• Title/Summary/Keyword: 슬리브 길이

Search Result 24, Processing Time 0.024 seconds

Design and Trend Analysis According to the Application Field of Monopole Antenna with Sleeve Structure (슬리브 구조를 갖는 모노폴 안테나의 활용분야에 따른 설계와 동향분석)

  • Kang, Sang-Won;Byeon, Mi-Kyeong;Lee, Shin-Hee;Choe, Gwang-Je
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.135-141
    • /
    • 2020
  • This paper summarizes the data of a monopole antenna with a sleeve structure that can be applied in various ways. Sleeve monopole antennas have broadband characteristics and are used for multi-frequency applications. The sleeve monopole antenna is composed of a vertical conductor, which is a radiator, and a sleeve having the same structure as a coaxial cable. The sleeve acts as a radiator and an open stub. The length of the sleeve should be 1/3~2/3 of the total length of the antenna. A monopole antenna having a sleeve structure is applicable to a vehicle wiper antenna. In addition, the case of applying this antenna to a broadband sleeve antenna using a loading coil, a broadband printed sleeve monopole antenna for an ISM band, a gap sleeve and a double sleeve, and a UWB planar monopole antenna using half cutting was summarized and analyzed in terms of structure and broadband.

A Study on the Flow Characteristics of a Sleeve-Jointed Adjusting Piece (슬리브 이음된 조정관에서의 유동 특성에 관한 연구)

  • Lee, Chang-Yong;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.145-152
    • /
    • 2021
  • The purpose of this study was to determine the optimal distances between pipes to minimize the pressure loss and turbulent intensity. This was accomplished by investigating the distances between sleeve-jointed pipes and the flow changes in pipes based on variations in the Reynolds (Re) number when installing adjusting pieces for the pipes. When the thickness tp of the sleeve-jointed piping was fixed at 5 mm and the pipe lengths Lp were 10, 50, 100, and 200 mm, the correlations with the velocity of the sleeve-jointed part, pressure distribution, length of the reattachment point in the recirculation area, and Re number were analyzed. The flow characteristic of the sleeve-jointed part from a laminar to a turbulent flow region was determined by setting the Re range to 200 ≤ Re ≤ 5,000. This was done by utilizing Ansys Fluent 18.1, which is a commercial program. The enlargement and contraction ratios of the sleeve-jointed part were 1.2 and 0.83, respectively, and the turbulent intensity of the sleeve downstream edge and pressure change both increased as the Re number increased while Lp remained constant. The fact that the flow on the sleeve wall surface was disturbed by tp resulted in losses in velocity energy. Therefore, the edge of the sleeve-jointed part was also effected. When Lp was 10 mm or less, the turbulent intensity of the edge part did not change significantly as the Re number increased. The reattachment point in the recirculation area did not appear at Lp of 10 mm or less and was not affected by the vortex. In the case of 3,000 ≤ Re, the reattachment length of the wall surface of the sleeve-jointed part was nearly constant as Lp increased.

Performance Evaluation of Post-installed Anchor according to Sleeve Length and Header Length (슬리브 및 헤드 길이에 따른 후설치 앵커의 인발성능평가)

  • Hur, Moo-Won;Chae, Kyoung-Hun;An, Yeong-Seung;Park, Tae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.2
    • /
    • pp.8-15
    • /
    • 2021
  • This study presents post-installed anchors whose heads and extension sleeves are improved. The optimal lengths of the extension sleeves and headers were analytically determined by simulations. As a result of analysis using Finite element method (FEM), 9.0mm and 3.0mm were determined as the optimal lengths of sleeves and headers respectively. In pull-out tests using the improved post-installed anchors, all specimens satisfied the coefficient of variation of 15%. Comparing the pull-out strengths of existing anchors and the improved anchors, it was increased by 1.25 times for anchors embedded with a depth of 50mm, and 1.54 times for 70mm. In the cases of high-strength concrete, the strengths were increased by 1.28 and 1.55 times for 50mm and 70mm respectively. Moreover, as a result of shear tests, the improved anchors perform the greater strength of 1.38 times than the existing anchors.

