• Title/Summary/Keyword: 스테인리스 스틸 316L

Search Result 12, Processing Time 0.031 seconds

A study on the corrosion behavior of Ni-Al electoplated 316L SS separator of molten carbonate fuel cells (Ni-Al이 전기도금된 용융탄산염 연료전지 분리판용 316L SS의 부식거동에 관한 연구)

  • 문영준;임희천;이덕열
    • 한국전기화학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.237-242
    • /
    • 2001
  • 용융탄산염 연료전지에서 분리판으로 사용되는 316L 스테인리스 스틸의 내식성을 향상시키기 위해 Ni과 Al을 전기도금법에 의해 코팅하였으며 열처리를 통해 스테인리스 스틸표면에 $Ni_2Al_3$, NiAl 등의 금속간화합물을 형성시켰다. $62mol\%Li_2CO_3-38mol\%K_2CO_3$ 전해질 내에서 100시간 동안 침지실험을 수행한 결과 Al의 도금두께가 $10{\mu}m$ 이상인 경우에는 내식성이 상당히 향상되었음을 확인하였다.

  • PDF

Corrosion resistance and cell performance of CrN-coated stainless steels as a metal bipolar plate for DMFC (CrN 코팅 STS 금속분리판의 부식 특성과 DMFC 성능 평가)

  • Lee, Se-Hee;Park, Young-Chul;Lim, Seongyop;Kim, Sang-Kyung;Jung, Doo-Hwan;Choi, Se-Young;Peck, Dong-Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.137.2-137.2
    • /
    • 2010
  • 본 연구는 스테인리스 스틸(STS)을 직접메탄올 연료전지(DMFC)용 바이폴라 플레이트에 적용하기 위한 것이다. 약산성의 연료전지 환경에서 부식저항성을 향상시키고자 오스테나이트계 STS 316L과 페라이트계 STS 430에 UBM(unbalanced magnetron) DC sputter로 CrN 코팅막을 제작하였다. CrN이 코팅된 스테인리스 스틸은 부식특성, 접촉 저항 및 접촉각 등을 측정하여 무 코팅의 스테인리스 스틸과 특성을 비교하였다. 그리고 이들 재료의 연료전지(DMFC) 적용 가능성을 알아보기 위하여 단위전지로 제작하여 연료전지 성능 등을 측정하고 평가하였다. 무 코팅 스테인리스 스틸(STS 316L, STS 430)과 CrN 코팅 스테인리스 스틸의 부식저항 특성은 동전위와 정전위 실험으로 조사하였다. 동전위 부식 실험은 -0.4~1.0 V로 0.001 M의 황산용액 또는 메탄올을 첨가하여 질소 또는 공기의 환경에서 실험을 실시하였으며, 정전위 부식 실험은 0.4 V 또는 0.6 V에서 진행하였다. 연료전지의 단전지 측정은 실제 DMFC의 운전조건에서 실시하였다. 부식실험과 단전지 실험 전/후 메탈 바이폴라 플레이트의 조직 변화는 SEM을 통해 관찰하였고, 부식산화물의 화학적 조성과 메탈 바이폴라의 표면은 EDS를 이용하여 측정하였다.

  • PDF

A Study on the Ceramic Coating of Biopsy Needle (조직생검용 Needle의 세라믹 코팅에 관한 연구)

  • Cho, Sung-Man;Chung, Hyup-Jae;Kim, Man-Tae;Rhee, Kyong-Yop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.9
    • /
    • pp.121-126
    • /
    • 2009
  • Stainless steel 316L (STS 316L) is widely used as a material of biopsy needle. However it has a side effect that tissue can be damaged by electrochemical operation between tissue and STS 316L. Many studies have been made on the ceramic coating of biopsy needle to reduce the side effect. In this study, STS 316L was coated with three bioceramics, $Al_2O_3$, $SiO_2$ and $ZrO_2$ using a RF magnetron sputtering method. The effects of ceramic coating on the electrical conductivity and coating strength of ceramic-coated STS 316L were investigated. The results showed that the electrical conductivity of ceramic-coated STS 316L was much lower than that of uncoated STS 316L. The coating strength of $ZrO_2$-coated STS 316L was 30% and 70% higher, respectively than those of $Al_2O_3$-coated STS 316L and $SiO_2_3$-coated STS 316L.

Long-Term Life Test of A Stainless Steel-Sodium Heat Pipe (스테인리스 스틸-나트륨 히트파이프의 장기 수명 시험)

  • Park, S.Y.;Jung, E.G.;Boo, J.H.;Kang, H.K.;Yoo, J.H.;Park, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1058-1062
    • /
    • 2004
  • High-temperature cylindrical stainless steel/sodium heat pipe was manufactured and tested under long-term operation. The container material was stainless steel 316L and the working fluid was sodium. The heat pipe was 25.4 mm in diameter and 1000 mm in length with a two-layer screen mesh wick. The evaporator part was 600 mm and the condenser part was 300 mm in length. Total measurement points on heat pipe were 15 points and 12 points were located in condenser part. The heat pipe was heated for 142 days(3400 hours) at $800^{\circ}C$. In the test period, the maximum temperature difference was increased from $18^{\circ}C$ o $28^{\circ}C$ and the maximum thermal resistance was as low as $0.015^{\circ}CW$.

