• Title/Summary/Keyword: 슬러그

Search Result 38, Processing Time 0.027 seconds

Prediction of Two-phase Taylor Flow Characteristics in a Rectangular Micro-channel (사각 마이크로 채널 내 Taylor 유동 특성 예측에 대한 연구)

  • Lee, Jun Kyoung;Lee, Kwan Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.557-566
    • /
    • 2015
  • The characteristics of a gas-liquid Taylor (slug) flow in a square micro-channel with dimensions of $600{\mu}m{\times}600{\mu}m$ are experimentally investigated in this paper. The test fluids were nitrogen and water. The superficial velocities of the liquid and gas were in the ranges of 0.01 - 3 m/s and 0.1 - 3 m/s, respectively. The bubble and liquid slug lengths, bubble velocities, and bubble frequencies for various inlet conditions were measured by analyzing optical images obtained with a high-speed camera. It was found that the measured values (bubble and liquid slug lengths, bubble velocities) were not in good agreement with the values obtained using empirical models presented in the existing literature. Modified models for the bubble and liquid slug lengths and bubble velocity are suggested and shown to be in good agreement (${\pm}20$) with the measured values. Moreover, the bubble frequency could be predicted well by the relationship between the unit cell length and its velocity.

A Study on Oxygen Dissolution by Air Lift Pump (기포 펌프에 의한 산소 용해에 관한 연구)

  • Oh, S.K.
    • Journal of Power System Engineering
    • /
    • v.3 no.4
    • /
    • pp.45-50
    • /
    • 1999
  • 기포 펌프는 물과 공기 사이의 접촉 면적을 증가시켜 공기로부터 물로의 산소 용해를 높이는 기능을 가지고 있다. 이 연구에서는 기포 펌프에서 여러 가지 흐름 패턴을 설정하고, 이것을 근거로 하여 슬립모델을 확립하여, 기포 펌프의 산소 용해 특성을 조사하였다. 이 연구에서 수행한 실험 결과로부터, 산소 전달 계수는 흐름 패턴(기포 흐름, 기포-슬러그 흐름, 슬러그 흐름)에는 상당한 영향을 받았으나, 시료수의 오염 정도에 따른 영향은 그다지 크지 않음을 확인하였다. 그리고, 산소 전달양은 레이놀즈 수에 비례하여 증가하며, 산소 전달면을 증가시키기 위해서는 에어 스톤이나 디퓨저의 이용이 매우 효과적임을 확인하였다. 또한, 표면 활성 물질은 물의 오염 정도나 흐름 패턴에 관계없이 산소 전달에 큰 영향을 미침을 알 수 있었다.

  • PDF

Effect of Gas- and Liquid-injection Methods on Formation of Bubble and Liquid Slug at Merging Micro T-junction (마이크로 T자형 합류지점에서 기체 및 액체의 주입 방법이 기포 및 액체 슬러그 생성에 미치는 영향)

  • Lee, Jun Kyoung;Lee, Chi Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.227-236
    • /
    • 2016
  • In the present experimental study, the effect of gas- and liquid-injected methods on the formation of bubble and liquid slug at the merging micro T-junction of a square microchannel with dimensions $600{\mu}m{\times}600{\mu}m$ was investigated. Nitrogen and water were used as test fluids. The superficial velocities of the liquid and gas were in the range of 0.05 - 1 m/s, and 0.1 - 1 m/s, respectively, where the Taylor flow was observed. The bubble length, liquid slug length, bubble velocity, and bubble generation frequency were measured by analyzing the images captured using a high-speed camera. Under similar inlet superficial velocity conditions, in the case of gas injection to the main channel at the merging T-junction (T_gas-liquid), the lengths of the bubble and liquid slug were longer, and the bubble generation frequency was lower than in the case of liquid injection to the main channel at the merging T-junction (T_liquid-gas). On the other hand, in both cases, the bubble velocity was almost the same. The previous correlation proposed using experimental data for T_liquid-gas had predicted the present experimental data of bubble length, bubble velocity, liquid slug length, and bubble generation frequency for T_gas-liquid to be ~24%, ~9%, ~39%, ~55%, respectively.

Measurement of the Void Fraction of Slug and Bubbly Flows Using Three-Ring Impedance Meters (3-ring 임피던스미터를 이용한 슬러그류 및 기포류의 기공률 측정)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.83-88
    • /
    • 2012
  • Real slug and bubbly flows were measured using a three-ring impedance meter that can efficiently measure the void fraction of two-phase flows in a tube. First, the fitting curves between the signal from the impedance meters and the void fraction were found. The impedance meter had different fitting curves for slug and bubbly flows that had the same void fraction. An impedance meter should choose one of the two fitting curves according to the flow pattern, and the flow patterns can be recognized using the measured void fraction. The velocities and sizes of the bubbles were calculated using the void fraction curves measured by two impedance meters.

