• Title/Summary/Keyword: 시간장치

Search Result 4,185, Processing Time 0.026 seconds

Implementation of a Data Processing Method to Enhance the Quality and Support the What-If Analysis for Traffic History Data (교통이력 데이터의 품질 개선과 What-If 분석을 위한 자료처리 기법의 구현)

  • Lee, Min-Soo;Cheong, Su-Jeong;Choi, Ok-Ju;Meang, Bo-Yeon
    • The KIPS Transactions:PartD
    • /
    • v.17D no.2
    • /
    • pp.87-102
    • /
    • 2010
  • A vast amount of traffic data is produced every day from detection devices but this data includes a considerable amount of errors and missing values. Moreover, this information is periodically deleted before it could be used as important analysis information. Therefore, this paper discusses the implementation of an integrated traffic history database system that continuously stores the traffic data as a multidimensional model and increases the validity and completeness of the data via a flow of processing steps, and provides a what-if analysis function. The implemented system provides various techniques to correct errors and missing data patterns, and a what-if analysis function that enables the analysis of results under various conditions by allowing the flexible definition of various process related environment variables and combinations of the processing flows. Such what-if analysis functions dramatically increase the usability of traffic data but are not provided by other traffic data systems. Experimantal results for cleaning the traffic history data showed that it provides superior performance in terms of validity and completeness.

Extraction of Oil from Canola Seeds with Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 캐놀라 오일 추출)

  • Hwang, Ah-Reum;Jung, In-Il;Lim, Gio-Bin;Ryu, Jong-Hoon
    • KSBB Journal
    • /
    • v.24 no.4
    • /
    • pp.367-376
    • /
    • 2009
  • In this study, two supercritical extraction systems of different scale, analytical-scale and lab-scale, were employed to investigate the extraction efficiency of canola oil from canola seeds using supercritical carbon dioxide ($SCCO_2$) as an extraction solvent. The effects of various parameters such as extraction temperature ($40{\sim}80^{\circ}C$), pressure (200~500 bar), particle size, and $SCCO_2$ flow direction on the extraction rate and yield were examined in detail. Triglycerides and fatty acids in the extracted canola oil were analyzed quantitatively by high-performance liquid chromatography and gas chromatography. The solubility values of canola oil in $SCCO_2$ could be calculated from the experimental results. Similar extraction yields were obtained from both analytical-scale and lab-scale extraction systems. The extraction rates obtained under solvent ($SCCO_2$ ) upflow conditions were found to be higher than those of solvent downflow extraction. However, the effect of $SCCO_2$ flow direction on the extraction yield was observed to be relatively insignificant.

Measurement System of Dynamic Liquid Motion using a Laser Doppler Vibrometer and Galvanometer Scanner (액체거동의 비접촉 다점측정을 위한 레이저진동계와 갈바노미터스캐너 계측시스템)

  • Kim, Junhee;Shin, Yoon-Soo;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.5
    • /
    • pp.227-234
    • /
    • 2018
  • Researches regarding measurement and control of the dynamic behavior of liquid such as sloshing have been actively on undertaken in various engineering fields. Liquid vibration is being measured in the study of tuned liquid dampers(TLDs), which attenuates wind motion of buildings even in building structures. To overcome the limitations of existing wave height measurement sensors, a method of measuring liquid vibration in a TLD using a laser Doppler vibrometer(LDV) and galvanometer scanner is proposed in this paper: the principle of measuring speed and displacement is discussed; a system of multi-point measurement with a single point of LDV according to the operating principles of the galvanometer scanner is established. 4-point liquid vibration on the TLD is measured, and the time domain data of each point is compared with the conventional video sensing data. It was confirmed that the waveform is transformed into the traveling wave and the standing wave. In addition, the data with measurement delay are cross-correlated to perform singular value decomposition. The natural frequencies and mode shapes are compared using theoretical and video sensing results.

Development of New Prototype of Mechanical Quality Assurance for Clinical Linear Accelerator (의료용 선형가속기의 기계적 점검을 위한 새로운 정도관리 프로토콜의 개발)

