• Title/Summary/Keyword: 시간경과 전기비저항

Search Result 25, Processing Time 0.022 seconds

Time-lapse Inversion of 2D Resistivity Monitoring Data (2차원 전기비저항 모니터링 자료의 시간경과 역산)

  • Kim, Ki-Ju;Cho, In-Ky;Jeoung, Jae-Hyeung
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.4
    • /
    • pp.326-334
    • /
    • 2008
  • The resistivity method has been used to image the electrical properties of the subsurface. Especially, this method has become suitable for monitoring since data could be rapidly and automatically acquired. In this study, we developed a time-lapse inversion algorithm for the interpretation of resistivity monitoring data. The developed inversion algorithm imposes a big penalty on the model parameter with small change, while a minimal penalty on the model parameter with large change compared to the reference model. Through the numerical experiments, we can ensure that the time-lapse inversion result shows more accurate and focused image where model parameters have changed. Also, applying the timelapse inversion method to the leakage detection of an embankment dam, we can confirm that there are three major leakage zones, but they have not changed over time.

Time-lapse inversion of resistivity tomography monitoring data around a tunnel (터널 주변 전기비저항 토모그래피 모니터링 자료의 시간경과 역산)

  • Cho, In-Ky;Jeong, Jae-Hyeung;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.4
    • /
    • pp.361-371
    • /
    • 2009
  • Resistivity tomography is very effective geophysical method to find out the resistivity distribution and its change in time around a tunnel. Thus, the resistivity tomogram can provide helpful information which is necessary for the effective maintenance of the tunnel. However, an air filled tunnel severely distorts tomography data, especially when the current or potential electrode is placed near the tunnel. Moreover, the distortion can often lead to misinterpretation of tomography monitoring data. To solve these problem, we developed a resistivity modeling and time-lapse inversion program which include a tunnel. In this study, using the developed program we assured that the inversion including a tunnel gives much more accurate image around a tunnel, compared with the conventional tomogram where the tunnel is not included. We also confirmed that the time-lapse inversion of resistivity monitoring data defines well resistivity changed areas around a tunnel in time.

Static Bending 영향에 따른 Ti/Au의 전기적 특성 변화

  • Kim, Sang-Seop;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.370.2-370.2
    • /
    • 2014
  • 본 연구에서는 Bending 시간에 따른 Ti/Au의 전기적 특성 변화에 대한 실험을 진행하였다. 전기적 특성을 평가하기 위해 PET 기판 위에 Ti/Au을 Greek Bridge와 Line Bridge를 합친 Cross Bridge 형태로 증착하였고, Cross Bridge의 Line을 bending하여 시간 경과에 따른 정적인(static) bending 영향을 확인하였다. Bending은 0~100시간까지 진행하였고, Line의 width를 200, 400, 800, $1000{\mu}m$로 가변하여 시간에 따른 비저항의 변화를 측정하였다. 실험결과 Bending시간이 길어짐에 따라 비저항이 감소하였고, 일정시간에서 크게 감소하며, 그 이후에는 포화되는 경향을 보였다. 또한 Width가 증가함에 따라 비저항의 변화가 컸다. 800 um, $1000{\mu}m$에서는 bending 직후 비저항이 초기대비 약 90%까지 떨어졌으며 100시간 후에는 80%까지 감소하였다. 100시간 뒤 Width에 따라 초기대비 비저항이 78%~91%까지 감소하는 것을 확인하였다.

  • PDF

Time-lapse Inversion of 3D Resistivity Monitoring Data (3차원 전기비저항 모니터링 자료의 시간경과 역산)

  • Kim, Yeon-Jung;Cho, In-Ky;Yong, Hwan-Ho;Song, Sung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.4
    • /
    • pp.217-224
    • /
    • 2013
  • We developed a time-lapse inversion using new cross-model constraints based on change ratio and resolution of model parameters. The cross-model constraint based on change ratio imposes the same penalty on the model parameters with equal change ratio. This constraint can emphasize the model parameters with significant change regardless of their increase or decrease. The resolution cross-model constraint imposes a small penalty on the model parameters with poor resolution, but a large penalty on the model parameters with good resolution. Thus, the model parameter with poor resolution can be effectively identified in the inversion result if they are significantly changed with time. Through the numerical tests for 3D resistivity monitoring data sets, the performance of these two cross-model constraints was confirmed. Finally, for the safety estimation of a sea dyke, we applied the developed time-lapse inversion to the 3D resistivity monitoring data that were acquired at a sea dike located in western coastal area of Korea. The result of time-lapse inversion suggested that there were no significant changes at the sea dike during the monitoring period.

