• Title/Summary/Keyword: 슬루율

Search Result 5, Processing Time 0.019 seconds

Design of a Low EMI Data Transmitter for In-Vehicle Communications (낮은 전자기 간섭 특성을 가진 차내 통신을 위한 데이터 송신기 설계)

  • Jun-Young Park;Hyun-Kyu Jeon;Won-Young Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.4
    • /
    • pp.571-578
    • /
    • 2023
  • In this paper, we propose a low EMI data transmitter employing a delay-locked loop for vehicles. For the low EMI characteristic, the transmitter has been designed to have low slew rate and employs the delay-locked loop to correct the amount of change in the slew rate due to process variations. According to simulation results, the proposed transmitter which the delay-locked loop has smaller slew rate change as compared to the conventional transmitter. The proposed circuit has been designed with a 65nm process technology and the data rate is 20Mbps with a supply voltage of 1.1V. As compared to a conventional transmitter, the proposed transmitter shows that variations of the slew rate become 53.6% lower in a fast condition and 13.07% lower in a slow condition.

A Study on the Implementation of Wideband Hybrid Quadrature Polar Transmitter Platform (광대역 하이브리드 직교 폴라 송신 플랫폼 구현에 관한 연구)

  • Chang, Sang-Hyun;Lee, Il-Kyoo;Kim, Hyung-Jung;Kang, Sang-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.1A
    • /
    • pp.28-34
    • /
    • 2011
  • In this paper, we proposed the architecture of the Hybrid Quadrature Polar transmitter which has the wideband characteristics available for the SRD(Short Range Device). First, we developed the simulation environment and carried out performance degradation analysis. Second, we considered the slewrate of the VVA(Voltage Variable Attenuator), time delay between magnitude signal and phase signal and the number of bits for DAC(Digital-to-Analog Converter) as the main performance factors. Then we obtained the minimum required values to meet the transmitting performance requirements of 3GPP standards through simulation results. Based on these results, we implemented the Wideband Hybrid Quadrature Polar transmitter platform and varified the performance requirements through practical measurement.

Design of a CMOS Programmable Slew Rate Operational Amplifier with a Switched Parallel Current Subtraction Circuit (병렬전류감산기를 이용한 슬루율 가변 연산증폭기 설계)

  • 신종민;윤광섭
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.5
    • /
    • pp.730-736
    • /
    • 1995
  • This paper presents the design of a CMOS programmable slew rate operational amplifier based upon a newly proposed concept, that is a switched parallel current subtraction circuit with adaptive biasing technique. By utilizing the newly designed circuit, it was proven that slew rate was linearly controlled and power dissipation was optimized. If the programmable slew rate amplifier is employed into mixed signal system, it can furnish the convenience of timing control and optimized power dissipation. Simulated data showed the slew rate ranging from 5. 83V/$\mu$s to 41.4V/$\mu$s, power dissipation ranging from 1.13mW to 4.1mW, and the other circuit performance parameters were proven to be comparable with those of a conventional operational amplifier.

  • PDF

A Study on In-Process Performance Diagnosis of Hydraulic Servovalves - First Report : Position Control System - (유압서보밸브의 인-프로세스 성능 진단에 관한 연구 I - 유압실린더 위치제어계의 경우 -)

  • Kim S.D.;Kim K.H.;Song J.S.;Ham Y.B.;Lee J.C.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • In this paper, an in-process diagnosis method for performance of position control servo system was studied, which was based upon null bias, slew-rate ratio and delay time measurement. Slew-rate ratio and delay time were analyzed by theoretical analysis, computer simulation and experiment. As a result of these analysis, when spool of servovalve was weared, slew-rate ratio was decreased and delay time was increased.

  • PDF

Mitigation of Impulse Noise Using Slew Rate Limiter in Oversampled Signal for Power Line Communication (전력선 통신에서 오버 샘플링과 Slew Rate 제한을 이용한 임펄스 잡음 제거 기법)

  • Oh, Woojin;Natarajan, Bala
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.4
    • /
    • pp.431-437
    • /
    • 2019
  • PLC(Power Line Communication) is being used in various ways in smart grid system because of the advantages of low cost and high data throughput. However, power line channel has many problems due to impulse noise and various studies have been conducted to solve the problem. Recently, ACDL(Adaptive Cannonical Differential Limiter) which is based on an adaptive clipping with analog nonlinear filter, has been proposed and performs better than the others. In this paper, we show that ACDL is similar to the detection of slew rate with oversampled digital signal by simplification and analysis. Through the simulation under the PRIME standard it is shown that the proposed performs equal to or better than that of ACDL, but significantly reduce the complexity to implement. The BER performance is equal but the complexity is reduced to less than 10%.