• Title/Summary/Keyword: 시간복잡도

Search Result 3,671, Processing Time 0.04 seconds

Evaluation of Contrast and Resolution on the SPECT of Pre and Post Scatter Correction (산란보정 전, 후의 SPECT 대조도 및 분해능 평가)

  • Seo, Myeong-Deok;Kim, Yeong-Seon;Jeong, Yo-Cheon;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.127-132
    • /
    • 2010
  • Purpose: Because of limitation of image acquisition method and acquisition time, scatter correction cannot perform easily in SPECT study. But in our hospital, could provide to clinic doctor of scatter corrected images, through introduction of new generation gamma camera has function of simple scatter correction. Taking this opportunity, we will compare scatter corrected and non-scatter corrected image from image quality of point of view. Materials and Methods: We acquisite the 'Hoffman brain phantom' SPECT image and '1mm line phantom' SPECT image, each 18 times, with GE Infinia Hawkeye 4, SPECT-CT gamma camera. At first, we calculated each contrast from axial slice of scatter corrected and non-scatter corrected SPECT image of 'Hoffman brain phantom'. and next, calculated each FWHM of horizontal and vertical from axial slice of scatter corrected and non-scatter corrected SPECT image of '1mm line phantom'. After then, we attempted T test analysis with SAS program on data, contrast and resolution value of scatter corrected and non-scatter corrected image. Results: The contrast of scatter corrected image, elevated from 0.3979 to 0.3509. And the resolution of scatter corrected image, elevated from 3.4822 to 3.6375. p value were 0.0097 in contrast and <0.0001 in resolution. We knew the fact that do improve of contrast and resolution through scatter correction. Conclusion: We got the improved SPECT image through simple and easy way, scatter correct. We will expect to provide improved images, from contrast and resolution point of view. to our clinic doctor.

  • PDF

Induction of Apoptosis and Expression of Apoptosis-related Gene Products in Response to Radiation in Murine Tumors (방사선에 대한 종양의 반응에서 아포프토시스의 유도와 이에 관련되는 유전자 발현)

  • Seong, Jin-Sil;Hunter, Nancv;Milas, Luka
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.187-195
    • /
    • 1997
  • Purpose : To analyze the involvement of apoptosis regulatory genes p53, $p21^{wart/cip1}$ bax and bcl-2 in induction of apoptosis by radiation in murine tumors. Materials and methods : The radiation-sensitive ovarian carcinoma OCa-1, and the radiation-resistant hepatocarcinorna HCa-I were used. Tumors, 8 mm in diameter, were irradiated with 25 Gy and at various times after irradiation, ranging from 1 to 48 h, were analyzed histologically for apoptosis and by western blot for alterations in the expression of these genes. The p53 status of the tumors were determined by the polymerase chain reaction-single strand conformation polymorphism assay. Results : Both tumors were positive for wild-type p53. Radiation inducesd apoptosis in OCa-1 but not in HCa-1. Apoptosis developed rapidly, peaked at 2 h after irradiation and returned to almost the background level at 48 h In OCa-1 radiation upregulated the expression of p53, $p21^{wart/cip1}$. and the bcl-2/bax ratio was decreased. In HCa-1 radiation increased the expression of both p53 and $p21^{wart/cip1}$, although the increase of the latter was small The bcl-2/bax ratio was greatly increased. In general the observed changes occurred within a few hours after irradiation, and either preceded or coincided with development of apoptosis Conclusions : The development of apoptosis required upregulation of both p53 and $p21^{wart/cip1}$ as well as a decrease in bcl-2/bax ratio. In contrast, an increase in bcl-2/bax ratio Prevented apoptosis in the presence of upregulated p53 and $p21^{wart/cip1}$ . These findings indentified the involvement of multiple oncogenes in apoptosis regulation in vivo and demonstrate the complexity that may be associated with the use of a single oncogene assessment for Predicting the outcome of cancer therapy with cytotoxic agents.

  • PDF

Analytical Method for MCPA Residue in Brown Rice and Rice Straw by HPLC/UVD (HPLC/UVD를 이용한 현미와 볏짚 중 MCPA의 잔류분석방법 확립)

