and analyzes the network performance of SR-IOV implementing I/O acceleration is compared with Virtio in terms of 1) network delay, 2) network throughput, 3) network fairness, 4) performance interference, and 5) multi-network. The contributions of this paper are as follows. First, the network I/O process of Virtio and SR-IOV was clearly explained in the virtualization system, and second, the evaluation results of the network performance of Virtio and SR-IOV were analyzed based on various performance metrics. Third, the system overhead and the possibility of optimization for the SR-IOV network in a virtualization system with high VM density were experimentally confirmed. The experimental results and analysis of the paper are expected to be referenced in the network resource management policy for virtualization systems that operate network-intensive services such as smart factories, connected cars, deep learning inference models, and crowdsourcing.

Development of a Rotation Swab Pig Method for Cleaning Water Pipes (상수관의 세척을 위한 회전식 스왑피그 공법 개발)

  • Kicheol Lee;Jaeho Kim;Kisung Kim;Jeongjun Park
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.2
    • /
    • pp.63-75
    • /
    • 2024
  • Drinking water is an essential element to ensure the basic human right to live, and the quality of clean water must always be ensured. However, domestic water facilities, which were installed intensively in the early 2000s, are deteriorating. The accidents such as discoloration of water such as chromaticity and turbidity as well as leakage of substances frequently occur. However, since it is virtually impossible to replace all water pipes, the detailed standards for maintenance of water pipe network facilities established in 2021 require water pipe cleaning. The swab pig method, one of the water pipe cleaning methods, is a method of physically removing substances in pipes and is evaluated as having the highest cleaning efficiency. However, Swab is highly likely to be damaged or deformed during the cleaning process, and may even be lost. Therefore, in this study, the material of the pig was changed to a material with high compressibility, and it was made as close as possible to the inner wall of the water pipe. And, to maximize cleaning efficiency, a rotation swab pig with a rotation blade was developed. In addition, high-strength wire and winding equipment were additionally developed to eliminate the possibility of loss and to determine the location of the pig. The inlet and outlet are connected with wires, and after verifying the performance of each detailed technology, the technology was applied on a test bed with a 30m section. As a result of the application, the performance of the technology was verified by measuring the process time and evaluating applicability.

Analysis of Experiments for the Rules of Material Change Unit in 9th Grade Science Textbooks and the Development of Experiments Applying Small-Scale Chemistry (9학년 과학교과서 물질변화에서의 규칙성 단원 실험 분석과 Small-Scale Chemistry를 적용한 실험 개발)

  • Ryu, Ran-Yeong;Kim, Dong-Jin;Hwang, Hyun-Sook;Park, Se-Yeol;Lee, Sang-Kwon;Park, Kuk-Tae
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.3
    • /
    • pp.529-540
    • /
    • 2011
  • The purpose of this study was to analyze experiments for the rules of material change unit in 9th grade science textbooks and develop experiments applying small-scale chemistry (SSC). For this study, experimental methods for the precipitation experiment, water electrolysis experiment, decomposition of hydrogen peroxide experiment presented in the 9 science textbooks were analyzed. Problems and improvements that were needed were extracted by 13 science teachers performing the experiments. Experiments applying SSC were developed based on the improvements needed. Afterwards, 19 pre-service science teachers performed both the developed SSC experiments and the science textbooks' experiments. A questionnaire about merits and demerits of the experiments applying SSC was performed. According to the results of this study, most of the 9th grade science textbooks included the lead iodide precipitation experiment, water electrolysis experiment by Hoffman voltameter, and decomposition of hydrogen peroxide experiment using catalytic manganese dioxide. Improvements were needed on the quantity of reagents, time for performing experiments, and scale of experimental apparatus. Merits of the developed experiments applying SSC which used small amount of reagents were safety, easy waste material disposal, short reaction time, and reproducible experimental results. Demerits of the experiments applying SSC were difficulty in observing, decreased achievement, and lack of skill in handling small-scale apparatus. Therefore, if the experiments developed applying SSC were to be utilized in 9th grade science experiments, it will be possible to use less reagent and be able to teach and carry out reproducible experiments at the same time. Also, the reproducible experiments based on SSC will help students under stand the scientific concepts for the rules of material change unit.