Application of Inversion Methods to Evaluate the State of Soft Soil using Electrical Resistivity Monitoring Data (전기비저항 모니터링 자료를 이용한 연약지반 평가를 위한 역산기법 적용 연구)

  • Ji, Yoonsoo;Oh, Seokhoon;Im, Eunsang
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.2
    • /
    • pp.104-113
    • /
    • 2014
  • Electric resistivity monitoring was applied to evaluate the soft ground in reclaimed land in order to figure out the applicability of physical prospecting. For this, electrical resistivity monitoring data were acquired for total three months and analyzed those data with independent inversion, time-lapse inversion, and 4D inversion methods. The result was compared for various inversion methods so as to figure out what showed the soft soil most properly. Moreover, drilling and CPT(Cone Penetration Test) data were also used in order to find out if each of those inversion methods could distinguish either bed rock or the soft soil clearly. And according to the result, time-lapse inversion showed less inversion artifacts than independent inversion, so it could indicate the soft soil better. If data gained for a longer period than three months are used, 4D inversion has been found to be a more efficient analysis method than the time-lapse inversion method. Electrical resistivity monitoring on the soft soil has been found to be a useful method that can analyze the spatio-temporal electric state of the ground serially.

Mortar Characterization using Electrical Resistivity Method (모르타르의 전기비저항 특성)

  • Farooq, Muhammad;Park, Sam-Gyu;Song, Young-Soo;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.2
    • /
    • pp.215-220
    • /
    • 2009
  • Cement based mortars are widely used to improve the soft ground of a dam site, highway construction, and karst voids. The mechanical properties of the mortar are well documented in literature, however very limited work is done on their physical properties such as electrical resistivity which is considered as one of the most important physical property known while improving the soft grounds. In this paper, electrical resistivity of the Portland cement mortars is examined by employing the Wenner technique. Cylindrical specimens with various water/cement ratios (w/c) ranges from 0.35, 0.45, 0.50 and 0.65 were cast and tested. The test results showed that the electrical resistivity of the mortar increases with increasing curing time and decreases with increasing water content and w/c. A reasonable, good relation was found between electrical resistivity and compressive strength of mortar.

4D Inversion of the Resistivity Monitoring Data with Focusing Model Constraint (강조 모델제한을 적용한 전기비저항 모니터링 자료의 4차원 역산)

  • Cho, In-Ky;Jeong, Da-Bhin
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.3
    • /
    • pp.139-149
    • /
    • 2018
  • The resistivity monitoring is a practical method to resolve changes in resistivity of underground structures over time. With the advance of sophisticated automatic data acquisition system and rapid data communication technology, resistivity monitoring has been widely applied to understand spatio-temporal changes of subsurface. In this study, a new 4D inversion algorithm is developed, which can effectively emphasize significant changes of underground resistivity with time. To overcome the overly smoothing problem in 4D inversion, the Lagrangian multipliers in the space-domain and time-domain are determined automatically so that the proportion of the model constraints to the misfit roughness remains constant throughout entire inversion process. Furthermore, a focusing model constraint is added to emphasize significant spatio-temporal changes. The performance of the developed algorithm is demonstrated by the numerical experiments using the synthetic data set for a time-lapse model.

Three-Dimensional Resistivity Modeling by Serendipity Element (Serendipity 요소법에 의한 전기비저항 3차원 모델링)

  • Lee, Keun-Soo;Cho, In-Ky;Kang, Hye-Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.1
    • /
    • pp.33-38
    • /
    • 2012
  • A resistivity method has been applied to wide range of engineering and environmental problems with the help of automatic and precise data acquisition. Thus, more accurate modeling and inversion of time-lapse monitoring data are required since resistivity monitoring has been introduced to quantitatively find out subsurface changes With respect to time. Here, we used the finite element method (FEM) for 3D resistivity modeling since the method is easy to realize complex topography and arbitrary shaped anomalous bodies. In the FEM, the linear elements, also referred to as first order elements, have certain advantages of simple formulation and narrow bandwidth of system equation. However, the linear elements show the poor accuracy and slow convergence of the solution with respect to the number of elements or nodes. To achieve the higher accuracy of finite element solution, high order elements are generally used. In this study, we developed a 3D resistivity modeling program using high order Serendipity elements. Comparing the Serendipity element solutions for a cube model with the linear element solutions, we assured that the Serendipity element solutions are more accurate than the linear element solutions in the 3D resistivity modeling.