Analytical and Experimental Studies on Splice Sleeves for SD500 Rebars (SD500 철근용 충전식 슬리브 철근이음에 대한 해석 및 실험적 연구)

  • Oh, Young-Hun;Moon, Jeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.165-173
    • /
    • 2013
  • Splice sleeves for HD25 and HD32 rebars with yield strength 500 MPa were studied experimentally and analytically. The shapes of sleeve was examined with nonlinear finite element analyses. A total of 18 specimens were tested with test variables of rebar types, sleeve lengths, mortar compressive strengths, and rebar development lengths. Three identical specimens per each variable were tested in order to prevent any test errors. After tests, numerical studies with a nonlinear finite element method were conducted to evaluate the test results. Experimental studies with 18 specimens showed that the sleeves of this study satisfies the code requirement. It was found that the strength of mortar and the bar development length within the sleeves did not affect to the load-carrying capacity of sleeves.

An Experimental Study on the Performance of Compression-type Anchor with various inner shapes for CFRP Tendons (CFRP 긴장재용 압착식 정착구의 내부형상별 정착성능 실험 연구)

  • Jung, Woo-Tak;Lee, Seung-Joo;Park, Young-Hwan;Hwang, Geum-Sic
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.321-324
    • /
    • 2008
  • This paper presents the results of the performance of compression-type anchor for CFRP tendon. As the results of previous tests, the principal variables for enhancing performance of anchor were sleeve dimensions, inserts, compression pressure, etc. A total of 18 specimens were tested for the performance of compression-type anchor with various inner shapes. Test results revealed that the length of sleeve increased along with the performance of anchor up to 18-22%. Also, the performance of anchor was susceptible to the length of sleeve compared to the surface treatment with the oxide.

  • PDF

Development of Non-Shrink Mortar Grouting Type Splice Sleeve (무수축 모르타르 충진형 슬리브 개발)

  • Lee, Young-Ho;Song, Jae-Joon;Cho, Jae-Young;Kim, Do-Hak
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.67-73
    • /
    • 2011
  • This study aims to develop an economical precast hollow concrete column with high constructability which consists of only splice sleeve and general reinforcing bar without using PC tendons in order to reduce the construction period and cost. With this purpose, this study performed the finite element analysis and tension test by using some variables such as length of sleeve, diameter of rebar and curing method for suggesting a grouting type splice sleeve which is a new type joint rebar and developing an optimized splice sleeve. As a result, the analysis on the tension performance of splice sleeve did not show any destruction caused by pull-out in reinforcing bar but it only occurred destruction of tension bar or bolt shear rupture from the mechanical defect of sleeve. Therefore, the experiment showed high performance in tension of the suggested splice sleeve and verified the application of precast hollow concrete column.

A Study on the Equations for Load Carrying Capacities of Concrete Filled tubular Square Column-to-Beam Connections with Combined Cross Diaphragm and Sleeves (복합십자형 CFT 기둥-보 접합부의 내력식에 관한 연구)

  • Choi, Sung Mo;Jung, Do Sub;Kim, Dae Joong;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.419-429
    • /
    • 2005
  • The objective of this study is to clarify the structural features of members consisting of a connection, as part of the previous study on the CFT column-to-beam tensile connection with a combined cross diaphragm. This connection has the following merits: it evenly distributes the stress on the beam flange and the diaphragm and reduces the stress concentration by improving the stress transfer route and restraining the abrupt deformation of the diaphragm. Finite element analysis was performed to find out the stress transfer through the sleeve, which is an important member of the connection with a combined cross diaphragm. The length and thickness of the sleeve were used as variables for the analysis. The analysis results showed that the length and thickness of the sleeve did not influence the capacity of the connection and played the role of a medium for the transfer of the stress from the diaphragm to the filled concrete. It was proposed that the appropriate length of the sleeve have the same value as the diameter of the sleeve and that the appropriate ratio of the sleeve diameter to the sleeve thickness be 20. Two equations for the evaluation of the load carrying the capacity of the connection were also proposed through the modification of the evaluation equation suggested in the previous study.