  • Yoo, Ki-Yong;Kang, Dae-Won;Choi, Yong-Hwa;Han, Seong-Soo
    • Korean Journal of Weed Science
    • /
    • v.30 no.4
    • /
    • pp.361-370
    • /
    • 2010
  • This study was carried out to establish the analytical method of MCPA residue in brown rice and rice straw by HPLC/UVD. When MCPA was extracted from sample under the pH 3.6 by adding acetone 200 mL and 1N-HCl 100 mL, the extraction efficiency was high by 87%. And purification efficiency was high by 83% when 5 mL of 1% methanol/acetonitrile was eluated by the florisil Sep-pak cartridge column. From spiking of $0.1{\mu}g\;mL^{-1}$ and $0.25{\mu}g\;mL^{-1}$ of MCPA to control sample, respectively, average recovery rate of MCPA in brown rice was 96.0% and 94.9% and that in rice straw was 92.5% and 88.2%, respectively. Precision of experiment was very high by relative standard deviation of 1.5% to 5.7%. In brown rice and rice straw treated with bentazone+MCPA (11+1.2%) of 30 kg and 60 kg per ha at 30 days after rice transplanting, respectively, maximum residue limit was under $0.05{\mu}g\;mL^{-1}$ of the recommended rate of Korean Food and Drug Administration. From the above results, the analytical procedure of MCPA in plants such as hydrolysis, saponification and derivatization were ommited, and retention time was faster and recovery rate was higher than the existed results of HPLC/UVD. Therefore, these results were greatly improved and seemed to be usefully applied for residue analysis of MCPA in plants.

A Study on the Retransmission Consent and Arbitration for the Retransmission of Terrestrial Broadcasting Signal in Japan (지상파채널의 재전송 동의와 중재 기준에 관한 연구 - 일본의 사례분석을 중심으로)

  • Kim, Kyung-Hwan
    • Korean journal of communication and information
    • /
    • v.48
    • /
    • pp.46-62
    • /
    • 2009
  • The current study attempted to review the standards of retransmisison consent and arbitration for the terrestrial broadcasting signal. The standards are based upon the principles encouraged by the MIAC(Ministry of Internal Affairs and Communications). It has been criticized that the standards of judgement for the retransimission consent and arbitration are ambiguous and arbitrary in Japan. In 2009, MIAC announced five decisions regarding the retransmission of over-the-air. The result of the current study found that the regulations of compulsory over-the-air signal retransmission have been sustained until now. The retransmission policy of the Japan government based upon three principles; localism, proper cause and copyright act. The judgment is dependent on the intrepretation of MIAC's standard about these three principles.

  • PDF

Effect of Black Garlic and Mugwort Extracts on Lipids Profile during Restraint Stress (흑마늘과 쑥 추출물이 구속스트레스를 가한 흰쥐의 체내 지질 성분에 미치는 영향)

  • Lee, Soo-Jung;Kang, Min-Jung;Shin, Jung-Hye
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.4
    • /
    • pp.577-586
    • /
    • 2013
  • This study investigated black garlic and mugwort extracts have anti-stress activity. The antioxidant activities of extracts from black garlic (BEP), mugwort (MEP), and three mixtures (MPA, 95:5; MPB, 90:10; MPC, 85:15, w/w% for BEP and MEP, respectively) were tested in vitro. DPPH and ABTS radical scavenging activities for the mixtures (MPA, MPB and MPC) were significantly elevated in a dose-dependent manner by the amount of mugwort extract. A restraint stress was imposed on six groups of Sprague-Dawley rats supplemented with an AIN-93 diet (RSC) or one of five kinds of hot water extract drinks containing (black garlic, RS1; mugwort, RS2; and mixtures of black garlic : mugwort at 95:5, RS3; 90:10, RS4, and a mixture of black garlic : mugwort : apple extract : xylitol=90.25:4.75:2:3, RS5; v/v%) for 4 weeks. The normal group was fed with the AIN-93 diet and not exposed to restraint stress. Food intake was higher in the group fed with garlic extract (RS1), while the body weight gain and food efficiency ratio did not significantly change. The total serum cholesterol content in the RS1 and RS2 groups was significantly lower than the RSC group (control), and the RS5 group was not significantly different compared to the RS3 group. The serum triglyceride content was significantly higher RS3~RS5 groups than RS1 and RS2 groups. In terms of HDL-C and LDL-C contents, AI and CRF in the serum were not significantly different between RS3 and RS5 groups. AST and ALP activities of RS1~RS5 groups were significantly lower than the RSC group. The liver total lipid and cholesterol contents of RS1~RS5 groups were significantly lower than RSC group, and triglyceride content was significantly lower in the RS1 group. Glycogen in the liver tissue was significantly higher in the RS2 and RS3 group compared to the RSC group. These results show that the intake of a mixture of black garlic and mugwort extracts may be effective in the alleviation of hyperlipidemia caused by restraint stress.

