• Title/Summary/Keyword: 순시

Search Result 514, Processing Time 0.042 seconds

A Single Phase Multi-level Active Power Filter System using Instantaneous Reactive Power Harmonic Detection Method (순시 무효 전력 고조파 검출방법을 이용한 단상 멀티레벨 능동전력 필터)

  • Kim Soo-Hong;Kim Sung-Min;Lee Kang-Hee;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.296-301
    • /
    • 2005
  • This paper proposing the use of the Instantaneous reactive power method as a harmonic detection method for a single phase active filter system. This method is to detect harmonic components through d-q frame approach. The conventional use of d-q frame approach for a 3-phase system Is extended to the single phase system. The proposed system uses a multi-level inverter for harmonic compensation and the inverter is connected to the input side without using transformers. The proposed algorithm is verified by simulation and experiment.

Design Method of Adaptive Ignitor for HID Lamps (HID 램프를 위한 상태 적응형 점화기 설계 방법)

  • Jo, Gye-Hyun;Song, Myoung-Suk;Park, Chong-Yeun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.7-14
    • /
    • 2004
  • The metal halide lamps are now widely used in the application and commercial lighting due to their attracting properties such as good color rendering and high efficiency. But, they have a serious problem of acoustic resonance using high frequency operation and they need a high voltage to ignite. So, they have not been applied to indoors. Over the past few years, a considerable number of studies have been conducted on the electronic ballast with hot restarting and resonance phenomenon. But, Very few attempts have been made at adaptive ignition method according to lamp state. In this paper is proposed electronicballast for metal halide lamps with an igniter for adaptive ignition. The proposed electronic bllast can generate a different ignition voltage according to the arc tube state.

The Space Vector Detection based Three-Phase Hybrid Series Active Power Filter for Compensating Dynamic Voltage Sag and Harmonic Current (순시전압 sag 및 고조파 전류 보상을 위한 공간벡터 검출법 기반의 3상 하이브리드 직렬형 능동전력필터)

  • 양승환;정영국;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.303-310
    • /
    • 2004
  • In this paper, for compensating dynamic voltage sag and harmonic current, 3-phase hybrid series active power filter based on the space vector detection is proposed. The Space vector algorithm for detecting the voltage sag and the harmonic current in compared with conventional theory is a simple method for calculating the compensating reference without any coordinated transformation. The effectiveness of the proposed system is verified by the PSIM simulation in the steady state and the transient state, which the proposed system is able to simultaneously compensate harmonics and source voltage unbalance / sag.

Variable Step Size Adaptive Algorithm using Instantaneous Absolute Value Based on System Generator (시스템 제너레이터 환경에서 순시 절대값을 이용한 가변스텝사이즈 적응알고리즘)

  • Lee, Chae-Wook;Ryu, Jeong-Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.3
    • /
    • pp.1-6
    • /
    • 2016
  • As the convergence speed of time domain adaptive algorithm on the LMS(Least Mean Square) becomes slow when eigen value distribution width is spread, So variable step size algorithm is used widely. But it needs a lot of calculation load. In this paper we consider new algorithm, which can reduce calculations and improve convergence speed, uses instantaneous absolute value of average noise signal adapting the exponential function. For the performance of proposed algorithm is tested and simulated to system generator. As the result we show the variable step size adaptive algorithm in proportion to instantaneous absolute value is more stable and efficient than others.

Ignition Characteristics of Metalhalide Lamp (메탈헬라이드 램프의 이그니션 특성 분석)

  • Bang, Sun-Bae;Kim, Chong-Min;Han, Woon-Ki;Lim, Byoung-Noh
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.117-120
    • /
    • 2007
  • 본 논문은 메탈헬라이드 램프들의 이그니션 특성 비교 분석을 위하여 이그니션 구간에서의 전압, 전류 및 순시임피던스(time varying resist ante), 순시전력(time varying power)을 측정하고 분석하였고, 측정 및 분석을 위하여 램프의 종류(B형, BT형)와 제조회사가 다른 램프 6종을 선택하여 사용하였다. 분석결과, 제조회사별, 램프 상태 둥에 따라 이그니션 특성이 매우 상이하게 나타났으며, 대부분의 램프 이그니션 전류가 40[A]를 상회하고 있고, 특히 몇몇 램프의 이그니션 전류는 50[A] 이상으로 나타났다 따라서 메탈헬라이드 램프들의 이그니션 전류는 정상상태보다 큰 이그니션 전류 및 순시전력이 발생되고 있음을 알 수 있었다. 따라서 본 연구 결과는 전자식 안정기 설계 시, 특정 램프 뿐만 아니라 여러 램프의 이그니션 전류를 만족하는 설계가 필요하며, 메탈헬라이드 램프 시공 시, 램프의 이그니션 구간에서 발생하는 1-2[kV] 고전압 및 50[A] 이상의 대전류에 따른 적절한 안전사고 대책 및 관등회로의 절연, 전선 굵기 선정이 필요한 것으로 나타났다.

  • PDF

A study on Instantaneous Speed Observer for Very Low Speed Drive of Induction Motors (유도전동기의 극저속도 운전을 위한 순시속도 관측기에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-Kwon;Jung, Nam-Gil
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.3
    • /
    • pp.117-126
    • /
    • 2012
  • This study configuration Vector Control System which is stable and has outstanding Dynamic Characteristics in Very Low Speed Region and Low Speed Region, and proposes Instantaneous Speed Observer and Very Low Speed Control method using Reduced-Dimensional State Observer. The Observer proposed in this system, by appling Reduced-Dimensional State Observer to Load-Torque estimation and using for speed estimation, implements system composition simply and is capable of accurate Instantaneous Speed estimation in Very Low Speed Region. Also, this study reduces influence by System Noise and suggests an induction motor speed control system which is effective in Load Disturbance, modeling error, estimation noise and so on without changing pole of an Observer.

A Test and Analysis of Instantaneous Trip Characteristics of Low Voltage 30AF Circuit Breakers (저압 30AF 차단기의 순시 Trip동작 특성시험 및 분석)

  • Kim, Ju-Chul;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.364-367
    • /
    • 2009
  • The role of the low voltage circuit breakers that are installed just before the load is very important for safety. This paper presents a test and analysis of the instantaneous trip characteristics of the Low Voltage 30AF(Ampere Frame) Circuit Breakers, which can be expected to be used for improving the safety of the Low Voltage Circuit Breaker.

  • PDF

뉴스페이지

  • KOREA ASSOCIATION OF HEALTH PROMOTION
    • 건강소식
    • /
    • v.7 no.3 s.52
    • /
    • pp.52-53
    • /
    • 1983
  • PDF