  • 윤형근;신교철;김기환;오영기;김진기;정동혁;김정기;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.109-113
    • /
    • 2002
  • In recent years, the radiotherapy equipment has become much more sophisticated, and with the complication comes an increased set of quality assurance (QA) responsibilities. Today's computer controlled linear accelerator requiring QA of not only the radiation integrity, but also the mechanical accuracy of the linear accelerator. The existing QA sheets are adequate for acceptance testing and commissioning but those sheets are somewhat descriptive form for routine QA. establishing the QA sheets for a facility are more efficient if the sheets could estimate the long-term stability for the result of QA. We are going to develope new prototype of mechanical QA sheet to visualize and to verify long-term stability of mechanical QA for clinical linear accelerator. The items included in mechanical QA sheet were 1) gantry rotation, 2) collimator rotation, 3) couch rotation, 4) optical distance indicator (ODI), and 5) laser alignment. We compared new prototype sheet with conventional sheet for several hospitals in Korea for those items. The QA acceptance criteria in this study mainly followed published recommendations. The contents of test for mechanical QA are the following. Confirm that the digital and/or mechanical gantry angle readouts are correct. Verify that digital and/or mechanical readouts of collimator angle agree with the true angle, as determined with the protractor. Measure the light field using a graph paper and compare with the digital readouts. Confirm digital readout accuracy. Verify that the sagittal laser, the left and right lasers, and the ceiling laser intersect at the isocenter. In the design of new QA sheet, we emphasized the representation of the long-term stability of mechanical QA by using Excel program. By using the new prototype QA sheet, we simplified and visualized the mechanical QA process, and could estimate the long-term stability of mechanical error of linear accelerator.

  • PDF

Development of Film Verification as the QA of IMRT for Advanced Hepatoma Patients (간암 환자의 세기조절 방사선치료에서 임상적응 가능한 QA 기법의 개발)

  • Kim Myung-Se
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.40-46
    • /
    • 2006
  • Hepatoma is one of 3 most common malignancies in Korea, the survival rate is not improved since last decades because of delayed diagnosis and limited treatment conditions. Radiation was one of treatment options but the impact on the survival is not remarkable. High dose exposure to target area was suggested for improved effect but low tolerance dose of normal liver tissue is the main limited factor. IMRT is the advanced form of 3DCRT, for focusing high dose on target with minimal dose to surrounding normal tissues. Motion of the tumor by respiration, cardiac pulsation and peristalsis is the main treatment harrier of IMRT for treatment of hepatoma patients. Development of QA technique for acceptable geometrical uncertainties and dose error on target volume is essential for IMRT in clinical treatment but proper QA technique is not yet developed. This study compared the verification film dosimetry with measured dose in phantom and calculated dose in planning computer on exactly same conditions of patient treatments. Within 3% dose differences between 3 groups were confirmed. We suggest that our verification QA technique is easy, economic, iterative and acceptable in clinical application for advanced hepatoma patients.

  • PDF

Model-based Gradient Compensation in Spiral Imaging (나선주사영상에서 모델 기반 경사자계 보상)

  • Cho, S.H.;Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.15-21
    • /
    • 2009
  • Purpose : A method to estimate a real k-space trajectory based on a circuit model of the gradient system is proposed for spiral imaging. The estimated k-space trajectory instead of the ideal trajectory is used in the reconstruction to improve the image quality in the spiral imaging. Materials and Methods : Since the gradient system has self resistance, capacitance, and inductance, as well as the mutual inductance between the magnet and the gradient coils, the generated gradient fields have delays and transient responses compared to the input waveform to the gradient system. The real gradient fields and their trajectory in k-space play an important role in the reconstruction. In this paper, the gradient system is modeled with R-L-C circuits, and real gradient fields are estimated from the input to the model. An experimental method to determine the model parameters (R, L, C values) is also suggested from the quality of the reconstructed image. Results : The gradient fields are estimated from the circuit model of the gradient system at 1.5 Tesla MRI system. The spiral trajectory obtained by the integration of the estimated gradient fields is used for the reconstruction. From experiments, the reconstructed images using the estimated trajectory show improved uniformity, reduced overshoots near the edges, and enhanced resolutions compared to those using the ideal trajectory without model. Conclusion : The gradient system was successfully modeled by the R-L-C circuits. Much improved reconstruction was achieved in the spiral imaging using the trajectory estimated by the proposed model.

  • PDF

An Image Management System of Frame Unit on a Hand-held Device Environments (휴대장치 환경을 위한 프레임 단위의 영상 데이터 관리 시스템)

  • Choi, Jun-Hyeog;Yoon, Kyung-Bae;Han, Seung-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.7
    • /
    • pp.29-36
    • /
    • 2008
  • This paper proposes algorithm for the system that can search for an image of a frame unit, and we implement it. A system already inserts in images after generating the cord that mechanical decoding and identification are possible. We are independent of an external noise in a frame unit, and a system to propose at these papers can search for an image recorded by search condition to include recording date, recording time, a recording place or filming course etc. This system is composed by image insertion wealth to insert data to an image to data image code generation wealth, a frame generating data image code you apply a code generation rule to be fixed in order to express to a price to have continued like data entry wealth, GPS locator values and direction price receiving an image signal, image decoding signals and an image search signal to include search condition, and to have continuity from users each of an image. Also, image decoding we decipher about the noise that was already added from the outsides in a telerecording process, a copy process or storage processes inserted in images by real time, and searching image information by search condition. Consequently we implement decoder, and provide the early system that you use, and we easily insert data code among images. and we can search. and maximization can get precision regarding an image search and use satisfaction as we use algorithm to propose at these papers.