  • PDF

Impact of Energy Density and Bead Overlap Ratio of a SUS316L Specimen Fabricated using Selective Laser Melting on Mechanical Characteristics (선택적 레이저 용융 공정으로 제작된 시편의 SUS316L 에너지밀도 및 비드 중첩률에 따른 기계적 특성 변화 분석)

  • Lee, Dong Wook;Kim, Woo Sung;Sung, Ji Hyun;Kim, Cheol;Lee, Ho Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.8
    • /
    • pp.42-51
    • /
    • 2021
  • Investigations of process parameters are essential when fabricating high-quality parts using additive manufacturing. This study investigates the change in the mechanical characteristics of a SUS316L specimen fabricated using selective laser melting based on the energy density and bead overlap ratio. The SUS316L powder particles were spherical and 35 ㎛ in size. Single-bead and hexahedral shape deposition experiments were performed sequentially. A single bead experiment was performed to obtain the bead overlap ratios for different laser parameters utilizing laser power and scan speed as experimental parameters. A hexahedral shape deposition experiment was also performed to observe the difference in mechanical properties, such as the internal porosity, surface roughness, and hardness, based on the energy density and bead overlap ratio of the three-dimensional printed part. Laser power, scan speed, overlap ratio, and layer thickness were chosen as parameters for the hexahedral shape deposition experiment. Accordingly, the energy density applied for three-dimensional printing, and the experimental parameters were calculated, and the energy density and bead overlap ratio for fabricating parts with good properties have been suggested.

Mechanical Properties on Resin of New Austrian Tunneling Coatings on Stainless Steel 316L (스테인레스강 316L 상의 New Austrian Tunneling Method Coatings의 수지에 관한 기계적 특성)

  • Lee, Jooyoub;Sung, Wanmo;Kim, Joohan;Seong, Minjeong;Kim, Ki-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.1034-1040
    • /
    • 2020
  • The mechanical properties of NATM resin of synthetic polyurethane-epoxy resin for stainless steel were measured by SEM, FT-IR, tensile properties, and specific mass loss by EIS analysis, etc. As interest in eco-friendly medium coatings increased, the Heavy duty coatings were synthesized for various metals such as stainless steel composed of Polyol, MDI, water bored Epoxy resin, filling agent, silicon surfactant, catalyst etc. The coatings of synthetic NATM resin were increased tensile strength due to various temperature change, and the low-Specific Mass Loss was measured in a highly electrolytic solution. In conclusion, the NATM coatings composed of polyurethane and waterbored Epoxy, polyurea resin were synthetic microstructure with cross linkage can be good material for coating of anticorrosion of metal substrates such as stainless steel.

Dose modeling and its Application of Ir-192 for substitution of Ralstron Brachytherapy source (Ralstron 선원대체형 Iridium-192 선원의 선량모델링과 응용)

  • 김옥배;최태진;김진희;이호준;박정호;김성규;조운갑;한현수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.131-139
    • /
    • 2000
  • We designed high dose rate Ir-192 source which was prepared for substitute the Co-60 source in Ralstron unit (Simatsu, Japan) which is supplied for cervical cancer treatment. The source dimension is 1.5 mm in a diameter and 1.5mm thickness of cylinder and encapsulated with 3 mm diameter of stainless steel(SUS316L) to substituted for the Co-60 source size. The Ir-192 source was prepared the dose model for tissue dose computation through the experimental determination of apparent activity and applied the empirical tissue correction factors extended to 20cm distance. The tissue dose model was applied the 4.69 R/cm-mCi-hr gamma constant and the ratio of energy absorption coefficient of water to that of air showed 1.112 include filteration of the self-absorptions. In this experiments, we prepared the dose computation software to clinical usefulness.

  • PDF

An Analysis on Stainless Steel for Hydrogen Generator' Pipeline Interacting with Alkaline Solution (알칼리 용액이 수소배관으로 사용되는 Stainless steel에 미치는 영향 분석)

  • Byun, Chang-Sub;Choi, Jin-Young;Lim, Soo-Gon;Hwang, Gab-Jin;Choi, Ho-Sang;Shin, Hoon-Kyu
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.3
    • /
    • pp.207-212
    • /
    • 2012
  • This study was performed to observe the change of stainless steel pipe interacting with alkaline solution. We used STS316L and STS304 as samples which were soaked in alkaline solution. We measured the samples by use of FE-SEM, EDX, SIMS to observe the surface and depth profile of both samples. The result showed that the precipitate appeared on the surface of both samples from 5 days. but the precipitate was confirmed to be decreased as time passes. but the quantitative change of precipitates at both samples was different as time passed. The EDX showed that the precipitate is Potassium from solution of Electrolysis. The result also showed that the primary elements of stainless steel pipeline and of Alkaline Solution were changed. The change of primary elements was severe between 5 days to 16 days and was stable around 40 days at both samples. The reaction of STS316L with alkaline solution was lower than STS304. We hoped that this study would be the foundation of developing the electrode of the alkaline hydrogen generator.