A Lower Bound Estimation on the Number of Micro-Registers in Time-Multiplexed FPGA Synthesis (시분할 FPGA 합성에서 마이크로 레지스터 개수에 대한 하한 추정 기법)

  • 엄성용
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.30 no.9
    • /
    • pp.512-522
    • /
    • 2003
  • For a time-multiplexed FPGA, a circuit is partitioned into several subcircuits, so that they temporally share the same physical FPGA device by hardware reconfiguration. In these architectures, all the hardware reconfiguration information called contexts are generated and downloaded into the chip, and then the pre-scheduled context switches occur properly and timely. Typically, the size of the chip required to implement the circuit depends on both the maximum number of the LUT blocks required to implement the function of each subcircuit and the maximum number of micro-registers to store results over context switches in the same time. Therefore, many partitioning or synthesis methods try to minimize these two factors. In this paper, we present a new estimation technique to find the lower bound on the number of micro-registers which can be obtained by any synthesis methods, respectively, without performing any actual synthesis and/or design space exploration. The lower bound estimation is very important in sense that it greatly helps to evaluate the results of the previous work and even the future work. If the estimated lower bound exactly matches the actual number in the actual design result, we can say that the result is guaranteed to be optimal. In contrast, if they do not match, the following two cases are expected: we might estimate a better (more exact) lower bound or we find a new synthesis result better than those of the previous work. Our experimental results show that there are some differences between the numbers of micro-registers and our estimated lower bounds. One reason for these differences seems that our estimation tries to estimate the result with the minimum micro-registers among all the possible candidates, regardless of usage of other resources such as LUTs, while the previous work takes into account both LUTs and micro-registers. In addition, it implies that our method may have some limitation on exact estimation due to the complexity of the problem itself in sense that it is much more complicated than LUT estimation and thus needs more improvement, and/or there may exist some other synthesis results better than those of the previous work.

The analysis of physical features and affective words on facial types of Korean females in twenties (얼굴의 물리적 특징 분석 및 얼굴 관련 감성 어휘 분석 - 20대 한국인 여성 얼굴을 대상으로 -)

  • 박수진;한재현;정찬섭
    • Korean Journal of Cognitive Science
    • /
    • v.13 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • This study was performed to analyze the physical attributes of the faces and affective words on the fares. For analyzing physical attributes inside of a face, 36 facial features were selected and almost of them were the lengths or distance values. For analyzing facial contour 14 points were selected and the lengths from nose-end to them were measured. The values of these features except ratio values normalized by facial vortical length or facial horizontal length because the face size of each person is different. The principal component analysis (PCA) was performed and four major factors were extracted: 'facial contour' component, 'vortical length of eye' component, 'facial width' component, 'eyebrow region' component. We supposed the five-dimensional imaginary space of faces using factor scores of PCA, and selected representative faces evenly in this space. On the other hand, the affective words on faces were collected from magazines and through surveys. The factor analysis and multidimensional scaling method were performed and two orthogonal dimensions for the affections on faces were suggested: babyish-mature and sharp-soft.

  • PDF

A Study on the Lime Stabilization of Livestock Waste (축산폐기물의 안정화 처리에 대한 연구)

  • Kim, Hyun-Chul;Choi, Yong-Su
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.91-99
    • /
    • 1995
  • One of alternative conventional technologies used for treatment of livestock wastes is composting process, and recently some mechanical composting processes are being practiced. It is, however, recognized the composting process also has its own limitations such as longer time requirement, and difficulties to estimate the degree of decomposition, etc. The incomplete compost contains potentially harmful materials to crops and public health due to instabilized organic contents and pathogenic organisms. The purpose of this investigation is to develop an innovative system whereby anxious livestock wastes are thoroughly stabilized and disinfected. Thus the overall management scheme should meet the following requirements. 1. A system should be in a cost-effective and environmentally sound manner. 2. Sludges must be chemically stabilized and bacteriologically safe. 3. Odor-free by product should be applied to crop land. 4. Sludges are sources of fertilizer nutrients and/or soil amendments to enhance crop production. 5. And they can be used as potential pH adjusting agent of the acidified soils. Overall effectiveness of the developed system is experimentally tested to satisfy the preset criteria and requirements. Major experiments are divided into four categories: they are 1. chemical stability test, 2. optimal condition test of stabilization process, 3. bacteriological examination and disinfection tests, and 4. deodorization tests The stabilization process is consisted of the stabilizing reaction process and the drying process. Stabilized wastes is dried by both sun dryer and rotary dryer. It is shown that an additive dosage of about g/kg solid in wastes with a minimum of 5-minutes reaction would be necessary for effective stabilization reaction. The stabilization process is consisted of the stabilizing reaction process and drying process. Stabilized wastes are dried by both sun dryer and rotary dryer. It is shown that an additive dosage of about 300g/kg solid in wastes with a minimum of 5-minutes reaction would be necessary for effective stabilization reaction. In the stabilization reaction process, the pH of wastes is lowered from initial values of 12.3 to 8.6. High pH prevents odor production and kills pathogenic organisms. Organic matter contents in the stabilized wastes are about 50% and the sum of contents of fertilizer elements such as total nitrogen, $P_2O_5$ and $K_2O$ are about 5.3%. The livestock wastes that are stabilized chemically and hygienically can be used as a good soil conditioner and/or organic fertilizer.

