• Title/Summary/Keyword: 스위칭기법

Search Result 620, Processing Time 0.025 seconds

A study On the Switching Technique of Boost Converter for Harmonic Reduction (부스트컨버터의 고조파저감을 위한 스위칭 기법에 관한 연구)

  • Shon, Jin-Geun;Chu, Sun-Nam;Kim, Young-Hyuk;Lee, Sang-Cheol;Lee, Bok-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.74-78
    • /
    • 2000
  • In this paper a switching control circuit for shaping the line current and reducing the total harmonics distortion in the boost converter is presented. To solve the problems of performance degradation due to pulse waveform in the input current, the boost converter in which the harmonic distortion in the input current is reduced using a 3th harmonic-injected PWM is proposed. Finally, Simulation and experimental results of boost converter with 5[kHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

Study of ZVS-PWM Series Resonant Converter with Active-Clamp Technique (액티브 클램프 기법을 이용한 영전압 스위칭 직렬 공진형 컨버터에 관한 연구)

  • Jeon, Hee-Cheol;Kim, Yong;Jung, Kye-Cheon;Kim, Pil-Soo;Lee, Eun-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2674-2677
    • /
    • 1999
  • Resonant converters have several salient features such as high efficiency and low noise. Therefore, ZVS-PWM controlled series resonant converter with active-clamp technique is presented. The combination of an active-clamp technique and resonant circuit makes it possible to control the output voltage of the resonant converter with PWM. This new resonant converter was implemented and has achieved a good controllability. In this paper, the normal load characteristics and abnormal voltage increase in the case of the light load are analyzed. As a result, it is clarified that the stray capacitance of the transformer is a cause of the abnormal voltage increase. Then, it is confirmed that the abnormal voltage increase is suppressed by decreasing the duty ratio. ZVS condition is analyzed. The maximum efficiency of 89% is obtained for the output of 10V and 5A.

  • PDF

Half-Bridge Type Single-Stage High Power Factor AC-DC Converter (단일 전력단으로 이루어진 고역률 AC-DC 하프브리지 컨버터에 관한 연구)

  • Lee, Won-Jae;Kim, Yong;Kim, Pil-Soo;Yoon, Suk-Ho;Chang, Jung-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2678-2681
    • /
    • 1999
  • 본 논문에서는 벅-부스트 컨버터와 하프브리지 컨버터가 결합된 형태가 구성된 고역률 AC-DC 컨버터를 제안한다. 제안된 컨버터는 주회로와 제어회로를 단단으로 구성함으로써 입력역률을 개선함과 동시에 출력전압의 제어가 가능한 구조이다. 역률개선용 컨버터로 벅-부스트 컨버터를 사용함으로써 링크 캐패시터의 DC 링크전압을 입력 라인전압의 최대값 이하로 유지하여 회로의 각 소자가 받는 전압 스트레스가 감소하므로 내압이 낮은 소자를 사용하여 효율을 높일 수 있다. 비대칭 제어기법을 통해 두 스위치의 데드타임을 일정하게 유지하여 스위칭손실을 줄였고 출력단에는 동기정류기를 사용하여 정류손실을 줄임으로써 효율을 개선한다.

  • PDF

Switching Method of 3-phase Interleaved Bidirectional DC-DC Converter to Achieve High Efficiency in Wide Load Range (넓은 부하영역에서 고효율을 얻기 위한 3상 인터리브드 양방향 DC-DC 컨버터의 스위칭 기법)

  • Jung, Jae-Hun;Seo, Bo-Gil;Sun, Daun;Nho, Eui-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1306-1314
    • /
    • 2015
  • This paper deals with a switching method of a three-phase interleaved bidirectional DC-DC converter to obtain high efficiency in wide load range. The proposed soft-switching method provides ZVS and ZCS at turn-on, and ZVS at turn-off of the switch as well as considerably reduced conduction loss in light load. Simulation and experiment are carried out with a bidirectional DC-DC converter having the power rating of 3 [kW], and those results show the validity of the proposed switching method.

Diagnosis of Multiple Crosstalk-Faults in Optical Cross Connects for Optical Burst Switching (광 버스트 스위칭을 위한 광 교환기에서의 다중 누화고장 진단기법)

  • 김영재;조광현
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.3
    • /
    • pp.251-258
    • /
    • 2003
  • Optical Switching Matrix (OSM) or Optical Multistage Interconnection Networks (OMINs) comprising photonic switches have been studied extensively as important interconnecting blocks for Optical Cross Connects (OXC) based on Optical Burst Switching (OBS). A basic element of photonic switching networks is a 2$\times$2 directional coupler with two inputs and two outputs. This paper is concerned with the diagnosis of multiple crosstalk-faults in OSM. As the network size becomes larger in these days, the conventional diagnosis methods based on tests and simulation become inefficient, or even more impractical. We propose a simple and easily implementable algorithm for detection and isolation of the multiple crosstalk-faults in OSM. Specifically. we develop an algorithm for isolation of the source fault in switching elements whenever the multiple crosstalk-faults arc detected in OSM. The proposed algorithm is illustrated by an example of 16$\times$16 OSM.

