• Title/Summary/Keyword: 수평전단력

Search Result 114, Processing Time 0.031 seconds

Stability Analysis of Concrete Shear Wall System with Opening (개구부를 갖는 전단벽의 안정해석)

  • Lee, Soo-Gon;Kim, Soon-Chul;Song, Chang-Young;Song, Sang-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.109-118
    • /
    • 2005
  • A concrete shear wall system is commonly adopted in high-rise residential apartment buildings. In the construction stage, a rectangular opening is often made for the convenience of horizontal movement of workers, and construction materials and equipment. In the case of safety or stability assessment of a shear wall, the cutout part can be a critical factor. Finite element method is adopted to investigate the elastic stability behavior of the perforated unit shear wall. The key analysis parameters are the cutout location and its size. The effect of out-of-plane bending and horizontal shear are also examined in the stability analysis.

Development and Performance Evaluation of the Shear Connector of Composite Beam with Vertical Bars (직봉의 기능을 포함한 합성보의 전단연결재 개발과 성능평가)

  • Kim, Sang-Seup;Park, Dong-Soo;Boo, Yoon-Seob
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.725-736
    • /
    • 2011
  • In a composite beam, a shear connector is installed to resist the horizontal shear on an interface between steel beams and reinforced concrete slabs. The steel-wire-integrated deck plate slab is commonly used at the wide section beam. Then vertical bars are installed at the upper wire of the ends of the steel truss girder to ensure safety during the construction. The new type of shear connector is made of deformed bar and steel plates, and must function as vertical bars but must have higher shear capacity. This paper examines the ways to develop and utilize this new shear connector. From the push-out experiments, a shear connector made of a continuous deformed bar and steel plate showed a higher shear capacity and ductility than a ${\phi}16$ stud connector, and functioned as a vertical bar.

Analysis of Soil Nailed Wall Behaviour Based on Field Measurements (현장계측을 통한 소일네일링 벽체의 거동 분석)

  • 이철주;이도섭;김홍택;박재억;김충규
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.119-126
    • /
    • 2004
  • Behaviour of soil nailed walls in Korea has been analysed based on a number of field measurements. The investigation has included interface shear strength development at the nail-soil interface from pull-out tests, lateral ground displacements, tensile force distributions along soil nails and mobilised interface shear stress distributions. Insights into the soil nailed wall behaviour based on the shear transfer mechanism at the soil-nail interface and partial mobilisations of the interface shear strength, governed by relative shear displacement, are reported and discussed. It is expected that results from the current research can provide relevant parameters required for preliminary design of soil nailed walls in Korea.

Dissolution Monitoring of Geo-Soluble Mixtures (지반 소실 혼합재의 용해과정 모니터링)

  • Truong, Q. Hung;Byun, Yong-Hoon;Eom, Yong-Hun;Sim, Young-Jong;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.10
    • /
    • pp.111-122
    • /
    • 2009
  • Dissolution of some of geo-materials may yield the loss of the soil strength and the settlement of earth structures. The goal of this study is to monitor the several physical behaviors of soluble mixtures during dissolution. Sand-salt mixtures are used to monitor the meso to macro response including the settlements and shear waves. The mixtures of photoelastic and ice disks are used to monitor micro to meso behavior of soluble mixture including the void ratio, force chain, coordination number and horizontal force changes. In the sand-salt mixtures, shear waves are measured by using bender elements in conventional oedometer cells. In the photoelastic disk - ice disk mixtures, micro to meso response are measured by digital images and load cells. The shear wave velocity decreases at the initial stage of the dissolution, and then increases and approaches to asymptotic value. The larger dissoluble particle and the more random packing produces the severe horizontal fore change. After dissolution, the void increases and the coordination number decreases. This study demonstrates that the particle level behavior such as the changes of the force chain, void ratio, and coordination number affects the global behavior such as the change of the shear wave velocity and horizontal force of the system.

Horizontal Behavior Characteristics of Umbrella-Type Micropile Applied in Soft Clay Ground subjected to Seismic Motion (연약점토지반에 적용한 우산형 마이크로파일의 지진시 수평거동 특성)

  • Kim, Soo-Bong;Son, Su-Won;Kim, Jin-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.687-695
    • /
    • 2020
  • Micropile is used to improve the stability of existing structures as well as solve various geotechnical problems, such as suppressing slope activity and shearing keys of retaining walls. The existing micropile method has a significantly less capacity to resist a horizontal force than a vertical force0355 Therefore, it is necessary to develop and study an umbrella-type micropile method with excellent seismic performance that can secure seismic performance economically while minimizing structures and ground disturbance areas in the limited space of existing structures. In this study, numerical analysis was performed on the umbrella-type micropile, in which the sloped pile and vertical pile were combined, and the horizontal behavior in soft clay ground during earthquakes was analyzed. Numerical analysis showed that umbrella-type micropile suppresses horizontal displacement in soft ground, and the effect of reducing the horizontal displacement was more pronounced when the embedded depth of the slope pile was 15 m or more. The embedded depth of the micropile and horizontal displacement suppression effect was proportional. Therefore, the umbrella-type micropile has an excellent effect of suppressing horizontal displacement during earthquakes on soft clay ground.