Electrical Properties of B-doped ZnO Thin Films deposited by Plasma Enhanced Chemical Vapor Deposition (플라즈마 화학기상 증착법에 의해 증착된 B이 첨가된 ZnO 박막의 전기적 특성)

  • 최준영;조해석;김영진;이용의;김형준
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.1
    • /
    • pp.85-90
    • /
    • 1995
  • 본 연구에서는 투명 전극으로의 응용을 목적으로 PECVD법에 의해 증착된 B이 첨가된 ZnO 박막의 전기 및 광학적 특성을 살펴보았다. B을 첨가하지 않은 ZnO 박막은 비저항이 수 $\Omega$-cm 정도의 값을 가지고 있었으며 시간에 따른 비저항의 변화가 컸으나, 2% B2H6을 5-16sccm의 유량범위에서 첨가한 경우에는 5-9X10-2 $\Omega$-cm의 비저항을 가지고 시간 경과에 따른 비저항의 변화가 아주 작은 ZnO 박막을 얻을 수 있었다. Van der Pauw법에 의한 Hall 계수의 측정 결과에 의하면, B을 첨가하지 않은 ZnO 박막의 전자 농도는 1017/㎤정도였으나 B을 첨가함으로써 최고 1020/㎤까지 증가하였다. 그러나 B이 첨가되기 전에는 박막의 전하 나르게 이동도가 $4extrm{cm}^2$/V.sec 이었으나, B참가에 의해 $0.7\textrm{cm}^2$/V.sec 이하로 감소하였다. B을 첨가한 경우와 첨가하지 않은 경우의 ZnO 박막은 모두 가시광성영역에서 90%이상의 광투과율을 가지고 있었으며, B을 첨가한 경우는 전자농도가 증가함에 따라 광학적 밴드 갭이 3.3eV로부터 3.55eV로 증가하는 거동을 보였다.

  • PDF

Time-Lapse Electrical Resistivity Structures for the Active Layer of Permafrost Terrain at the King Sejong Station: Correlation Interpretation with Vegetation and Meteorological Data (세종과학기지 주변 영구동토의 활동층에 대한 시간경과 전기비저항자료의 해석: 기상 및 식생 자료와의 연계해석)

  • Kim, Kwansoo;Lee, Joohan;Lee, Eungsang;Ju, Hyeontae;Hyun, Chang-Uk;Park, Sang-Jong;Kim, Ok-Sun;Lee, Sun-Joong;Kim, Ji-Soo
    • Economic and Environmental Geology
    • /
    • v.53 no.4
    • /
    • pp.413-423
    • /
    • 2020
  • Over the wide area, King Sejong Station and the nearby land are uncovered with snow and ice conditions. Therefore, the active layer on the permafrost has been formed to be much thicker than the other Antarctica region. Electrical resistivity survey of Wenner and dipole-dipole arrays was undertaken at a series of time in the freezing season at the King Sejong Station to delineate subsurface structure and to monitor active layer in permafrost terrain. Time-lapse resistivity structures are well in terms of the vegetation distribution, ground surface temperature, and snow depth. Horizontal high resistivity belt(>1826 Ωm) at very shallow depth is thickening with the lapse of time, probably caused by the freezing of the water in the pore spaces with decrease of ground temperature. Subsurface structures for the area of low snow-cover and vegetated zone area are comprised of 0~0.5 m deep high-resistive gravel-rich soil, 0.5~3 m deep low-resistive active layer, and the underlying permafrost. In contrast, the unvegetated area and high snow-buildup is characterized with high resistivities larger than approximately 2000 Ωm due to freezing of the soil throughout the year. Data interpretation and correlation schemes explored in this paper can be applied to confirm the active layer, which is expected to get thinner in additional survey during the thawing season.