Study on the Recovery and Determination of Scandium from Tin Slag (주석슬러그에서 스칸듐원소의 정량 및 회수에 관한 연구)

  • Cha, Gi Won;Jeong, Ui Sik;Kim, Gyeong Hwan
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.98-101
    • /
    • 1990
  • A new spectrophotometric determination method of scandium in the tin slag solution has been investigated using methyl thymol blue as a colorimetric reagent. Scandium is recovered by the anion exchange resin, Amberlite IRA 400, using the mixture solution of ammonium sulfate and sulfuric acid and an eluent. The mole ratio of complex of scandium and MTB at pH 6 is 1 to 1 and the wave length of the maximum absorbance is 585 nm and the molar absorptivity at this wave length is $2.0 {\times} 10^4\;\iota{\cdot}mol^{-1}{\cdot}cm^{-1}$. When tin slag solution is loaded into anion exchange resin and eluted, ions in the solution except scandium ion are eluted rapidly and scandium is eluted lately. So scandium is recovered easily.

  • PDF

Mass Transfer Characteristics of the Carbon Dioxide-Water Slug Flow in Vertical Small-Bore Tubes (작은 직경의 수직관을 흐르는 이산화탄소-물 슬러그 유동의 물질전달 특성)

  • Lee, Kyung-Jae;Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.401-408
    • /
    • 2012
  • Volumetric mass transfer coefficient was measured with carbon dioxide and deionized water for the gas-liquid cocurrent slug flow in 2, 5 and 8 mm tubes. Measurement was repeated with and without a vertical section in an experimental setup and entrance effect was found greater for smaller tubes. Volumetric mass transfer coefficient in the vertical section was found generally a strong function of gas- and liquid-phase superficial velocities. 5 mm- and 8 mm-tube data are highly consistent each other but not with 2 mm tube.

Measurement of the Void Fraction in Slug Flow using an Optical Method (광학적 방법을 이용한 슬러그 유동의 기공률 측정)

  • Kim, Dong-Seon
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.2
    • /
    • pp.25-28
    • /
    • 2011
  • Void fraction has been measured for the gas-liquid cocurrent slug flow in 8mm vertical acrylic tube using an optical method. Bubble speed, length and period could be measured with the two sets of laser-infrared sensor modules mounted 25mm apart alongside the tube, which were designed to detect variation of light intensities with a time delay when two parallel laser beams were refracted successively by a passing bubble. It was found that the results were in good agreement with the previous studies in the literature suggesting that the method used in this study were sound and accurate.

  • PDF

Real-time measurement of void fraction and its propagation speed of slug flow with two Conductance meters (두 개의 컨덕턴스미터를 이용한 슬러그류의 기공률 및 기공률 전달속력 실시간 측정)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kang, Deok-Hong;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1569-1573
    • /
    • 2004
  • Two ring-type conductance meters were manufactured to measure void fraction and its propagation speed in slug flow. The signal of conductance meter with two rings depends on liquid temperature. Therefore a conductance meter with separated probe designed by Coney (1973), which is independent of liquid temperature, was used and experimentally proved. The manufactured conductance meters showed a good repeatability and agreement with the analytical solution by Coney (1973). From time lag between two conductance meter, we could calculate the propagation speed of void fraction.

  • PDF

CFD Modeling of Unsteady Gas-Liquid Flow in a Small Scale Air-Lift Pump (소형 공기 양수 펌프의 불규칙한 가스-액체 흐름의 CFD 모델링)

  • Li, X.S.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.16 no.1
    • /
    • pp.30-37
    • /
    • 2012
  • 공기 양수 펌프는 재생 에너지 분야, 부식 및 마모 특성의 유체의 활용 등 높은 신뢰성과 낮은 유지보수 비용을 필요로 하는 분야에서 그 사용이 증대되고 있다. 본 연구에서는 소형 공기 양수 펌프의 성능 평가 및 기초 데이터를 얻기 위한 연구로, D=0.012~0.019m, L=0.933m인 배관의 침수 깊이(${\beta}$=0.55,0.60,0.65,0.70)에 따른 수치해석을 수행하였다. 수치 해석 및 실험 결과는 유사성을 뛰었으며, 펌프의 사양과 효율은 공기의 질량 유속 비, 침수 깊이 비와 양수 배관의 길이에 관한 함수로 나타났다. 그리고 최대 물과 공기 질량 유속의 비는 각 배관에서 서로 다른 침수 깊이의 비로 나타났으며, 공기 양수 펌프의 최대 효율이 발생되는 운전조건은 슬러그(slug)와 슬러그 교반 정도(slug-churn flow regime)에 따라 나타남을 알 수 있었다.