Implementation of Broadband Printed Sleeve Monopole Antenna (광대역 프린티드 슬리브 모노폴 안테나의 구현)

  • Choe, Gwang-Je;Kang, Sang-Won
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.245-250
    • /
    • 2014
  • This paper presents the broadband printed sleeve-monopole antenna implementing the sleeve monopole structure in the form of PCB. In the proposed antenna, the antenna performance was improved by the diameter variation of the radiator, the length variation of the sleeve, and the variation of the diameter of the sleeve conductor. HFSS simulator of ANSYS corp. was used in order to confirm the antenna parameter characteristic. According to the simulation results, the VSWR was less than 2 for the range of 2.12GHz~3.18GHz. The frequency bandwidth is 1.08GHz. The frequency range of the actual fabricated antenna was 2.0GHz~3.55GHz, the frequency bandwidth is 1.55GHz. The maximum gain was 1.64dBi. The proposed antenna was $56{\times}5{\times}1.6mm$ in size. The utilization possibility of the broadband printed sleeve-monopole antenna could be confirmed according to compare and analyze the simulation and measurement data.

The Effects of Knee Sleeve with a Stimulation of Golgi Tendon Organ on One Leg Standing and Proprioception (무릎 슬리브 착용과 골지 건 기관 자극이 한 발 서기 동작과 고유수용성 감각에 미치는 영향)

  • Jeong, BoRa;Chang, YoonHee;Kim, GyuSeok;Ryu, JeiCheong;Ko, Chang-Yong
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.323-330
    • /
    • 2017
  • Knee sleeve has been used for prevention of sport injuries as well as rehabilitation. To investigate prevention of sport injuries of knee sleeve, it is important to evaluate balance associated with proprioception. The aim of this study was to evaluate the effects of a knee sleeve with a pad that stimulate to golgi tendon organ (GTO_PAD) on proprioception and balance ability. Five healthy males were participated for the study. They were asked to reenact target angle with Biodex and perform one leg standing with knee sleeve and knee sleeve with GTO_PAD. There was no significant difference in %Target angle, but the value of %Target angle was higher in subjects wearing knee sleeve with GTO_PAD than only knee sleeve, except for one subject. During one leg standing, time duration was increased in subjects wearing knee sleeve with GTO_PAD. The length of center of pressure in x-axis (COPx) and COP in y-axis (COPy) were decreased when wearing knee sleeve with GTO_PAD (COPx : $162.06{\pm}58.99mm$ in knee sleeve vs. $149.03{\pm}45.30mm$ in knee sleeve with GTO_PAD, COPy : $310.79{\pm}115.89mm$ in knee sleeve, $291.57{\pm}76.53mm$ in knee sleeve with GTO_PAD). There was significant differences in INI_transition, steady, and LAT_transition phase (all, p < 0.05). These findings support that wearing knee sleeve with GTO_PAD might enhance proprioception and balance.

Experimental Studies on Bond and Splice Performance of Splice Sleeve for Connecting Rebar (철근연결용 스플라이스 슬리브의 이음 및 부착성능에 대한 실험적 연구)

  • Kang, Duk Man;Park, Yong Gul;Lee, Hyeon Gi;Moon, Do Young
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.257-264
    • /
    • 2017
  • The PC (Precast Concrete) construction method is a technique where concrete members that have been produced in a plant are constructed on site. Thus, continuity and secure integration of a structure that can be obtained by connecting rebars at splicing joint for PC members are the main areas of concern for this method. To evaluate the splicing and bonding performance according to application of a splice sleeve for connecting rebar in this research study, the diameter of rebar, development length, grouting strength etc. were set as variables. The performance and stiffness of splicing according to the development length of grout strength were measured and evaluated. In addition, by conducting comparative analysis on each of the variables, the factors that affected the splice sleeve for connecting rebar were discussed. The results confirmed that the strength and stiffness of the splice sleeve for connecting rebar were significantly affected by the development length while the increase in performance according to grout strength was not as significant.