Alternate Time-Switched Space Frequency Block Coding Technique for Single-Carrier System (단일 반송파 시스템을 위한 교번 스위칭 공간 주파수 블록 코딩 기법)

  • Jung, Hyeok-Koo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.29-33
    • /
    • 2014
  • This paper proposes an alternate time-switched space-frequency block coding transmission technique for single-carrier modulation with frequency domain equalization. There are two antennas in the transmitter but it still has only a baseband and RF and a switch that alternates between the antennas at every symbol timing. Alternating transmit symbols result in zeros which make maximal ratio receive combining possible in the receiver. Simulation results show that it has better performance than the traditional algorithm at the expense of one additional antenna.

Alternate Time-Switched Multiplexed Space-Time Block Coding technique for OFDM systems (OFDM 시스템에 적용가능한 교번 스위칭하는 다중화 시공간 블록 코딩 기법)

  • Jung, Hyeok Koo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.2
    • /
    • pp.136-141
    • /
    • 2016
  • This paper proposes an alternate time-switched multiplexed space-time block coding technique for orthogonal frequency division modulation systems. The traditional multiplexed space-time block coding technique can provide more data rate owing to multiple transmit and receive technique, which causes a lot of hardware burden. Alternate time-switched scheme of transmitting time-domain zeros can reduce this hardware burden by half with time-domain switches only. Simulation results show that alternate time-switched scheme has almost same performance with half of baseband and RF modules in comparison with a multiplexed space-time block coding for orthogonal frequency division modulation systems with twice repetitive transmission.

Dynamic Characteristic of High Speed Permanent Magnet Synchronous Motor using the Space Vector PWM Switching Methods (공간 벡터 PWM 스위칭 기법을 이용한 고속 영구자석 동기전동기의 구동특성)

  • Jang, Seok-Myeong;Lee, Un-Ho;You, Dae-Joon;Park, Ji-Hoon;Kim, Il-Joong;Sung, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.713-714
    • /
    • 2008
  • This paper presents dynamic characteristic of permanent magnet synchronous motor using the space vector PWM(pulse-width modulated) which are drove by offset voltage modulation. It is shown by simulation which has the modeling about PWM inverter and PMSM. The validity of dynamic simulation has been confirmed by the phase back-EMF from FEM(Finite Element Methods) under the equal restrict.

  • PDF

A Soft-Switching Technique of Matrix Converters using Auxiliary Switch (보조스위치를 이용한 매트릭스 컨버터(Matrix Converter)의 소프트스위칭 기법)

  • Um, Tae-Wook;Kim, Yoon-Ho;Kim, Seung-Mo
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.519-524
    • /
    • 2002
  • This paper presents a soft-switching technique of single-stage power conversion Matrix Converter of AC-AC converters. Conventional hard-switching method is limited to operate at low switching frequency due to increased switching loss. In this paper, by additional auxiliary switch circuits, it is shown that the main switch of the matrix converter operate as a zero-voltage switches, and the auxiliary switch operate as a zero current switch. Finally, the soft-switching technique with auxiliary switches is compared with conventional hard-switching technique, and Is analyzed by simulation.

  • PDF

A Switching Technique for Common Mode Voltage Reduction of PWM-Inverter System using the DSP320F240 (DSP320F240을 이용한 PWM-Inverter구동 시스템에서의 전도노이즈 저감을 위한 스위칭 기법)

  • Park Hyun Seok;Park Kyu Hyun;Kim Lee Hun;Han Sung Yong;Won Chung Yuen;Kim Young Real
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.355-359
    • /
    • 2002
  • Much attention has been given to EMI effects created in variable speed ac drive system. Zero switching states of inverter control invoke large common mode voltage. This paper focuses on the switching techniques to mitigate common mode voltage. This paper proposes a common-mode voltage reduction method based on sinusoidal pulse width modulation in three phase PWM inverter system. By using three carriers wave displaced by 120 degrees, it is possible to eliminate a common mode voltage pulse In one control period. Simulation and experimental results show that common mode voltages In the proposed technique are reduced more than conventional technique.

  • PDF