• Title/Summary/Keyword: 스페이서

Search Result 152, Processing Time 0.027 seconds

Vibration Phenomenon with Weight Change of 6 Bundle Boltless Spacer Damper (6도체 무볼트형 스페이서 댐퍼의 중량변화에 따른 진동현상)

  • 김영달
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.9
    • /
    • pp.671-678
    • /
    • 2003
  • Spacer dampers maintain the constant gaps between each conductor in a bundle conductor-transmission line, and are installed at proper intervals to keep a line from all sorts of damages derived from the vibration energy caused by mechanical or electrical external factors. It is most important to embody a technology which considers difficulties of maintenance and repair, and has optimum elements in order to prevent accidents such as destruction by fire or the snapping of a wire by the effect of vibration phenomenon coming from transmission line. In the present thesis, therefore, the analysis of vibratory characteristics of spacer damper is set up by analytical methods such as the analysis of conductor motion's governing equation, the equation of spacer damper's motion, spacer damper-fastened wire's motion in a span, and the numerical analysis of finite difference method. Furthermore, the installation distance between spacer dampers was scrutinized by simulations of various vibration phenomena which change at any time as actual conditions do, and hereafter we will be able to analyze all kinds of vibration phenomena coming from a boltless spacer damper with 6 bundle conductor for 765 k V transmission line based on new analytical methods.

An Experimental Study on the Thermal Performance Measurement of Large Diameter Borehole Heat Exchanger(LD-BHE) for Tripe-U Pipes Spacer Apply (3중관용 스페이서를 적용한 대구경 지중열교환기의 성능측정에 관한 연구)

  • Lee, Sang-Hoon;Park, Jong-Woo;Lim, Kyoung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.581-586
    • /
    • 2009
  • Knowledge of ground thermal properties is most important for the proper design of large scale BHE(borehole heat exchanger) systems. The type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for insitu determination of design data for large diameter BHE for triple-U spacer apply. The main purpose has been to determine insitu values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a circulation pump, a inline heater, temperature sensors, flow meter, power analysis meter and a data logger for recording the temperature, fluid flow data. A constant heat power is injected into the borehole through the tripl-U pipes system of test rig and the resulting temperature change in the borehole is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective insitu values of rock thermal conductivity and borehole thermal resistance of large diameter BHE for spacer apply.

  • PDF

A Study on The Performance of a Heat Recovery Ventilator According to the Properties of Spacers (스페이서의 재질변화에 따른 전열교환기 성능변화에 관한 연구)

  • Lim, Tae-Kun;Jeon, Byung-Heon;Kim, Jong-Won;Jung, Sung-Hak;Lee, Seung-Kap;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.224-229
    • /
    • 2012
  • The importance of ventilation system is being emphasized by interest of indoor air quality. Especially, heat recovery ventilation system has attracted attention as most effective ventilation plan. Because it can reduce hazardous construction materials, indoor air pollutions, and also can reduce air conditioning energy cost. In heat recovery ventilator, the element core is the most important part. The element core is composed of liner and spacer. And liner and spacer are stacked alternately. On the Liner, heat and humidity transfer are made between supply and exhaust air. And spacer plays a role as a tunnel of exhaust and supply. In this study, we investigated and analyzed the efficiency of a heat recovery ventilator, when the spacer's properties are changed. As a result, difference spacer's properties affect an efficiency of heat recovery ventilator.

The Particle-Initiated Breakdown Characteristics on the Spacer Surface for $SF_6$GIS ($SF_6$GIS용 스페이서 표면 파티클에 의한 절연파괴 특성)

  • 김정달;이세훈
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.3-11
    • /
    • 1998
  • The influence due to particle contaminated on spacer surface is remarkable in the decreasing of dielectric strength in SF6 GIS. In relation with this problem, We studied, AC flash-over voltage characteristics and breakdown mechanism are investigated under metallic and insulating particle initiated condition in SF6 gas by varying the particle position, particle shape with a plane-plane electrode. The main results are as follows $\circled1$ Influence of the flash-over voltage decrease for particle position is lowest in mid gap and is highest in separated small gap on electrode. $\circled2$ The metallic particle shape which results in the more reduced flash-over voltage, the FOV saturation moved in to the region of low pressure. $\circled3$Insulating particle less than 0.6[mm] are not almost influenced by the flash-over Voltage.oltage.

  • PDF

Influence of Flash-over Voltage on Conductive Particle-Initiated and Solid Dielectric Barrier (고체유전체의 장벽과 도전성 파티클이 섬락전압에 미치는 영향)

  • 이용길;김동의;이세헌;김재호;김정달
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.3
    • /
    • pp.54-63
    • /
    • 1994
  • In this paper, we fixed to the needle electrode on the plate spacer fabricated the plate electrode of the gap interval 40[mm]and divided into the interval lO[mm]in the gap. When set up the particle and barrier on the material as well as spacer in the each intervaL We investigated that FOV and discharge path to AC, OC positive polarity. The results are as follow. 1) When the barrier is settled on the high potential side and the particle is hidden on the back of barrier, FaV has been increased. 2) When the particle is located on the tip of needle electrode, FaV has been decreased considembly. 3) When the particle is between electrodes. FaV has been decreased because discharge path through the particle.

