• Title/Summary/Keyword: 슬라이스

Search Result 304, Processing Time 0.024 seconds

Prevalence and Kinetic Behavior of Escherichia coli in Smoked Duck at Changing Temperature

  • Park, Eunyoung;Kim, Yujin;Lee, Yewon;Seo, Yeongeun;Kang, Joohyun;Oh, Hyemin;Kim, Joo-Sung;Yoon, Yohan
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.6
    • /
    • pp.504-509
    • /
    • 2021
  • The objective of this study was to develop dynamic model to describe the kinetic behavior of E. coli in sliced smoked duck. E. coli was detected in 2 sliced smoked duck samples (16.7%) at 1.23 log CFU/g. The maximum specific growth rate (𝜇max) of E. coli ranged from 0.05 to 0.36 log CFU/g/h, and lag phase duration (LPD) ranged from 4.39 to 1.07 h, depending on the storage at 10-30℃, and h0 value ranged from 0.24 to 0.51. The developed model was validated with observed values obtained at 13℃ and 25℃. The model performance was appropriate with 0.130 of root mean squared error (RMSE), and the dynamic model also described properly kinetic behavior of E. coli in sliced smoked duck samples. These results indicate that E. coli can contaminate sliced smoked ducks and the models developed with the E. coli isolates are useful in describing the kinetic behavior of E. coli in sliced smoked duck.

When Evaluated Using CT Imaging Phantoms AAPM Phantom Studies on the Quantitative Analysis Method (AAPM Phantom을 이용한 CT 팬텀 영상 평가 시 정량적 분석 방법에 관한 연구)

  • Kim, Young-Su;Ye, Soo-Young;Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.592-600
    • /
    • 2016
  • AAPM CT performance for special medical equipment quality control checks using a standard phantom for evaluation, using the evaluator's subjective assessment as to minimize errors due computerized assessment program to evaluate their usefulness. Phantom for evaluation AAPM CT Performance Phantom: was used, the default shooting conditions are the same as quality control checks. And, we use IMAGE J to evaluate the program. Quantitative evaluation with CT attenuation coefficient and the noise measurement, the uniformity measurement, the slice thickness measurement, contrast resolution of the measurement, a phantom image of the spatial resolution determined by the evaluation program is evaluated as self-extracting the result after processing the image, CT uniformity measurement for the evaluation that was smaller and the standard deviation of a video image processing more uniform slice thickness measurements it is difficult to evaluate due to the difference of the ratio of the measured value of the phantom image. Contrast resolution was measured cylindrical diameter 6th evaluate the shape of a circle obtained a mean value and a standard deviation of diameters, the spatial resolution of the group of source, including acceptance criteria automatically extracted result as a result of both the number of the extracted circularIt appeared. Evaluate the source image and video processing, and video to qualitative evaluation by gross were processed video image is shown excellent results. If the evaluators in order to minimize the errors of subjective judgment based on the results of the above should be done with a quantitative evaluation and qualitative evaluation utilizes a computerized assessment program is considered that further evaluation be made more efficient.

Dose Measurements using Phantoms for Tube Voltage, Tube Current, Slice Thickness in MDCT (MDCT의 관전압, 관전류, 슬라이스 두께 변화에 따른 팬텀의 선량 분포 측정)

  • Lee, Chang-Lae;Jeon, Seong-Su;Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.139-143
    • /
    • 2007
  • The purpose of this study was to measure and evaluate radiation dose for MDCT parameters. Patient dose for various combination of MDCT parameters were experimentally measured, using MDCT (GE light speed plus 4 slice, USA), model 2026C electrometer (RADICAL 2026C, USA), standard Polymethylmethacrylate (PMMA) head and body CT dosimetry phantoms. In clinical situations, for a typical abdominal scan performed with MDCT at 120 kVp, 180 mAs, 20 mm collimation, and a pitch of 0.75 $CTDI_w,\;CTDI_{vol}$ were measured as 20.2 mGy, 26.9 mGy, respectively. When scan length is assumed as 271.3 mm, DLP and measured effective dose of the abdominal would be calculated as $729.1\;mGy{\cdot}cm$, 10.9 mSv, respectively.

  • PDF

Pre-Packing, Early Fixation, and Multi-Layer Density Analysis in Analytic Placement for FPGAs (FPGA를 위한 분석적 배치에서 사전 패킹, 조기 배치 고정 및 밀도 분석 다층화)

  • Kim, Kyosun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.96-106
    • /
    • 2014
  • Previous academic research on FPGA tools has relied on simple imaginary models for the targeting architecture. As the first step to overcome such restriction, the issues on analytic placement and legalization which are applied to commercial FPGAs have been brought up, and several techniques to remedy them are presented, and evaluated. First of all, the center of gravity of the placed cells may be far displaced from the center of the chip during analytic placement. A function is proposed to be added to the objective function for minimizing this displacement. And then, the density map is expanded into multiple layers to accurately calculate the density distribution for each of the cell types. Early fixation is also proposed for the memory blocks which can be placed at limited sites in small numbers. Since two flip-flops share control pins in a slice, a compatibility constraint is introduced during legalization. Pre-packing compatible flip-flops is proposed as a proactive step. The proposed techniques are implemented on the K-FPGA fabric evaluation framework in which commercial architectures can be precisely modeled, and modified for enhancement, and validated on twelve industrial strength examples. The placement results show that the proposed techniques have reduced the wire length by 22%, and the slice usage by 5% on average. This research is expected to be a development basis of the optimization CAD tools for new as well as the state-of-the-art FPGA architectures.