  • PDF

Relationship between Stomach Volume and Tumor Location in Radiation Treatment for Hepatic Tumors (간 종양의 방사선치료에서 위내용적과 종양 위치 간의 관계)

  • Jeon, Mi-Jin;Lee, Chang-Geol;Lee, Ik-Jae;Choi, Won-Hoon;Choi, Yun-Sun;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Ha, Jin-Suk;Cho, Yoon-Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.75-83
    • /
    • 2010
  • Purpose: It aims to evaluate the location change and tendency of hepatic and intrahepatic tumors according to gastric volume and change of location. Materials and Methods: It studied 9 patients with hepatic tumors who visited Gangnam Severance Hospital from March 2009 to April 2010 and who underwent CT or PET (Positron Emission Tomography) within 2 weeks before CT-simulation. The patients fasted for 6 hours before CT-simulation and drank 240~250 cc of water just before CT or PET for image fusion. Those two types of images were fused to RTP (Radiation Treatment Planning, Pinnacle 8.0h) focusing on bone structure of individual patients. Results: They drank 240~260 cc of water but their stomach volume after drinking water varied from 259.3 cc to 495.4 cc. Even though individual differences existed in the change of stomach volume before and after drinking water, the volume was increased by 130 cc (174%) on average. The change in absolute distance between the centers of tumors ranged from 0.52 cm to 3.04 cm (1.52 cm on average); from 0.1 cm to 1.35 cm (0.44 cm on average) in cranial-caudal direction; from 0.05 cm to 2.75 cm (1.22 cm on average) in left-right direction; and from 0.05 cm to 1.85 cm (0.33 cm on average) in ventral-dorsal direction. Conclusion: It is hard to predict the movement of tumors by observing stomach movement, due to great individual differences; however, it was observed that the location of hepatic tumors was right-sided as the stomach was filled with water. Thus, it is recommended to maintain the fastened state to secure the accuracy of hepatic tumor treatment. If it cannot maintain the fastened state, it is recommended to measure stomach volumes and movement in the patient to consider the movement of hepatic tumors before radiation treatment.

  • PDF

The Evaluation of Reconstructed Images in 3D OSEM According to Iteration and Subset Number (3D OSEM 재구성 법에서 반복연산(Iteration) 횟수와 부분집합(Subset) 개수 변경에 따른 영상의 질 평가)

  • Kim, Dong-Seok;Kim, Seong-Hwan;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • Purpose: Presently in the nuclear medicine field, the high-speed image reconstruction algorithm like the OSEM algorithm is widely used as the alternative of the filtered back projection method due to the rapid development and application of the digital computer. There is no to relate and if it applies the optimal parameter be clearly determined. In this research, the quality change of the Jaszczak phantom experiment and brain SPECT patient data according to the iteration times and subset number change try to be been put through and analyzed in 3D OSEM reconstruction method of applying 3D beam modeling. Materials and Methods: Patient data from August, 2010 studied and analyzed against 5 patients implementing the brain SPECT until september, 2010 in the nuclear medicine department of ASAN medical center. The phantom image used the mixed Jaszczak phantom equally and obtained the water and 99mTc (500 MBq) in the dual head gamma camera Symbia T2 of Siemens. When reconstructing each image altogether with patient data and phantom data, we changed iteration number as 1, 4, 8, 12, 24 and 30 times and subset number as 2, 4, 8, 16 and 32 times. We reconstructed in reconstructed each image, the variation coefficient for guessing about noise of images and image contrast, FWHM were produced and compared. Results: In patients and phantom experiment data, a contrast and spatial resolution of an image showed the tendency to increase linearly altogether according to the increment of the iteration times and subset number but the variation coefficient did not show the tendency to be improved according to the increase of two parameters. In the comparison according to the scan time, the image contrast and FWHM showed altogether the result of being linearly improved according to the iteration times and subset number increase in projection per 10, 20 and 30 second image but the variation coefficient did not show the tendency to be improved. Conclusion: The linear relationship of the image contrast improved in 3D OSEM reconstruction method image of applying 3D beam modeling through this experiment like the existing 1D and 2D OSEM reconfiguration method according to the iteration times and subset number increase could be confirmed. However, this is simple phantom experiment and the result of obtaining by the some patients limited range and the various variables can be existed. So for generalizing this based on this results of this experiment, there is the excessiveness and the evaluation about 3D OSEM reconfiguration method should be additionally made through experiments after this.

  • PDF