Ablation Rate and Intrapulpal Temperature by Addition of Water Spray During Er:YAG Laser Irradiation (Er:YAG laser를 이용한 치아삭제시 물분사량이 삭제율과 치수내 온도변화에 미치는 영향)

  • Kim, Jung-Moon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.375-381
    • /
    • 2005
  • Er:YAG laser has been considered a promising alternative to dental drill and many researches indicate that adjustment to variable parameters, including water flow rate, pulse energy and pulse repetition rate, can be made to improve ablation ability and efficiency of the laser. Of these parameters, addition of water spray during irradiation has been thought to ablate dental hard tissue more rapidly and safely. The purpose of this study was to investigate tooth ablation amount by Er:YAG laser irradiation as related to varied water flow rates added and, ultimately to find the most effective water flow rate for ablation. In addition, the temperature change of pulp chamber during irradiation was also monitored on the irradiated and opposite pulpal walls, respectively. An Er:YAG laser with contact mode was employed. Extracted human molars were split into two pieces for ablation experiment. Pulse energies of 200 and 300 mJ with a pulse repetition rate of 20 Hz and 5 water flow rates (1.6, 3.0, 5.0, 7.0, and 10.0 ml/min) were applied. Each irradiation was performed for 3 seconds. According to these parameters, experimental groups were divided into 10 subgroups which consisted of 5 specimens. For temperature experiment, another 5 tooth-specimens were prepared in the manner that pulp chamber was open through access cavity preparation and two temperature-measuring probes were placed respectively on the irradiated and the opposite walls of pulp chamber. From the experiment on ablation amount related to different water flow rates, it was shown that the least water flow rate of 1.6 ml/min ablated more than any other water flow rates (p<0.000). When the irradiation for 3 seconds, combined with the pulse repetition time of 20Hz and the water flow rate of 1.6 ml/min was done to tooth specimen, the temperature rise was not noticeable both on the irradiated and the opposite pulpal walls (less than 3$^{\circ}C$) and there was no significant difference in temperature rise between the two pulse energies, 200 and 300 mJ. From the results of this study, it is suggested that tooth ablation with Er:YAG laser can be done effectively and safely at a energy between 200 and 300 mJ/pulse and a pulse repetition rate of 20 Hz when the lasing is conjugated with the water flow rate of 1.6ml/min.

A Study on the Shape and Movement in Dissolved Air Flotation for the Algae Removal (수중조류제거(水中藻類除去)를 위한 가압부상(加壓浮上)에 있어서 기포(氣泡)의 양태(模態)에 관한 연구(研究))

  • Kim, Hwan Gi;Jeong, Tae Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.79-93
    • /
    • 1984
  • The dissolved air flotation(DAF) has been shown to be efficient process for the removal of algae ftom water. The efficiency of DAF can be affected by the volume ratio of pressurized liquid to sample, the pressure pressurized liquid, the contact time, the appropriate coagulant and its amount, the water temperature, the turbulence of reactor, the bubble size and rising velocity etc. The purpose of this paper is to compare the practical bubble rising velocity with the theoretical one, to investigate the adhesion phenomenon of bubbles and floc, and the influence of bubble size and velocity upon the process. The results through theoretical review and experimental investigation are as follows: Ives' equation is more suitable than Stokes' equation in computation of the bubble rising velocity. The collection of bubble and algae floc is convective collection type and resulted from absorption than adhesion or collision. The treatment efficiency is excellent when the bubble sizes are smaller than $l00{\mu}m$, and the turbulence of reactor is small. In the optimum condition of continuous type DAF the volume ratio of pressurized liquid to sample is 15%, the contact time in reactor is 15 minutes, the pressure of pressurized liquid is $4kg/cm^2$ and the distance from jet needle to inlet is 30cm.

  • PDF