Phantom of the AAPM CT imaging evaluation Studies on the quantitative analysis method (CT 정도관리 영상의 정량적 분석방법에 관한 연구)

  • Kim, Young-su;Ko, Seong-Jin;Kang, Se-Sik;Ye, Soo-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.271-274
    • /
    • 2016
  • CT quality assurance imaging evaluation and enforcement as quantitative assessment by phantom image evaluation, assessment items include There are also contrasting the water attenuation coefficient, uniformity, noise, resolution, spatial resolution, 10mm slice thickness evaluation, contrast resolution, space for the resolution, the slice thickness evaluation, it is possible to estimate the error due to the evaluation by the subjective judgment of the tester, using a subjective error image processing program to be computed to minimize the objective evaluation. Basic recording conditions of the CT image quality control assessment is the same as special medical equipment quality control checks, the images were evaluated quantitatively using IMAGE J. For a CT attenuation coefficient, the uniformity, noise evaluation, were evaluated as CT quality control image the standard deviation of the measured value of the digital processing of image smaller and less noise uniform images than the, contrast and resolution assessment is the size of the diameter of a circle having a large the 1 inch, 0.75 inch, 0.5 inch quality if the diameter of the circle, was evaluated in the small circle in the near circle ellipse. Spatial resolution is evaluated by using a self-extracting features of an image processing program, all of the groups of members comprising the acceptance criteria to automatically extract, was evaluated to be very useful for the quantitative assessment. When CT image quality control assessment on the basis of the results such as the above, if using an image processing program to minimize the subjective judgment of the error evaluator and is determined more efficient than would be made quantitative evaluation.

  • PDF

Motion Vector Coding Using Adaptive Motion Resolution (적응적인 움직임 벡터 해상도를 이용한 움직임 벡터 부호화 방법)

  • Jang, Myung-Hun;Seo, Chan-Won;Han, Jong-Ki
    • Journal of Broadcast Engineering
    • /
    • v.17 no.1
    • /
    • pp.165-178
    • /
    • 2012
  • In most conventional video codecs, such as MPEG-2 and MPEG-4, inter coding is performed with the fixed motion vector resolution. When KTA software was developed, resolution for MVs can be selected in each slice. Although KTA codec uses a variety of resolutions for ME, the selected resolution is applied over the entire pixels in the slice and the statistical property of the local area is not considered. In this paper, we propose an adaptive decision scheme for motion vector resolution which depends on region, where MV search area is divided to multiple regions according to the distance from PMV. In each region, the assigned resolution is used to estimate MV. Each region supports different resolution for ME from other regions. The efficiency of the proposed scheme is affected from threshold values to divide the search area and the entropy coding method to encode the estimated MV. Simulation results with HM3.0 which is the reference software of HEVC show that the proposed scheme provides bit rate gains of 0.9%, 0.6%, and 2.9% in Random Access, Low Delay with B picture, and Low Delay with P picture structures, respectively.

A Visual Detecting System for The Rotation Axis of Golf Ball (영상 기반 회전 골프공 무게중심 검출 시스템)

  • Hyun, Woong-Keun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.2
    • /
    • pp.411-416
    • /
    • 2019
  • In this paper, we describe a measurement system based on vision for detecting the rotation axis of dimpled golf ball. Some golf balls have wrong rotation axis owing to bad production and scratch. A flying golf ball makes sliced or curved motion mainly to owing the wrong rotation axis of golf ball. Dimples of golf ball make a golf ball higher and more straight flying. When we hit a golf ball by driver or iron club, the dimpled ball flies straight and rotates as well. While the ball flying, the rotating axis of the ball convergence. And this makes the ball motion curved. If we hit a golf ball in direction of the rotation axis, the flying ball makes straight motion. In this paper, we develop a control system to detect convergence axis and time of flying golf ball based on vision system. To show validity of the developed system, We experimented several case for dimpled golf balls.

