Analytical and Experimental Studies on Splice Sleeves for SD500 Rebars  

Oh, Young-Hun (Dept. of Architecture, Konyang University)
Moon, Jeong-Ho (Division of Architecture, Hannam University)
Publication Information
Journal of the Korea Concrete Institute / v.25, no.2, 2013 , pp. 165-173 More about this Journal
Abstract
Splice sleeves for HD25 and HD32 rebars with yield strength 500 MPa were studied experimentally and analytically. The shapes of sleeve was examined with nonlinear finite element analyses. A total of 18 specimens were tested with test variables of rebar types, sleeve lengths, mortar compressive strengths, and rebar development lengths. Three identical specimens per each variable were tested in order to prevent any test errors. After tests, numerical studies with a nonlinear finite element method were conducted to evaluate the test results. Experimental studies with 18 specimens showed that the sleeves of this study satisfies the code requirement. It was found that the strength of mortar and the bar development length within the sleeves did not affect to the load-carrying capacity of sleeves.
Keywords
splice sleeve; rebar type; development length; mortar strength; nonlinear analysis;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Architectural Institute of Korea, Building Structure Design Code, 2009, 769 pp.
2 ACI Committee, 318, Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary, American Concrete Institute, Farmington hills, Michigan, 2008, 473 pp.
3 Kim, H. K., "Study on Load Transfer Process and Design of Mortar Grouted Splice Sleeve," Journal of the Architectural Institute of Korea, Vol. 20, No. 12, 2004, pp. 19-26.   과학기술학회마을
4 Daedong MS and Kangwon University, Development of Splice Sleeves for SD500 Rebars, 2007, 124 pp.
5 Ahn, B. I., Kim, H. K., and Park, B. M., "Confining Effect of Mortar Grouted Splice Sleeve on Reinforcing Bar," Journal of the Korea Concrete Institute, Vol. 15, No. 1, 2003, pp. 102-109.   과학기술학회마을   DOI   ScienceOn
6 Kim, H. K., "Comparative Evaluation of Ductility in Mechanical Sleeve Reinforcing Bar Splice Filling High- Strength Mortar," Journal of the Architectural Institute of Korea, Vol. 28, No. 7, 2012, pp. 41-48.
7 Kim, H. K., "Analysis about the Estimation Method of Failure Mode in Steel Pipe Sleeve Splice," Journal of the Regional Association of Architectural Institute of Korea, Vol. 12, No. 4, 2010, pp. 279-286.
8 Kim, H. K., "Evaluation on Stiffness of Mechanical Sleeve Bar Splice Filling High-strength Mortar Under Monotonic Loading," Journal of the Korea Institute for Structural Maintenance and Inspection, Vol. 16, No. 4, 2012, pp. 79-88.   과학기술학회마을   DOI   ScienceOn
9 Kim, H. K., "Evaluation on Stiffness of Mortar-filled Sleeve Splice Using Estimation Method of Failure Mode," Journal of the Korea Institute for Structural Maintenance and Inspection, Vol. 16, No. 1, 2012, pp. 27-34.   과학기술학회마을   DOI   ScienceOn