  • PDF

The Study on the Slurry Wear Behavior of Rubber Vulcanizates (고무 소재의 슬러리 마모 거동에 관한 연구)

  • Chung, Kyung-Ho;Hong, Young-Keun;Park, Moon-Soo
    • Elastomers and Composites
    • /
    • v.46 no.1
    • /
    • pp.70-77
    • /
    • 2011
  • A new piece of test equipment, the slurry wear tester (SWT), was proposed in this study to evaluate the wear behavior of rubber vulcanizate in environmental contact with slurry. Natural rubber (NR) and chloroprene rubber (CR) were chosen as the basic matrices to test the slurry wear. The fluids used to fill the chamber of the SWT were 35% HCl and NaCl solution. The Akron abrasion test was used for comparison with SWT. According to the results of the Akron abrasion test, CR vulcanizate abraded more rapidly than NR vulcanizate under same test condition. It was found that the hysteresis of rubber was key factor contribute to the wear behavior. However, the slurry wear rate of the NR and CR vulcanizates did not change significantly, even with changes in the concentration of acid and the immersion time in both HCl and NaCl solutions; the fluid decreased the friction between the abrasive paper and the specimen. It also reduced the heat generated from repeated deformation and wear debris at the surface of the SWT's abrasion arm. Thus, these phenomena affected the wear behavior of rubber vulcanizate and caused different results in the conventional Akron abrasion test. This outcome could have resulted in an incorrect analysis if the slurry wear behavior of the rubber vulcanizate was estimated by the conventional abrasion tests, which are operated under dry conditions.

Hybrid PKI Public Certificate Security Method Based on Device ID (디바이스 ID 기반의 하이브리드 PKI 공인 인증 보안 기법)

  • Son, Young-Hwan;Choi, Woon-Soo;Kim, Ki-Hyun;Choi, Han-Na;Lee, Dae-Yoon;Oh, Chung-Shick;Cho, Yong-Hwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.5
    • /
    • pp.113-124
    • /
    • 2010
  • In this study, the hybrid authorization quotation technique is based on the device ID for the integrity of the source region guarantee of user certificate, in order to improve the convenience and security for user in the hybrid PKI certificate Mechanism for authentication. The feature of the model in which it is presented from this paper is 5. First, because the user can select the policy himself in which it matches with each authentication situation and security level, the convenience can be improved. Second, the integrity of the source region of the user certificate can be guaranteed through the comparison of the DLDI Key, that is the hash-value of the device ID. Third, the security can be improved by continuously changing an encoding, and the value of the key in which it decodes through the EOTP Key. Fourth, the index value is added to a certificate, and the storage of a certificate is possible at the Multi-Device. Fifth, since the addi the inan aratus for the integrity of the source region guarantee of a certificate is not needed, the authentication process time can be reduced and the computational load of the certificate server can be reduced also.

Changes in Allicin Contents of Garlic via Light Irradiation (광 조사에 의한 마늘의 알리신 함량 변화)

  • Jeong, Hoon;Lee, Sun-Ho;Yun, Hong-Sun;Choi, Seung-Ryul
    • Food Science and Preservation
    • /
    • v.20 no.1
    • /
    • pp.81-87
    • /
    • 2013
  • Agri-food garlic has been recognized as healthful because of its antibacterial, anticancer and antioxidant effects. As such, its consumption is steadily increasing. This study was conducted to amplify the healthful ingredient of garlic, allicin, using light irradiation. The following conclusions were drawn from the investigation of peeled garlic under various conditions like fluorescent lighting, color (green, yellow, blue and red) and ultraviolet light (UV-A, UV-B and UV-C). The allicin content increased most with the 15-second $0.129W/m^2$ (40 W) UV-B treatment of the garlic at a 700 mm distance from the light source. At the treatment of the garlic with 126 lx (40W) red light for 24 hours at a 700 mm distance from the light source, its allicin content increased from $15.15{\pm}0.25mg/g$ to $15.15{\pm}0.34mg/g$, for a 10-percent amplification effect. Therefore, it is believed that the healthfulness of garlic can be amplified through irradiation processing of its healthful ingredient, allicin, and the development of its processing unit.