  • PDF

Effect Analysis of Spacer Stiffness and Interval on Galloping of Power Transmission Lines (스페이서 강성과 간격이 송전선 갤러핑에 미치는 영향분석)

  • Oh, Yun-Ji;Sohn, Jeong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • Due to icing and snow, power transmission lines have asymmetric cross sections, and their motion becomes unstable. At this time, the vibration caused by the wind is called galloping. If galloping is continuous, short circuits or ground faults may occur. It is possible to prevent galloping by installing spacers between transmission lines. In this study, the transmission line is modeled as a mass-spring-damper system by using RecurDyn. To analyze the dynamic behavior of the transmission line, the damping coefficient is derived from the free vibration test of the transmission line and Rayleigh damping theory. The drag and lift coefficient for modeling the wind load are calculated from the flow analysis by using ANSYS Fluent. Galloping simulations according to spacer stiffness and interval are carried out. It is found that when the stiffness is 100 N/m and the interval around the support is dense, the galloping phenomenon is reduced the most.

Microstructure characterization technique of spacer garter spring coil X-750 material (스페이서 가터 스프링 코일 X-750 소재 정밀 조직 분석 방법)

  • Hyung-Ha Jin;I Seol Ryu;Gyeng-Geun Lee
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.109-118
    • /
    • 2021
  • In the periodic surveillance material test for the spacer component of fuel channel assembly in CANDU, a microstructural characterization analysis is required in addition to the mechanical property evaluation test. In this study, detailed microstructure analysis and simple mechanical property evaluation of archive spacer parts were conducted to indirectly support the surveillance test and assist in the study of spacer material degradation. We investigated the microstructural characteristics of the spacer garter spring coil through comparative analysis with the plate material. The main microstructure characteristics of the garter spring coil X-750 are represented by the fine grain size distribution, the ordering phase distribution developed inside the matrix, the high dislocation density inside the grains, and the arrangement of coarse carbides. In addition, the yield strength of the garter spring coil X-750 was indirectly evaluated to be approximately 1 GPa. We also established an analytical method to elucidate the microstructural evolution of the radioactive spacer garter spring coil X-750 based on Canadian research experiences. Finally, we confirmed the measurement technique for helium bubble formation through TEM examination on the helium implanted X-750 material.

Carbon-nanotube-based Spacer Fabric Pressure Sensors for Biological Signal Monitoring and the Evaluation of Sensing Capabilities (생체신호 모니터링을 위한 CNT 기반 스페이서 직물 압력센서 구현 및 센싱 능력 평가)

  • Yun, Ha-yeong;Kim, Sang-Un;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.24 no.2
    • /
    • pp.65-74
    • /
    • 2021
  • With recent innovations in the ICT industry, the demand for wearable sensing devices to recognize and respond to biological signals has increased. In this study, a three-dimensional (3D) spacer fabric was embedded in a single-wall carbon nanotube (SWCNT) dispersive solution through a simple penetration process to develop a monolayer piezoresistive pressure sensor. To induce electrical conductivity in the 3D spacer fabric, samples were immersed in the SWCNT dispersive solution and dried. To determine the electrical properties of the impregnated specimen, a universal testing machine and multimeter were used to measure the resistance of the pressure change. Moreover, to examine the changes in the electrical properties of the sensor, its performance was evaluated by varying the concentration, number of penetrations, and thickness of the specimen. Samples that penetrated twice in the SWCNT distributed solution of 0.1 wt% showed the best performance as sensors. The 7-mm thick sensors showed the highest GF, and the 13-mm thick sensors showed the widest operating range. This study confirms the effectiveness of the simple process of fabricating smart textile sensors comprising 3D spacer fabrics and the excellent performance of the sensors.

A Study on Variation of Properties due to Corrosion in Power Lines (전력선의 부식에 의한 물성 변화에 관한 연구)

  • Park, Geon-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.07a
    • /
    • pp.259-260
    • /
    • 2016
  • 본 논문에서는 전력선의 부식에 따른 물성 변화에 대한 확인 및 검증을 위한 연구를 수행하였다. 산업단지 및 염해지역에 설치되어진 송전선로에 사용되고 있는 강심알루미늄연선(Aluminum Conductors Steel Reinforced, ACSR)은 타 지역에 비하여 스페이서, 슬리브 등의 접속부에서의 부식 정도가 상당히 빠르게 진행된다. 따라서 현재와 같은 내용연한을 획일적으로 적용할 수 없으므로 설치된 선로의 주위 환경 및 사용되는 부하의 조건 등이 반영된 합리적인 송전선로 운용이 필요하다.

  • PDF

AC Breakdown Voltage Characteristics in $SF_6$ Gas with Spacer Under Mon-uniform Field ($SF_6$ 가스중 스페이서가 존재하는 불평등전계하에서의 교류파괴전압 특성)

  • Kim, Jung-Dal;Song, Hee-Suck;Song, Won-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.293-296
    • /
    • 1990
  • In this work, we reviewed AC break-down voltage characteristics in $SF_6$ Gas with spacer under nonuniform field, using the electrode construction of model spacer and simple protrusion. We cleared that breakdown voltage and surface flashover strongly depend on the position of spacer's insert.

  • PDF