3D Automatic Skeleton Extraction of Coronary Artery for Interactive Shape Analysis (관상동맥의 인터랙티브 형상 분석을 위한 3차원 골격의 자동 생성)

  • Lee, Jae-Jin;Kim, Jeong-Sik;Choi, Soo-Mi
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.541-546
    • /
    • 2006
  • 3차원 관상동맥을 분석하기 위해서는 혈관의 분기점, 극단점, 혈관의 계층적 구조 관계를 함축적으로 표현하는 것이 매우 중요하다. 본 논문에서는3차원 CT 혈관 조영 영상으로부터 관상동맥의 3차원 골격을 자동으로 추출하는 방법을 개발하였다. 먼저, CT혈관 조영술에 의해 획득된 슬라이스 이미지로부터 3차원 조작 및 수술 시뮬레이션 등을 위하여 혈관의 3차원 표면에 대한 메쉬 모델을 생성한다. 생성된 메쉬 모델이 임의로 변형된 후에도 자동으로 골격을 쉽게 추출할 수 있도록 메쉬 모델을 복셀화하는 단계를 거친다. 이렇게 얻어진 복셀 모델로부터 표면복셀을 결정하고 표면 복셀로부터 객체 복셀까지의 유클리드 거리값를 계산하여 유클리드 거리맵(EDM)을 계산한다. 계산된 EDM 으로부터 객체 복셀이 가지게 되는 최대 내접 구를 계산하여 Discrete Medial Surface을 생성하게 되는데 이것은 골격의 후보가 된다. 골격의 후보집합 복셀에 대하여 Dijkstra 최단 경로 결정 알고리즘을 적용하여 골격을 자동으로 추출하게 된다. 이렇게 추출된 3차원 골격은 관상동맥 수술 시뮬레이션 등의 다양한 형상 분석에 유용하게 사용될 수 있다.

  • PDF

Quality Change of Sliced Citron (Citrus junos Sieb.) according to Browning Inhibitor Treatment (갈변방지제 처리에 따른 슬라이스 유자의 품질 변화)

  • Lee, Bo-Bae;Cho, Hye-Sung;Cho, Youn-sup;Nam, Seung-Hee
    • The Korean Journal of Food And Nutrition
    • /
    • v.33 no.4
    • /
    • pp.419-427
    • /
    • 2020
  • The purpose of this study was to investigate the qualitative changes of the citron by identifying the type of solution and addition of the solution to prevent the browning reaction of the citron in a way that inhibits the browning of the citron. The browning inhibitor solution was investigated using the individual and mixture, and the results of the degree of browning and chromaticity showed that vitamin C+NaCl+cyclodextrin (CD) had the lowest browning of 0.52. In chromaticity, the ΔE values indicate that the higher the value, the greater the change in color, and the lowest value of the vitamin C+NaCl+CD mixture was 47.0, indicating that there was minimal browning compared to other treatment. The active change of the polyphenol oxidase (PPO) in the citron increased enzyme activity as the browning progressed, and the vitamin C+NaCl+CD solution was the lowest at 68.40 μ/g among the anti-browning solution. Based on these research results, it seems that the CD mixing solution can be used as a citron browning inhibitor.

Design and performance Evaluation of Vertically-Parteitioned Parallel Signature File Method) (수직 분할 병렬 요약화일 기법의 설계 및 성능평가)

  • Kim, Jeong-Gi;Yu, Gyeong-Min;Jang, Jae-U
    • Journal of KIISE:Software and Applications
    • /
    • v.26 no.1
    • /
    • pp.66-79
    • /
    • 1999
  • 요약화일 기법은 대규모 데이터베이스 응용에서 효율적인 색인 기법으로 알려져 있으며 최근에는 보다 빠른 검색을 위해 병렬 요약화일 기법이 제안되고 있다. 본 논문에서는 효율적으로 병렬 처리를 할 수 있는 수직 분할 병렬 요약화일(Vertically-partitioned Parallel Signature File, VPSF) 기법을 제안한다. 본 VPSF는 동적인 환경에 잘 적응하도록 신장해싱을 이용하며, 검색의 효율성을 위해 프레임 슬라이스 기법을 사용한다. 실행의 편중을 없애기 위해 요약을 수직으로 분할하여 레코드를 프로세싱노드에 저장함으로써 병렬처리를 수행한다. 뿐만 아니라, 본 논문에서는 VPSF의 효율성을 보이기 위해 성능평가 모델을 제시하고, 실제의 레코드 집합을 가지고 실험을 실시하여 검색시간, 부가저장공간, 삽입시간에 대해 성능을 평가한다. 또한 레코드 집합의 분포에 다른 성능을 평가하기 위해 표준편차를 반으로 줄인 반 정규분포와 두 배로 크게 한 정규분포에 대한 성능평가를 실시한다. VPSF기법은 기존의 병렬 요약화일 기법들과 비교할 때, 실제 레코드 집합의 정규분포에서 기존의 Hamming filter 보다 평균 40% 정도 검색성능이 개선된다. 반 정규분포에서는 Hamming filter 보다 약 50% , HPSF보다 약 20% 정도 개선된 검색 성능을 보인다. 뿐만 아니라, 부가 저장공간 및 삽입시간에도 기존의 방법들보다 좋은 성능을 보인다. 일반적으로 VPSF는 데이터베이스의 레코드 크기가 서로 비슷할 때 그리고 데이터베이스의 크기가 클수록 우수한 검색 성능을 보인다.