Harmonic Excitation of Shear Building with Force-Controlled Shaking Table (힘-제어 진동대를 이용한 전단건물의 조화진동)

  • Lee, Sang Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.853-859
    • /
    • 2015
  • 1-DOF shear building was designed, built and tested to investigate the interactions between the shear building and the shaking table excited harmonically by the electro-magnetic forces. In the experiments horizontal accelerations of the shaking table and the shear building were measured. To understand the experimental results experimental setting was modeled as an unconstrained 2-DOF system under the hormonic forces. The responses of the shear building and the shaking table of the unconstrained 2-DOF system were found with the equations of motions. The magnification factors of the table and the shear building with respect to the amplitude of the harmonic forces and the transmission of the shear building with respect to the table excitations were found and compared with the experimental results.

Shear Strength of Prestressed PC-CIP Composite Beams with Vertical Shear Reinforcement (전단 철근 보강된 프리스트레스 PC와 CIP 합성보의 전단강도)

  • Suh, Jung-Il;Park, Hong-Gun;Hong, Geon-Ho;Kang, Su-Min;Kim, Chul-Goo
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.399-409
    • /
    • 2015
  • Recently, the use of composite construction method using precast (PC) and cast-in-place (CIP) concrete is increased in modular construction. For PC members, pre-tensioning is used to improve efficiency of the structural performance. However, current design codes do not clearly define shear strength of prestressed PC-CIP composite members. In this study, 22 specimens were tested to evaluate shear strength of prestressed composite members with vertical shear reinforcement. The test variables were the area ratio of high-strength (60 MPa) to low-strength concrete (24 MPa), prestressing force of strands, shear span-to-depth ratio(a/d), and vertical shear reinforcement ratio. The test results showed the prestressing force did not completely restrain diagonal cracking of non-prestressed concrete in the web. Thus, the effect of prestress force was not insignificant in the effect for monolithic beams. The vertical shear strength and horizontal shear strength of the composite beams were compared with the strength predictions of KCI design method.

Flexural Capacity of the Profiled Steel Composite Beams -Deep Deck Plate- (강판성형 합성보의 휨성능 평가 -춤이 깊은 합성데크-)

  • Heo, Byung Wook;Kwak, Myong Keun;Bae, Kyu Woong;Jeong, Sang Min
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.247-258
    • /
    • 2007
  • This paper describes the results of an experimental study on the new type of encased composite beams that use deep deck plates, which could reduce the story height of buildings by controlling the bottom flange of steel beams. The profiled steel beam was thus developed. It was advantageous to the long span of the buildings. Seven full-scale specimens were constructed, and simply supported bending tests were conducted on the encased composite beams with different steel plate thicknesses, with and without shear studs, reinforcing bars, and web openings. The test results showed that the encased composite beams that were developed in this study had sufficient composite action without additional shear connectors due to their inherent shear-bond effects between the steel beams and concrete.

Shear Strength and Failure Mode of Architectural Masonry Walls (내진보강된 치장조적벽의 파괴특성과 전단강도)

  • Jin, Hee-Yong;Han, Sang-Whan;Park, Young-Mi
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.89-92
    • /
    • 2008
  • This study investigates the shear behavior of architectural masonry veneer wall reinforced with specific reinforcement details proposed by this study. For this purpose, experimental tests were conducted using one un-reinforced masonry(URM) wall specimen and three reinforced masonry(RM) wall specimens under quasi static cyclic loads. Un-reinforced(plain) masonry wall is expressed that behavior and failure mode are different for aspect ratio(L/H) and axial compressive force. The test variables are wall aspect ratio and presence of reinforcement. These specimens are masonry structure for architectural clading that is not to exist the axial compressive force. thus the axial compressive force is excepted from test variable. Test result, Behavior of specimens are dominated over rocking mode, but final failure modes are combined with different behaviors. And FEMA273 has proposed the equation of shear strength of masonry pier subjected to in-plane loading. Shear strength equations are classified four types of failure mode that is Rocking, and Toe-Crushing, Bed-Joint-Sliding and Diagonal-Tension. FEMA273 equations predict the behavior modes well, but shear strength is shown in different result.

  • PDF

On The Development of Design Wave Loads in Classification Rules(I) (선급 강선규칙의 설계 파랑하중 산식 개발(I))

  • J.Y. Song;Y.K. Chon;T.B. Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.4
    • /
    • pp.112-126
    • /
    • 1993
  • In this paper, unified requirements of IACS on longitudinal strength of ships are investigated using nonlinear wave loads analyses under short term irregular waves. Also, analyses on IACS wave data were carried out for the purpose of presenting the guideline for future use. While keeping theoretical consistensy, the rule requirements for horizontal shear force, bending moment and torsional moment are newly proposed for the ships of large deck openings bases on the calculation results for 17 sample ships. The requirements for side shell hydrodynamic pressure are also presented. All the calculated results are compared with other Societies and present KR rules. These formula will be checked when corresponding requirements of structural scantling are determined.

  • PDF